首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Matrix-assisted laser desorption/ionization (tandem) mass spectrometry (MALDI MS) is widely used in protein chemistry and proteomics research for the identification and characterization of proteins isolated by polyacrylamide gel electrophoresis. In an effort to minimize sample handling and increase sample throughput, we have developed a novel in-gel digestion protocol where sample preparation is performed directly on a MALDI probe with prestructured sample support. The protocol consists of few sample-handling steps and has minimal consumption of reagents, making the protocol sensitive, timesaving, and cost-efficient. Performance of the on-probe sample preparation protocol was demonstrated by analysis of a set of rat liver proteins obtained from a fluorescently stained (Cy3 and SyproRuby) two-dimensional polyacrylamide gel. The success rate of protein identification by on-probe tryptic digestion and MALDI peptide mass mapping was 89%. The on-probe in-gel digestion procedure provided superior sensitivity and peptide mass mapping performance as compared to our standard in-gel digestion protocol. The on-probe digestion technique resulted in significantly improved amino acid sequence coverage of proteins, mainly due to efficient recovery and detection of large (>1.5 kDa) hydrophobic peptides. These observations indicate that numerous tryptic peptides are lost when using the standard in-gel digestion methods and sample preparation techniques for MALDI MS. This study also demonstrates that the on-probe digestion protocol combined with MALDI tandem mass spectrometry provides a robust platform for proteomics research, including protein identification and determination of posttranslational modifications.  相似文献   

2.
Garza S  Moini M 《Analytical chemistry》2006,78(20):7309-7316
Identification of proteins, in a complex protein mixture, using one-dimensional high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) analysis of its digest, usually suffers from low sequence coverage. There are several reasons for the low coverage including undersampling, wide concentration dynamic range of the proteins in a complex protein mixture, and wide range of electrospray ionization efficiency of peptides under each mobile-phase composition. To address this low sequence coverage, we introduce a novel technique, (CE-MS/MS)n, which utilizes the most significant advantages of CE-MS/MS, including economy of sample size, fast analysis time, and high separation efficiency, to increase the sequence coverage of a complex protein mixture. Based on these characteristics, (CE-MS/MS)n can be performed in which multiple CE-MS/MS subanalyses (injections followed by analyses) are analyzed and experimental variables are manipulated during each CE-MS/MS subanalysis in order to maximize sequence coverage. (CE-MS/MS)n is a practical technique since each CE-MS/MS subanalysis consumes <10 nL, and each CE-MS/MS subanalysis takes approximately 10 min; therefore, several subanalyses can be performed in approximately 1 h consuming only nanoliters of the sample. Two techniques have been introduced to address the undersampling: (1) (CE-MS/MS)n using dynamic exclusion. In this technique, several CE-MS/MS analyses (injection followed by separation) were performed in one run using the dynamic exclusion capability of the mass spectrometer until all peptide peaks were analyzed by MS/MS. (2) Gas-phase fractionation. In this technique, (CE-MS/MS)n is performed by scanning a narrow mass range (every approximately 100 m/z) during each CE-MS/MS subanalysis without using dynamic exclusion. Under this condition, in each subanalysis, the number of peptides available for MS/MS analysis is significantly reduced, and peptides with the same nominal masses are analyzed, thereby increasing sequence coverage. Additionally, to address the lack of detection of low-level peptides in a mixture containing a wide concentration dynamic range, the concentration of the sample was systematically increased in each subanalysis (while utilizing dynamic exclusion) so that low-intensity peptides would rise above the mass spectrometer threshold and, consequently, undergo MS/MS analysis. Moreover, to alter the ionization efficiency of peptides with low electrospray ionization efficiency, and to change the migration behavior of comigrating peptides under a specific liquid composition, the CE background electrolyte was modified in several subanalyses to further improve sequence coverage. The combination of the above-mentioned techniques was applied to the analysis of the tryptic digests of three well-characterized protein mixtures: a six-protein mixture with average MW of approximately 26,000 (standard I), a six-protein mixture with an average MW approximately 49,000 (standard II), and a more complex protein mixture containing 55 proteins (E. coli ribosomal proteins). In approximately 1 h, when the MS/MS of the peptides were manually checked, all peptides that produced peaks under electrospray ionization in the scanned range of the analysis (500-2000 m/z) and within the practical fragmentation capability of the MS (peptides with MW <3500) were identified for standard I by consuming only 200 fmol of each protein. When searched against a Swissprot database, the average sequence coverage for the standard I, II, and E. coli's ribosomal proteins were 57, 34, and 15%, respectively.  相似文献   

3.
Pan S  Gu S  Bradbury EM  Chen X 《Analytical chemistry》2003,75(6):1316-1324
Identification of proteins with low sequence coverage using mass spectrometry (MS) requires tandem MS/MS peptide sequencing. It is very challenging to obtain a complete or to interpret an incomplete tandem MS/MS spectrum from fragmentation of a weak peptide ion signal for sequence assignment. Here, we have developed an effective and high-throughput MALDI-TOF-based method for the identification of membrane and other low-abundance proteins with a simple, one-dimensional separation step. In this approach, several stable isotope-labeled amino acid precursors were selected to mass-tag, in parallel, the human proteome of human skin fibroblast cells in a residue-specific manner during in vivo cell culturing. These labeled residues can be recognized by their characteristic isotope patterns in MALDI-TOF MS spectra. The isotope pattern of particular peptides induced by the different labeled precursors provides information about their amino acid compositions. The specificity of peptide signals in a peptide mass mapping is thus greatly enhanced, resolving a high degree of mass degeneracy of proteolytic peptides derived from the complex human proteome. Further, false positive matches in database searching can be eliminated. More importantly, proteins can be accurately identified through a single peptide with its m/z value and partial amino acid composition. With the increased solubility of hydrophobic proteins in SDS, we have demonstrated that our approach is effective for the identification of membrane and low-abundant proteins with low sequence coverage and weak signal intensity, which are often difficult for obtaining informative fragment patterns in tandem MS/MS peptide sequencing analysis.  相似文献   

4.
Ultrasensitive nanoscale proteomics approaches for characterizing proteins from complex proteomic samples of <50 ng of total mass are described. Protein identifications from 0.5 pg of whole proteome extracts were enabled by ultrahigh sensitivity (<75 zmol for individual proteins) achieved using high-efficiency (peak capacities of approximately 10(3)) 15-microm-i.d. capillary liquid chromatography separations (i.e., using nanoLC, approximately 20 nL/min mobile-phase flow rate at the optimal linear velocity of approximately 0.2 cm/s) coupled on-line with a micro-solid-phase sample extraction and a nanoscale electrospray ionization interface to a 11.4-T Fourier transform ion cyclotron resonance (FTICR) mass spectrometer (MS). Proteome measurement coverage improved as sample size was increased from as little as 0.5 pg of sample. It was found that a 2.5-ng sample provided 14% coverage of all annotated open reading frames for the microorganism Deinococcus radiodurans, consistent with previous results for a specific culture condition. The estimated detection dynamic range for detected proteins was 10(5)-10(6). An improved accurate mass and LC elution time two-dimensional data analysis methodology, used to both speed and increase the confidence of peptide/protein identifications, enabled identification of 872 proteins/run from a single 3-h nanoLC/FTICR MS analysis. The low-zeptomole-level sensitivity provides a basis for extending proteomics studies to smaller cell populations and potentially to a single mammalian cell. Application with ion trap MS/MS instrumentation allowed protein identification from 50 pg (total mass) of proteomic samples (i.e., approximately 100 times larger than FTICR MS), corresponding to a sensitivity of approximately 7 amol for individual proteins. Compared with single-stage FTICR measurements, ion trap MS/MS provided a much lower proteome measurement coverage and dynamic range for a given analysis time and sample quantity.  相似文献   

5.
We describe the impact of advances in mass measurement accuracy, +/- 10 ppm (internally calibrated), on protein identification experiments. This capability was brought about by delayed extraction techniques used in conjunction with matrix-assisted laser desorption ionization (MALDI) on a reflectron time-of-flight (TOF) mass spectrometer. This work explores the advantage of using accurate mass measurement (and thus constraint on the possible elemental composition of components in a protein digest) in strategies for searching protein, gene, and EST databases that employ (a) mass values alone, (b) fragment-ion tagging derived from MS/MS spectra, and (c) de novo interpretation of MS/MS spectra. Significant improvement in the discriminating power of database searches has been found using only molecular weight values (i.e., measured mass) of > 10 peptide masses. When MALDI-TOF instruments are able to achieve the +/- 0.5-5 ppm mass accuracy necessary to distinguish peptide elemental compositions, it is possible to match homologous proteins having > 70% sequence identity to the protein being analyzed. The combination of a +/- 10 ppm measured parent mass of a single tryptic peptide and the near-complete amino acid (AA) composition information from immonium ions generated by MS/MS is capable of tagging a peptide in a database because only a few sequence permutations > 11 AA's in length for an AA composition can ever be found in a proteome. De novo interpretation of peptide MS/MS spectra may be accomplished by altering our MS-Tag program to replace an entire database with calculation of only the sequence permutations possible from the accurate parent mass and immonium ion limited AA compositions. A hybrid strategy is employed using de novo MS/MS interpretation followed by text-based sequence similarity searching of a database.  相似文献   

6.
Transthyretin (TTR) is a 127-amino acid residue transport protein. In plasma, TTR exists as a tetramer and binds the hormone thyroxine and the retinol-binding protein-vitamin A complex. Amino acid substitutions in TTR are hypothesized to destabilize the tetramer and cause the protein to form intermediates that self-associate into amyloid fibrils. Familial transthyretin amyloidosis (ATTR) is associated with extracellular deposition of wild-type TTR, its variants or fragments as amyloid fibrils in various tissues and organs. A definitive diagnosis of ATTR depends on the detection and identification of TTR variants. Electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometry (MS), in combination with trypsin digestion, have been shown to be powerful tools in characterizing TTR variants. Typically, TTR or its tryptic digest is analyzed by MALDI-TOF MS, liquid chromatography ESI MS, or both. Analysis of tryptic digests by MALDI-TOF MS does not provide enough sequence coverage in TTR to identify all possible modifications. To improve sequence coverage, aliquots of immunoprecipitated TTR samples were digested with trypsin, lysyl endopeptidase Lys-C, or endoproteinase Asp-N. Identification of the peptides from each digest by MALDI-TOF MS provided preliminary information about the sites and mass shifts due to amino acid substitutions from genetic mutations and to posttranslational modifications. The location and identity of the modifications in the variant proteins were then confirmed by tandem mass spectrometry, accurate mass measurements, and direct DNA sequence analysis. Using these methodologies, we achieved 100% sequence coverage. The detection of two nonpathologic variants (Thr119Met and Gly6Ser) and four pathologic variants (Phe64Leu, Asp38Ala, Phe44Ser, and previously unreported Trp41Leu) are described as illustrations of this approach.  相似文献   

7.
A method is developed to integrate a protein separation by monolithic capillary reversed-phase high-performance liquid chromatography to on-probe tryptic digestion for subsequent analyses by MALDI-TOF MS and MALDI-TOF/TOF MS. The method provides a means of directly interfacing separations to MALDI-MS, reducing the amount of time required for traditional procedures involving in-solution enzymatic digestion and sample cleanup prior to MALDI-MS analysis. When used with pI-based fractionation as a first dimension, it provides a means of analyzing complex mixtures of proteins with minimal sample handling and cleanup. The use of monolithic capillary columns sufficiently resolved intact proteins so that peptide mass fingerprinting analysis by MALDI-TOF MS resulted in the identification of close to 40 unique proteins from 120 ng of sample obtained from a prefractionated MCF10 cell line at pH 6.34, where the identifications of several of these proteins were also confirmed by intact MW and tandem mass spectrometric analysis. The reproducibility of this method has been demonstrated to be sufficient for the purpose of protein identifications. Experimental values of protein intact MW are obtained and compared to that expected for each protein identified.  相似文献   

8.
A two-dimensional liquid phase separation of proteins from whole cell lysates coupled on-line to an electrospray-ionization time-of-flight (ESI-TOF) mass spectrometer (MS) is used to map the protein content of ovarian surface epithelial cells (OSE) and an ovarian carcinoma-derived cell line (ES2). The two dimensions involve the use of liquid isoelectric focusing as the first phase and nonporous silica reversed-phase HPLC as the second phase of separation. Accurate molecular weight (MW) values are then obtained upon the basis of ESI-TOFMS so that an image of isolectric point (pI) versus MW analogous to 2-D gel electrophoresis is produced. The accurate MW together with the pI fraction and corresponding hydrophobicity (%B) are used to tag each protein so that protein expression can be compared in interlysate studies. Each protein is also identified on the basis of matrix-assisted laser desorption-ionization (MALDI) TOFMS peptide mapping and intact MW so that a standard map is produced against which other cell lines can be compared. Quantitative changes in protein expression are measured in these interlysate comparisons using internal standards in the on-line ESI-TOFMS process. In the ovarian epithelial cell lines under study, it is shown that in the three pI fractions chosen for detailed analysis, over 50 unique proteins can be detected per fraction, of which 40% can be identified from web-based databases. It is also shown that when using an accurate MW to compare proteins in the OSE versus ovarian cancer sample, there are proteins highly expressed in cancer cells but not in normal cells. In addition, many of the proteins in the cancer sample appear to be down-regulated, as compared to the normal cells. This two-dimensional (2-D) liquid/mass mapping method may provide a means of studying proteins in interlysate comparisons not readily available by other methods.  相似文献   

9.
The present study reports a procedure developed for the identification of SDS-polyacrylamide gel electrophoretically separated proteins using an electrospray ionization quadrupole time-of-flight mass spectrometer (Q-TOF MS) equipped with pressurized sample introduction. It is based on in-gel digestion of the proteins without previous reduction/alkylation and on the capability of the Q-TOF MS to provide data suitable for peptide mass fingerprinting database searches and for tandem mass spectrometry (MS/MS) database searches (sequence tags). Omitting the reduction/alkylation step reduces sample contamination and sample loss, resulting in increased sensitivity. Omitting this step can leave disulfide-connected peptides in the analyte that can lead to misleading or ambiguous results from the peptide mass fingerprinting database search. This uncertainty, however, is overcome by MS/MS analysis of the peptides. Furthermore, the two complementary MS approaches increase the accuracy of the assignment of the unknown protein. This procedure is thus, highly sensitive, accurate, and rapid. In combination with pressurized nanospray sample introduction, it is suitable for automated sample handling. Here, we apply this approach to identify protein contaminants observed during the purification of the yeast DNA mismatch repair protein Mlh 1.  相似文献   

10.
A major limitation of mass spectrometry-based proteomics is inefficient and differential ionization during electrospray ionization (ESI). This leads to problems such as increased limits of detection and incomplete sequence coverage of proteins. Incomplete sequence coverage is especially problematic for analyses that require the detection and identification of specific peptides from a protein, such as the analysis of post-translational modifications. We describe here the development and use of aldehyde-based chemistry for the alkylation of peptide primary amines to increase peptide hydrophobicity, providing increased ionization efficiency and concomitant signal enhancement. When employed to modify the peptide products of protein tryptic digests, increased sequence coverage is obtained from combined modified and unmodified digests. To evaluate the utility of alkylation of peptides for selected reaction monitoring (SRM) assays, we alkylated a peptide from the protein Oct4, known to play a role in regulating stem cell differentiation. Increased chromatographic retention and ionization efficiency is observed for the alkylated Oct4 peptide compared to its unmodified form.  相似文献   

11.
We investigated and compared three approaches for shotgun protein identification by combining MS and MS/MS information using LTQ-Orbitrap high mass accuracy data. In the first approach, we employed a unique mass identifier method where MS peaks matched to peptides predicted from proteins identified from an MS/MS database search are first subtracted before using the MS peaks as unique mass identifiers for protein identification. In the second method, we used an accurate mass and time tag method by building a potential mass and retention time database from previous MudPIT analyses. For the third method, we used a peptide mass fingerprinting-like approach in combination with a randomized database for protein identification. We show that we can improve protein identification sensitivity for low-abundance proteins by combining MS and MS/MS information. Furthermore, "one-hit wonders" from MS/MS database searching can be further substantiated by MS information and the approach improves the identification of low-abundance proteins. The advantages and disadvantages for the three approaches are then discussed.  相似文献   

12.
A combinatory approach for the characterization of post-translational and chemical modifications in high molecular weight therapeutic proteins like antibodies and peptide-Fc fusion proteins (MW > or = 50 000 Da) is presented. In this approach, well-established techniques such as limited proteolysis, reversed-phase (RP) high-performance liquid chromatography (HPLC), and in-line mass spectrometry (MS) were combined for the characterization of a monoclonal IgG1 antibody and three different peptide-Fc fusion proteins. The one commonality of these molecules is the presence of a similarly accessible lysine residue either located in the flexible hinge region of the antibody or in the flexible linker of the peptide-Fc fusion proteins. Applying limited proteolysis using endoproteinase Lys-C resulted in the predominant cleavage C-terminal of this lysine residue. The created fragments, two identical Fab domain fragments and one Fc domain fragment derived from the IgG1 antibody and one Fc domain fragment and each of the three individual peptide moieties generated from the peptide-Fc fusion proteins, were readily accessible for complete separation by RP-HPLC and detailed characterization by in-line MS analysis. This approach facilitated rapid detection of a variety of chemical modifications such as methionine oxidation, disulfide bond scrambling, and reduction as well as the characterization of various carbohydrate chains. We found limited proteolysis followed by RP-HPLC-MS to be less time-consuming for sample preparation, analysis, and data interpretation than traditional peptide mapping procedures. At the same time, the reduced sample complexity provided superior chromatographic and mass spectral resolution than the analysis of the corresponding intact molecules or a large number of enzymatically generated fragments.  相似文献   

13.
Proteins from breast cancer cell lines are characterized using a 2-D liquid separation technique in which protein pI is used as the first-dimension separation parameter. To effect this protein pI separation, chromatofocusing(CF) is employed whereby a pH gradient is generated on-column using a weak anion exchange medium with the intact proteins fractionated and collected every 0.2 pH unit. It is demonstrated that the pI for expressed intact proteins as generated by CF is an important parameter for identification and characterization of the actual protein modifications occurring in the cancer cell. For most proteins, the experimentally determined pI is very close to that predicted by the databases. In other cases, however, where the pI is observed to be shifted from the expected value, it is shown that this shift is often correlated to protein modifications. The modifications that cause such shifts include truncations and deletions often observed in cancer cells or phosphorylations that can shift the pI by several pH units. It is also shown that the effects of phosphorylation on the observed shift can vary depending upon the protein and the amount of phosphorylation. Moreover, large changes in the pI are often observed for proteins with a pI above 7.0 upon phosphorylation, whereas little change is observed for proteins with a pI of approximately 5.0. The expressed protein's pI value thus becomes an important parameter together with the intact MW value, peptide map, and MS/MS results for identification of the presence and type of posttranslational modifications occurring in the cancer cell.  相似文献   

14.
Divinyl sulfone reacts at pH 8-9 with the alpha-amino groups of N-terminal residues, proline, the epsilon-amino groups of lysine, and the histidine side chains of peptides. This reaction leads to great enhancement of the abundance of the normally weak or missing "a(1)" fragment ion in MS/MS analysis defining the N-terminal residue of a peptide in a digest. This provides "one-step Edman-like" information that, together with a fairly accurately determined mass, often enables one to correctly identify a protein or family of proteins. The applicability of this procedure in proteomics was demonstrated with several peptides and tryptic digests of protein mixtures by LC-MS/MS experiments using a QTOF and MALDI-PSD analyses. Advantages of this approach are its simple chemistry, retention of charge multiplicity, and possibly, shortening of database search time. Used with other MS/MS data, it provides higher confidence in the scores and identification of a protein found in peptide mass fingerprinting. Moreover, this approach has an advantage in "de novo" sequencing due to its ability to decipher the first amino acid of a peptide whose information is normally unavailable in MS/MS spectra.  相似文献   

15.
A novel extension of the "top-down" approach is introduced for the selective characterization of protein termini that does not involve proteolytic digestion steps. N- and C-terminal peptides were generated from intact proteins in the mass spectrometer and further analyzed by MS/MS-an approach referred to as T(3)-sequencing. N-terminal and C-terminal fragment ion series were obtained by the pseudo-MS/MS technique in-source decay (ISD) on a matrix-assisted laser desorption/ionization time-of-flight mass spectrometer (MALDI-TOF MS). These ions provided near-terminal sequence tags from the undigested protein in the ISD spectrum acquired in reflector mode and allowed to screen for the proper processing state of the terminus with respect to a reference sequence. In the second step of T(3)-sequencing, the precursor ions, which have been generated by ISD and which included the N- or C-terminal sequence, were selected in the timed ion gate of a MALDI-TOF/TOF mass spectrometer for MS/MS analysis. These spectra allowed identification of the protein, the proper definition of both termini, and allowed confirmation of suspected terminal modifications. T(3)-Sequencing appears to be an alternative to classical Edman sequencing, which is fast and even permits the analysis of N-terminally blocked proteins and their C-terminus.  相似文献   

16.
Young JB  Li L 《Analytical chemistry》2007,79(15):5927-5934
An automated off-line liquid chromatography-matrix-assisted laser desorption ionization (LC-MALDI) interface capable of coupling both capillary and microbore LC separations with MALDI mass spectrometry (MS) and tandem mass spectrometry (MS/MS) has been developed. The interface is a combination of two concepts: analyte concentration from heated hanging droplets and impulse-driven droplet deposition of LC fractions onto a MALDI sample plate. At room temperature the interface allows the coupling of capillary LC separations (i.e., flow rate of <5 microL/min) with MALDI MS. With heating, it can be used to combine microbore LC operated at a relatively high flow rate of up to 50 microL/min with MALDI MS. The collected fractions can be analyzed by MALDI MS and MS/MS instruments, such as time-of-flight (TOF) and quadrupole-TOF MS. Performance of the interface was examined using several peptide and protein standards. It was shown that, using MALDI-TOF MS, [GLU1]-fibrinopeptide B could be detected with a total injection amount of 5 fmol to microbore LC. Chromatographic performance was also monitored. A peak width of 12 s at half-height for [GLU1]-fibrinopeptide B showed no evidence of band broadening due to the interface. The ability of the interface to mitigate ion suppression was studied using a mixture of 100 fmol of [GLU1]-fibrinopeptide B and 10 pmol of cytochrome c tryptic digest. Although fully suppressed under direct MALDI conditions, LC-MALDI analysis was able to detect the 100 fmol peptide with 10 s fraction collection. Finally, the ability to inject relatively large sample amounts to improve detectability of low-abundance peptides was illustrated in the analysis of phosphopeptides from alpha-casein tryptic digests. A digest loaded on column to 2.4 microg and analyzed by LC-MALDI MS/MS resulted in 82% sequence coverage and detection of all nine phosphoserine residues. It is concluded that, being able to handle both high- and low-flow LC separations, the impulse-driven heated-droplet interface provides the flexibility to carry out MALDI analysis of peptides and proteins depending on the information sought after, analysis speed, and sample size.  相似文献   

17.
Tandem mass spectrometry is the prevailing approach for large-scale peptide sequencing in high-throughput proteomic profiling studies. Effective database search engines have been developed to identify peptide sequences from MS/MS fragmentation spectra. Since proteins are polymorphic and subject to post-translational modifications (PTM), however, computational methods for detecting unanticipated variants are also needed to achieve true proteome-wide coverage. Different from existing "unrestrictive" search tools, we present a novel algorithm, termed SIMS (for Sequential Motif Interval Search), that interprets pairs of product ion peaks, representing potential amino acid residues or "intervals", as a means of mapping PTMs or substitutions in a blind database search mode. An effective heuristic software program was likewise developed to evaluate, rank, and filter optimal combinations of relevant intervals to identify candidate sequences, and any associated PTM or polymorphism, from large collections of MS/MS spectra. The prediction performance of SIMS was benchmarked extensively against annotated reference spectral data sets and compared favorably with, and was complementary to, current state-of-the-art methods. An exhaustive discovery screen using SIMS also revealed thousands of previously overlooked putative PTMs in a compendium of yeast protein complexes and in a proteome-wide map of adult mouse cardiomyocytes. We demonstrate that SIMS, freely accessible for academic research use, addresses gaps in current proteomic data interpretation pipelines, improving overall detection coverage, and facilitating comprehensive investigations of the fundamental multiplicity of the expressed proteome.  相似文献   

18.
Subfemtomole peptide sequence analysis has been achieved using microcapillary HPLC columns, with integrated nanoelectrospray emitters, coupled directly to a Fourier transform ion cyclotron resonance mass spectrometer. Accurate mass (+/-0.010 Da) peptide maps are generated from a standard six-protein digest mixture, whose principle components span a concentration dynamic range of 1000:1. Iterative searches against approximately 189000 entries in the OWL database readily identify each protein, with high sequence coverage (20-60%), from as little as 10 amol loaded on-column. In addition, a simple variable-flow HPLC apparatus provides for on-line tandem mass spectrometric analysis of tryptic peptides at the 400-amol level. MS/MS data are searched against approximately 280000 entries in a nonredundant protein database using SEQUEST. Accurate precursor and product ion mass information readily identifies primary amino acid sequences differing by asparagine vs aspartic acid (deltam = 0.98 Da) and glutamine vs lysine (deltam = 0.036 Da).  相似文献   

19.
A MALDI QqTOF mass spectrometer has been used to identify proteins separated by one-dimensional or two-dimensional gel electrophoresis at the femtomole level. The high mass resolution and the high mass accuracy of this instrument in both MS and MS/MS modes allow identification of a protein either by peptide mass fingerprinting of the protein digest or from tandem mass spectra acquired by collision-induced dissociation of individual peptide precursors. A peptide mass map of the digest and tandem mass spectra of multiple peptide precursor ions can be acquired from the same sample in the course of a single experiment. Database searching and acquisition of MS and MS/MS spectra can be combined in an interactive fashion, increasing the information value of the analytical data. The approach has demonstrated its usefulness in the comprehensive characterization of protein in-gel digests, in the dissection of complex protein mixtures, and in sequencing of a low molecular weight integral membrane protein. Proteins can be identified in all types of sequence databases, including an EST database. Thus, MALDI QqTOF mass spectrometry promises to have remarkable potential for advancing proteomic research.  相似文献   

20.
Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) is a central tool for proteomic analysis, yet the singly protonated tryptic peptide ions produced by MALDI are significantly more difficult to dissociate for tandem mass spectrometry (MS/MS) than the corresponding multiply protonated ions. In order to overcome this limitation, current proteomic approaches using MALDI-MS/MS involve high-energy collision-induced dissociation (CID). Unfortunately, the use of high-energy CID complicates product ion spectra with a significant proportion of irrelevant fragments while also reducing mass accuracy and mass resolution. In order to address the lack of a high-resolution, high mass accuracy MALDI-MS/MS platform for proteomics, Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) and a recently developed MS/MS technique termed CIRCA (for combination of infrared and collisional activation) have been applied to proteomic analysis. Here, CIRCA is shown to be suitable for dissociating singly protonated tryptic peptides, providing greater sequence coverage than either CID or infrared multiphoton dissociation (IRMPD) alone. Furthermore, the CIRCA fragmentation spectra are of sufficient quality to allow protein identification based on the MS/MS spectra alone or in concert with the peptide mass fingerprint (PMF). This is accomplished without compromising mass accuracy or mass resolution. As a result, CIRCA serves to enable MALDI-FTICR-MS/MS for high-performance proteomics experiments.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号