首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Jiang X  Zhong J  Liu Y  Yu H  Zhuo S  Chen J 《Scanning》2011,33(1):53-56
Multiphoton microscopic imaging of collagen plays an important role in noninvasive diagnoses of human tissue. In this study, two-photon fluorescence and second-harmonic generation (SHG) imaging of collagen in human skin dermis and submucosa of colon and stomach tissues were investigated based on multiphoton microscopy (MPM). Our results show that multiphoton microscopic image of collagen bundles exhibits apparently different pattern in human tissues. The collagen bundles can simultaneously reveal its SHG and two-photon excited fluorescence images in the submucosa of colon and stomach, whereas it solely emit SHG signal in skin dermis. The intensity spectral information from tissues further demonstrated the above results. This indicates that collagen bundles have completely different space arrangement in these tissues. Our experimental results bring more detailed information of collagen for the application of MPM in human noninvasive imaging.  相似文献   

2.
3.
4.
Glioblastoma multiforme (GBM‐WHO grade IV) is the most common and the most aggressive form of brain tumors in adults with the median survival of 10–12 months. The diagnostic detection of extracellular matrix (ECM) component in the tumour microenvironment is of prognostic value. In this paper, the fibrillar collagen deposition associated with vascular elements in GBM were investigated in the fresh specimens and unstained histological slices by using multiphoton microscopy (MPM) based on two‐photon excited fluorescence (TPEF) and second harmonic generation (SHG). Our study revealed the existence of fibrillar collagen deposition in the adventitia of remodelled large blood vessels and in glomeruloid vascular structures in GBM. The degree of fibrillar collagen deposition can be quantitatively evaluated by measuring the adventitial thickness of blood vessels or calculating the ratio of SHG pixel to the whole pixel of glomeruloid vascular structure in MPM images. These results indicated that MPM can not only be employed to perform a retrospective study in unstained histological slices but also has the potential to apply for in vivo brain imaging to understand correlations between malignancy of gliomas and fibrillar collagen deposition.  相似文献   

5.
In this work, we proposed and built a multimodal optical setup that extends a commercially available confocal microscope (Olympus VF300) to include nonlinear second harmonic generation (SHG) and third harmonic generation (THG) optical (NLO) microscopy and fluorescence lifetime imaging microscopy (FLIM). We explored all the flexibility offered by this commercial confocal microscope to include the nonlinear microscopy capabilities. The setup allows image acquisition with confocal, brightfield, NLO/multiphoton and FLIM imaging. Simultaneously, two‐photon excited fluorescence (TPEF) and SHG are well established in the biomedical imaging area, because one can use the same ultrafast laser and detectors set to acquire both signals simultaneously. Because the integration with FLIM requires a separated modulus, there are fewer reports of TPEF+SHG+FLIM in the literature. The lack of reports of a TPEF+SHG+THG+FLIM system is mainly due to difficulties with THG because the present NLO laser sources generate THG in an UV wavelength range incompatible with microscope optics. In this article, we report the development of an easy‐to‐operate platform capable to perform two‐photon fluorescence (TPFE), SHG, THG, and FLIM using a single 80 MHz femtosecond Ti:sapphire laser source. We described the modifications over the confocal system necessary to implement this integration and verified the presence of SHG and THG signals by several physical evidences. Finally, we demonstrated the use of this integrated system by acquiring images of vegetables and epithelial cancer biological samples. Microsc. Res. Tech. 2012. © 2012 Wiley Periodicals, Inc.  相似文献   

6.
7.
We describe a compact, non‐contact design for a total emission detection (c‐TED) system for intra‐vital multiphoton imaging. To conform to a standard upright two‐photon microscope design, this system uses a parabolic mirror surrounding a standard microscope objective in concert with an optical path that does not interfere with normal microscope operation. The non‐contact design of this device allows for maximal light collection without disrupting the physiology of the specimen being examined. Tests were conducted on exposed tissues in live animals to examine the emission collection enhancement of the c‐TED device compared to heavily optimized objective‐based emission collection. The best light collection enhancement was seen from murine fat (5×–2× gains as a function of depth), whereas murine skeletal muscle and rat kidney showed gains of over two and just under twofold near the surface, respectively. Gains decreased with imaging depth (particularly in the kidney). Zebrafish imaging on a reflective substrate showed close to a twofold gain throughout the entire volume of an intact embryo (approximately 150 μm deep). Direct measurement of bleaching rates confirmed that the lower laser powers, enabled by greater light collection efficiency, yielded reduced photobleaching in vivo. The potential benefits of increased light collection in terms of speed of imaging and reduced photo‐damage, as well as the applicability of this device to other multiphoton imaging methods is discussed.  相似文献   

8.
We describe a novel two‐photon fluorescence microscopy system capable of producing high‐quality second harmonic generation (SHG) images in thick turbid media by using an innovative detection system. This novel detection system is capable of detecting photons from a very large surface area. This system has proven effective in providing images of thick turbid samples, both biological and artificial. Due to its transmission detection geometry, the system is particularly suitable for detecting SHG signals, which are generally forward directed. In this article, we present comparative data acquired simultaneously on the same sample with the forward and epidetection schemes. Microsc. Res. Tech. 77:368–373, 2014. © 2014 Wiley Periodicals, Inc.  相似文献   

9.
The spinal cord is a vital link between the brain and the body and mainly comprises neurons, glial cells and nerve fibres. In this work, nonlinear optical (NLO) microscopy based on intrinsic tissue properties was employed to label‐freely analyze the cells and matrix in spinal cords at a molecular level. The high‐resolution and high‐contrast NLO images of unstained spinal cords demonstrate that NLO microscopy has the ability to show the microstructure of white and grey matter including ventral horn, intermediate area, dorsal horns, ventral column, lateral column and dorsal column. Neurons with various sizes were identified in grey matter by dark spots of nonfluorescent nuclei encircled by cytoplasm‐emitting two‐photon excited fluorescence signals. Nerve fibres and neuroglias were observed in white matter. Besides, the spinal arteries were clearly presented by NLO microscopy. Using spectral and morphological information, this technique was proved to be an effective tool for label‐freely imaging spinal cord tissues, based on endogenous signals in biological tissue. With future development, we foresee promising applications of the NLO technique for in vivo, real‐time assessment of spinal cord diseases or injures.  相似文献   

10.
11.
Multiphoton fluorescence excitation microscopy is almost invariably conducted with samples whose refractive index differ from that of the objective immersion medium, conditions that cause spherical aberration. Due to the quadratic nature of multiphoton fluorescence excitation, spherical aberration is expected to profoundly affect the depth dependence of fluorescence excitation. In order to determine the effect of refractive index mismatch in multiphoton fluorescence excitation microscopy, we measured signal attenuation, photobleaching rates and resolution degradation with depth in homogeneous samples with minimal light scattering and absorption over a range of refractive indices. These studies demonstrate that signal levels and resolution both rapidly decline with depth into refractive index mismatched samples. Analyses of photobleaching rates indicate that the preponderance of signal attenuation with depth results from decreased rates of fluorescence excitation, even in a system with a descanned emission collection pathway. Similar results were obtained in analyses of fluorescence microspheres embedded in rat kidney tissue, demonstrating that spherical aberration is an important limiting factor in multiphoton fluorescence excitation microscopy of biological samples.  相似文献   

12.
In this study, we combined two-photon autofluorescence and second harmonic generation imaging to investigate the three-dimensional microstructure and nonlinear optical properties of tissue engineering scaffolds. We focused on five different types of scaffold materials commonly used in tissue engineering, including: open-cell polylactic acid, polyglycolic acid, collagen composite scaffold, collagraft bone graft matrix strip, and nylon. By the use of multiphoton microscopy and a motorized stage, we obtained high resolution, spectrally resolved structural information of the scaffolds over large areas or in three-dimensions. Our results show that the nonlinear optical properties of the scaffolds will enable us to spectrally and morphologically distinguish the different types of scaffold materials investigated. We envision multiphoton microscopy to be a useful technique in tissue engineering applications in understanding the interplay between cultured cells and the scaffold materials.  相似文献   

13.
Nonlinear optical microscopy (NLOM) was used as a noninvasive and label‐free tool to detect and quantify the extent of the cartilage recovery. Two cartilage injury models were established in the outer ears of rabbits that created a different extent of cartilage recovery based on the presence or absence of the perichondrium. High‐resolution NLOM images were used to measure cartilage repair, specifically through spectral analysis and image texture. In contrast to a wound lacking a perichondrium, wounds with intact perichondria demonstrated significantly larger TPEF signals from cells and matrix, coarser texture indicating the more deposition of type I collagen. Spectral analysis of cells and matrix can reveal the matrix properties and cell growth. In addition, texture analysis of NLOM images showed significant differences in the distribution of cells and matrix of repaired tissues with or without perichondrium. Specifically, the decay length of autocorrelation coefficient based on TPEF images is 11.2 ± 1.1 in Wound 2 (with perichondrium) and 7.5 ± 2.0 in Wound 1 (without perichondrium), indicating coarser image texture and faster growth of cells in repaired tissues with perichondrium (p < 0.05). Moreover, the decay length of autocorrelation coefficient based on collagen SHG images also showed significant difference between Wound 2 and 1 (16.2 ± 1.2 vs. 12.2 ± 2.1, p < 0.05), indicating coarser image texture and faster deposition of collagen in repaired tissues with perichondrium (Wound 2). These findings suggest that NLOM is an ideal tool for studying cartilage repair, with potential applications in clinical medicine. NLOM can capture macromolecular details and distinguish between different extents of cartilage repair without the need for labelling agents.  相似文献   

14.
Zhuo S  Chen J  Jiang X  Luo T  Chen R  Xie S  Zou Q 《Scanning》2007,29(5):219-224
We demonstrate the technique of subsequent multitrack nonlinear imaging based on backscattered second-harmonic generation (B-SHG) and two-photon autofluorescence (TPA) to obtain large-area, high-contrast, submicron-resolution image ex vivo of esophageal stroma. Our findings show that this technique is effective in improving the B-SHG/TPA image contrast. It was found that the method can quantitatively obtain microscopic structural and biochemical information on stroma. Our work suggests that the technique has the potential to provide accurate and comprehensive information in determining the physiological and pathological states of the esophagus.  相似文献   

15.
Background : Multifunctional two‐photon laser scanning microscopy provides attractive advantages over conventional two‐photon laser scanning microscopy. For the first time, simultaneous measurement of the second harmonic generation (SHG) signals in the forward and backward directions and two photon excitation fluorescence were achieved from the deep shade plant Selaginella erythropus. Results : These measurements show that the S. erythropus leaves produce high SHG signals in both directions and the SHG signals strongly depend on the laser's status of polarization and the orientation of the dipole moment in the molecules that interact with the laser light. The novelty of this work is (1) uncovering the unusual structure of S. erythropus leaves, including diverse chloroplasts, various cell types and micromophology, which are consistent with observations from general electron microscopy; and (2) using the multifunctional two‐photon laser scanning microscopy by combining three platforms of laser scanning microscopy, fluorescence microscopy, harmonic generation microscopy and polarizing microscopy for detecting the SHG signals in the forward and backward directions, as well as two photon excitation fluorescence. Conclusions : With the multifunctional two‐photon laser scanning microscopy, one can use noninvasive SHG imaging to reveal the true architecture of the sample, without photodamage or photobleaching, by utilizing the fact that the SHG is known to leave no energy deposition on the interacting matter because of the SHG virtual energy conservation characteristic.  相似文献   

16.
Ultrafast lasers have found increasing use in scanning optical microscopy due to their very high peak power in generating multiphoton excitations. A mode-locked Ti:sapphire laser is often employed for such purposes. Together with a synchronously pumped optical parametric oscillator (OPO), the spectral range available can be extended to 1,050-1,300 nm. This broader range available greatly facilitates the excitation of second harmonic generation (SHG) and third harmonic generation (THG) due to better satisfaction of phase matching condition that is achieved with a longer excitation wavelength. Dental sections are then investigated with the contrasts from harmonic generation. In addition, through intra-cavity doubling wavelengths from 525-650 nm are made available for effective two-photon (2-p) excitation with the equivalent photon energy in the UVB range (290-320 nm) and beyond. This new capacity allows UV (auto-) fluorescence excitation and imaging, for example, from some amino acids, such as tyrosine, tryptophan, and glycine.  相似文献   

17.
A variety of high resolution optical microscopy techniques have been developed in recent years for basic and clinical studies of biological systems. We demonstrate a trimodal microscope combining optical coherence microscopy (OCM) with two forms of nonlinear microscopy, namely two-photon excited fluorescence (2PF) and second harmonic generation (SHG), for imaging turbid media. OCM combines the advantages of confocal detection and coherence gating for structural imaging in highly scattering tissues. Nonlinear microscopy enables the detection of biochemical species, such as elastin, NAD(P)H, and collagen. While 2PF arises from nonlinear excitation of fluorescent species, SHG is a form of nonlinear scattering observed in materials that lack a center of inversion symmetry, such as type I collagen. Characterization of the microscope showed nearly diffraction-limited spatial resolution in all modalities. Images were obtained in fish scales and excised human skin samples. The primary endogenous sources of contrast in the dermis were due to elastin autofluorescence and collagen SHG. Multimodal microscopy allows the simultaneous visualization of structural and functional information of biological systems.  相似文献   

18.
A benefit of multiphoton fluorescence microscopy is the inherent optical sectioning that occurs during excitation at the diffraction-limited spot. The scanned collection of fluorescence emission is incoherent; that is, no real image needs to be formed on the detector plane. The nearly isotropic emission of fluorescence excited at the focal spot allows for new detection schemes that efficiently funnel all attainable photons to detector(s). We previously showed [Combs, C.A., et al. (2007) Optimization of multiphoton excitation microscopy by total emission detection using a parabolic light reflector. J. Microsc. 228, 330-337] that parabolic mirrors and condensers could be combined to collect the totality of solid angle around the excitation spot for tissue blocks, leading to ~8-fold signal gain. Using a similar approach, we have developed an in vivo total emission detection (epiTED) instrument modified to make noncontact images from outside of living tissue. Simulations suggest that a ~4-fold enhancement may be possible (much larger with lower NA objectives than the 0.95 NA used here) with this approach, depending on objective characteristics, imaging depth and the characteristics of the sample being imaged. In our initial prototype, 2-fold improvements were demonstrated in the mouse brain and skeletal muscle as well as the rat kidney, using a variety of fluorophores and no compromise of spatial resolution. These results show this epiTED prototype effectively doubles emission signal in vivo; thus, it will maintain the image signal-to-noise ratio at two times the scan rate or enable full scan rate at approximately 30% reduced laser power (to minimize photo-damage).  相似文献   

19.
Sun CK  Chu SW  Tai SP  Keller S  Abare A  Mishra UK  DenBaars SP 《Scanning》2001,23(3):182-192
Taking advantage of the electric field-enhanced second-harmonic generation effect in bulk gallium nitride (GaN) and indium gallium nitride (InGaN) quantum wells, we demonstrated the piezoelectric field distribution mapping in bulk GaN and InGaN multiple-quantum-well (MQW) samples using scanning second-harmonic generation (SHG) microscopy. Scanning SHG microscopy and the accompanying third-harmonic generation (THG) microscopy of the bulk GaN sample were demonstrated using a femtosecond Cr:forsterite laser at a wavelength of 1230 nm. Taking advantage of the off-resonant electric field-enhanced SHG effect and the bandtail state-resonance THG effect, the second- and third-harmonic generation microscopic images obtained revealed the piezoelectric field and bandtail state distributions in a GaN sample. Combined with 720 nm wavelength excited two-photon fluorescence microscopy in the same sample, the increased defect density around the defect area was found to suppress bandedge photoluminescence, to increase yellow luminescence, to increase bandtail state density, and to decrease residue piezoelectric field intensity. Scanning SHG microscopy of the InGaN MQW sample was resonant excited with 800 nm femtosecond pulses from a Ti:sapphire laser in order to suppress SHG contribution from the bulk GaN substrate. Taking advantage of the strong piezoelectric field inside the InGaN quantum well, the wavelength resonant effect, and the electric field-enhanced SHG effect of InGaN quantum wells, resonant scanning SHG microscopy revealed the piezoelectric field distribution inside the wells. Combined with accompanying three-photon fluorescence microscopy from the bulk GaN substrate underneath the quantum wells, the direct correspondence between the piezoelectric field strength inside the quantum well and the substrate quality can be obtained. According to our study, the GaN substrate area with bright bandedge luminescence corresponds to the area with strong SHG signals indicating a higher stained-induced piezoelectric field. These scanning harmonic generation microscopies exhibit superior images of the piezoelectric field and defect state distributions in GaN and InGaN MQWs not available before. Combining with scanning multiphoton fluorescence microscopy, these techniques open new ways for the physical property study of this important material system and can provide interesting details that are not readily available by other microscopic techniques.  相似文献   

20.
Huang Z  Zhuo S  Chen J  Chen R  Jiang X 《Scanning》2008,30(6):452-456
The fresh adipose tissue was investigated by the use of multiphoton microscopy (MPM) based on two-photon excited fluorescence and second-harmonic generation (SHG). Microstructure of collagen and adipose cells in the adipose tissue is clearly imaged at a subcellular level with the excitation light wavelengths of 850 and 730 nm, respectively. The emission spectrum of collagen SHG signal and NADH and FAD fluorescence signal can also be obtained, which can be used to quantify the content of collagen and adipose cells and reflect the degree of pathological changes when comparing normal tissue with abnormal adipose tissue in the same condition. The results indicate that MPM has the potential to be applied to investigate the adipose tissue and can be used in the research field of lipid and connective tissues.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号