首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
基于自适应形态滤波的医学超声图像降噪   总被引:3,自引:0,他引:3  
针对医学超声图像上的斑点噪声,本文提出一种基于自适应形态滤波的降噪方法.首先构造一组检测图像中不同像素值突变的结构因子;再对每个结构因子构造相应的形态滤波结构元;最后对每个像素点邻域进行结构检测,找到该点处最可能存在的突变结构,以相应的结构元完成该点的形态滤波.对不同信噪比的仿真图像和实际图像分别采用本文方法和各向异性扩散滤波,不同尺度传统形态滤波进行了:比较实验,结果表明:采用本方法可将超声图像的信噪比、对比度噪声比和图像优度分别平均提高15%、37%和69%,优于其它方法.  相似文献   

2.
Spatial filters that mimic receptive fields of visual cortex neurons provide an efficient representation of achromatic image structure, but the extension of this idea to chromatic information is at an early stage. Relatively few studies have looked at the statistical relationships between the modeled responses to natural scenes of the luminance (LUM), red-green (RG), and blue-yellow (BY) postreceptoral channels of the primate visual system. Here we consider the correlations among these channel responses in terms of pixel, first-order, and second-order information. First-order linear filtering was implemented by convolving the cosine-windowed images with oriented Gabor functions, whose gains were scaled to give equal amplitude response across spatial frequency to random fractal images. Second-order filtering was implemented via a filter-rectify-filter cascade, with Gabor functions for both first- and second-stage filters. Both signed and unsigned filter responses were obtained across a range of filter parameters (spatial frequency, 2-64 cycles/image; orientation, 0-135 degrees). The filter responses to the LUM channel images were larger than those for either RG or BY channel images. Cross correlations between the first-order channel responses and between the first- and second-order channel responses were measured. Results showed that the unsigned correlations between first-order channel responses were higher than expected on the basis of previous studies and that first-order channel responses were highly correlated with LUM, but not with RG or BY, second-order responses. These findings imply that course-scale color information correlates well with course-scale changes of fine-scale texture.  相似文献   

3.
4.
We propose a new algorithm for real-time, adaptive-clutter-rejection filtering in ultrasound color flow imaging (CFI) and related techniques. The algorithm is based on regression filtering using eigenvectors of the signal correlation matrix as a basis for representing clutter, a method that previously has been considered too computationally demanding for real-time processing in general CFI applications. The data acquisition and processing scheme introduced allows for a more localized sampling of the clutter statistics and, therefore, an improved clutter attenuation for lower filter orders. By using the iterative power method technique, the dominant eigenvalues and corresponding eigenvectors of the correlation matrix can be estimated efficiently, rendering real-time operation feasible on desktop computers. A new adaptive filter order algorithm is proposed that successfully estimates the proper dimension of the clutter basis, previously one of the major drawbacks of this clutter-rejection technique. The filter algorithm performance and computational demands has been compared to that of conventional clutter filters. Examples have been included which confirms that, by adapting the clutter-rejection filter to estimates of the clutter-signal statistics, improved attenuation of the clutter signal can be achieved in normal as well as more excessive cases of tissue movement and acceleration.  相似文献   

5.
Noise corrupts ultrasound images and degrades spatial and contrast resolutions. Hence, it is challenging to characterize the lesions precisely using ultrasound images. The present study aims to evaluate 67 denoising filters and select the best one for ultrasound image denoising. Seven test images were synthesized to evaluate the performance of filters at three different noise levels. Eleven full-reference quantitative image quality metrics (IQMs) were employed to evaluate the performance of the filters. A new filter evaluation method, Rank Analysis, was introduced and utilized at each noise level. The ten best filters with the smallest mean rank in all noise levels were defined for further analysis on real ultrasound images. The Rank Analysis was also employed for real ultrasound images, and filters were evaluated based on 14 IQMs (11 full-reference and three no-reference). Finally, the best filter was defined using the repeated measures analysis statistical test. According to the Rank Analysis results, the Spatial correlation (SCorr) filter obtained the best results with the mean rank scores±SD of 1 ± 0, which was significantly better than the other nine filters (p < 0.001). The second-best results were achieved by three filters, Bitonic, most homogeneous neighborhood, and Lee diffusion (p < 0.05). We concluded that SCorr is the best filter for ultrasound image denoising. It can be used in the pre-processing step before segmentation and diagnostic procedures. In addition, a new filter evaluation method, Rank Analysis, was introduced in this study, which is easy to use, fast, and provides reliable results. So, it can be used to evaluate newly developed filters in the future studies.  相似文献   

6.
B-mode ultrasound images are characterized by speckle artifact, which may make the interpretation of images difficult. One widely used method for ultrasound speckle reduction is the split spectrum processing (SSP), but the use of one-dimensional (1-D), narrow-band filters makes the resultant image experience a significant resolution loss. In order to overcome this critical drawback, we propose a novel method for speckle reduction in ultrasound medical imaging, which uses a bank of wideband 2-D directive filters, based on modified Gabor functions. Each filter is applied to the 2-D radio-frequency (RF) data, resulting in a B-mode image filtered in a given direction. The compounding of the filters outputs give rise to a final image in which speckle is reduced and the structure is enhanced. We have denoted this method as directive filtering (DF). Because the proposed filters have effectively the same bandwidth as the original image, it is possible to avoid the resolution loss caused by the use of narrow-band filters, as with SSP. The tests were carried out with both simulated and real clinical data. Using the signal-to-noise ratio (SNR) to quantify the amount of speckle of the ultrasound images, we have achieved an average SNR enhancement of 2.26 times with simulated data and 1.18 times with real clinical data.  相似文献   

7.
This paper, the first from a series of three papers on the application of coded excitation signals in medical ultrasound, discusses the basic principles and ultrasound-related problems of pulse compression. The concepts of signal modulation and matched filtering are given, and a simple model of attenuation relates the matched filter response with the ambiguity function, known from radar. Based on this analysis and the properties of the ambiguity function, the selection of coded waveforms suitable for ultrasound imaging is discussed. It is shown that linear frequency modulation (FM) signals have the best and most robust features for ultrasound imaging. Other coded signals such as nonlinear FM and binary complementary Golay codes also have been considered and characterized in terms of signal-to-noise ratio (SNR) and sensitivity to frequency shifts. Using the simulation program Field II, it is found that in the case of linear FM signals, a SNR improvement of 12 to 18 dB can be expected for large imaging depths in attenuating media, without any depth-dependent filter compensation. In contrast, nonlinear FM modulation and binary codes are shown to give a SNR improvement of only 4 to 9 dB when processed with a matched filter. Other issues, such as depth-dependent matched filtering and use of filters other than the matched filter (inverse and Wiener filters) also are addressed.  相似文献   

8.
Ocular aberration correction can significantly improve visual function of the human eye. However, even under ideal aberration correction conditions, pupil diffraction restricts the resolution of retinal images. Pupil filtering is a simple super-resolution (SR) method that can overcome this diffraction barrier. In this study, a 145-element piezoelectric deformable mirror was used as a pupil phase filter because of its programmability and high fitting accuracy. Continuous phase-only filters were designed based on Zernike polynomial series and fitted through closed-loop adaptive optics. SR results were validated using double-pass point spread function images. Contrast sensitivity was further assessed to verify the SR effect on visual function. An F-test was conducted for nested models to statistically compare different CSFs. These results indicated CSFs for the proposed SR filter were significantly higher than the diffraction correction (p < 0.05). As such, the proposed filter design could provide useful guidance for supernormal vision optical correction of the human eye.  相似文献   

9.
宋海平  卢战伟  赵松 《影像技术》2011,(5):39-44,13
本文阐述了Boxcar滤波器和极化Refined Lee滤波器的滤波原理,比较了两种滤波器的滤波效果。通过滤波后的极化图像分类精度的比较发现,滤波能显著提高监督分类的精度,滤波是提高分类精度必不可少的技术环节,Boxcar滤波在提高分类精度方面要优于Refined Lee滤波,此外滤波窗口的大小对分类精度也有重要的影响。  相似文献   

10.
黄启宏  刘钊 《光电工程》2007,34(3):98-104
在纹理分类中采用谱直方图表示(SHR),每个图像窗表示一个包含滤波后图像直方图的特征向量,而直方图是图像谱表示的连接桥梁.在滤波器选择算法之前,结合每个图像分块和滤波器的独立谱表示和直方图,可以获得更加低层的局部特征.最后,时所有独立滤波器采用滤波器选择算法来得到所需的少量滤波器.为了保证分类的可靠性,选择高斯径向基函数(RBF)进行谱直方图表示,采用支持向量机(SVMs)作为分类函数.对本文方法和其它两种方法:Gabor滤波和独立成分分析(ICA)进行了纹理分类和脸部识别的比较实验.实验结果表明,本文方法具有更高的分类准确性,也证明了SVMs优秀的泛化能力.  相似文献   

11.
本文阐述了Boxcar滤波器和极化Refined Lee滤波器的滤波原理,比较了两种滤波器的滤波效果.通过滤波后的极化图像分类精度的比较发现,滤波能显著提高监督分类的精度,滤波是提高分类精度必不可少的技术环节,Boxcar滤波在提高分类精度方面要优于Refined Lee滤波,此外滤波窗口的大小对分类精度也有重要的影响.  相似文献   

12.
Takaki Y  Ishida K  Kume Y  Ohzu H 《Applied optics》1996,35(17):3134-3140
Incoherent pattern detection by a simple imaging system using a liquid-crystal active lens is proposed. The imaging system works as a spatial filtering system with a rewritable phase-only filter. We found that, in the incoherent matched filtering system, a conventional phase-only filter has a higher optical efficiency but a lower pattern discrimination than a complex filter. To improve the pattern discrimination ability, we optimized the phase-only filter by using simulated annealing and a genetic algorithm. We designed phase-only filters that have discrimination ability comparable with that in a complex filter. The performance of optimized phase-only filters is experimentally demonstrated.  相似文献   

13.
Clutter filter design for ultrasound color flow imaging   总被引:7,自引:0,他引:7  
For ultrasound color flow images with high quality, it is important to suppress the clutter signals originating from stationary and slowly moving tissue sufficiently. Without sufficient clutter rejection, low velocity blood flow cannot be measured, and estimates of higher velocities will have a large bias. The small number of samples available (8 to 16) makes clutter filtering in color flow imaging a challenging problem. In this paper, we review and analyze three classes of filters: finite impulse response (FIR), infinite impulse response (IIR), and regression filters. The quality of the filters was assessed based on the frequency response, as well as on the bias and variance of a mean blood velocity estimator using an autocorrelation technique. For FIR filters, the frequency response was improved by allowing a non-linear phase response. By estimating the mean blood flow velocity from two vectors filtered in the forward and backward direction, respectively, the standard deviation was significantly lower with a minimum phase filter than with a linear phase filter. For IIR filters applied to short signals, the transient part of the output signal is important. We analyzed zero, step, and projection initialization, and found that projection initialization gave the best filters. For regression filters, polynomial basis functions provide effective clutter suppression. The best filters from each of the three classes gave comparable bias and variance of the mean blood velocity estimates. However, polynomial regression filters and projection-initialized IIR filters had a slightly better frequency response than could be obtained with FIR filters  相似文献   

14.
Rangayyan RM  Ciuc M  Faghih F 《Applied optics》1998,37(20):4477-4487
In many image-processing applications the noise that corrupts the images is signal dependent, the most widely encountered types being multiplicative, Poisson, film-grain, and speckle noise. Their common feature is that the power of the noise is related to the brightness of the corrupted pixel. This results in brighter areas appearing to be noisier than darker areas. We propose a new adaptive-neighborhood approach to filtering images corrupted by signal-dependent noise. Instead of using fixed-size, fixed-shape neighborhoods, statistics of the noise and the signal are computed within variable-size, variable-shape neighborhoods that are grown for every pixel to contain only pixels that belong to the same object. Results of adaptive-neighborhood filtering are compared with those given by two local-statistics-based filters (the refined Lee filter and the noise-updating repeated Wiener filter), both in terms of subjective and objective measures. The adaptive-neighborhood approach provides better noise suppression as indicated by lower mean-squared errors as well as better retention of edge sharpness than the other approaches considered.  相似文献   

15.
Image filtering techniques have numerous potential applications in biomedical imaging and image processing. The design of filters largely depends on the a priori, knowledge about the type of noise corrupting the image. This makes the standard filters application specific. Widely used filters such as average, Gaussian, and Wiener reduce noisy artifacts by smoothing. However, this operation normally results in smoothing of the edges as well. On the other hand, sharpening filters enhance the high-frequency details, making the image nonsmooth. An integrated general approach to design a finite impulse response filter based on Hebbian learning is proposed for optimal image filtering. This algorithm exploits the interpixel correlation by updating the filter coefficients using Hebbian learning. The algorithm is made iterative for achieving efficient learning from the neighborhood pixels. This algorithm performs optimal smoothing of the noisy image by preserving high-frequency as well as low-frequency features. Evaluation results show that the proposed finite impulse response filter is robust under various noise distributions such as Gaussian noise, salt-and-pepper noise, and speckle noise. Furthermore, the proposed approach does not require any a priori knowledge about the type of noise. The number of unknown parameters is few, and most of these parameters are adaptively obtained from the processed image. The proposed filter is successfully applied for image reconstruction in a positron emission tomography imaging modality. The images reconstructed by the proposed algorithm are found to be superior in quality compared with those reconstructed by existing PET image reconstruction methodologies.  相似文献   

16.
In the first paper, the superiority of linear FM signals was shown in terms of signal-to-noise ratio and robustness to tissue attenuation. This second paper in the series of three papers on the application of coded excitation signals in medical ultrasound presents design methods of linear FM signals and mismatched filters, in order to meet the higher demands on resolution in ultrasound imaging. It is shown that for the small time-bandwidth (TB) products available in ultrasound, the rectangular spectrum approximation is not valid, which reduces the effectiveness of weighting. Additionally, the distant range sidelobes are associated with the ripples of the spectrum amplitude and, thus, cannot be removed by weighting. Ripple reduction is achieved through amplitude or phase predistortion of the transmitted signals. Mismatched filters are designed to efficiently use the available bandwidth and at the same time to be insensitive to the transducer's impulse response. With these techniques, temporal sidelobes are kept below 60 to 100 dB, image contrast is improved by reducing the energy within the sidelobe region, and axial resolution is preserved. The method is evaluated first for resolution performance and axial sidelobes through simulations with the program Field II. A coded excitation ultrasound imaging system based on a commercial scanner and a 4 MHz probe driven by coded sequences is presented and used for the clinical evaluation of the coded excitation/compression scheme. The clinical images show a significant improvement in penetration depth and contrast, while they preserve both axial and lateral resolution. At the maximum acquisition depth of 15 cm, there is an improvement of more than 10 dB in the signal-to-noise ratio of the images. The paper also presents acquired images, using complementary Golay codes, that show the deleterious effects of attenuation on binary codes when processed with a matched filter, also confirmed by presented simulated images.  相似文献   

17.
We present a new algorithm for deriving a second-order Volterra filter (SVF) capable of separating linear and quadratic components from echo signals. Images based on the quadratic components are shown to provide contrast enhancement between tissue and ultrasound contrast agents (UCAs) without loss in spatial resolution. It is also shown that the quadratic images preserve the low scattering regions due to their high dynamic range when compared with standard B-mode or harmonic images. A robust algorithm for deriving the filter has been developed and tested on real-time imaging data from contrast and tissue-mimicking media. Illustrative examples from image targets containing contrast agent and tissue-mimicking media are presented and discussed. Quantitative assessment of the contrast enhancement is performed on both the RF data and the envelope-detected log-compressed image data. It is shown that the quadratic images offer levels of enhancement comparable or exceeding those from harmonic filters while maintaining the visibility of low scattering regions of the image.  相似文献   

18.
A new fast adaptive high-performance filter (FAHPF) has been proposed to remove salt-and-pepper noise in images. ‘Maximize the speed without compromising denoising performance’ is the fundamental intention to build up the FAHPF algorithm. Among diverse phases of filtering employed in the FAHPF, overlapping medians (OM) is our newly proposed frame-based filtering concept which is the basis for speed of FAHPF and running averages embedded with OM is an idea behind excellent denoising performance of FAHPF at the same pace. Simulation experiments have been conducted and denoising results of FAHPF has been investigated against very recently developed filtering methods. It is proved that the FAHPF excellently outperforms many of state-of-the-art filters considered for comparison, in terms of peak signal to noise ratio, structural similarity index, and visual representation and requires the extremely shortest execution time among all, which could make it as a real time filter.  相似文献   

19.
基于Gabor滤波系数高阶矩的图像检索   总被引:1,自引:0,他引:1  
在分析Gabor滤波器进行图像纹理特征提取的基础上,提出了利用多尺度和多方向Gabor滤波系数的高阶矩提取图像特征进行CBIR的方法,利用滤波系数的方差给出了基于Gabor滤波组提取的图像纹理特征的平滑度和纹理一致性算法,并采用四个尺度和六个方向的滤波系数的能量、方差、峰态、平滑度和一致性组成了CBIR特征向量.采用Brodatz纹理库和Corel图像库中的典型图像进行了对比实验.实验证明,提出的方法比传统的Gabor滤波进行CBIR具有更高的查准率.  相似文献   

20.
Capon beamforming in medical ultrasound imaging with focused beams   总被引:1,自引:0,他引:1  
Medical ultrasound imaging is conventionally done by insonifying the imaged medium with focused beams. The backscattered echoes are beamformed using delay-and-sum operations that cannot completely eliminate the contribution of signals backscattered by structures off the imaging beam to the beamsum. It leads to images with limited resolution and contrast. This paper presents an adaptation of the Capon beamformer algorithm to ultrasound medical imaging with focused beams. The strategy is to apply data-dependent weight functions to the imaging aperture. These weights act as lateral spatial filters that filter out off-axis signals. The weights are computed for each point in the imaged medium, from the statistical analysis of the signals backscattered by that point to the different elements of the imaging probe when insonifying it with different focused beams. Phantom and in vivo images are presented to illustrate the benefits of the Capon algorithm over the conventional delay and-sum approach. On heart sector images, the clutter in the heart chambers is decreased. The endocardium border is better defined. On abdominal linear array images, significant contrast and resolution enhancement are observed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号