首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The behaviour of oxidation at elevated tem-peratures and fretting in the laser-alloyed layer ofTi-6Al-4V with the addition of Pr was studied.The results show that the addition of Pr changes thestructure of oxide scale of Ti-6Al-4V,controls theshort-range diffusion of oxygen to thescale/substrate interface and increases the adhe-sion and ductility of the scale,thus changing theoxidation kinetics and considerably reducingoxidation rate.The analysis of fretting test showsthat the existence of high hardness layer in the al-loyed zone,fine dendrites perpendicular to the sur-face of the high hardness layer and the oxide scaleproduced during fretting at elevated temperaturesare all beneficial to the improvement of wear resist-ance.  相似文献   

2.
Effect of mean stress on fretting fatigue of Ti-6Al-4V on Ti-6Al-4V   总被引:1,自引:0,他引:1  
Fretting fatigue tests of Ti‐6Al‐4V on Ti‐6Al‐4V have been conducted to determine the influence of stress amplitude and mean stress on life. The stress ratio was varied from R=−1 to 0.8. Both flat and cylindrical contacts were studied using a bridge‐type fretting fatigue test apparatus operating either in the partial slip or mixed fretting regimes. The fretting fatigue lives were correlated to a Walker equivalent stress relation. The influence of mean stress on fretting fatigue crack initiation, characterized by the value of the Walker exponent, is smaller compared with plain fatigue. The fretting fatigue knockdown factor based on the Walker equivalent stress is 4. Formation of fretting cracks is primarily associated with the tangential force amplitude at the contact interface. A simple fretting fatigue crack initiation metric that is based on the strength of the singular stress field at the edge of contact is evaluated. The metric has the advantage in that it is neither dependent on the coefficient of friction nor the location of the stick/slip boundary, both of which are often difficult to define with certainty a priori.  相似文献   

3.
马秀丽  滕凯 《材料导报》2016,30(Z1):177-179, 190
针对机械切削性能差、难加工的Ti-6Al-4V合金,运用正交试验法进行了电火花线切割加工工艺试验研究。探讨了电火花线切割加工的规律和特性,分析了脉冲宽度、脉冲间隔、功放管数和运丝速度等工艺参数对Ti-6Al-4V加工质量的影响,得到了线切割加工最优化参数组合。借助L-M优化算法的BP神经网络搭建了线切割加工工艺网络预测模型,该模型预测精度较高,可为钛合金高质量切割提供可靠的工艺参数预测,对Ti-6Al-4V的实际生产加工具有一定的参考作用。  相似文献   

4.
采用TiZrNiCu合金作为中间层材料研究了Ti3Al基合金与Ti-6Al-4V合金的瞬间液相(TLP)扩散连接接头成分、组织转变及显微硬度.研究结果表明,连接温度和连接时间对接头成分和组织有较大的影响.随着连接温度的提高和连接时间的延长,接头中元素分布趋于均匀,连接区宽度增大.连接温度为850℃和900℃时,液相的残留使得接头中存在Ti-Cu金属间化合物.当连接温度为950℃,连接时间为30min时,等温凝固的完成使Ti-Cu金属间化合物从接头中消失.随着连接温度的提高和连接时间的延长,接头连接区硬度降低.当连接温度为950℃,连接时间为30min时,接头硬度分布较均匀.  相似文献   

5.
Titanium and its alloys are currently considered as one of the most important metallic materials used in the biomedical applications, due to their excellent mechanical properties and superior biocompatibility. In the present study, a new effective method for fabricating high porosity titanium alloy scaffolds was developed. Porous Ti-6Al-4V scaffolds are successfully fabricated with porosities ranging from 30% to 70% using spaceholder and powder sintering technique. Based on its acceptable properties, spherical carbamide particles with different diameters (0.56, 0.8, and 1mm) were used as the space-holder material in the present investigation. The Ti-6Al-4V scaffolds porosity is characterized by using scanning electron microscopy. The results show that the scaffolds spherical-shaped pores are depending on the shape, size and distribution of the space-holder particles. This investigation shows that the present new manufacturing technique is promising to fabricate a controlled high porosity and high purity Ti-6Al-4V scaffolds for hard tissue replacement.  相似文献   

6.
The effect of triple annealing on stress relaxation of Ti-6Al-4V alloy as well as the microstructure after stress relaxation werestudied. The results showed that triple annealing treatment enhanced the resistance of stress relaxation performance, andwhen the temperature was rising, this effect became notable. The stress relaxation deformation mechanism is of dislocationcreep at 400℃ and recovery creep at 600℃.  相似文献   

7.
The objective of this work was to compare the fretting fatigue performance of Ti‐6Al‐4V dovetail specimens on Ti‐6Al‐4V pads having various contact angles typical of engine hardware; 35°, 45° and 55° dovetail angles were considered. The dovetail fixtures were instrumented with strain gages so that the local normal and shear contact forces could be calculated. The contact force hysteresis loops were recorded showing the stick‐slip history. At R= 0.1, gross slip was observed for several thousand cycles followed by partial slip after the average coefficient of friction increased. At R= 0.5, gross slip was present only during the first half cycle. During partial slip, the slope of the shear versus normal force was a function of the dovetail angle. The local contact loads, therefore, differed for the same remotely applied force. Despite this, the fretting fatigue life depended primarily on the remotely applied load not dovetail angle.  相似文献   

8.
In SiC(f)/Ti-6Al-4V composites, the microstructure of the matrix close to the fiber was different from that of the fiber-less material. Microstructure observations show that a layer of fine grains was located adjacent to the fiber, and more dislocations and faults were found in this region. Higher recrystallization nucleation rate due to the undeformed SiC fiber and thermal residual stress induced during cooling from the fabrication temperature caused the microstructural changes of the matrix. Hardness measurement indicates that the matrix in the fiber neighborhood was strengthened, and the strengthening effect decreased with distance away from the fiber.  相似文献   

9.
1. IntroductionContinuous fiber-reinforced disordered titanium alloys and ordered titanium alloy matrix composites havreceived considerable attention as advanced aerospacstructural materials[1,2]. They possess unique combinations of several attractive properties such as high specifistiffness, high specific strength, excellent corrosion resistance, and good thermal stability etc. These novel materials can be applied in gas turbine engines, airframefor hypersonic aircraft, and advanced energy co…  相似文献   

10.
Present experimental investigation is directed toward the optimization of dressing infeed for silicon carbide (SiC) wheel to be employed for grinding difficult-to-machine super alloy Ti-6Al-4V. Grinding wheels are dressed using separate, however, identical 0.75 carat single point diamond dressers at 5, 10, 15, 20 and 25 µm infeed values. Differently dressed wheels are consequently, applied for grinding Ti-6Al-4V under different infeed values of 5, 10 and 15 µm. All the operations have been performed at a constant velocity of 1810 m/min. The performances of the differently dressed SiC wheels are evaluated based on the variations of grinding force components, average surface roughness values, grinding ratio, chip forms and based on the analyses of the micrographs of wheel topologies and also of the ground surfaces, obtained using scanning electron microscope. Following the performance evaluation, the optimized dressing infeed has been found to be 20 µm for the operation range considered herein.  相似文献   

11.
为研究除氢处理对置氢钛合金组织与性能的影响,对Ti-6Al-4V合金在不同参数条件下进行了置氢与除氢处理,采用光学显微镜分析了置氢-除氢处理过程中Ti-6Al-4V合金微观组织的演化规律,通过室温拉伸试验研究了置氢-除氢处理后Ti-6Al-4V合金的力学性能,探讨了Ti-6Al-4V合金置氢-除氢组织与力学性能之间的相...  相似文献   

12.
退火处理是改善钛合金显微组织,提高力学性能及超塑成形性能的一种重要工艺。使用真空退火炉在850℃-950℃温度区间内对锻态Ti-6Al-4V合金的进行了高温退火处理,研究了退火态Ti-6Al-4V合金微观组织演变及其在温度为900℃,应变速率为0.01 s-1时的超塑拉伸性能。结果表明,锻态Ti-6Al-4V合金的初生α晶粒尺寸随真空退火温度的升高而减小,β相比例随真空退火温度升高而增大。当真空退火温度为910℃时,Ti-6Al-4V合金的晶粒尺寸和α相与β相分布较为均匀,其超塑拉伸试验结果表明,该合金表现出最佳的超塑拉伸性能,其拉伸延伸率达到785%,峰值应力仅为26.8 MPa。  相似文献   

13.
The titanium alloys are potential materials for high temperature applications in turbine components due to their very high temperature strength and lightweight properties. However, hot corrosion is a life-limiting factor when Ti alloys are exposed to different chemical environments at high temperature. In the present paper, hot corrosion behavior of Ti-6Al-4V (Ti-31) alloy in different salt environments viz. air, Na2SO4-60% V2O5 and Na2SO4-50% NaCl at 750 °C was studied. The parabolic rate constants were calculated for different environments from the thermo-gravimetric data obtained for the samples and they show that corrosion rate is minimum in air when compared to chemical environment. The scale formed on the samples upon hot corrosion was characterized by using X-ray diffraction (XRD), SEM, and EDAX analysis to understand the degradation mechanisms.  相似文献   

14.
This paper presents the results of an investiga-tion of the effect of hydrogen treatment onmicrostructures and tensile and low cycle fatigueproperties of a Ti-6Al-4V cast alloy.The phasetransformation and the refining mechanism of thecast microstructure during the process of hydrogentreatment were studied.It was found that afterhydrogen treatment,the coarse Widmanstttenstructure of the as-cast Ti alloy was transformedinto a very fine and equiaxed α+β microstructurewithout any GBα phase.The tensile strength andductility and the low cycle fatigue life of thehydrogen treated specimens were significantly im-proved.  相似文献   

15.
Ti-6Al-4V等离子弧焊对接板超塑胀形特性研究   总被引:7,自引:0,他引:7  
通过自由胀形实验研究了等离子弧焊对接板的超塑胀形性能及影响因素.结果表明等离子弧焊对接板具有良好的超塑胀形性能,其极限胀形高度可超过凹模半径.在胀形过程中,焊缝组织发展成球状α 长条状α组织.焊缝和基体间存在变形不均匀性.在同样的胀形条件下,胀形气压有—最佳数值,气压过大或过小均降低极限胀形高度.最后给出了一个应用等离子弧焊对接板进行超塑胀形的实例.  相似文献   

16.
Microelectric-discharge milling is acquiring more importance in micromanufacturing because of its unique ability to produce three-dimensional microcavities with high aspect ratio in electrically conductive advanced materials regardless of its mechanical properties. The present study investigates the effects of major microelectric-discharge milling process variables [voltage (V), capacitance (C), electrode rotational speed (ERS), and feed rate (FR)] on Ti–6Al–4V. The output performance measures were identified as material removal rate (MRR) and tool wear rate (TWR) to assess the machinability of Ti–6Al–4V. Experiments were designed and carried out based on response surface methodology-Box-Behnken statistical design. The most influencing parameters for responses (MRR, TWR) were found to be capacitance and FR. At a capacitance of 0.4 µF and FR of 18 mm/min, maximum MRR of 0.9756 mg/h, and TWR of 0.6342 mg/h were observed. Similarly at 0.01 µF and 6 mm/min, minimum MRR of 0.2308 mg/h, and TWR of 0.1259 mg/h were obtained.  相似文献   

17.
Spherical Ti-6Al-4V powders were prepared using radio-frequency plasma spheroidization. A laser particle size analyser, a scanning electron microscope, an X-ray diffractometer and a Freeman FT4 powder rheometer were used to analyse the granulometric parameters, micro-morphologies, phase constitutions and flow properties of the raw and the spheroidized powders, respectively. The spheroidized powders exhibited an almost 100% degree of sphericity, smooth surfaces, favourable dispersion and narrow particle size distribution under appropriate plasma technological parameters. The average particle size of the spheroidized powders increased slightly as compared with that of the raw powders. In addition, the spheroidized powders exhibited higher conditioned bulk density and improved flow properties (including the dynamic flow properties, aeration, compressibility, permeability and shear properties) as compared with those of the raw powders.  相似文献   

18.
This paper discusses the failure analysis of a Ti-6Al-4V rotating main rotor component and contrasts the perspectives of the design/mechanical engineer and the manufacturing/materials engineer. Cracking initiated at mechanical marks located on the surface of the outer diameter of a planetary post at the transition radius and was propagated by high-cycle fatigue in service. These crack initiation defects were most likely produced by a machining or a surface finishing tool. Fractographic evidence suggests that high stresses were also encountered in service and played a significant role in the premature cracking of these components. The debate centers on whether the components would have failed in the absence of the surface defects. There were several manufacturers of this component, which are compared in this study. The workmanship on the outer diameter of the planetary post at the transition radius of a carrier that had not failed, manufactured by Company B, was superior to that of the two cracked carriers produced by Company A. However, analysis of the service conditions indicates that the components may have been loaded near the yield strength of the material.  相似文献   

19.
Surgical implant-associated bacterial infection is becoming a serious clinical problem.A series of copper-bearing titanium alloy,Ti—6AI—4V—xCu(x = 1,3,5 wt%),were fabricated in the present study in order to reduce the hazard of the bacterial infection problem by means of the strong antibacterial ability of Cu element.The metallography,X-ray diffraction,antibacterial ability,corrosion resistance and cytotoxicity of Ti—6AI—4V—xCu alloys were preliminarily studied with comparison to the commercial medical Ti—6AI—4V alloy.The Ti—6AI—4V—xCu alloys showed obvious antibacterial abilities with good corrosion resistance and cytocompatibility,and the antibacterial role was enhanced with increasing Cu content,which has significant potential for clinical applications as surgical implant materials.  相似文献   

20.
The oxygen concentration in commercial Ti-6Al-4?V alloys was reduced to less than 400?ppm in this study by the method of solid state re-deoxidation, using calcium as a reductant. The concentration of oxygen in the deoxidised Ti-6Al-4?V alloy was 630?ppm at the optimum deoxidation temperature of 1000°C. When the degree of vacuum was increased and re-deoxidation was carried out, the oxygen concentration decreased to 355?ppm. Therefore, it is possible to prepare a Ti-6Al-4?V alloy with an oxygen concentration of less than 400?ppm by using the solid state re-deoxidation method at a high degree of vacuum of 1.5?×?10-6 Torr.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号