首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 382 毫秒
1.
Wine production is seasonal, and thus the wastewater flow and its chemical oxygen demand (COD) concentrations greatly vary during the vintage and non-vintage periods, as well as being dependant on the winemaking technologies used, e.g. red, white or special wines production. Due to this seasonal high variability in terms of organic matter load, the use of membrane biological reactors (MBR) could be suitable for the treatment of such wastewaters. MBR offers several benefits, such as rapid start up, good effluent quality, low footprint area, absence of voluminous secondary settler and its operation is not affected by the settling properties of the sludge. A pilot scale hollow fibre MBR system of 220 L was fed by adequately diluting white wine with tap water, simulating wastewaters generated in wineries. The COD in the influent ranged between 1,000 and 4,000 mg/L. In less than 10 days after the start up, the system showed a good COD removal efficiency. The COD elimination percentage was always higher than 97% regardless of the organic loading rate (OLR) applied (0.5-2.2 kg COD/m3 d), with COD concentrations in the effluent ranging between 20 and 100 mg/L. Although the biomass concentration in the reactor increased from 0.5 to 8.6 g VSS/L, the suspended solids concentration in the effluent was negligible. Apparent biomass yield was estimated in 0.14 g VSS/g COD.  相似文献   

2.
This paper focuses on the evaluation of organic and detergent degradation in a combined Ozone/UF system for domestic laundry wastewater reclamation. Formation of by-product was investigated by GC/MS for the reclaimed water. Ozone was injected into the raw wastewater in a 10 L contact tank and the wastewater was circulated through the membrane module for inner pressurized cross-flow filtration. The concentrate was returned back to the contact tank. The membrane used in this experiment was hollow fiber polysulfone UF membrane with MWCO 10,000. It has an effective filtration area of 0.06 m2. The experiment was carried out with intermittent ozone injection, 5 min injection and 10 min idling. Ozone was dosed at the concentration of 1.5 mg/L. The flux of the UF could be maintained at 0.24 m/d under filtration pressure 40-45 kPa and water temperature, 20-22 degrees C. The organic removal efficiency by the system was 90% in terms of COD. Ozone was considerably effective to degrade organics in the wastewater. Molecular weight of organics in the raw waste was mostly greater than 10,000 (72% of 950 mgCOD/L). However 86% of effluent COD (94-100 mg/L) was composed of organics smaller than MWCO 500 by ozone injection. No harmful by-products by ozone contact were detected from the analysis of treated water using GC/MS. It was identified that residual organics in the treated water were 1,1'-Oxybisbenzene, Octadecanoic acid, Squalene and Benzenmethanol, etc., which were additives contained originally in the detergent. Consequently the reclaimed water quality could be estimated safe enough to recycle for the rinsing cycle in a washing machine.  相似文献   

3.
The objective of this study was to characterize the mechanisms of the COD removal in the membrane bioreactor (MBR) process with powdered activated carbon (PAC) addition and to determine its optimal operation, for the removal of residual organic matters (ROM) from biologically treated swine wastewater. The MBR process with PAC showed higher removal efficiency of chemical oxygen demand (COD(Mn)) than that without PAC. When the average COD(Mn) concentration of the influent was 217 mg/L, the average COD(Mn) concentration of the permeate from the MBR with PAC was about 41.5 mg/L, indicating an approximate removal efficiency of 81%. On the other hand, the average COD(Mn) concentration of the permeate from the MBR without PAC was 172 mg/L. The PAC dosage estimated to obtain the above removal efficiency was about 0.74 g per litre of influent. Among the total residual organics removed by PAC-added MBR, 46.5% was removed by PAC adsorption, 20.8% by biodegradation, 4.4% by membrane separation, and 9.3% by enhanced microorganism activity. From these results, the MBR process with PAC was considered as a very useful treatment process for the reduction of COD(Mn) in biologically treated swine wastewater.  相似文献   

4.
改进型移动床生物膜反应器处理有机废水的试验   总被引:1,自引:0,他引:1       下载免费PDF全文
改进型移动床生物膜反应器(CMCBR)是在普通移动床生物膜反应器中引入导流板,使填料在全池循环移动,消除了普通移动床生物膜反应器的死角。在CMCBR处理模拟生活污水的试验中,研究了有机物的去除效果,考察了容积负荷、水力停留时间、冲击负荷等参数对处理效果的影响。试验发现,在填料填充比例为50%(体积比),进水COD质量浓度为320~550mg/L,水力停留时间为3 h的条件下,出水COD质量浓度小于100 mg/L,达到国家污水综合排放标准的一级标准。反应器具有较强的抗冲击负荷能力,出水水质稳定。  相似文献   

5.
One of the major challenges of anaerobic technology is its applicability for low strength wastewaters, such as sewage. The lab-scale design and performance of a novel Gradual Concentric Chambers (GCC) reactor treating low (165+/-24 mg COD/L) and medium strength (550 mg COD/L) domestic wastewaters were studied. Experimental data were collected to evaluate the influence of chemical oxygen demand (COD) concentrations in the influent and the hydraulic retention time (HRT) on the performance of the GCC reactor. Two reactors (R1 and R2), integrating anaerobic and aerobic processes, were studied at ambient (26 degrees C) and mesophilic (35 degrees C) temperature, respectively. The highest COD removal efficiency (94%) was obtained when treating medium strength wastewater at an organic loading rate (OLR) of 1.9 g COD/L.d (HRT = 4 h). The COD levels in the final effluent were around 36 mg/L. For the low strength domestic wastewater, a highest removal efficiency of 85% was observed, producing a final effluent with 22 mg COD/L. Changes in the nutrient concentration levels were followed for both reactors.  相似文献   

6.
This work investigated the use of submerged anaerobic membrane bioreactors (SAMBRs) in the presence and absence of powdered activated carbon (PAC) for the treatment of genuine textile wastewater. The reactors were operated at 35 °C with an HRT of 24 h and the textile effluent was diluted (1:10) with nutrient solution containing yeast extract as the source of the redox mediation riboflavin. The results showed that although both SAMBRs exhibited an excellent performance, the presence of PAC inside SAMBR-1 enhanced reactor stability and removal efficiency of chemical oxygen demand (COD), volatile fatty acids (VFA), turbidity and color. The median removal efficiencies of COD and color in SAMBR-1 were, 90 and 94% respectively; whereas for SAMBR-2 (without PAC) these values were 79 and 86%, In addition, the median values of turbidity and VFA were 8 NTU and 8 mg/L for SAMBR-1 and 14 NTU and 26 mg/L for SAMBR-2, indicating that the presence of PAC inside SAMBR-1 led to the production of an anaerobic effluent of high quality regarding such parameters.  相似文献   

7.
The use of a membrane bioreactor (MBR) for removal of organic substances and nutrients from slaughterhouse plant wastewater was investigated. The chemical oxygen demand (COD), total nitrogen (TN), and total phosphorus (TP) concentrations of slaughterhouse wastewater were found to be approximately 571 mg O2/L, 102.5 mg/L, and 16.25 mg PO4-P/L, respectively. A submerged type membrane was used in the bioreactor. The removal efficiencies for COD, total organic carbon (TOC), TP and TN were found to be 97, 96, 65, 44% respectively. The COD value of wastewater was decreased to 16 mg/L (COD discharge standard for slaughterhouse plant wastewaters is 160 mg/L). TOC was decreased to 9 mg/L (TOC discharge standard for slaughterhouse plant wastewaters is 20 mg/L). Ammonium, and nitrate nitrogen concentrations of treated effluent were 0.100 mg NH4-N/L, and 80.521 mg NO3-N/L, respectively. Slaughterhouse wastewater was successfully treated with the MBR process.  相似文献   

8.
This paper presents the design and operational performance data of an anaerobic/aerobic hybrid side-stream Membrane Bioreactor (MBR) process for treating paper mill effluent operated over a 6 month period. The paper mill effluent stream was characterized by a chemical oxygen demand (COD) range of between 1,600 and 4,400 mg/L and an average BOD of 2,400 mg/L. Despite large fluctuations in COD feed concentration, stable process performance was achieved. The anaerobic Expanded Granular Sludge Bed (EGSB) pre-treatment step effectively lowered the organic loading by 65 to 85%, thus lowering the MBR COD feed concentration to consistently below 750 mg/L. The overall MBR COD removal was consistent at an average of 96%, regardless of the effluent COD or changes in the hydraulic retention time (HRT) and organic loading rate (OLR). Combining a high-rate anaerobic pre-treatment EGSB with a Modified Ludzack-Ettinger (MLE) MBR process configuration produced a high quality permeate. Preliminary NF and RO results indicated an overall COD removal of around 97 and 98%, respectively.  相似文献   

9.
The filtration characteristics of two different module configurations with coarse pore filter (non-woven fabric) were investigated for sludge floc separation in an activated sludge reactor for domestic wastewater reclamation. A polypropylene non-woven fabric filter (35 g/m2) was used for the two different module configurations, one flat and one tubular type, each with a filtration area of 0.052 m2. The different module types, submerged in the oxic compartment of A/O (anaerobic/oxic) type reactors, were operated simultaneously. The filtration fluxes were gradually increased from 0.5 to 1.2 and 1.73 m/d. The filtration pressures were more stably maintained for the tubular type module than the plate type. The tubular type module installed horizontally with two-side suction showed less filtration pressures than the tubular type module installed vertically with one-side suction. The solid separation was significantly high showing less than 5 mg/L effluent solids. The organic and T-N removal efficiencies were around 95 and 50%, respectively. The 85% removal of T-P was achieved with 20 mg/L injection of PAC (poly-aluminum chloride).  相似文献   

10.
生物过滤氧化反应器处理生活污水中试研究   总被引:3,自引:0,他引:3  
以生活污水为处理对象 ,研究了生物过滤氧化反应器 (BIOFOR)在高滤速、高负荷、小的气水比情况下 ,用非常短的水力停留时间 (6 0~ 80min) ,取得了很好的出水水质的机理 ,主要水质指标 (COD、BOD、SS、氨氮 )可达到国家《污水综合排放标准》或《生活杂用水水质标准》。同时探讨了滤速及容积负荷对出水水质的影响 ,分析了主要污染物的去除规律。  相似文献   

11.
This research project aimed to determine the technologically feasible and applicable wastewater treatment systems which will be constructed to solve environmental problems caused by small communities in Turkey. Pilot-scale treatment of a small community's wastewater was performed over a period of more than 2 years in order to show applicability of these systems. The present study involves removal of organic matter and suspended solids in serially operated horizontal (HFCW) and vertical (VFCW) sub-surface flow constructed wetlands. The pilot-scale wetland was constructed downstream of anaerobic reactors at the campus of TUBITAK-MRC. Anaerobically pretreated wastewater was introduced into this hybrid two-stage sub-surface flow wetland system (TSCW). Wastewater was first introduced into the horizontal sub-surface flow system and then the vertical flow system before being discharged. Recirculation of the effluent was tested in the system. When the recirculation ratio was 100%, average removal efficiencies for TSCW were 91 +/- 4% for COD, 83 +/- 10% for BOD and 96 +/- 3% for suspended solids with average effluent concentrations of 9 +/- 5 mg/L COD, 6 +/- 3 mg/L BOD and 1 mg/L for suspended solids. Comparing non-recirculation and recirculation periods, the lowest effluent concentrations were obtained with a 100% recirculation ratio. The effluent concentrations met the Turkish regulations for discharge limits of COD, BOD and TSS in each case. The study showed that a hybrid constructed wetland system with recirculation is a very effective method of obtaining very low effluent organic matter and suspended solids concentrations downstream of anaerobic pretreatment of domestic wastewaters in small communities.  相似文献   

12.
The aim of this study was to develop the optimum integrated treatment system for slurry type swine wastewater through field testing. Although composting and liquid composting are the most desirable processes to treat swine wastewater, inadequate composting has been blamed as critical non-point source pollutants. In the area with limited crop land and grass land, the most feasible method to handle slurry type swine wastewater would be that the solids portion from the solids/liquid separation process is treated by composting and then the liquid portion is treated by a series of wastewater treatment processes, including physicochemical treatment system and biological nutrient removal systems such as the modified Ludzack Ettinger (MLE) process and MLE process coupled with a membrane, to satisfy the different effluent criteria. When using the appropriate solids/liquid separation system, the removal efficiency of SS, COD(Cr), and TKN was 92.4%, 73.6%, and 46.0%, respectively and the amount of bulking agent required for composting and organic loading rate for the following wastewater treatment system can be reduced by 94.8% and 84.7%, respectively. When treating the effluent from solids/liquid separation process by MLE process, the optimal volume fraction for denitrification was 20% of total reactor volume and the optimum ratio of F/M and F(N)/M were increased with increase of C/N ratio. Since the effluent quality of MLE process is not enough to discharge, the DAF process was operated with addition of FeCl3 and cationic polyelectrolyte. The effluent from the DAF process was treated in the MLE process coupled with a crossflow ultrafiltration membrane to satisfy more stringent effluent criteria. When external carbon source is added to keep 6.0 of C/N ratio, the efficiency of denitrification is best. The optimum linear velocity and transmembrane pressure for MBR process was 1.8 m/sec and 2.1 atm, respectively. By addition of external carbon source, nitrogen compounds, especially NOx-N, were considerably removed. And by addition of powdered activated carbon, the removal efficiency of COD(Cr) and COD(Mn) and the membrane flux were increased dramatically.  相似文献   

13.
The particles from carwash wastewater were separated by a hollow fiber membrane aided by a enhanced coagulation and activated carbon. This study demonstrated that the addition of KMnO(4) to coagulant (PAC) could enhance the efficiency of coagulation, which helped reduce clogging of the ultrafiltration membrane and activated carbon. The existence of LAS can loosen the gel layer on the membrane and improve the flux. Adsorption of particles such as organic matter and oil is the main reason causing membrane flux decrease. When carwash wastewater was pretreated, the permeation flux of membrane showed a higher value. LAS, odour and colour are removed by GAC adsorption treatment at last. The COD, BOD, LAS and oil of reuse water was 33.4 mg/L, 4.8 mg/L, 0.06 mg/L and 0.95 mg/L, respectively.  相似文献   

14.
水解/MBR工艺处理低浓度煤化工废水的研究   总被引:1,自引:0,他引:1  
应用水解/MBR工艺对低浓度煤化工废水的处理进行了研究,实验结果表明,在合适的条件下膜出水水质:COD为70.23~96.65 mg/L,浊度为0.10~0.32NTU,色度为23~38度,氨氮为1.3~4.8 mg/L,满足国家二级排放标准.通过扫描电镜清晰的观察到:膜外表面的污泥层及宽度不等的裂缝和泥孔,膜内表面没有受到污染.推测膜外表面呈凝胶状的污染物质是胞外聚合物.  相似文献   

15.
A pilot scale experiment was conducted to evaluate the performance of a membrane bioreactor filled with high concentration powdered activated carbon. This hybrid system has great potential to substitute for existing GAC or O3/BAC processes in the drinking water treatment train. The system was installed at a water treatment plant located downstream of the Nakdong river basin, Korea. Effluent of rapid sand filter was used as influent of the system which consists of PAC bio-reactor, submerged MF membrane module and air supply facility. PAC concentration of 20 g/L was maintained at the beginning of the experiment and it was increased to 40 g/L. The PAC has not been changed during the operational periods. The membrane was a hollow fiber type with pore sizes of 0.1 and 0.4 microm. It was apparent that the high PAC concentration could prevent membrane fouling. 40 g/L PAC was more effective to reduce the filtration resistance than 20 g/L. At the flux of 0.36 m/d, TMP was maintained less than 40 kPa for about 3 months by intermittent suction type operation (12 min suction/3 min idling). Adsorption was the dominant role to remove DOC at the initial operational period. However the biological effect was gradually increased after around 3 months operation. Constant DOC removal could be maintained at about 40% without any trouble and then a tremendous reduction of DBPs (HAA5 and THM) higher than 85% was achieved. Full nitrification was observed at the controlled influent ammonia nitrogen concentration of 3 and 7 mg/L. pH was an important parameter to keep stable ammonia oxidation. From almost two years of operation, it is clear that the PAC membrane bioreactor is highly applicable for advanced water treatment under the recent situation of more stringent DBPs regulation in Korea.  相似文献   

16.
Two-stage SBR for treatment of oil refinery wastewater.   总被引:2,自引:0,他引:2  
A two-stage sequencing batch reactor (SBR) system was used for treatment of oily wastewater with COD and oil and grease (O&G) concentrations ranging from 1,722-7,826 mg/L and 5,365-13,350 mg/L, respectively. A suitable start-up protocol was developed using gradual increase in oily wastewater composition with methanol as the co-substrate. This strategy enabled a short acclimation period of 12 days for the sludge in the two-stage SBR to adapt to the oily wastewater. After acclimation, the 1st stage and 2nd stage SBRs were able to achieve COD removals of 47.0+/-2.4% and 95.3+/-0.5%, respectively. The 1st stage SBR was able to achieve 99.8+/-0.1% of O&G removal and effluent O&G from the 1st stage SBR was only 6+/-2 mg/L. The 2nd stage SBR was used to further remove COD in the effluent from the 1st stage SBR. The final effluent from the 2nd stage SBR had a COD concentration of 97+/-16 mg/L with no detectable O&G content. Thus, a two-stage SBR system was shown to be feasible for treating high strength oily wastewater to meet the local discharge standards.  相似文献   

17.
分散式生活污水处理工艺:DASB+W-SFCW联合工艺   总被引:4,自引:0,他引:4  
提出了“DASB+W-SFCW”联合工艺,并运用该工艺对分散式生活污水进行了处理试验研究。DASB单元采用短时厌氧技术,去除颗粒有机物和部分溶解有机物,防止W-SFCW堵塞,保证W-SFCW单元脱氮所需的碳源。W-SFCW床优化了传统潜流人工湿地的水流流态,使污水在W-SFCW床内呈波式流动,充分地发挥了湿地系统降解污染物的能力。试验结果表明:“DASB+W-SFCW”联合工艺对生活污水具有较强的处理能力,当进水中COD,NH3-N,TP的平均质量浓度分别为268 mg/L,31.5 mg/L,5.5 mg/L时,其平均去除率分别达到80.7%,52.1%,89.7%,出水水质优于传统的二级生物处理工艺。  相似文献   

18.
The performance of an ultra-compact biofilm reactor (UCBR) treating domestic wastewater (DWW) collected from a local water reclamation plant; and gradually shifting to a mono-type carbon source synthetic wastewater (SWW) combined with DDW (CWW) and finally SWW; was investigated in this study. The total COD concentrations of influent DWW and CWW/SWW were 413.6 ± 80.8 mg/L and 454.9 ± 51.3 mg/L, respectively. The UCBR was able to achieve average total COD removal efficiencies of 70 ± 10% and 80 ± 4% for DWW and SWW respectively. The total COD concentrations of the effluent of DWW and CWW/SWW were 122.5 ± 44.4 mg/L and 89.7 ± 10.3 mg/L, respectively. These observations suggested that heterotrophs in the UCBR system were able to better assimilate and remove carbon of mono-type SWW compared to diverse carbon sources such as DWW; although the influent soluble COD concentrations of the SWW were higher than those of the DWW. However, the effluent NH(4)(+)-N concentrations for both types of wastewater were rather similar, <3.0 mg/L; although the influent NH(4)(+)-N concentrations of the DWW were 1.5 times those of the SWW.  相似文献   

19.
针对分散建筑的特点,厌氧-生物托盘系统对生活污水进行了处理试验,分析研究了处理系统污染物的去除效果,COD去除率为90%以上,SS为85%以上,NH3-N为80%以上,TP为80%以上,出水水质各项指标达到中水回用的要求。  相似文献   

20.
混凝沉淀—IC工艺预处理高浓度OE生产废水   总被引:1,自引:0,他引:1  
脂肪酸聚氧乙烯酯(OE)生产过程中产生高浓度有机废水,用混凝沉淀—IC反应器预处理高浓度OE生产废水,当进水CODCr为6 000~9 000 mg/L、SS为800~1 500 mg/L时,出水平均CODCr、SS分别为780 mg/L、200 mg/L,CODCr、SS的平均去除率达到90%和85%,出水水质达到厂方的预处理要求,为后续主体工艺处理提供保障。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号