首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 16 毫秒
1.
A new sensitive voltammetric sensor for determination of sulfadiazine is described. The developed sensor is based on carbon paste electrode modified with sulfadiazine imprinted polymer (MIP) as a recognition element. For comparison, a non-imprinted polymer (NIP) modified carbon paste electrode was prepared. Cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods were performed to study the binding event and electrochemical behavior of sulfadiazine at the modified carbon paste electrodes. The determination of sulfadiazine after its extraction onto the electrode surface was carried out by DPV at 0.92 V vs. Ag/AgCl owing to oxidation of sulfadiazine. Under the optimized operational conditions, the peak current obtained at the MIP modified carbon paste electrode was proportional to the sulfadiazine concentration within the range of 2.0 × 10? 7–1.0 × 10? 4 mol L? 1 with a detection limit and sensitivity of 1.4 × 10? 7 mol L? 1 and 4.2 × 105 μA L mol? 1, respectively. The reproducibility of the developed sensor in terms of relative standard deviation was 2.6%. The sensor was successfully applied for determination of sulfadiazine in spiked cow milk and human serum samples with recovery values in the range of 96.7–100.9%.  相似文献   

2.
The preparation and electrochemical characterization of a carbon paste electrode modified with the N,N-ethylene-bis(salicyllideneiminato)oxovanadium (IV) complex ([VO(salen)]) as well as its application for ranitidine determination are described. The electrochemical behavior of the modified electrode for the electroreduction of ranitidine was investigated using cyclic voltammetry, and analytical curves were obtained for ranitidine using linear sweep voltammetry (LSV) under optimized conditions. The best voltammetric response was obtained for an electrode composition of 20% (m/m) [VO(salen)] in the paste, 0.10 mol L? 1 of KCl solution (pH 5.5 adjusted with HCl) as supporting electrolyte and scan rate of 25 mV s? 1. A sensitive linear voltammetric response for ranitidine was obtained in the concentration range from 9.9 × 10? 5 to 1.0 × 10? 3 mol L? 1, with a detection limit of 6.6 × 10? 5 mol L? 1 using linear sweep voltammetry. These results demonstrated the viability of this modified electrode as a sensor for determination, quality control and routine analysis of ranitidine in pharmaceutical formulations.  相似文献   

3.
A novel Lu(III) PVC membrane sensor has been constructed based on a new synthesized symmetric S–N Schiff's base, namely N-[(Z)-1-(2-thienyl)methylidene]-N-[4-(4-{[(Z)-1-(2-thienyl) methylidene]amino}benzyl)phenyl] amine (TBPA). The electrode showed a Nernstian slope of 19.8 ± 0.5 mV per decade across a wide concentration range of 1.0 × 10? 6 to 1.0 × 10? 2 mol L? 1 with a detection limit of 7.2 × 10? 7 mol L? 1. The proposed sensor showed high selectivity toward Lu(III) ion in comparison with common alkaline, alkaline earth, transition, and heavy metals specially lanthanide ions, and could be used over a pH range of 2.7–10.6. It can be used for at least 2 months without any considerable divergency in potentials and it has a relatively fast response time of < 10 s. The sensor was effectively used as an indicator electrode in the potentiometric titration of Lu(III) ions with EDTA. The constructed sensor accuracy was investigated by the monitoring of Lu(III) ion in mixtures of two and three different ions.  相似文献   

4.
Solution study showed N,N′-bis(5-nitrosalicylidene)-2-aminobenzylamin (L) trends toward Tb3+ ion. Then, it was used as a suitable ionophore in construction of terbium ion selective electrode. The electrode with composition of 30% PVC, 65% solvent mediator (NB), 3% ionophore (L) and 2% anionic additive (NaTPB) shows the best potentiometric response characteristics. It displays a Nernstian behavior (20.1 mV decade?1) over the concentration range 1.0 × 10? 6 to 1.0 × 10? 2 mol L?1. The detection limit of the electrode is 6.3 × 10? 7 mol L?1. It has a very short response time (~ 10 s) and a useful working pH range of 2.6–9.4 for at least 2 months. The proposed membrane sensor shows excellent discriminating ability towards Tb3+ ions with regard to several alkali, alkaline earth, transition and heavy metal ions. To investigate the analytical applicability of the sensor, it was successfully applied to the determination of terbium in certified reference material.  相似文献   

5.
A new ion-selective electrode for Sm3 + ion is described based on the incorporation of N,N′,N″-tris(4-pyridyl)trimesic amide (TPTA) in a poly(vinylchloride) (PVC) matrix. The membrane sensor comprises nitrobenzene (NB) as a plasticizer, and oleic acid (OA) as an anionic additive. The sensor with the optimized composition shows a Nernstian potential response of 19.8 ± 0.5 mV decade? 1 over a wide concentration range of 1.0 × 10? 2 and 1 × 10? 6 mol L? 1, with a lower detection limit of 4.7 × 10? 7 mol L? 1 and satisfactor applicable pH range of 3.6–9.2. Having a short response time of less than 10 s and a very good selectivity towards the Sm3 + over a wide variety of interfering cations (e.g. alkali, alkaline earth, transition and heavy metal ions) the sensor seemed to be a promising analytical tool for determination of the Sm3 +. Hence, it was used as an indicator electrode in the potentiometric titration of samarium ion with EDTA. It was also applied to the direct samarium recovery in binary mixtures.  相似文献   

6.
A new Pr3+ poly vinyl chloride PVC membrane sensor based on a membrane containing 3% N,N′-bis(4-hydroxysalicylidene)-1-3-phenylenediamine (HSPDA) as an ionophore, 2% sodium tetraphenyl borate (NaTPB) as an anionic additive, 65% benzyl acetate (BA) as solvent mediator and 30% poly(vinyl chloride) was prepared. This sensor responds to praseodymium ion in a wide linear dynamic range of 1.0 × 10?6 to 1.0 × 10?2 mol L?1 with Nernstian slope of 19.8 ± 0.4 mV per decade and a detection limit of 5.7 × 10?7 mol L? 1 in pH range of 3.1 to 9.8. It has a fast response time of ~5 s in the whole concentration range, and can be used for at least 2 months without any considerable divergences in the potentials. The proposed sensor displays an excellent selectivity for Pr3+ ions with respect to a large number of alkali, alkaline earth, transition and heavy metal ions. The developed sensor was successfully applied as an indicator electrode in Pr3+ ion potentiometric titration with EDTA, and in direct determination of fluoride ion in two mouth wash samples.  相似文献   

7.
Zeolite A was synthesized from waste porcelain and modified by hexadecylpyridinium surfactant to change the cation exchanger property of the raw zeolite to anion exchanger property in the obtained surfactant modified zeolite (SMZ). The SMZ was used as an active ingredient component of a membrane selective sulfite electrode. The electrode was fully characterized in terms of composition, response time, thermal stability and usable pH range. The sensor showed suitable response to sulfite in the concentration range of 8.0 × 10? 7 to 1.0 × 10? 1 mol L? 1, with a detection limit of 5.0 × 10? 7 mol L? 1 and a slope of ? 29.5 ± 0.8 mV per decade of sulfite concentration.  相似文献   

8.
In this research, we report a new Ho3 +-PVC membrane electrode based on N-(4,5-dimethyl-2-(picolinamido)phenyl)picolinamide (H2Me2bpb) as a suitable ion carrier. Poly vinylchloride (PVC)-based membrane composed of H2Me2bpb with oleic acid (OA) as anionic additives, and o-nitrophenyloctyl ether (NPOE) as plasticized solvent mediator. The sensor exhibits a Nernstian slope of 20.1 ± 0.2 mV decade? 1 over the concentration range of 1.0 × 10? 6 to 1.0 × 1? 2 mol L? 1, and a detection limit of 5.0 × 10? 7 mol L? 1 of Ho3 + ions. The potentiometric response of the sensor is independent of the solution pH in the range of 3.5–9.4. It has a very short response time, in the whole concentration range (< 10 s), and can be used for at least eight weeks. The proposed electrode shows a good selectivity towards Ho3 + ions over a wide variety of cations, including alkali, alkaline earth, transition and heavy metal ions. To assess its analytical applicability the proposed Ho3 + sensor was successfully applied as an indicator electrode in the titration of Ho3 + ion solutions in certified reference materials, alloy samples and for the determination of the fluoride ion in two mouthwash preparations.  相似文献   

9.
Folic acid (FA) is a water soluble vitamin that exists in many natural species. The lack of FA causes some deficiencies in human body, so finding a simple and sensitive method for determining the FA is important. A new chemically modified electrode was fabricated for determination of FA in human blood plasma using gold nanoparticles (AuNPs) and carbon paste electrode (CPE). Gold nanoparticles–modified carbon paste electrode (AuNPs/CPE) was characterized by transmission electron microscopy (TEM) and scanning electron microscopy (SEM). The experimental parameters such as pH, scan rate (ν) and amount of modifier were studied by cyclic voltammetry and the optimized values were chosen. The electrochemical parameters such as diffusion coefficient of FA (DFA), electrode surface area (A) and electron transfer coefficient (α) were calculated. Square wave voltammetry as an accurate technique was used for quantitative calculations. A good linear relation was observed between anodic peak current (ipa) and FA concentration (CFA) in the range of 6 × 10? 8 to 8 × 10? 5 mol L? 1, and the detection limit (LOD) achieved 2.7 × 10? 8 mol L? 1, that is comparable with recently studies. This paper demonstrated a novel, simple, selective and rapid sensor for determining the FA in the biological samples.  相似文献   

10.
Gold nanotube arrays of rough and porous wall has been synthesized by direct electrodeposition with cyclic voltammetry utilizing anodic aluminum oxide template (AAO) and polycarbonate membrane (PC) during short time (only 3 min and 2 min, respectively). The mechanism of the direct electrodeposition of gold nanotube arrays by cyclic voltammetry (CV) has been discussed. The morphological characterizations of the gold nanotube arrays have been investigated by scanning electron microscopy (SEM). A simultaneous determination of ascorbic acid (AA) and uric acid (UA) by differential pulse voltammetry (DPV) was constructed by attaching gold nanotube arrays (using AAO) onto the surface of a glassy carbon electrode (GCE). The electrochemical behavior of AA and UA at this modified electrode has been studied by CV and differential pulse voltammetry (DPV). The sensor offers an excellent response for AA and UA and the linear response range for AA and UA were 1.02 × 10? 7–5.23 × 10? 4 mol L? 1 and 1.43 × 10? 7–4.64 × 10? 4 mol L? 1, the detection limits were 1.12 × 10? 8 mol L? 1 and 2.24 × 10? 8 mol L? 1, respectively. This sensor shows good regeneration, stability and selectivity and has been used for the determination of AA and UA in real human urine and serum samples with satisfied results.  相似文献   

11.
A novel Dy(III) ion-selective PVC membrane sensor was made using a new synthesized organic compound, 3,4-diamino-N′-((pyridin-2-yl)methylene)benzohydrazide (L) as an excellent sensing element. The electrode showed a Nernstian slope of 19.8 ± 0.6 mV per decade in a wide concentration range of 1.0 × 10? 6–1.0 × 10? 2 mol L? 1, a detection limit of 5.5 × 10? 7 mol L? 1, a short conditioning time, a fast response time (< 10 s), and high selectivity towards Dy(III) ion in contrast to other cations. The proposed sensor was successfully used as an indicator electrode in the potentiometric titration of Dy(III) ions with EDTA. The membrane sensor was also applied to the F ion indirect determination of some mouth washing solutions and to the Dy3 + determination in binary mixtures.  相似文献   

12.
A selective method for the determination of thorium (IV) using an optical sensor is described. The sensing membrane is prepared by immobilization of thorin–methyltrioctylammonium ion pair on triacetylcellulose polymer. The sensor produced a linear response for thorium (IV) concentration in the range of 6.46 × 10?6 to 9.91 × 10?5 mol L?1 with detection limit of 1.85 × 10?6 mol L?1. The regeneration of optode was accomplished completely at a short time (less than 20 s) with 0.1 mol L?1 of oxalate ion solution. The relative standard deviation for ten replicate measurements of 2.15 × 10?5 and 8.62 × 10?5 mol L?1 of thorium was 2.71 and 1.65%, respectively. The optode membrane exhibits good selectivity for thorium (IV) over several other ionic species and are comparable to those obtained in case of spectrophotometric determination of thorium using thorin in solution. A good agreement with the ICP-MS and spiked method was achieved when the proposed optode was applied to the determination of thorium (IV) in dust and water samples.  相似文献   

13.
A new podand of 1,1′-thiobis(naphthalene-2,1-diyl)bis(2-aminobenzoate) (TNBA) was synthesized and used as a suitable carrier for construction of Pb2+ modified carbon paste electrode (CPE). The effects of various plasticizers; 2-nitrophenyloctylether (o-NPOE), dioctyl pththalate (DOP), dibutyl phthalate (DBP) and paraffin oil were studied. The best performance was obtained with a matrix composition of CPE with a DOP/graphite powder/TNBA weight percent ratio of 35/60.5/4.5. The sensor exhibits significantly enhanced selectivity toward Pb2+ ion over the concentration range 8.0 × 10? 8 to 1.0 × 10? 2 mol L? 1 with a lower detection limit of 5.0 × 10? 8 mol L? 1 and a Nernstian slope of 29.0 ± 0.2 mV decade? 1 of lead activity. It has a fast response time of 8 s with a working pH range from 3.5 to 7. The interaction between TNBA and Pb2+ was studied spectrophotometrically and it exhibits that the stoichiometry of the complex is 1:1 in acetonitrile solution. Finally, the electrode was satisfactorily used as an indicator electrode in complexometric titration of Pb2+ with EDTA and in direct determination of lead in various water samples.  相似文献   

14.
The construction, performance characteristics, and application of a novel iron(III) membrane sensor based on a new bis-benzilthiocarbohydrazide (BBTC) are reported in this paper. The sensor is prepared by incorporating of BBTC, nitrobenzene (NB), and sodium tetraphenyl borate (NaTPB) into a plasticized poly(vinyl chloride) membrane. The electrode reveals a Nernstian behavior over a wide iron ion concentration range (1.0 × 10? 2–1.0 × 10? 7 mol L? 1), and relatively low detection limit (8.6 × 10? 8 mol L? 1). The potentiometric response is independent on the pH of the solution in the range of 1.6–4.3. The electrode shows a very short response time (< 10 s). The proposed electrode can be used for at least nine weeks without any considerable divergence in potentials. It exhibits very good selectivity relative to a wide variety of alkali, alkaline earth, transition and heavy metal ions. In fact, the selectivity of the proposed sensor shows great improvements compared to the previously reported electrodes for the iron ion. Also, the sensors accuracy was investigated in two ways: (i) with the potentiometric titration of a Fe(III) solution with EDTA and (ii) with the Fe(III) monitoring in river and wastewater samples.  相似文献   

15.
The carbon paste electrode modified by kaolin (KCPE) has been utilized for the determination of pesticides with high sensitivity based on their redox behavior. The experiment is performed on the use of cyclic and square wave voltammetry. Experimental conditions were optimized by varying the accumulation time, kaolin loading and measuring solution pH. Square wave voltammetric response showed a linear calibration curve in the range from 3.9 × 10? 9 to 9 × 10? 5 mol L? 1 with a detection limit of 2 × 10? 10 mol L? 1 at kaolin-modified carbon paste electrode. As a result, it was found that there was feasibility in the use of kaolin to improve the carbon paste electrode properties.  相似文献   

16.
In this study, a new thulium(III) membrane sensor was constructed. The proposed membrane sensor was fabricated based on a membrane containing 2% sodium tetraphenyl borate (NaTPB) as an anionic additive, 65% benzyl acetate (BA) as solvent mediator, 3% 1-(2-thiazolylazo)-2-naphthol (TN) as ionophore, and 30% poly(vinyl chloride) (PVC). The proposed Tm3+ electrode exhibits a Nernstian response of 19.5 ± 0.2 mV per decade of thulium concentration, and has a lower detection limit of 8.7 × 10? 7 mol L? 1. The linear range of the sensors was 1.0 × 10? 6 to 1.0 × 10? 2 mol L? 1. It works well in the pH range of 3.2–9.5. Moreover, the recommended selective sensor revealed a comparatively satisfactory selectivity regarding most of the alkali, alkaline earth, some transition and heavy metal ions. The membrane sensor was applied to the determination of fluoride ions in mouth wash samples.  相似文献   

17.
A newly synthesized Schiff base 3-aminoacetophenonesemicarbazone (AAS) has been used for the preparation of Ni2 + selective PVC membrane electrode. The proposed electrode exhibits a Nernstian response over the nickel concentration range of 1.0 × 10? 7 to 1.0 × 10? 2 mol L? 1 with a slope of 30.0 ± 0.3 mV/decade of concentration. The limit of detection as determined from the intersection linear segment of the calibration plot is 5.1 × 10? 8 mol L? 1. The electrode shows good selectivity towards nickel with respect to several alkali, alkaline earth, transition and heavy metal ions. The response time of the electrode is very fast (≥ 10 s) and can be used for 17 weeks in the pH range of 2.0–9.8. The electrode can also be used in partially non-aqueous media having up to 20% (v/v) methanol, ethanol or acetone content with no significant change in the value of slope or working concentration range. To investigate the analytical applicability of the electrode, it was successfully applied as an indicator electrode in Ni2 + ion potentiometric titration with EDTA, and in direct determination of nickel(II) in real samples.  相似文献   

18.
The biological properties of the lutetium as well as other lanthanide ions, primarily based on their similarity to calcium, have been the bases for research into potential therapeutic applications of lanthanide series since the early part of the twentieth century. In this research, a Lu(III) potentiometric membrane sensor based on N,N′-bis(2-pyridinecarboxamide)-1,2-ethane (PCAE) is described. The sensor exhibits a Nernstian response over a concentration range of 1.0 × 10? 6 mol L? 1–1.0 × 10? 1 mol L? 1, with a detection limit of 6.0 × 10? 7 mol L? 1. The best performance was achieved with a membrane composition, consisting of 30% PVC, 63% o-nitrophenyl octyl ether (NPOE), 5% PCAE and 2% sodium tetraphenylborate (NaTPB). It was found that at the pH range of 4.0–9.0, the potential response of the sensor was not affected by the pH. Furthermore, the electrode presents satisfactory reproducibility, very fast response time (5 s) and relatively good discriminating ability for Lu(III) ions with respect to many common cations and other lanthanide ions. The sensor has been applied to the determination of Lu(III) in human serum and in some soil samples where domestic devices were stored.  相似文献   

19.
A thulium(III) membrane sensor was made using 2% sodium tetraphenyl borate (NaTPB), 65% dibutylphthalate (DBP), 30% poly(vinyl chloride) (PVC) and 3% 1-ethyl-3-(2,5-dihydro-4-(3,5-dimethyl-1H-pyrazol-4-yl)-5-oxo-1H-pyrazol-3-yl)thiourea (ET) as an ionophore. Conductometric study shows selectivity of the Et toward Tm3+ ions. Nernstian response of 19.6 ± 0.4 mV per decade of thulium concentration was observed, and the electrode worked well in concentration range of 1.0 × 10? 6 to 1.0 × 10? 2 mol L? 1 with a lower detection limit (LDL) of 7.2 × 10? 7 mol L? 1, in a pH range of 4.3–10.4. The selectivity of the sensor over alkaline, alkaline earth, transition and heavy metal ions was also found to be in a satisfactory range. To check the analytical applicability of the proposed Tm3+ sensor, it was successfully used as an indicator electrode in analysis of thulium in certified reference materials.  相似文献   

20.
Poly(vinyl chloride)-based membranes of two ligands 2,4-bis(2-acetoxybenzylamino)-6-phenyl-1,3,5-triazine (L1) and N2,N4-di(cyanoethyl)-2,4-bis(2-acetoxybenzylamino)-6-phenyl-1,3,5-triazine (L2) were fabricated and explored as Mn2 + ion selective electrodes. The performance of the polymeric membranes electrodes of ionophores with different plasticizers (dibutylphthalate, benzoic acid, o-nitrophenyloctyl ether, 1-chloronapthalene and tri-n-butylphosphate) and anion excluders (sodium tetraphenylborate and potassium tetrakis p-(chloro phenyl)borate) was looked in to and the better results were obtained with the membrane having composition L2: NaTPB: DBP: PVC as 6: 3: 56: 35 (w/w; mg). The coated graphite electrode (CGE) with same composition was also fabricated and investigated as Mn2 + selective electrode. It was found that CGE showed better response characteristics than PME. The potentiometric response of CGE was independent of pH in the range 3.0–9.0 exhibiting the Nernstian slope 29.5 ± 0.3 mV decade? 1 of activity and working concentration range 4.1 × 10? 7–1.0 × 10? 1 mol L? 1 with a limit of detection 6.7 × 10? 8 mol L? 1. The electrode showed a fast response time of 12 s with a shelf life of 105 days. The proposed CGE could be successfully used for the determination of Mn2 + ions in different water, soil, vegetables and medicinal plants also used as an indicator electrode in potentiometric titration with EDTA.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号