1.
Membrane deformation of living glial cells using atomic force microscopy   总被引:3,自引:0,他引:3  
Using atomic force microscopy (AFM) it has been possible to detect actin filaments that are beneath the cell membrane of living cells despite the fact that the AFM tip is applied to the surface of the cell. To determine whether the AFM tip actually penetrates or deforms the cell membrane we determined whether an intracellularly trapped fluorescent indicator was lost from cells during AFM. Using epi-fluorescence illumination to monitor the presence of fluo-3 in the cell, we found that AFM did not cause dye leakage from the cell. Further, force–distance curves indicated that standard tips did not penetrate the membrane while sharper SupertipsTM did. In addition, the physiology of cells was found to be unaffected by AFM with standard tips since volume regulatory signal transduction mechanisms were intact in such studies. Thus, traditional AFM tips deform the cell membrane in order to reveal the presence of subcellular structures.  相似文献   

2.
A comparative study of atomic force microscopy (AFM) and scanning electron microscopy (SEM) imaging of the healthy human liver parenchyma was carried out to determine the similarities and the differences. In this study, we compared the fine hepatic structures as observed by SEM and AFM. Although AFM revealed such typical hepatic structures as bile canaliculi and hepatocytes, it also showed the location of the nucleus and chromatin granules in rough relief structure, which was not visible by SEM. By contrast, SEM visualized other structures, such as microvilli, the central vein, and collagenous fibers, none of which was visualized by AFM. For better orientation and confirmation of most of the structures imaged by SEM and AFM, Congo Red-stained specimens were also examined. Amyloid deposits in the Disse's spaces were shown especially clearly in these images. The differences between the SEM and AFM images reflected the characteristics of the detection systems and methods used for sample preparation. Our results reveal that more detailed information on hepatic morphology is obtained by exploiting the advantages of both SEM and AFM.  相似文献   

3.
Integrated information on ultrastructural surface texture and chemistry increasingly plays a role in the biomedical sciences. Light microscopy provides access to biochemical data by the application of dyes. Ultrastructural representation of the surface structure of tissues, cells, or macromolecules can be obtained by scanning electron microscopy (SEM). However, SEM often requires gold or coal coating of biological samples, which makes a combined examination by light microscopy and SEM difficult. Conventional histochemical staining methods are not easily applicable to biological material subsequent to such treatment. Atomic force microscopy (AFM) gives access to surface textures down to ultrastructural dimensions without previous coating of the sample. A combination of AFM with conventional histochemical staining protocols for light microscopy on a single slide is therefore presented. Unstained cores were examined using AFM (tapping mode) and subsequently stained histochemically. The images obtained by AFM were compared with the results of histochemistry. AFM technology did not interfere with any of the histochemical staining protocols. Ultrastructurally analyzed regions could be identified in light microscopy and histochemical properties of ultrastructurally determined regions could be seen. AFM-generated ultrastructural information with subsequent staining gives way to novel findings in the biomedical sciences. Microsc. Res. Tech., 2009. © 2009 Wiley-Liss, Inc.  相似文献   

4.
McMullen RL  Kelty SP 《Scanning》2001,23(5):337-345
Atomic force microscopy (AFM) and lateral force microscopy (LFM) were used to investigate the morphologic and surface changes associated with various surface modifications to human hair. These included extraction with a series of solvents, bleaching, and treatment with a cationic copolymer. The study assessed the ability of these techniques to distinguish the changes in surface properties, including morphology and friction coefficient, as manifested in changes brought about by the indicated surface modifications. While topographic morphology can easily be investigated with contact AFM. LFM offers an additional tool for probing the surface distribution of oils and waxes. The removal of surface lipids from the fiber surface was accomplished using soxhlet extraction with t-butanol and n-hexane, while the free internal lipids (within the fiber structure) were removed by extraction with a mixture of chloroform and methanol (70:30, v/v). In addition, the surface of hair was modified with the cationic polymer, co(vinyl pyrrolidone-methacrylamidopropyl trimethylammonium chloride [PVP/MAPTAC]), and its distribution on the surface was monitored. Ambient AFM and LFM studies of surface modified and native fibers clearly indicate that when investigated as a function of tip loading force, the different modifications result in changes of the friction coefficient, which increase in this order: native, bleached, solvent extracted, and polymer-treated hair. Friction images show surface variations that are interpreted as areas of varying lipid film coverage. In addition, topographic images of the fibers show the presence of small pores, which become increasingly prevalent upon solvent extraction.  相似文献   

5.
Stiffness-load curves obtained in quantitative atomic force acoustic microscopy (AFAM) measurements depend on both the elastic properties of the sample and the geometry of the atomic force microscope (AFM) tip. The geometry of silicon AFM tips changes when used in contact mode, affecting measurement accuracy. To study the influence of tip geometry, we subjected ten AFM tips to the same series of AFAM measurements. Changes in tip shape were observed in the scanning electron microscope (SEM) between individual AFAM tests. Because all of the AFAM measurements were performed on the same sample, variations in AFAM stiffness-load curves were attributed to differences in tip geometry. Contact-mechanics models that assumed simple tip geometries were used to analyze the AFAM data, but the calculated values for tip dimensions did not agree with those provided by SEM images. Therefore, we used a power-law approach that allows for a nonspherical tip geometry. We found that after several AFAM measurements, the geometry of the tips at the very end is intermediate between those of a flat punch and a hemisphere. These results indicate that the nanoscale tip-sample contact cannot easily be described in terms of simple, ideal geometries.  相似文献   

6.
W. K. Chim 《Scanning》1995,17(5):306-311
Investigations on the use of the scanning probe microscope (SPM) in the atomic force microscopy (AFM) mode for topography imaging and the magnetic force microscopy (MFM) mode for magnetic imaging are presented for a thin-film recording head. Results showed that the SPM is suitable for imaging the surface profile of the recording head, determining the width of the pole gap region, and mapping the magnetic field patterns of the recording head excited under current bias conditions of different polarity. For the cobalt sputter-coated tips used in MFM imaging, it was found that the magnetic field patterns obtained under different polarities of the current bias to the recording head were similar. This can be explained by the nature of the thin-film MFM tip, in which the direction of the tip magnetic moment can follow the stray magnetic field of the sample as the current bias to the recording head reverses in direction.  相似文献   

7.
Various labial and lingual orthodontic appliances with aesthetic materials have been developed due to an increased demand in aesthetic orthodontic treatment. However, there are few reports regarding the morphology of lingual orthodontic appliances. Therefore, this study evaluates the roughness of slot surfaces of various orthodontic lingual brackets using field emission scanning electron microscopy (FE‐SEM) and atomic force microscopy (AFM). Three types of stainless steel lingual brackets (Stealth®, 7th Generation®, and Clippy L®) and one gold lingual bracket (Incognito?) with a slot size of 0.018 inches × 0.025 inches (0.457 × 0.635 mm2) were selected as representative lingual materials. Both FE‐SEM and AFM examinations showed that the Stealth® and Clippy L® brackets had the lowest surface roughness, while the 7th Generation® bracket had the highest surface roughness. There was a significant difference in surface morphology between the types of lingual brackets, even when composed of the same material. The surface roughness of the bracket slot was dependent on the manufacturing process or surface polishing process rather than the fundamental properties of the bracket materials. There was no significant difference in the mean surface roughness of the slot floor between gold and stainless steel lingual brackets. These findings suggest that, although the gold lingual bracket is very expensive, it has great potential for use in patients with nickel allergy.  相似文献   

8.
The adsorption of his-tag green fluorescent protein (GFPH(6)) onto the mica surfaces has been studied by atomic force microscopy (AFM) and laser confocal fluorescence microscopy. By controlling the adsorption conditions, separated single GFPH(6) and GFPH(6) monolayer can be adsorbed and formed on mica surfaces. In present experiments, based on the AFM measurement, we found that the adsorbed GFPH(6) was bound on the mica surface with its beta-sheets. The formed GFPH(6) monolayer on mica surfaces was flat, uniform, and stable. Some applications of the formed monolayer have been demonstrated. The formed monolayer can be used as a substrate for DNA imaging and AFM mechanical lithography.  相似文献   

9.
The protein surface layer of the bacterium Deinococcus radiodurans (HPI layer) was examined with an atomic force microscope (AFM). The measurements on the air-dried, but still hydrated layer were performed in the attractive imaging mode in which the forces between tip and sample are much smaller than in AFM in the repulsive mode or in scanning tunnelling microscopy (STM). The results are compared with STM and transmission electron microscopy (TEM) data.  相似文献   

10.
Ball-shaped atomic force microscope (AFM) tips (ball tips) are useful in AFM metrology, particularly in critical dimension AFM metrology and in micro-tribology. However, a systematic fabrication method for nano-scale ball tips has not been reported. We report that nano-scale ball tips can be fabricated by ion-beam-induced deposition (IBID) of Pt at the free end of multiwall carbon nanotubes that are attached to AFM tips. Scanning electron microscopy and transmission electron microscopy analyses were done on the Pt ball tips produced by IBID in this manner, using ranges of Ga ion beam conditions. The Pt ball tips produced consisted of aggregated Pt nano-particles and were found to be strong enough for AFM imaging.  相似文献   

11.
The technique demonstrated here provides features of both scanning tunnelling microscopy (STM) and atomic force microscopy (AFM). The metallic probe acts to record current variations and sense forces from the same sample area simultaneously. Thus, separate images may be recorded, in registry. The collected data allows real space correlations between some electrical properties and the geometric structure of a sample surface. The same tip is used since the geometry and condition of the tip can effect the data recordings. Platinum alloys, tungsten and graphite tips have been employed successfully. An AFM lever can respond to surface contact forces, within the elastic limits of the sample, while electric current is sensed by the tip of the lever. The usefulness of this experimental procedure is tested here by an application to semiconducting samples of Ag-doped CdTe in air and in paraffin oil media.  相似文献   

12.
This paper analyses the three‐dimensional (3‐D) surface morphology of optic surface of unworn contact lenses (CLs) using atomic force microscopy (AFM) and wavelet transform. Refractive powers of all lens samples were 2.50 diopters. Topographic images were acquired in contact mode in air‐conditioned medium (35% RH, 23°C). Topographic measurements were taken over a 5 µm × 5 µm area with 512 pixel resolution. Resonance frequency of the tip was 65 kHz. The 3‐D surface morphology of CL unworn samples revealed (3‐D) micro‐textured surfaces that can be analyzed using (AFM) and wavelet transform. AFM and wavelet transform are accurate and sensitive tools that may assist CL manufacturers in developing CLs with optimal surface characteristics. Microsc. Res. Tech. 78:1026–1031, 2015. © 2015 Wiley Periodicals, Inc.  相似文献   

13.
Rat liver sinusoidal endothelial cells (LEC) contain fenestrae, which are clustered in sieve plates. Fenestrae control the exchange of fluids, solutes and particles between the sinusoidal blood and the space of Disse, which at its back side is flanked by the microvillous surface of the parenchymal cells. The surface of LEC can optimally be imaged by scanning electron microscopy (SEM), and SEM images can be used to study dynamic changes in fenestrae by comparing fixed specimens subjected to different experimental conditions. Unfortunately, the SEM allows only investigation of fixed, dried and coated specimens. Recently, the use of atomic force microscopy (AFM) was introduced for analysing the cell surface, independent of complicated preparation techniques. We used the AFM for the investigation of cultured LEC surfaces and the study of morphological changes of fenestrae. SEM served as a conventional reference.
AFM images of LEC show structures that correlate well with SEM images. Dried-coated, dried-uncoated and wet-fixed LEC show a central bulging nucleus and flat fenestrated cellular processes. It was also possible to obtain height information which is not available in SEM. After treatment with ethanol or serotonin the diameters of fenestrae increased (+6%) and decreased (−15%), respectively. The same alterations of fenestrae could be distinguished by measuring AFM images of dried-coated, dried-uncoated and wet-fixed LEC. Comparison of dried-coated (SEM) and wet-fixed (AFM) fenestrae indicated a mean shrinkage of 20% in SEM preparations. In conclusion, high-resolution imaging with AFM of the cell surface of cultured LEC can be performed on dried-coated, dried-uncoated and wet-fixed LEC, which was hitherto only possible with fixed, dried and coated preparations in SEM and transmission electron microscopy (TEM).  相似文献   

14.
Atomic force microscopy (AFM) and scanning electron microscopy with energy dispersive spectroscopy (SEM-EDS) have been used for both morphological and elemental mass analysis study of atmospheric particles. As part of the geometrical particle analysis, and in addition to the traditional height profile measurement of individual particles, AFM was used to measure the volume relative to the projection area for each particle separately, providing a particle shape model. The element identification was done by the EDS analysis, and the element mass content was calculated based on laboratory calibration with particles of known composition. The SEM-EDS mass measurements from two samples collected at 150 and 500 m above the surface of the Mediterranean Sea were found to be similar to mass calculations derived from the AFM volume measurements. The AFM results show that the volume of most of the aerosols that were identified as soluble marine sulfate and nitrate aerosol particles can be better estimated using cylindrical shapes than spherical or conical geometry.  相似文献   

15.
This paper describes the investigation of elastical properties and imaging of living cochlear hair bundles of inner (IHC) and outer hair cells (OHC) on the level of individual stereocilia. A custom-made AFM-setup was used, allowing to scan the mechano-sensitive structures of the inner ear under direct control of an upright differential interference contrast (DIC) microscope with a water-immersion objective. Scanning electron microscopy (SEM) images of the identical hair bundles obtained after AFM investigation demonstrated that forces up to 1.5 nanonewton (nN) did not cause obvious damage of the surface morphology of the stereocilia. These are the first images of hair bundles of living sensory cells of the organ of Corti by AFM. They display the tips of individual stereocilia and the typical V-shape of ciliary bundles. Since line scans clearly show that slope and force interaction depend on the elastical properties of stereocilia, quantitative stiffness measurements and stimulation of single transduction channels are suggested.  相似文献   

16.
Cupric oxide (CuO) semiconducting thin films were prepared at various copper sulfate concentrations by dip coating. The copper sulfate concentration was varied to yield films of thicknesses in the range of 445–685 nm by surface profilometer. X‐ray diffraction patterns revealed that the deposited films were polycrystalline in nature with monoclinic structure of (?111) plane. The surface morphology and topography of monoclinic‐phase CuO thin films were examined using scanning electron microscopy (SEM) and atomic force microscopy (AFM), respectively. Surface roughness profile was plotted using WSxM software and the estimated surface roughness was about ~19.4 nm at 30 mM molar concentration. The nanosheets shaped grains were observed by SEM and AFM studies. The stoichiometric compound formation was observed at 30 mM copper sulfate concentration prepared film by EDX. The indirect band gap energy of CuO films was increased from 1.08 to 1.20 eV with the increase of copper sulfate concentrations. Microsc. Res. Tech., 2013. © 2012 Wiley Periodicals, Inc.  相似文献   

17.
A combination of scanning electron microscopy (SEM) and environmental scanning electron microscopy (ESEM) techniques, as well as atomic force microscopy (AFM) methods has been used to study fragments of the Martian meteorite ALH84001. Images of the same areas on the meteorite were obtained prior to and following gold/palladium coating by mapping the surface of the fragment using ESEM coupled with energy-dispersive X-ray analysis. Viewing of the fragments demonstrated the presence of structures, previously described as nanofossils by McKay et al . (Search for past life on Mars — possible relic biogenic activity in martian meteorite ALH84001. Science , 1996, pp. 924–930) of NASA who used SEM imaging of gold-coated meteorite samples. Careful imaging of the fragments revealed that the observed structures were not an artefact introduced by the coating procedure.  相似文献   

18.
Huang JC  Chen CM 《Scanning》2012,34(3):191-199
This study proposes an innovative atomic force microscopy (AFM) based nanoscale electrical discharge machining (AFM-based nanoEDM) system which combines an AFM with a self-produced metallic probe and a high-voltage generator to create an atmospheric environment AFM-based nanoEDM system and a deionized water (DI water) environment AFM-based nanoEDM system. This study combines wire-cut processing and electrochemical tip sharpening techniques on a 40-μm thick stainless steel sheet to produce a high conductive AFM probes, the production can withstand high voltage and large current. The tip radius of these probes is approximately 40 nm. A probe test was executed on the AFM using probes to obtain nanoscales morphology of Si wafer surface. The silicon wafer was as a specimen to carry out AFM-base nanoEDM process in atmospheric and DI water environments by AFM-based nanoEDM system. After experiments, the results show that the atmospheric and DI water environment AFM-based nanoEDM systems operate smoothly. From experimental results, it can be found that the electric discharge depth of the silicon wafer at atmospheric environments is a mere 14.54 nm. In a DI water environment, the depth of electric discharge of the silicon wafer can reach 25.4 nm. This indicates that the EDM ability of DI water environment AFM-based nanoEDM system is higher than that of atmospheric environment AFM-based nanoEDM system. After multiple nanoEDM process, the tips become blunt. After applying electrochemical tip sharpening techniques, the tip radius can return to approximately 40 nm. Therefore, AFM probes produced in this study can be reused.  相似文献   

19.
A novel sample holder that enables atomic force microscopy (AFM) tips to be mounted inside a scanning electron microscopy (SEM) for the purpose of characterizing the AFM tips is described. The holder provides quick and easy handling of tips by using a spring clip to hold them in place. The holder can accommodate two tips simultaneously in two perpendicular orientations, allowing both top and side view imaging of the tips by the SEM.  相似文献   

20.
In order to improve the spatial resolution achieved by magnetic force microscopy (MFM) technique and its derivatives, we employ here advanced MFM tips fabricated by means of focused ion beam (FIB) milling. The magnetic coating applied on these tips is a CoCr film of 10 nm thickness. The MFM measurements on hard disk test samples reveal the achieved high resolution, and the measurement on a garnet film demonstrates the low invasiveness. High-frequency MFM (HF-MFM) is a development of the MFM technique to observe the HF stray fields emerging from magnetic recording writer poles at their operating conditions. By means of HF-MFM, magnetic recording writer poles are characterized in the frequency range 100-1,000 MHz. Up to now, all HF-MFM experiments conducted were using standard MFM cantilevers. From the HF-MFM images obtained using the advanced MFM cantilevers, it is clearly seen that the spatial resolution is considerably improved over the images obtained using standard MFM tips. However, the 10 nm thick magnetic coating of the cantilevers is found to work properly only at frequencies of up to about 500 MHz.  相似文献   