共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
3.
《深冷技术》2008,(5)
法国液化空气集团成立于1902年,是全球领先的工业气体和医疗气体以及相关服务的供应商,业务遍及72个国家,拥有近4万名员工。集团借助不断更新的技术为各方提供创新的解决方案,并生产各种空气产品(氧气、氮气、稀有气体)以及氢气等其他气体。法国液化空气集团为众多日常生活用品的生产也做出了贡献:饮料中的气泡,食品封装的保护气体,医院和家庭理疗所需的氧气,电子工业所需的超纯气体以及燃油脱硫所需的氢气等。法国液化空气集团2007年的销售额为118亿欧元,其中近80%的销售额都是在法国以外实现的。法国液化空气集团在巴黎证券交易市场上市,同时是法国股指CAC40和Eurostoxx50indices的成员企业。在福布斯2007年公布的世界500强中排名第339位。 相似文献
4.
5.
针对某空间任务要求,分析了热试验温度取值.基于1台6 W@90 K星载斯特林制冷机,开展了常压热循环和热真空试验研究,得到了制冷机在不同温区下的制冷性能参数.从6个方面对比分析了两个试验中性能参数的变化,最后得出:环境温度对6 w制冷机性能影响较大,从50 ℃到-20℃温区,制冷温度为90 K时,冷量增大约1.4 W,功耗减小约17 W;在50至-20℃温区内,制冷机未发生结构热变形失效.该6 W型制冷机在合理设计辅助散热(卫星总体热控调节)之后,可满足空间应用时-20℃-40 ℃温区热环境适应性;压缩机和膨胀机通过良导热体连接散热,可平衡温差,便于控温. 相似文献
6.
A cryocooler survey has been performed on data of 235 cryocoolers, with cooling powers below some tens of watts and operating between 4 and 120 K. The state-of-the-art is discussed and trends are investigated on cooling performance, mass and size, cost, lifetime and reliability. The data were compared with earlier surveys to explore historical trends. Improvements in cooling performance were mainly in 80 K cryocoolers, an increase in efficiency by about a factor of 5. Coolers did not reduce in size significantly. Main reduction was in 80 K coolers because of the higher efficiency. In the survey, cost is related to input power, cooling power and operating temperature. Cost development is considered and related to learning curves. Since the mid-90s, the lifetime of Stirling-type cryocoolers has increased by one order of magnitude from typically 0.5 to 5 years or more. The confusion that exists on the term “reliability” is discussed. 相似文献
7.
8.
Summary This paper extends earlier work on the stationary queue length distribution of a bulk service system with finite waiting space by considering two queueing systems. The first system incorporates the feature of batch arrivals with group service; it has compound Poisson input, general service times and a single server with variable batch capacity. The second system has individually arriving customers with Erlangian interarrival time distribution, general service times and a single server with variable batch capacity.The financial support of the National Research Council of Canada, under Research Grants No. 3-644-189-60; NRC-A5639 and No. 3-641-189-10; NRC-A2796, is acknowledged. 相似文献
9.
介绍了空间用斯特林制冷机的主要失效模式和失效机理,国内外寿命评价研究的状况和进展,分析了几种加速寿命评价方法.针对中国空间用制冷机寿命评价研究的现状,提出了加速寿命评价的一些见解和思路. 相似文献
10.
Northrop Grumman Aerospace Systems cryocooler overview 总被引:1,自引:0,他引:1
Mechanical long life cryocoolers are an enabling technology used to cool a wide variety of detectors in space applications. These coolers provide cooling over a range of temperatures from 2 K to 200 K, cooling powers from tens of mW to tens of watts. Typical applications are missile warning, Earth and climate sciences, astronomy and cryogenic propellant management. Northrop Grumman Aerospace Systems (NGAS) has delivered many of the US flight cooler systems and has 12 long life pulse tube and Stirling coolers on orbit with two having over 11 years of continuous operation. This paper will provide an overview of the NGAS cryocooler capabilities. 相似文献
11.
A low power closed cycle Stirling refrigerator with a conical glass-fibre reinforced epoxy displacer/regenerator, and an external compressor has been built in our laboratory. The single stage device has demonstrated cooling to 9 K directly from room temperature, and may be used for cooling SQUID systems. 相似文献
12.
13.
14.
The normal operation of high definition Scanning Electronic and Helium Ion microscope tools often relies on maintaining particular components at cryogenic temperatures. This has traditionally been accomplished by using liquid coolants such as liquid Nitrogen. This inherently limits the useful temperature range to above 77 K, produces various operational hazards and typically involves elevated ownership costs, inconvenient logistics and maintenance. Mechanical coolers, over-performing the above traditional method and capable of delivering required (even below 77 K) cooling to the above cooled components, have been well-known elsewhere for many years, but their typical drawbacks, such as high purchasing cost, cooler size, low reliability and high power consumption have so far prevented their wide-spreading. Additional critical drawback is inevitable degradation of imagery performance originated from the wideband vibration export as typical for the operation of the mechanical cooler incorporating numerous movable components.Recent advances in the development of reliable, compact, reasonably priced and dynamically quiet linear cryogenic coolers gave rise to so-called “dry cooling” technologies aimed at eventually replacing the traditional use of outdated liquid Nitrogen cooling facilities. Although much improved these newer cryogenic coolers still produce relatively high vibration export which makes them incompatible with modern high definition microscopy tools. This has motivated further research activity towards developing a vibration free closed-cycle mechanical cryocooler.The authors have successfully adapted the standard low vibration Stirling cryogenic refrigerator (Ricor model K535-LV) delivering 5 W@40 K heat lift for use in vibration-sensitive high definition microscopy. This has been achieved by using passive mechanical counterbalancing of the main portion of the low frequency vibration export in combination with an active feed-forward multi-axes suppression of the residual wideband vibration, thermo-conductive vibration isolation struts and soft vibration mounts. The attainable performance of the resulting vibration free linear Stirling cryocooler (Ricor model K535-ULV) is evaluated through a full-scale experimentation. 相似文献
15.
16.
A method is proposed for stabilizing the operation of a measurement system while adapting it to the on-board measurement conditions.
__________
Translated from Izmeritel’naya Tekhnika, No. 11, pp. 3–9, November, 2006. 相似文献
17.
18.
This paper introduces a new vibration free cryostat cooled by liquid helium and a 4 K pulse tube cryocooler. The cryogenic device mounts on the sample cooling station which is cooled by liquid helium. The boil off helium is recondensed by the pulse tube cryocooler, thus the cryostat maintains zero boil off. There is no mechanical contact between the cryogenic part of the cryocooler and the sample cooling station. A bellows is used to isolate the vibration which could transfer from the cryocooler flange to the cryostat flange at the room temperature. Any vibrations generated by the operation of the cryocooler are almost entirely isolated from the cryogenic device. The cryostat provides a cooling capacity of 0.65 W at 4.21 K on the sample cooling station while maintaining a vapor pressure of 102 kPa. The sample cooling station has a very stable temperature with oscillations of less than ±3 mK during all the operations. A cryogenic microwave oscillator has been successfully cooled and operated with the cryostat. 相似文献
19.