1.
We conducted a longitudinal study to determine the annual rate decline in pulmonary function measurements in male swine confinement workers. For comparison, a grain farming group and a nonfarming rural-dwelling control group were also chosen for the longitudinal study. Two hundred seventeen swine confinement workers, 218 grain farmers, and 179 nonfarming control subjects had valid pulmonary function measurements at the baseline observation conducted in 1990 to 1991 and at the second observation conducted in 1994 to 1995. The swine confinement workers were younger (mean age=38.3+/-11.7 [SD] years) than the nonfarming control subjects (42.6+/-10.4 years) and the grain farmers (44.5+/-11.9 years). When stratified by age, nonfarming control subjects had the lowest mean annual rate decline in FEV1 and FVC in all age categories. The swine confinement workers had the largest annual rate decline in FEV1 and FVC, and this was most obvious in the middle age categories. After controlling for age, height, smoking, and baseline pulmonary function, swine confinement workers had excess annual decline of 26.1 mL in FEV1 (p=0.0005), 33.5 mL in FVC (p=0.0002), and 42.0 mL/s in forced expiratory flow between 25% and 75% of FVC (FEF[25-75%]) (p=0.02) over nonfarming control subjects. Grain farmers had excess annual decline of 16.4 mL in FEV1 (p=0.03), 26.7 mL in FVC (p=0.002), and 11.2 mL/s in FEF(25-75%) (p=0.38) over control subjects. These findings suggest that workers engaged in the swine industry and grain farmers appear prone to accelerated yearly losses in lung function and may therefore be at risk for the future development of chronic airflow limitation.  相似文献   

2.
BACKGROUND: Low level effects of granite dust on one-second forced expiratory volume (FEV1) are estimated in 618 Vermont granite workers followed for 5 years with annual pulmonary function tests. Reduced pulmonary function has already been reported for the subset of subjects lost to follow-up (dropouts) suggesting possible bias in analyses based only on survivors. METHOD: Healthy worker selection bias is directly assessed by comparing the dose-response associations between survivors who remained in the study for the full 5-year observation period and the dropouts. RESULTS: The 353 survivors had an FEV1 of 96% of predicted at baseline and were losing FEV1 at an average rate of 44 ml/yr. No association was found in this group between the rate of FEV1 decline and lifetime dust exposure. However, the 265 workers with incomplete follow-up, 'dropouts', had a lower FEV1 at baseline (94%) and were losing FEV1 at an average rate of 69 ml/yr. The dose-response parameter in this group was estimated to be 4 ml/yr loss per mg/m3-year and was statistically significant. CONCLUSIONS: These results provide an illustration of bias due to the healthy worker effect and an example of the failure to detect a true work-related health effect in a study based only on a 'survivor' population.  相似文献   

3.
We studied 233 male workers employed in two brick-manufacturing plants and 149 matched control workers. The mean age of the brick workers was 35 years, with a mean duration of employment in this industry of 16 years. The prevalence of chronic respiratory symptoms as well as acute symptoms during the work shift were recorded. Lung function was measured on Monday during the work shift by recording maximum expiratory flow-volume (MEFV) curves, from which the forced vital capacity (FVC), the one-second forced expiratory volume (FEV1) and flow rates at 50% and the last 75% of the FVC (FEF50, FEF75) were measured. The results of periodic chest roentgenograms were reviewed. There was a significantly higher prevalence of chronic cough (31.8%), chronic phlegm (26.2%), and chest tightness (24.0%) in exposed workers, compared with control workers (20.1%; 18.1%; 0%) (P < 0.05). This increased symptom frequency was also documented among nonsmokers studied by age and by length of employment, suggesting a work-related effect. Among work shift-related symptoms, high prevalences were noted for upper respiratory tract symptoms (e.g., dry throat, eye irritation, throat irritation). The measured FVC and FEV1 were significantly lower than predicted for brick workers and suggested a restrictive pattern. The mean FVC (as a percent of predicted) was 78.1% and FEV1 was 88.1%. The FEF50 and FEF25 were not significantly decreased. A multiple regression analysis with age, exposure, and smoking as predictors and lung function parameters as response variables showed a significant effect between exposure and FVC. Significant chest roentgenographic abnormalities were not documented. These findings of a restrictive lung function pattern in brick workers with normal chest roentgenograms may suggest early interstitial disease. Additionally, a bronchitic component, as suggested by the respiratory symptoms, may also be present.  相似文献   

4.
An industry-wide pulmonary morbidity study was undertaken to evaluate the respiratory health of employees manufacturing refractory ceramic fibers at five US sites between 1987 and 1989. Refractory ceramic fibers are man-made vitreous fibers used for high temperature insulation. Of the 753 eligible current employees, 742 provided occupational histories and also completed the American Thoracic Society respiratory symptom questionnaire; 736 also performed pulmonary function tests. Exposure to refractory ceramic fibers was characterized by classifying workers as production or nonproduction employees and calculating the duration of time spent in production employment. The risk of working in the production of refractory ceramic fibers and having one or more respiratory symptoms was estimated by adjusted odds ratios and found to be 2.9 (95 percent confidence interval 1.4-6.2) for men and 2.4 (95 percent confidence interval 1.1-5.3) for women. The effect of exposure to refractory ceramic fibers on forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), the ratio of the two (FEV1/FVC), and forced expiratory flow (liters/second) between 25 percent and 75 percent of the FVC curve (FEF(25-75)) was evaluated by multiple regression analysis using transformed values adjusted for height, by dividing by the square of each individual's height. For men, there was a significant decline in FVC for current and past smokers of 165.4 ml (p < 0.01) and 155.5 ml (p = 0.04), respectively, per 10 years of work in the production of refractory ceramic fibers. For FEV1, the decline was significant (p < 0.01) only for current smokers at 134.9 ml. For women, the decline was greater and significant for FVC among nonsmokers, who showed a decrease of 350.3 ml (p = 0.05) per 10 years of employment in the production of refractory ceramic fibers. These findings indicate that there may be important sex differences in response to occupational and/or environmental exposure.  相似文献   

5.
We examined the effects from subjects, technicians and spirometers on within-session variability in successful recordings of forced expiratory volume in 1 second (FEV1) and forced vital capacity (FVC) in 4989 asymptomatic never-smoking men. All eligible men aged 30-46 years living in western Norway (n = 45,380) were invited to a cross-sectional community survey. Information on respiratory symptoms, smoking habits and occupational exposures was obtained from a self-administered questionnaire. Three successful FEV1 and FVC recordings were obtained in 26,368 attendants using three dry-wedge bellow spirometers operated by 10 different technicians. Within-subject standard deviation (SD) from three recordings of FEV1 and FVC was on average 102 and 106 ml, respectively, and increased with height (14 and 17 ml, respectively, per 10 cm) and body mass index (BMI) (11 and 14 ml, respectively, per 5 kg m-2). Between-subject SD of the mean of three FEV1 and FVC recordings was 591 and 754 ml, respectively, and increased in groups of increasing height (43 and 40 ml, respectively, per 10 cm). Small, but significant, differences were observed between technicians in within-subject SD and in levels of FEV1 and FVC. Homogeneity of between-subject variability, necessary for linear regression analysis, was obtained using FEV1 and FVC divided by height squared. In conclusion, within-subject variability in three successful spirometric recordings was small, but dependent on height and BMI of the subjects as well as technician performance. The observed heterogeneity in between-subject variation in FEV1 and FVC levels disappeared when each variable was divided by height squared. Novel multiple linear regression equations for FEV1/height2 and FVC/height2 were developed to be used in evaluating the effects from occupational airborne exposures in Nordic men aged 30-46 years.  相似文献   

6.
To establish the spirometric values for normal, healthy Chinese women in Taiwan, the spirometry of 506 life-long non-smoking, healthy Chinese women was examined, including 140 subjects over the age of 60 years. Significant correlations among age, height and forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1), FEV1/FVC%, peak expiratory flow (PEF), Vmax75, Vmax50, Vmax25 were found. However, there were no significant correlations between age and FEV1/FVC%, nor age and Vmax25 in the elderly group. FEV1 (FEV1*) and FVC (FVC*) were standardized to the overall mean height for elderly women using Cole's formula. The decline in FEV1* and FVC* with age were observed. The predicted value for the average 70-year-old woman with a height of 1.5 m derived from the present study is compared with those from other surveys of the elderly. The values from the present study are somewhat higher than the values from the Hong Kong study. The authors believe the fact that all of the present subjects were life-long non-smokers might explain the differences.  相似文献   

7.
To assess the value of spirometry for predicting the risk of pneumothorax (PTX) following percutaneous fine needle aspiration (FNA) of thoracic lesions, we examined retrospectively the incidence of PTX in 89 FNA and associated spirometry. Spirometry results were classified as normal, obstructed, or restrictive. Overall, the PTX rate was 20 percent. When the PTX occurrence was analyzed based on our spirometry classification, no significant difference was found between the groups. A PTX occurred in 27.8 percent of the FNA performed in patients with normal spirometry. On further analysis of specific spirometry measurements (FEV1, FVC, FEV1 percent predicted, and FEV1/FVC) and incidence of PTX, no significant correlation in PTX rates was found. These data suggest that the FNA pneumothorax is not correlated with lung function as measured by routine spirometry.  相似文献   

8.
To evaluate the presence of asbestos-related pleural and parenchymal abnormalities and their correlation with pulmonary function and smoking habits, 119 asbestos-exposed asymptomatic workers (mean age, 46.2 years; mean duration of asbestos exposure, 8.6 years; mean latency time, 21.6 years) with normal standard P.A chest radiographs were submitted to HRCT, CO-diffusing capacity and pulmonary function tests. HRCT scans were normal only in 31 (26%) examined workers; 31 (26%) subjects showed both pleural and parenchymal involvement, and 50 (42%) and seven (6%) had exclusively pleural and parenchymal abnormalities, respectively. Based on CO-diffusing capacity and pulmonary function tests, no significant difference was demonstrated between workers with pleural lesions and subjects with normal pleura; however, lower values of FVC were observed in the nonsmoking workers with parenchymal abnormalities in comparison with nonsmoking subjects with normal parenchyma (78.2 vs. 89.7% of predicted values; p = 0.03 by student's two-tailed t test), and lower values of FEV1/FVC in the smokers with parenchymal lesions with respect to smokers with normal parenchyma (93.7 vs. 100.2% of predicted values; p = 0.005 by students' two-tailed t test). In conclusion, our results demonstrate that HRCT may detect early parenchymal abnormalities which correlate with exposure to asbestos and respiratory function impairment, including a reduction in obstructive indices in smokers occupationally exposed to asbestos, without any clinically evident disease.  相似文献   

9.
Follow-up study of respiratory function was carried out in a group of 311 male workers employed in one rubber industry. The prevalence of respiratory symptoms and ventilatory capacity were recorded over te period of six years. Lung function was measured by recording maximum expiratory flow-volume (MEFV) curves on which forced vital capacity (FVC), one-second forced expiratory volume (FEVI) and flow rates at 50% and the last 25% of the vital capacity (FEF50, FEF25) were read. The prevalence of all chronic respiratory symptoms was higher during the follow-up study although not statistically significant (p > 0.05). During both studies smokers had significantly higher prevalence of chronic cough, chronic phlegm and chronic bronchitis than nonsmokers (p < 0.05 or < 0.025). Measured values of ventilatory capacity were significantly lower than predicted normal values during both studies (p < 0.01). Percentage of predicted values were lower during the follow-up study in comparison to that during the initial study. The mean lowest percentages were obtained for FEF25 (initial study: 77.4%; follow-up study: 70.5%). Smokers had larger mean annual decrease of FVC: 0.073 L; FEVI: 0.063 L; FEF50: 0.100 L/s; FEF25: 0.085 L/s than nonsmokers (FVC: 0.063 L; FEVI: 0.058 L; FEF50: 0.083 L/s; FEF25: 0.058 L/s). Workers exposed for more than 10 years had larger mean annual decrease of ventilatory capacity tests than hose with shorter exposure. Our data indicate that exposure to noxious agents in rubber industry may be responsible for the development of chronic respiratory symptoms and chronic lung function changes.  相似文献   

10.
This study was undertaken to examine the long term relationship between lung function, smoking and exposure to enzymes in the detergent industry. A total of 731 male workers from five locations in the United Kingdom were subject to respiratory health surveillance including lung function testing over a period of 4-20 years. Exposure groups were defined by job history. Significantly different rates of fall in FEV1 and FVC with time were found by geographical location and by smoking habit, but there were no consistent trends with enzyme exposure.  相似文献   

11.
Work-related respiratory symptoms, acute lung function changes and personal endotoxin exposure were studied in 61 workers from a potato processing plant. According to their job title mean endotoxin exposure level, workers were divided into low (AM = 21 EU/m3) and high (AM = 56 EU/m3) exposure categories. Shortness of breath and chest tightness during work were reported by 18% and 16% of the workers, respectively, mainly in the low endotoxin exposure category. A total of 148 across-shift lung function changes were measured during three consecutive afternoon shifts. The mean FEV1 and MMEF showed a decrease over the work shift, being largest on the first working day after a 3-day absence from work. Workers exposed to high endotoxin levels showed a larger across-shift decrease in lung function than workers exposed to low endotoxin exposures, the effect being most pronounced on the first day after a 3-day absence from work. At the start of the second work shift, FVC, FEV1 and MMEF were lower than at the start of the first work shift. This difference was larger for high exposed workers. High exposed workers with work-related respiratory symptoms showed an 8-10% across-shift change in FVC, FEV1 and MMEF We conclude that significant across-shift decreases in lung function of potato processing workers is related to endotoxin exposure levels above 53 EU/m3 over 8 hr.  相似文献   

12.
In order to determine both clinical and spirometric changes due to high environmental concentrations of wheat dust at a wheat processing plant mill, 48 exposed men and 48 age and antroprometrically-matched, non-exposed apparently healthy men were studied. In both groups a medical and occupational history were taken, and spirometric measurements were carried out, that included Forced Vital Capacity (FVC), Forced Expiratory Volume at the first second (FEV1), Peak Flow Rate (PFR), Forced Percentual Expiratory Volume (FEV%), Forced Percentual Vital Capacity (FVC%), Forced Expiratory Flow at 25% (FEV25%), at 50% (FEV50%) and at 75% (FEV75%) of their Forced Vital Capacity, which were analyzed through Corzo's predictive equations and the lung deterioration's criteria by USA's Thoracic Association. The environmental wheat dust was determined by gravimetry and its concentration was higher than the legally admitted (3/5, 60%). There was a decrease in the PFR, FEV%, FEV25% and FEV75%. (p < 0.05). In addition, 4 restrictive and 1 obstructive syndrome were detected in the exposed workers and none in the control group. The spirometric values diminished in a positive correlation with the time of exposure and smoking habits. There was no correlation between the clinical findings and the dust concentration but it did exist with the spirometric values. It is concluded that in this plant, the wheat dust exposed workers have a diminished spirometric values.  相似文献   

13.
The goals of this study were (a) to assess the extent to which construction industry workplace injuries and illness are underreported, and (b) to determine whether safety climate predicts the extent of such underreporting. Data from 1,390 employees of 38 companies contracted to work at a large construction site in the northwestern United States were collected to assess the safety climate of the companies. Data from the Occupational Safety and Health Administration (OSHA) logs kept by the contractors allowed for calculation of each company's OSHA recordable injury rate (i.e., the reported injury rate), whereas medical claims data from an Owner-Controlled Insurance Program provided the actual experienced rate of injuries for those same companies. While the annual injury rate reported to OSHA was 3.11 injuries per 100 workers, the rate of eligible injuries that were not reported to OSHA was 10.90 injuries per 100 employees. Further, organizations with a poor safety climate had significantly higher rates of underreporting (81% of eligible injuries unreported) compared with organizations with a positive safety climate (47% of eligible injuries unreported). Implications for organizations and the accuracy of the Bureau of Labor Statistics's national occupational injury and illness surveillance system are discussed. (PsycINFO Database Record (c) 2010 APA, all rights reserved)  相似文献   

14.
STUDY OBJECTIVE: To investigate the effect of Pseudomonas aeruginosa infection on clinical parameters in Chinese patients with noncystic fibrosis and steady-state bronchiectasis. DESIGN: Prospective, cross-sectional clinicomicrobiological study with informed consent. SETTING: Consecutive outpatient recruitment from a specialist bronchiectasis respiratory clinic. PATIENTS: Outpatients (n = 100; 62 women; 55.1+/-16.7 years old; FEV1/FVC 1.4+/-0.7/2.1+/-0.9 L), who had stable respiratory symptoms for more than 3 weeks. MEASUREMENTS AND RESULTS: Respiratory pathogens isolated from the sputum were: Pseudomonas aeruginosa (33), Haemophilus influenzae (10), Moraxella catarrhalis (2), other Gram-negative bacilli (5), Streptococcus pneumoniae (6), Staphylococcus aureus (5), mycobacteria (3), and yeast (1). Clinical parameters in patients with positive isolation of P aeruginosa were compared with those without the organism in the sputum culture (non-P aeruginosa). In the P aeruginosa group, the FEV1/FVC ratio and sputum volume were lower (p < 0.005) and higher (p < 0.0001), respectively, than those of the non-P aeruginosa group. The FEV1/FVC ratio (< 60%) and sputum volume (grading > 5) were independently associated with a positive sputum isolation of P aeruginosa with odds ratios of 3.1 (confidence interval [CI] 1.2 to 8.4; p < 0.01) and 4.7 (CI 1.6 to 13.3; p < 0.001), respectively. CONCLUSIONS: P aeruginosa is the predominant respiratory pathogen isolated in the sputum of Chinese patients with steady-state bronchiectasis, and its isolation is associated with high sputum output (> or = 75th quartile) and moderately severe airflow obstruction (FEV1/FVC < 60%).  相似文献   

15.
The effects of electrical stimulation (ES) on degradation of titin, nebulin, desmin, and troponin-T (TN-T) and on structural changes in the longissimus muscle (LM) from Brahman x Simmental (B x S) cattle (Bos indicus cross) were determined. The left side of seven B x S beef carcasses was stimulated (200 V, 20 Hz) within 1 h of death, and the right side was the nonstimulated (NS) control. Myofibrils for SDS-PAGE and samples for transmission electron microscopy were prepared from the LM at 0, 1, 3, 7, 14, and 28 d postmortem (PM). The SDS-PAGE results showed that the T1 band of titin was absent by 7 d in two animals, by 14 d in four animals, and by 28 d in one animal in both NS and ES samples. By SDS-PAGE, intact nebulin was gone by 7 d in two animals and by 14 d in five animals, but in blots, nebulin decreased by 7 d and was absent by 14 d in both NS and ES samples. The desmin band could still be seen as a light band at 28 d in Western blots of both NS and ES samples. A decrease in TN-T and a concomitant increase in the 30-kDa polypeptide were observed in both NS and ES samples. Western blots with a monoclonal antibody to TN-T confirmed that TN-T decreased at similar rates in NS and ES samples but showed that the 30-kDa polypeptide was more heavily labeled in ES samples from 7 to 28 d. Contraction nodes were present in O-d ES samples and were still observed in 28-d ES samples. Narrow, intermediate, and wide I-band fractures were seen earlier and at a greater frequency in ES than in NS samples. Overall, ES had no detectable effect on titin, nebulin, desmin, or TN-T degradation but accelerated the appearance and enhanced the frequency of three types of I-band fractures in the LM from Bos indicus crossbred cattle.  相似文献   

16.
We investigated the relationship between the pulmonary test variable measurements and self-reported asthma and wheezing from a cross-sectional study conducted in Saskatchewan. Based on the responses to the questionnaire, the subjects were classified into asthmatic, wheezing, and asymptomatic groups. For both male and female subjects the mean values of forced expiratory volume in 1 s (FEV1), forced expiratory flow during the middle half of the forced vital capacity (FEF25-75), and FEV1/FVC ratio were lowest in asthmatics, followed by wheezing and asymptomatic groups, respectively. This trend was also observed in forced vital capacity (FVC) for men but not for women. After adjusting for current smoking status, the trend in the means across the three groups was statistically significant in men for FEV1 (p = 0.03), FEF25-75 (p = 0.002), and FEV1/FVC ratio (p = 0.002) and in women for FEF25-75 (p < 0.001) and FEV1/FVC ratio (p < 0.001). The differences in the adjusted means of FVC, FEV1, FEF25-75, and FEV1/FVC ratio between asymptomatic subjects and the other two groups were significant in both male and female subjects. Significant differences were also observed between asthmatics and wheezing groups in the adjusted means of FEF25-75 and FEV1/FVC ratio in male and female subjects. We conclude that the self-report of asthma has a high level of validity against the criterion of concurrently measured pulmonary test variables.  相似文献   

17.
18.
The world's worst chemical industrial disaster, which occurred at Bhopal on 2-3 December, 1984, resulted in considerable respiratory morbidity in the exposed population. Therefore, a study was planned to evaluate the relationship between lower respiratory tract inflammation, lung function and severity of exposure. Sixty patients exposed to methyl isocyanate and presenting with respiratory symptoms were studied using bronchoalveolar lavage (BAL) 1-7 yrs after the accident. Pulmonary function tests included forced vital capacity (FVC) and forced expiratory volume in one second (FEV1). An index of severity of exposure was derived retrospectively on the basis of the acute symptoms in the victims themselves or the occurrence of death among their family members. Total lung inflammatory cells (p < 0.01) and absolute numbers of macrophages (p = 0.01) and lymphocytes (p < 0.05) increased as severity of exposure increased. FEV1/FVC % (p = 0.05) was also significantly lower as severity of exposure increased. Moderately exposed subjects had significantly lower FEV1/FVC % (p < 0.05) compared to those mildly exposed. In nonsmokers, BAL neutrophils, both percentage and absolute numbers, showed significant negative correlations with FEV1 % predicted (rs = -0.350, p < 0.05; and rs = -0.374, p < 0.01, respectively). Neutrophil percentage was negatively correlated with FEV1/FVC % (rs = -0.378; p < 0.01). Absolute lymphocytes had significant negative correlations with FVC % pred (rs = -0.318; p < 0.05). Macrophages had significant positive correlations with FVC % pred (rs = 0.322; p < 0.05) and FEV1 % pred (rs = 0.433; p < 0.01). Radiographic abnormalities (International Labour Organization (ILO) classification) were associated with decline in FEV1 % pred (p < 0.05). This study suggests that pulmonary function abnormalities occur in gas-exposed subjects as a consequence of an abnormal accumulation of lung inflammatory cells (lymphocytes and neutrophils), and that the intensity of lung inflammation and reduction in pulmonary function are greater in severely exposed subjects. As it has been observed that decline in pulmonary function is associated with radiographic abnormalities, there is a suggestion that injury following toxic gas exposure can lead to irreversible lung damage.  相似文献   

19.
Work place environment plays an important role in development diseases because of the time spend in and different toxic factors placed in it. The aim of study was to assess the ventilatory efficiency in individuals employed in Generating Plant (GP) in relation to the pollution of the work place and the tobacco smoking habit during 3 years. The study covered a group of 144 male individuals employed at GP. (age 39.3 +/- 8.7 yrs, period of employment 20.3 +/- 8.6 yrs, smokers 53.5%. Lung function tests consisted of VC, FVC, FEV1, FEV1%VC, PEF, FEF50 counted from flow-volume curve and TGV, Rt measured using pletysmographic method. All tests were performed using pletysmograph (Masterlab) "Jaeger" placed on the ambulance near to the work place. The measurements were taken in May 1993 and 1996. Results were compared to with normal values (acc. ECSC). The anamnesis was obtained from all workers in the form of questionnaire projected for this study. All measurements were done during work time (9.00 a.m. to 2.00 p.m.). Mean values of the ventilation indices remained within the normal range but comparing results in smokers and non-smokers group significant differences in FEV1 and TGV were found. The symptoms of chronic bronchitis were present in 20.8% of persons. Spirometric criteria for the COPD diagnosis were found in 16 persons (11%). Only 5 persons (31%) were symptomatic. The mean decrease of FEV1 was 16.2 ml/yr, in the COPD group it was 82.5 ml/yr. The greater annual loss of FEV1 was found in the smokers and symptoms groups.  相似文献   

20.
STUDY OBJECTIVE: To evaluate the short-form 36-item questionnaire (SF-36) as an instrument for measuring health-related quality of life (HRQL) in patients with symptomatic COPD. DESIGN: Observational data at a single point in time. SETTING: Outpatient pulmonary clinic. PATIENTS: Fifty male patients with COPD and no significant comorbidity. MEASUREMENTS AND RESULTS: HRQL was assessed with the SF-36, which consists of 36 questions that cover nine health domains. Clinical ratings of dyspnea were measured by the multidimensional baseline dyspnea index (BDI). Pulmonary function tests included forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1), and maximal inspiratory mouth pressure (PImax). The mean (+/- SD) age of the patients was 72 +/- 8 years. The BDI focal score was 5.6 +/- 2.3, FEV1 was 1.32 +/- 0.60 L (48 +/- 22% pred), and PImax was 62 +/- 23 cm H2O. The BDI focal score was significantly correlated with seven of nine components of the SF-36 (range of r, 0.42 to 0.91; p < 0.05). The FEV1 percent of predicted and PImax were significantly correlated with five of nine health components (range of r, 0.30 to 0.65 and 0.31 to 0.61, respectively). Using linear regression model analysis with the different SF-36 components as the dependent variable and BDI, FVC, FEV1, and PImax as independent variables, the BDI score was the only significant predictor of social and physical functioning, role-physical, vitality, pain, health perceptions, and health transition (p < 0.05). CONCLUSIONS: The SF-36 is a valid instrument to measure HRQL in patients with COPD. The severity of dyspnea but not respiratory function was a significant predictor of various components of HRQL.  相似文献   