 共查询到20条相似文献,搜索用时 31 毫秒
1.
The effect of pulsed electric fields on two-phase flow patterns, heat transfer and pressure drop in horizontal tube side convective condensation was investigated. Experiments were performed for an applied pulse voltage of 8 kV at pulse repetition rates in the range of 0.5 Hz–1.5 kHz and duty cycles of 25%, 50% and 75%. Three mass fluxes of 55, 100, and 150 kg/m2 s were tested with an average vapour quality of 45% which corresponds to an initially stratified flow. The voltage was applied through a central electrode along the centerline of the tube. Changing the pulse repetition rate and duty cycle results in different flow patterns and therefore in different values of heat transfer and pressure drop. For a given mass flux, the heat transfer enhancement due to the applied voltage decreased with the pulse repetition rate and reached a plateau. The pressure drop ratio, however, increased with pulse repetition rate and reached a maximum before decreasing with a further increase in pulse repetition rate.  相似文献   

2.
An empirical setup has been established to study heat transfer and pressure drop characteristics during condensation of R600a, a hydrocarbon refrigerant, in a horizontal plain tube and different flattened channels. Round copper tubes of 8.7 mm I.D. were deformed into flattened channels with different interior heights of 6.7 mm, 5.2 mm and 3.1 mm as test sections. The test conditions include heat flux of 17 kw/m2, mass velocity in the range of 154.8–265.4 kg/m2s and vapor quality variation from approximately 10% to 80%. Results indicate that flattening the tubes causes significant enhancement of heat transfer coefficient which is also accompanied by simultaneous augmentation in flow pressure drop. Therefore, the overall performance of the flattened tubes with respect to heat transfer enhancement considering the pressure drop penalty is analyzed. It is concluded that the flattened tube with 5.2 mm inner height tube has the best overall performance. Due to the failure of pre-existing correlations for round tube condensation heat transfer, a new correlation is proposed which predicts 90% of the entire data within ± 17% error.  相似文献   

3.
The boiling heat transfer of refrigerant R-134a flow in horizontal small-diameter tubes with inner diameter of 0.51, 1.12, and 3.1 mm was experimentally investigated. Local heat transfer coefficient and pressure drop were measured for a heat flux ranging from 5 to 39 kW/m2, mass flux from 150 to 450 kg/m2 s, evaporating temperature from 278.15 to 288.15 K, and inlet vapor quality from 0 to 0.2. Flow patterns were observed by using a high-speed video camera through a sight glass at the entrance of an evaporator. Results showed that with decreasing tube diameter, the local heat transfer coefficient starts decreasing at lower vapor quality. Although the effect of mass flux on the local heat transfer coefficient decreased with decreasing tube diameter, the effect of heat flux was strong in all three tubes. The measured pressure drop for the 3.1-mm-ID tube agreed well with that predicted by the Lockhart–Martinelli correlation, but when the inner tube diameter was 0.51 mm, the measured pressure drop agreed well with that predicted by the homogenous pressure drop model. With decreasing tube diameter, the flow inside a tube approached homogeneous flow. The contribution of forced convective evaporation to the boiling heat transfer decreases with decreasing the inner tube diameter.  相似文献   

4.
A complete solution for boiling phenomena in smooth tubes has been giving as a procedure regarding with the calculation of convective heat transfer coefficient and pressure drop using accurate experimental data validated by flow regime maps and sight glasses on the experimental facility. The experimental study is conducted in order to investigate the effect of operating parameters on flow boiling convective heat transfer coefficient and pressure drop of R134a. The smooth tube having 8.62 mm inner diameter and 1100 mm length is used in the experiments. The effect of mass flux, saturation temperature and heat flux is researched in the range of 290–381 kg/m2 s, 15–22 °C and 10–15 kW/m2, respectively. The experiments revealed that the heat transfer coefficient and pressure drop are significantly affected by mass flux for all tested conditions. Moreover, the experimental results are compared with well-known heat transfer coefficient and frictional pressure drop correlations given in the literature. In addition, 122 number of heat transfer and pressure drop raw experimental data is given for researchers to validate their theoretical models.  相似文献   

5.
An experimental investigation has been carried out to study the effect of twisted tape inserts on heat transfer enhancement and pressure drop in a horizontal tube during swirl flow boiling of R-134a. The test-evaporator was an electrically heated horizontal copper tube and twisted tapes with different twist ratios of 6, 9, 12 and 15 were inserted one by one. The data were acquired at the refrigerant mass velocities of 54, 86, 114 and 136 kg/s m2. The twisted tape inserts increases the boiling heat transfer coefficients and the pressure drop across the test-evaporator. An empirical correlation has also been developed to predict the swirl flow pressure drop in the test-evaporator.  相似文献   

6.
This paper presents the heat transfer coefficients and the pressure drop measured during HFC refrigerants 236fa, 134a and 410A saturated vapour condensation inside a brazed plate heat exchanger: the effects of saturation temperature (pressure), refrigerant mass flux and fluid properties are investigated. The heat transfer coefficients show weak sensitivity to saturation temperature (pressure) and great sensitivity to refrigerant mass flux and fluid properties. A transition point between gravity controlled and forced convection condensation has been found for a refrigerant mass flux around 20 kg/m2s that corresponds to an equivalent Reynolds number around 1600–1700. At low refrigerant mass flux (Gr < 20 kg/m2s) the heat transfer coefficients are not dependent on mass flux and are well predicted by the Nusselt [20] analysis for vertical surface: the condensation process is gravity controlled. For higher refrigerant mass flux (Gr > 20 kg/m2s) the heat transfer coefficients depend on mass flux and are well predicted by Akers et al. [21] equation: forced convection condensation occurs. In the forced convection condensation region the heat transfer coefficients show a 25–30% increase for a doubling of the refrigerant mass flux.The frictional pressure drop shows a linear dependence on the kinetic energy per unit volume of the refrigerant flow and therefore a quadratic dependence on mass flux.HFC-410A shows heat transfer coefficients similar to HFC-134a and 10% higher than HFC-236fa together with frictional pressure drops 40-50% lower than HFC-134a and 50–60% lower than HFC-236fa.  相似文献   

7.
Boiling heat transfer characteristics of nitrogen were experimentally investigated in a stainless steel plain tube and wire coil inserted tubes. Wire coils having different coil pitches and wire thicknesses were inserted into a horizontally positioned plain tube, which had an inner diameter of 10.6 mm and a length of 1.65 m. The coil pitches were 18.4, 27.6, and 36.8 mm, and the wire thicknesses were 1.5, 2.0, and 2.5 mm. Tests were conducted at a saturation temperature of −191 °C, mass fluxes from 58 to 105 kg/m2 s, and heat fluxes from 22.5 to 32.7 kW/m2. A direct heating method was used to apply heat to the test tube. The boiling heat transfer coefficients of nitrogen significantly decreased when the dryout occurred. Enhancement performance ratio (EPR), which is the ratio of heat transfer enhancement factor to pressure drop ratio, was used to evaluate the performance of the wire coil inserts. The maximum heat transfer enhancement of the wire coil inserted tubes over the plain tube was 174% with wire 3 having a twist ratio (p/Dw) of 1.84 and a thickness ratio (t/Dw) of 0.25. Wire 3-inserted tube showed the highest EPR among the tested tubes in this study.  相似文献   

8.
Two-phase flow phenomena were investigated while boiling R113 and n-pentane in a 241-tube thin slice kettle reboiler. For heat fluxes between 10 and 40 kW/m2, row pressure drop measurements were made in three columns and visual observations of the flow patterns were recorded by a video camera. The height of the two-phase mixture above the tube bundle was also varied. The results revealed that the height of the mixture had little effect on the row pressure drop distribution in each column. At heat fluxes below 10 kW/m2, the pressure drops were reasonably constant. However, at heat fluxes greater than this, the row pressure drop continuously declined.Two one-point-five-dimensional models were developed, one to aid the investigation of static liquid driven lateral flow in the tube bundle, and another to aid the investigation of the cause of the change from reasonably constant to continually declining row pressure drop. The data and the analysis showed that the flow within the tube bundle was always two-dimensional and that the flow pattern was dominated by the static liquid at the tube bundle edge when the heat flux was less than 10 kW/m2. This corresponded to the bubbly flow regime. At larger heat fluxes, the flow pattern changed to intermittent flow. The change occurred when the Kutateladze number was 1.09. Declining row pressure drops occurred in this latter flow regime.  相似文献   

9.
The two-phase heat transfer coefficient and pressure drop of HFC-134a during evaporation inside a smooth helically coiled concentric tube-in-tube heat exchanger are experimentally investigated. The test section is a 5.786-m long helically coiled tube with refrigerant flowing in the inner tube and heating water flowing in the annulus. The inner tube is made from copper tubing of 9.52 mm outer diameter and 7.2 mm inner diameter. The heat exchanger is fabricated by bending a straight copper tube into a spiral coil. The diameter of coil is 305 mm. The test run are done at average saturated evaporating temperatures ranging between 10 and 20 °C. The mass fluxes are between 400 and 800 kg m−2 s−1 and the heat fluxes are between 5 and 10 kW m−2. The inlet quality of the refrigerant in the test section is calculated using the temperature and pressure obtained from the experiment. The pressure drop across the test section is directly measured by a differential pressure transducer. The effects of heat flux, mass flux and, evaporation temperature on the heat transfer coefficients and pressure drop are also discussed. The results from the present experiment are compared with those obtained from the straight tube reported in the literature. New correlations for the convection heat transfer coefficient and pressure drop are proposed for practical applications.  相似文献   

10.
Measurements of two-phase flow pressure drop have been made during a phase-change heat transfer process with refrigerant (R-134a) as a working fluid for a wide range of pressures right up to the critical pressure. The experiments were conducted in a uniformly heated vertical tube of 12.7 mm internal diameter and 3 m length over a heat flux range of 35–80 kW/m2, mass flux range of 1200–2000 kg/m2 s, exit quality range of 0.19–0.81 and for reduced pressures ranging from 0.24 to 1 with a fixed inlet subcooling of 3 °C. The measurements were compared with the predictions from the homogeneous flow model, a separated flow model using correlations drawn from the literature for void fraction and frictional pressure drop, and finally, using a flow pattern-based predictive method accounting specifically for bubbly, slug and annular flow regimes. It was found that the best results were obtained with the flow pattern-based approach with a mean deviation of ±20% over the entire pressure range.  相似文献   

11.
The two-phase heat transfer coefficient and pressure drop of pure HFC-134a condensing inside a smooth helically coiled concentric tube-in-tube heat exchanger are experimentally investigated. The test section is a 5.786 m long helically coiled double tube with refrigerant flowing in the inner tube and cooling water flowing in the annulus. The inner tube is made from smooth copper tubing of 9.52 mm outer diameter and 8.3 mm inner diameter. The outer tube is made from smooth copper tubing of 23.2 mm outer diameter and 21.2 mm inner diameter. The heat exchanger is fabricated by bending a straight copper double-concentric tube into a helical coil of six turns. The diameter of coil is 305 mm. The pitch of coil is 35 mm. The test runs are done at average saturation condensing temperatures ranging between 40 and 50 °C. The mass fluxes are between 400 and 800 kg m−2 s−1 and the heat fluxes are between 5 and 10 kW m−2. The pressure drop across the test section is directly measured by a differential pressure transducer. The quality of the refrigerant in the test section is calculated using the temperature and pressure obtained from the experiment. The average heat transfer coefficient of the refrigerant is determined by applying an energy balance based on the energy rejected from the test section. The effects of heat flux, mass flux and, condensation temperature on the heat transfer coefficients and pressure drop are also discussed. It is found that the percentage increase of the average heat transfer coefficient and the pressure drop of the helically coiled concentric tube-in-tube heat exchanger, compared with that of the straight tube-in-tube heat exchanger, are in the range of 33–53% and 29–46%, respectively. New correlations for the condensation heat transfer coefficient and pressure drop are proposed for practical applications.  相似文献   

12.
An innovative cooling system based on evaporative CO2 two-phase flow is under investigation for the tracker detectors upgrade at CERN (European Organization for Nuclear Research). The radiation hardness and the excellent thermodynamic properties emphasize carbon dioxide as a cooling agent in the foreseen minichannels. A circular stainless steel tube in horizontal orientation with an inner diameter of 1.42 mm and a length of 0.3 m has been used as a test section to perform the step-wise scanning of the vapor quality in the entire two-phase region. To characterize the heat transfer and the pressure drop depending on the vapor quality in the tube, measurements have been performed by varying the mass flux from 300 to 600 kg/m2 s, the heat flux from 7.5 to 29.8 kW/m2 and the saturation temperature from ?40 to 0 °C (reduced pressures from 0.136 to 0.472). Heat transfer coefficients between 4 kW/m2 K and 28 kW/m2 K and pressure gradients up to 75 kPa/m were registered. The measured data was analyzed corresponding to the dependencies on heat flux, mass flux and saturation temperature. A database has been established containing about 2000 measurement points. The experimental data was compared with common models recently developed by Cheng et al. [1], [2] to cross check their applicability. The overall trends and experimental data were reproduced as predicted by the models before the dryout onset, and deviations have been analyzed. A modified friction factor for the pressure drop model [1] in mist flow has been proposed based on the experimental data.  相似文献   

13.
The boiling in cross-flow is investigated for coated tubes (low-porosity, flame-sprayed) in this paper. The effect of surface roughness on flow boiling heat transfer for a horizontal tube surface in cross-flow is studied for saturated boiling of water at atmospheric pressure. The parameters varied were for flow velocity up to 3.24 kg/s (G = 258.49 kg/m2 s), heat flux from 12 to 45 kW/m2, surface roughness (Ra) from 0.3296 to 4.731 μm. Nominal enhancement in heat transfer coefficient at higher mass flux may be attributed to the continued nucleation at the uppermost surfaces (in the wake region of the flow) of the rougher tubes thereby increasing the overall heat transfer rate. The flow boiling data was found to best fit the Kutateladze asymptotic equation h = hl[1 + (hnpb/hl)n]1/n with the value of n = 2.258 (which is close to the value of n = 2 suggested by Kutateladze).  相似文献   

14.
Natural convection flows in a square cavity filled with a porous matrix has been studied numerically using penalty finite element method for uniformly and non-uniformly heated bottom wall, and adiabatic top wall maintaining constant temperature of cold vertical walls. Darcy–Forchheimer model is used to simulate the momentum transfer in the porous medium. The numerical procedure is adopted in the present study yields consistent performance over a wide range of parameters (Rayleigh number Ra, 103  Ra  106, Darcy number Da, 10−5  Da  10−3, and Prandtl number Pr, 0.71  Pr  10) with respect to continuous and discontinuous thermal boundary conditions. Numerical results are presented in terms of stream functions, temperature profiles and Nusselt numbers. Non-uniform heating of the bottom wall produces greater heat transfer rate at the center of the bottom wall than uniform heating case for all Rayleigh numbers but average Nusselt number shows overall lower heat transfer rate for non-uniform heating case. It has been found that the heat transfer is primarily due to conduction for Da  10−5 irrespective of Ra and Pr. The conductive heat transfer regime as a function of Ra has also been reported for Da  10−4. Critical Rayleigh numbers for conduction dominant heat transfer cases have been obtained and for convection dominated regimes the power law correlations between average Nusselt number and Rayleigh numbers are presented.  相似文献   

15.
Experiments have been carried out to determine annular condensation heat transfer coefficient of steam in two silicon microchannels having trapezoidal cross sections with the same aspect ratio of 3.15 at 54 < G < 559 kg/m2 s under 3-side cooling conditions. A semi-analytical method, based on turbulent flow boundary layer theory of liquid film with correlations of pressure drop and void fraction valid for microchannels, is used to derive the annular local condensation heat transfer coefficients. The predicted values based on the semi-analytical model are found within ±20% of 423 data points. It is shown that the annular condensation heat transfer coefficient in a microchannel increases with mass flux and quality and decreases with the hydraulic diameter.  相似文献   

16.
Experimental investigations of tube side condensation and evaporation in two 3-D enhanced heat transfer (2EHT) tubes were compared to the performance of a smooth surface copper tube. The equivalent outer diameter of all the tubes was 12.7 mm with an inner diameter of 11.5 mm. Both the inner and outer surfaces of the 2EHT tubes are enhanced by longitudinal grooves with a background pattern made up by an array of dimples/embossments. Experimental runs were performed using R410A as the working fluid, over the quality range of 0.2–0.9. For evaporation, the heat transfer coefficient ratio (compares the heat transfer coefficient of the enhanced tube to that of a smooth tube) of the 2EHT tubes is 1.11–1.43 (with an enhanced surface area ratio of 1.03) for mass flux rate that ranges from 80 to 200 kg/m2 s. For condensation, the heat transfer coefficient ratio range is 1.1–1.16 (with an enhanced surface area ratio of 1.03) for mass flux that ranges from 80 to 260 kg/m2 s. Frictional pressure drop values for the 2EHT tubes are very similar to each other. Heat transfer enhancement in the 2EHT tubes is mainly due to the dimples and grooves in the inner surface that create an increased surface area and interfacial turbulence; producing higher heat flux from wall to working fluid, flow separation, and secondary flows. A comparison was performed to evaluate the enhancement effect of the 2EHT tubes using a defined performance factor and this indicates that the 2EHT tubes provides a better heat transfer coefficient under evaporation conditions.  相似文献   

17.
A numerical study to investigate the steady laminar natural convection flow in a square cavity with uniformly and non-uniformly heated bottom wall, and adiabatic top wall maintaining constant temperature of cold vertical walls has been performed. A penalty finite element method with bi-quadratic rectangular elements has been used to solve the governing mass, momentum and energy equations. The numerical procedure adopted in the present study yields consistent performance over a wide range of parameters (Rayleigh number Ra, 103  Ra  105 and Prandtl number Pr, 0.7  Pr  10) with respect to continuous and discontinuous Dirichlet boundary conditions. Non-uniform heating of the bottom wall produces greater heat transfer rates at the center of the bottom wall than the uniform heating case for all Rayleigh numbers; however, average Nusselt numbers show overall lower heat transfer rates for the non-uniform heating case. Critical Rayleigh numbers for conduction dominant heat transfer cases have been obtained and for convection dominated regimes, power law correlations between average Nusselt number and Rayleigh numbers are presented.  相似文献   

18.
Experimental heat transfer studies during evaporation of R-134a inside a corrugated tube have been carried out. The corrugated tube has been provided with different tube inclination angles of the direction of fluid flow from horizontal, α. The experiments were performed for seven different tube inclinations, α, in a range of − 90° to + 90° and four mass velocities of 46, 81, 110 and 136 kg m 2 s 1 for each tube inclination angle during evaporation of R-134a. Data analysis demonstrate that the tube inclination angle, α, affects the boiling heat transfer coefficient in a significant manner. The effect of tube inclination angle, α, on heat transfer coefficient, h, is more prominent at low vapor quality and mass velocity. In the low vapor quality region, the heat transfer coefficient, h, for the + 90° inclined tube is about 62% more than that of the − 90° inclined tube. The results also showed that at all mass velocities, the highest average heat transfer coefficient were achieved for α = + 90°. An empirical correlation has also been developed to predict the heat transfer coefficient during flow boiling inside a corrugated tube with different tube inclinations.  相似文献   

19.
The flow and heat transfer characteristics of an isolated square cylinder in crossflow placed symmetrically in a planar slit have been investigated for the range of conditions as 1  Re  45, 0.7  Pr  4000 (Pe  4000) and β = 1/8, 1/6 and 1/4. Heat transfer correlations have been obtained in the steady flow regime for the constant temperature and constant heat flux boundary conditions on the solid square cylinder in crossflow. In addition, variation of the local Nusselt number on each face of the obstacle and representative isotherm plots are presented to elucidate the role of Prandtl number and blockage ratio on drag coefficient and heat transfer.  相似文献   

20.
The paper gives the basic results of experimental investigation of hydrodynamics and heat transfer in heat-absorbing devices of the ITER thermonuclear reactor, which are subjected to one-side heating. The entire array of experimental data is obtained in the following range of parameters of water flow: pressure p = 0.7–2.0 MPa, mass flux G = 340–25,000 kg/(m2 s), inlet water temperature Tin = 15–60 °C. The experiments are performed with turbulent swirl flows of water for twisted tapes with the flow swirl coefficient k = 0.90, 0.66, 0.49, 0.39, 0.25, 0.19, and 0, as well for test sections without a tape. Given in the first part of the paper are the data on pressure drop and single-phase convective heat transfer. Appropriate calculation formulas are derived, which reliably generalize the experimental data.  相似文献   