首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Laser-induced breakdown spectroscopy (LIBS) is a promising technique for real-time chemical and biological warfare agent detection in the field. We have demonstrated the detection and discrimination of the biological warfare agent surrogates Bacillus subtilis (BG) (2% false negatives, 0% false positives) and ovalbumin (0% false negatives, 1% false positives) at 20 meters using standoff laser-induced breakdown spectroscopy (ST-LIBS) and linear correlation. Unknown interferent samples (not included in the model), samples on different substrates, and mixtures of BG and Arizona road dust have been classified with reasonable success using partial least squares discriminant analysis (PLS-DA). A few of the samples tested such as the soot (not included in the model) and the 25% BG:75% dust mixture resulted in a significant number of false positives or false negatives, respectively. Our preliminary results indicate that while LIBS is able to discriminate biomaterials with similar elemental compositions at standoff distances based on differences in key intensity ratios, further work is needed to reduce the number of false positives/negatives by refining the PLS-DA model to include a sufficient range of material classes and carefully selecting a detection threshold. In addition, we have demonstrated that LIBS can distinguish five different organophosphate nerve agent simulants at 20 meters, despite their similar stoichiometric formulas. Finally, a combined PLS-DA model for chemical, biological, and explosives detection using a single ST-LIBS sensor has been developed in order to demonstrate the potential of standoff LIBS for universal hazardous materials detection.  相似文献   

2.
The detection and identification of individual bioaerosols using laser-induced breakdown spectroscopy (LIBS) is investigated using aerosolized Bacillus spores. Spores of Bacillus atrophaeous, Bacillus pumilus, and Bacillus stearothemophilus were introduced into an aerosol flow stream in a prescribed manner such that single-particle LIBS detection was realized. Bacillus spores were successfully detected based on the presence of the 393.4- and 396.9-nm calcium atomic emission lines. Statistical analyses based on the aerosol number density, the LIBS-based spore sampling frequency, and the distribution of the resulting calcium mass loadings support the conclusion of individual spore detection within single-shot laser-induced plasmas. The average mass loadings were in the range of 2-3 fg of calcium/Bacillus spore, which corresponds to a calcium mass percentage of approximately 0.5%. While individual spores were detected based on calcium emission, the resulting Bacillus spectra were free from CN emission bands, which has implications for the detection of elemental carbon, and LIBS-based detection of single spores based on the presence of magnesium or sodium atomic emission was unsuccessful. Based on the current instrumental setup and analyses, real-time LIBS-based detection and identification of single Bacillus spores in ambient (i.e., real life) conditions appears unfeasible.  相似文献   

3.
Laser-induced breakdown spectroscopy (LIBS) is examined as a potential method for detecting airborne biological agents. A spectrally broadband LIBS system was used for laboratory measurements on some common biological agent simulants. These measurements were compared to those of common, naturally occurring biological aerosol components (pollen and fungal spores) to determine the potential of LIBS for discriminating biological agents from natural background aerosols. A principal components analysis illustrates that linear combinations of the detected atomic lines, which are present in different ratios in each of the samples tested, can be used to discriminate biological agent simulants from other biological matter. A more sensitive, narrowband LIBS instrument was used to demonstrate the detection of single simulant (Bg) particles in the size range 1-5 microns. Ca, Mg, and Na, which are present in varying concentrations between 0.3 and 11% (by mass) in the Bg particles, were observed in single particles using LIBS.  相似文献   

4.
Actual or surrogate chemical, biological, radiological, nuclear, and explosive materials and illicit drug precursors can be rapidly detected and identified when in aerosol form by a Single-Particle Aerosol Mass Spectrometry (SPAMS) system. This entails not only the sampling of such particles but also the physical analysis and subsequent data analysis leading to a highly reliable alarm state. SPAMS hardware is briefly reviewed. SPAMS software algorithms are discussed in greater detail. A laboratory experiment involving actual threat and surrogate releases mixed with ambient background aerosols demonstrates broad-spectrum detection within seconds. Data from a field test at the San Francisco International Airport demonstrate extended field operation with an ultralow false alarm rate. Together these data sets demonstrate a significant and important advance in rapid aerosol threat detection.  相似文献   

5.
Analysis of the dispersion of malignant anthrax spores in a 50-story tower block after a terrorist act has been carried out. A computer model of the aerosol dispersion in the case of intensive small-scale convection equalizing the concentration of malignant anthrax spores in separate rooms of the building has been developed. The model permits predicting the time interval needed for the spores to disperse. It has been shown that the release of even a relatively small amount of malignant anthrax spores can lead to a dangerous contamination of the whole building.Translated from Inzhenerno-Fizicheskii Zhurnal, Vol. 77, No. 6, pp. 79–89, November–December, 2004.  相似文献   

6.
A statistical analysis of ambient air particle monitoring, namely PM2.5, is presented to elucidate the correlations between laser-induced breakdown spectroscopy (LIBS)-based speciated aerosol monitoring and non-speciated aerosol monitoring (i.e., total particle counts). LIBS was used in a real-time, conditional-processing mode to identify individual aerosol particles containing detectable quantities of either calcium or sodium, as based on the resulting atomic emission signals. Using this technique, real-time measurements of speciated aerosol particle concentrations and analyte mass concentrations were evaluated for a total of 60 1-hour sampling periods spread over a 5-week period. For each 1-hour sampling period, total aerosol counts were simultaneously monitored using a commercial light scattering-based instrument. Over the 30 sampling periods, aerosol counts (both total and LIBS-based) were found to vary by more than one order of magnitude. For aerosol particles in the 500 nm to 2.5 microm size range, significant correlations were found between the two sampling methods, resulting in correlation coefficients (r2) ranging from 0.22 to 0.93. In addition, transient fluctuations in aerosol counts on a timescale of 5 to 10 minutes were successfully observed simultaneously with the two monitoring techniques, thereby demonstrating the temporal resolution of LIBS.  相似文献   

7.
为了研究碳气溶胶,包括有机碳与元素碳对陶质文物的表面腐蚀、彩绘脱失的影响,本文中于国庆黄金周期间(10月1~14日)对兵马俑博物馆一号坑(PitNo.1)和馆外(Outdoor)进行连续两周采集的碳气溶胶进行有机碳、元素碳组分的分析。结果表明:国庆黄金周期间(10月1~7日)馆内碳气溶胶明显高于馆外,有机碳与元素碳分别为馆外的2.3与1.6倍,馆内碳气溶胶占气溶胶组分的42.1%,表明受到大量游客的影响;10月8~14日期间馆内碳气溶胶略低于馆外,且与馆外浓度变化一致。  相似文献   

8.
The application of finite mixture regression models has recently gained an interest from highway safety researchers because of its considerable potential for addressing unobserved heterogeneity. Finite mixture models assume that the observations of a sample arise from two or more unobserved components with unknown proportions. Both fixed and varying weight parameter models have been shown to be useful for explaining the heterogeneity and the nature of the dispersion in crash data. Given the superior performance of the finite mixture model, this study, using observed and simulated data, investigated the relative performance of the finite mixture model and the traditional negative binomial (NB) model in terms of hotspot identification. For the observed data, rural multilane segment crash data for divided highways in California and Texas were used. The results showed that the difference measured by the percentage deviation in ranking orders was relatively small for this dataset. Nevertheless, the ranking results from the finite mixture model were considered more reliable than the NB model because of the better model specification. This finding was also supported by the simulation study which produced a high number of false positives and negatives when a mis-specified model was used for hotspot identification. Regarding an optimal threshold value for identifying hotspots, another simulation analysis indicated that there is a discrepancy between false discovery (increasing) and false negative rates (decreasing). Since the costs associated with false positives and false negatives are different, it is suggested that the selected optimal threshold value should be decided by considering the trade-offs between these two costs so that unnecessary expenses are minimized.  相似文献   

9.
The feasibility of using a novel detection scheme for the analysis of biological warfare agents is demonstrated using Bacillus globigii spores, a surrogate species for Bacillus anthracis. In this paper, a sensitive and selective enzyme-linked immunosorbent assay using a novel fluorogenic alkaline phosphatase substrate (dimethylacridinone phosphate) is combined with a compact biochip detection system, which includes a miniature diode laser for excitation. Detection of aerosolized spores was achieved by coupling the miniature system to a portable bioaerosol sampler, and the performance of the antibody-based recognition and enzyme amplification method was evaluated. The bioassay performance was found to be compatible with the air sampling device, and the enzymatic amplification was found to be an attractive amplification method for detection of low spore concentrations. The combined portable bioaerosol sampler and miniature biochip system detected 100 B. globigii spores, corresponding to 17 aerosolized spores/L of air. Moreover, the incorporation of the miniature diode laser with the self-contained biochip design allows for a compact system that is readily adaptable to field use. In addition, these studies have included investigations into the tradeoff between assay time and sensitivity.  相似文献   

10.
The rapid chemical analysis of individual cells is an analytical capability that will profoundly impact many fields including bioaerosol detection for biodefense and cellular diagnostics for clinical medicine. This article describes a mass spectrometry-based analytical technique for the real-time and reagentless characterization of individual airborne cells without sample preparation. We characterize the mass spectral signature of individual Bacillus spores and demonstrate the ability to distinguish two Bacillus spore species, B. thuringiensis and B.atrophaeus, from one another very accurately and from the other biological and nonbiological background materials tested with no false positives at a sensitivity of 92%. This example demonstrates that the chemical differences between these two Bacillus spore species are consistently and easily detected within single cells in seconds.  相似文献   

11.
Most laser-based aerosol mass spectrometers rely on a single ultraviolet laser to both ablate and ionize the aerosol particle. This technique produces complex and fragmented mass spectra, especially for organic compounds. The approach presented here achieves a more robust and quantitative analysis using a CO2 laser to evaporate the aerosol particle and a vacuum ultraviolet laser to ionize the vapor plume. Vacuum ultraviolet laser ionization produces little fragmentation in the mass spectra, making the identification of an aerosol particle's constituents more straightforward. An analysis of simple, three-component mixtures of aniline, benzyl alcohol, and m-nitrotoluene shows that the technique also provides a quantitative analysis for all the components of the mixture. Furthermore, the detection of predominantly parent ion signal from anthracene particles demonstrates the utility of the technique in the analysis of lower vapor pressure, solid-phase aerosols. Finally, we discuss the potential and limitations of this technique in analyzing organic atmospheric aerosols.  相似文献   

12.
Laser-induced breakdown spectroscopy (LIBS) measurements of alkali in the high-temperature exhaust of a glass furnace show an attenuation of the Na and K LIBS signals that correlates with the stoichiometry of the bath gas surrounding the spark. The results are explained as being due to (1) a strong increase in the concentration of atomic Na and K, resulting in neutral line signal absorption by these atoms, and to (2) a change of phase of the major Na- and K-containing species from an aerosol to a gaseous phase when the gas mixture becomes fuel rich, resulting in a reduced LIBS emission intensity. LIBS sampling at lower temperatures, or in a consistently oxidizing environment, or both are suggested strategies for circumventing these difficulties.  相似文献   

13.
Based on the filter-sampled chemical composition data the seasonal variation of the optical properties of polydispersed aerosols, extinction, scattering, and absorption coefficient, are estimated for various types of aerosol mixtures. The mixtures considered in this study are the internal mixture, elemental carbon (EC)/non-EC external mixture, and fully external mixture. This study also evaluated the sensitivity of the aerosol optical properties for different size distributions. The results show that the extinction coefficient can be mostly accounted for scattering and generally shows a good agreement with each mixture type in this case study. However, the absorption coefficient shows a different tendency for internal and external mixtures. This study also shows that the aerosol optical properties vary as a function of particle diameter at the same composition and mass concentration. This means that mass extinction, scattering, and absorption efficiencies, which were considered as constants in general, should be reassessed and more specifically described as a function of particle size.  相似文献   

14.
We report the design and operation of a prototype conditional-sampling spectrograph detection system that can record the fluorescence spectra of individual, micrometer-sized aerosols as they traverse an intense 488-nm intracavity laser beam. The instrument's image-intensified CCD detector is gated by elastic scattering or by undispersed fluorescence from particles that enter the spectrograph's field of view. It records spectra only from particles with preselected scattering-fluorescence levels (a fiber-optic-photomultiplier subsystem provides the gating signal). This conditional-sampling procedure reduces data-handling rates and increases the signal-to-noise ratio by restricting the system's exposures to brief periods when aerosols traverse the beam. We demonstrate these advantages by reliably capturing spectra from individual fluorescent microspheres dispersed in an airstream. The conditional-sampling procedure also permits some discrimination among different types of particles, so that spectra may be recorded from the few interesting particles present in a cloud of background aerosol. We demonstrate such discrimination by measuring spectra from selected fluorescent microspheres in a mixture of two types of microspheres, and from bacterial spores in a mixture of spores and nonfluorescent kaolin particles.  相似文献   

15.
A series of laboratory experiments have been performed highlighting the potential of laser-induced breakdown spectroscopy (LIBS) as a versatile sensor for the detection of terrorist threats. LIBS has multiple attributes that provide the promise of unprecedented performance for hazardous material detection and identification. These include: 1) real-time analysis, 2) high sensitivity, 3) no sample preparation, and 4) the ability to detect all elements and virtually all hazards, both molecular and biological. We have used LIBS to interrogate a variety of different target samples, including explosives, chemical warfare simulants, biological agent simulants, and landmine casings. We have used the acquired spectra to demonstrate discrimination between different chemical warfare simulants, including those on soil backgrounds. A linear correlation technique permits discrimination between an anthrax surrogate and several other biomaterials such as molds and pollens. We also use broadband LIBS to identify landmine casings versus other plastics and environmental clutter materials. A new man-portable LIBS system developed as a collaborative effort between the U.S. Army Research Laboratory and Ocean Optics, Inc., is described and several other schemes for implementing LIBS sensors for homeland security and force protection are discussed.  相似文献   

16.
The 96-well plate format of enzyme-linked immunosorbent assay (ELISA) is the de facto standard in screening hybridomas for active antibody. Despite its widespread use, there have been few or no systematic attempts to validate its accuracy and answer the fundamental question, is it finding all the positives? We report here on a comparison between ELISA and a semiautomated flow-based kinetic exclusion assay (KinExA), both used in screening the same hybridoma cell line. Our finding is that ELISA is both overreporting (false positives) and underreporting (false negatives) compared to the KinExA system. The large number of hybridoma cells (e.g., cultured in six 96-well plates) that must be checked is daunting in considering any method other than ELISA for routine screening. To overcome this, we devised a sampling strategy in which wells are combined in a specified pattern, allowing a significant reduction in the total number of measurements required.  相似文献   

17.
For domestic and military security, an autonomous system capable of continuously monitoring for airborne biothreat agents is necessary. At present, no system meets the requirements for size, speed, sensitivity, and selectivity to warn against and lead to the prevention of infection in field settings. We present a fully automated system for the detection of aerosolized bacterial biothreat agents such as Bacillus subtilis (surrogate for Bacillus anthracis) based on protein profiling by chip gel electrophoresis coupled with a microfluidic sample preparation system. Protein profiling has previously been demonstrated to differentiate between bacterial organisms. With the goal of reducing response time, multiple microfluidic component modules, including aerosol collection via a commercially available collector, concentration, thermochemical lysis, size exclusion chromatography, fluorescent labeling, and chip gel electrophoresis were integrated together to create an autonomous collection/sample preparation/analysis system. The cycle time for sample preparation was approximately 5 min, while total cycle time, including chip gel electrophoresis, was approximately 10 min. Sensitivity of the coupled system for the detection of B. subtilis spores was 16 agent-containing particles per liter of air, based on samples that were prepared to simulate those collected by wetted cyclone aerosol collector of approximately 80% efficiency operating for 7 min.  相似文献   

18.
Experimental evaluation of hotspot identification methods   总被引:1,自引:0,他引:1  
Identifying crash "hotspots", "blackspots", "sites with promise", or "high risk" locations is standard practice in departments of transportation throughout the US. The literature is replete with the development and discussion of statistical methods for hotspot identification (HSID). Theoretical derivations and empirical studies have been used to weigh the benefits of various HSID methods; however, a small number of studies have used controlled experiments to systematically assess various methods. Using experimentally derived simulated data--which are argued to be superior to empirical data, three hot spot identification methods observed in practice are evaluated: simple ranking, confidence interval, and Empirical Bayes. Using simulated data, sites with promise are known a priori, in contrast to empirical data where high risk sites are not known for certain. To conduct the evaluation, properties of observed crash data are used to generate simulated crash frequency distributions at hypothetical sites. A variety of factors is manipulated to simulate a host of 'real world' conditions. Various levels of confidence are explored, and false positives (identifying a safe site as high risk) and false negatives (identifying a high risk site as safe) are compared across methods. Finally, the effects of crash history duration in the three HSID approaches are assessed. The results illustrate that the Empirical Bayes technique significantly outperforms ranking and confidence interval techniques (with certain caveats). As found by others, false positives and negatives are inversely related. Three years of crash history appears, in general, to provide an appropriate crash history duration.  相似文献   

19.
Shimota A  Kobayashi H 《Applied optics》2001,40(9):1493-1500
The possibility of retrieval of urban aerosol physical properties from downwelling atmospheric infrared radiation spectra between 700 and 1400 cm(-1) with 0.24-cm(-1) spectral resolution, which can be obtained from the tropospheric infrared interferometric sounder developed by the Central Research Institute of Electric Power Industry, was estimated from error analysis of the least-squares fit method. The error analysis for retrieval of the aerosol extinction coefficient spectra in three atmospheric layers (boundary, free troposphere, and stratosphere) showed the retrievability only of the boundary layer. Based on this result, we propose the retrieval for particle number density of each aerosol component, which is one of the parameters for the aerosol size distribution function, using the boundary aerosol extinction coefficient spectra. We assume that aerosols in urban areas consist of three types of component, namely, water soluble, soot, and dustlike. Under this assumption, we estimated the error of the retrieved volume density for each aerosol component. For the estimation we used the least-squares fit of Mie-generated spectral extinction coefficients. The estimated error shows that the volume density of each aerosol component in an urban boundary layer is equivalent to the retrieval target. We also show that the aerosol properties can be retrieved with higher accuracy when the effects of multiple scattering by aerosols are included in the retrieval procedure.  相似文献   

20.
Laser induced breakdown spectroscopy (LIBS) is shown to be capable of low volume (90 pL) quantitative elemental analysis of picogram amounts of dissolved metals in solutions. Single-pulse and collinear double-pulse LIBS were investigated using a 532 nm dual head laser coupled to a spectrometer with an intensified charge coupled device (CCD) detector. Aerosols were produced using a micronebulizer, conditioned inside a concentric spray chamber, and released through an injector tube with a diameter of 1 mm such that a LIBS plasma could be formed ~2 mm from the exit of the tube. The emissions from both the aerosols and a single microdrop were then collected with a broadband high resolution spectrometer. Multielement calibration solutions were prepared, and continuing calibration verification (CCV) standards were analyzed for both aerosol and microdrop systems to calculate the precision, accuracy, and limits of detection for each system. The calibration curves produced correlation coefficients with R(2) values > 0.99 for both systems. The precision, accuracy, and limit of detection (LOD) determined for aerosol LIBS were averaged and determined for the emission lines of Sr II (421.55 nm), Mg II (279.80 nm), Ba II (493.41 nm), and Ca II (396.84 nm) to be ~3.8% RSD, 3.1% bias, 0.7 μg/mL, respectively. A microdrop dispenser was used to deliver single drops containing 90 pL into the space where a LIBS plasma was generated with a focused laser pulse. In the single drop microdrop LIBS experiment, the analysis of a single drop, containing a total mass of 45 pg, resulted in a precision of 13% RSD and a bias of 1% for the Al I (394.40 nm) emission line. The absolute limits of detection of single drop microdrop LIBS for the emission lines Al I (394.40 nm) and Sr II (421.5 nm) were approximately 1 pg, and Ba II (493.41 nm) produced an absolute detection limit of approximately 3 pg. Overall, the precision, accuracy, and absolute LOD determined for single microdrop LIBS resulted in a typical performance of ~14% RSD, 6% bias, and 1 pg for the elements Sr II (421.55 nm), Al I(394.40 nm), Mg II (279.80), and Ba II(493.41 nm).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号