首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
We have fabricated a flow-through biochip assembly that consisted of two different microchips: (1) a polycarbonate (PC) chip for performing an allele-specific ligation detection reaction (LDR) and (2) a poly(methyl methacrylate) (PMMA) chip for the detection of the LDR products using an universal array platform. The operation of the device was demonstrated by detecting low-abundant DNA mutations in gene fragments (K-ras) that carry point mutations with high diagnostic value for colorectal cancers. The PC microchip was used for the LDR in a continuous-flow format, in which two primers (discriminating primer that carried the complement base to the mutation being interrogated and a common primer) that flanked the point mutation and were ligated only when the particular mutation was present in the genomic DNA. The miniaturized reactor architecture allowed enhanced reaction speed due to its high surface-to-volume ratio and efficient thermal management capabilities. A PMMA chip was employed as the microarray device, where zip code sequences (24-mers), which were complementary to sequences present on the target, were microprinted into fluidic channels embossed into the PMMA substrate. Microfluidic addressing of the array reduced the hybridization time significantly through enhanced mass transport to the surface-tethered zip code probes. The two microchips were assembled as a single integrated unit with a novel interconnect concept to produce the flow-through microfluidic biochip. A microgasket, fabricated from an elastomer poly(dimethylsiloxane) with a total volume of the interconnecting assembly of <200 nL, was used as the interconnect between the two chips to produce the three-dimensional microfluidic network. We successfully demonstrated the ability to detect one mutant DNA in 100 normal sequences with the biochip assembly. The LDR/hybridization assay using the assembly performed the entire assay at a relatively fast processing speed: 6.5 min for on-chip LDR, 10 min for washing, and 2.6 min for fluorescence scanning (total processing time 19.1 min) and could screen multiple mutations simultaneously.  相似文献   

2.
Koh CG  Tan W  Zhao MQ  Ricco AJ  Fan ZH 《Analytical chemistry》2003,75(17):4591-4598
An integrated plastic microfluidic device was designed and fabricated for bacterial detection and identification. The device, made from poly(cyclic olefin) with integrated graphite ink electrodes and photopatterned gel domains, accomplishes DNA amplification, microfluidic valving, sample injection, on-column labeling, and separation. Polymerase chain reaction (PCR) is conducted in a channel reactor containing a volume as small as 29 nL; thermal cycling utilizes screen-printed graphite ink resistors. In situ gel polymerization was employed to form local microfluidic valves that minimize convective flow of the PCR mixture into other regions. After PCR, amplicons (products) are electrokinetically injected through the gel valve, followed by on-chip electrophoretic separation. An intercalating dye is admixed to label the amplicons; they are detected using laser-induced fluorescence. Two model bacteria, Escherichia coli O157 and Salmonella typhimurium, were chosen to demonstrate bacterial detection and identification based on amplification of several of their unique DNA sequences. The limit of detection is about six copies of target DNA.  相似文献   

3.
Here, we report the fabrication of a chemical gradient microfluidic device for single-cell cytotoxicity assays. This device consists of a microfluidic chemical gradient generator and a microcavity array that enables entrapment of cells with high efficiency at 88 ± 6% of the loaded cells. A 2-fold logarithmic chemical gradient generator that is capable of generating a serial 2-fold gradient was designed and then integrated with the microcavity array. High density single-cell entrapment was demonstrated in the device without cell damage, which was performed in 30 s. Finally, we validated the feasibility of this device to perform cytotoxicity assays by exposing cells to potassium cyanide (0-100 μM KCN). The device captured images of 4000 single cells affected by 6 concentrations of KCN and determined cell viability by counting the effected cells. Image scanning of the microcavity array was completed within 10 min using a 10× objective lens and a motorized stage. Aligning cells on the microcavity array eases cell counting, observation, imaging, and evaluation of singular cells. Thus, this platform was able to determine the cytotoxicity of chemicals at a single-cell level, as well as trace the cytotoxicity over time. This device and method will be useful for cytotoxicity analysis and basic biomedical research.  相似文献   

4.
Bowden M  Song L  Walt DR 《Analytical chemistry》2005,77(17):5583-5588
In this paper, DNA hybridization in a microfluidic manifold is performed using fluorescence detection on a fiber-optic microarray. The microfluidic device integrates optics, sample transport, and fluidic interconnects on a single platform. A high-density optical imaging fiber array containing oligonucleotide-labeled microspheres was developed. DNA hybridization was observed at concentrations as low as 10 aM with response times of less than 15 min at a flow rate of 1 microL/min using 50 microL of target DNA samples. The fast response times coupled with the low sample volumes and the use of a high-density, fiber-optic microarray format make this method highly advantageous. This paper describes the initial development, optimization, and integration of the microfluidic platform with imaging fiber arrays.  相似文献   

5.
On-chip surface-based detection with nanohole arrays   总被引:3,自引:0,他引:3  
A microfluidic device with integrated surface plasmon resonance (SPR) chemical and biological sensors based on arrays of nanoholes in gold films is demonstrated. Widespread use of SPR for surface analysis in laboratories has not translated to microfluidic analytical chip platforms, in part due to challenges associated with scaling down the optics and the surface area required for common reflection mode operation. The resonant enhancement of light transmission through subwavelength apertures in a metallic film suggests the use of nanohole arrays as miniaturized SPR-based sensing elements. The device presented here takes advantage of the unique properties of nanohole arrays: surface-based sensitivity; transmission mode operation; a relatively small footprint; and repeatability. Proof-of-concept measurements performed on-chip indicated a response to small changes in refractive index at the array surfaces. A sensitivity of 333 nm per refractive index unit was demonstrated with the integrated device. The device was also applied to detect spatial microfluidic concentration gradients and to monitor a biochemical affinity process involving the biotin-streptavidin system. Results indicate the efficacy of nanohole arrays as surface plasmon-based sensing elements in a microfluidic platform, adding unique surface-sensitive diagnostic capabilities to the existing suite of microfluidic-based analytical tools.  相似文献   

6.
A 16-channel microfluidic chip with an integrated contact conductivity sensor array is presented. The microfluidic network consisted of 16 separation channels that were hot-embossed into polycarbonate (PC) using a high-precision micromilled metal master. All channels were 40 microm deep and 60 microm wide with an effective separation length of 40 mm. A gold (Au) sensor array was lithographically patterned onto a PC cover plate and assembled to the fluidic chip via thermal bonding in such a way that a pair of Au microelectrodes (60 microm wide with a 5 microm spacing) was incorporated into each of the 16 channels and served as independent contact conductivity detectors. The spacing between the corresponding fluidic reservoirs for each separation channel was set to 9 mm, which allowed for loading samples and buffers to all 40 reservoirs situated on the microchip in only five pipetting steps using an 8-channel pipettor. A printed circuit board (PCB) with platinum (Pt) wires was used to distribute the electrophoresis high-voltage to all reservoirs situated on the fluidic chip. Another PCB was used for collecting the conductivity signals from the patterned Au microelectrodes. The device performance was evaluated using microchip capillary zone electrophoresis (mu-CZE) of amino acid, peptide, and protein mixtures as well as oligonucleotides that were separated via microchip capillary electrochromatography (mu-CEC). The separations were performed with an electric field (E) of 90 V/cm and were completed in less than 4 min in all cases. The conductivity detection was carried out using a bipolar pulse voltage waveform with a pulse amplitude of +/-0.6 V and a frequency of 6.0 kHz. The conductivity sensor array concentration limit of detection (SNR = 3) was determined to be 7.1 microM for alanine. The separation efficiency was found to be 6.4 x 10(4), 2.0 x 10(3), 4.8 x 10(3), and 3.4 x 10(2) plates for the mu-CEC of the oligonucleotides and mu-CZE of the amino acids, peptides, and proteins, respectively, with an average channel-to-channel migration time reproducibility of 2.8%. The average resolution obtained for mu-CEC of the oligonucleotides and mu-CZE of the amino acids, peptides, and proteins was 4.6, 1.0, 0.9, and 1.0, respectively. To the best of our knowledge, this report is the first to describe a multichannel microchip electrophoresis device with integrated contact conductivity sensor array.  相似文献   

7.
Mao H  Holden MA  You M  Cremer PS 《Analytical chemistry》2002,74(19):5071-5075
This paper describes a reusable platform that can apply a linear temperature gradient to a lab-on-a-chip device. When a planar microfluidic device with a series of microchannels is placed on top of the platform with the channels perpendicular to the gradient, each channel is held at a discrete temperature. This allows temperature-dependent data for chemical or biochemical species flowed into the device to be obtained in a concurrent fashion. As a demonstration, a melting curve for dsDNA is performed by collecting all the data simultaneously. The gradient is stable enough to easily distinguish between 30-mers where the complement strand contains a single C-A mismatch or a single T-G mismatch or is a perfect match. On the other hand, a temperature gradient can be formed parallel to the direction of flow of the microchannels. This allows the temperature in each channel to vary continuously as the liquid flows downstream. If each microchannel in the array contains a distinct pH value, ionic strength, species concentration, or chemical composition, then a high-throughput two-variable experiment can be performed. We demonstrate this mode of data collection by measuring the fluorescence yield of fluorescein dye molecules in aqueous solution simultaneously as a function of concentration and temperature.  相似文献   

8.
Electrochemical techniques based on ultramicroelectrodes (UMEs) play a significant role in real-time monitoring of chemical messengers' release from single cells. Conversely, precise monitoring of cells in vitro strongly depends on the adequate construction of cellular physiological microenvironment. In this paper, we developed a multilayer microdevice which integrated high aspect ratio poly(dimethylsiloxane) (PDMS) microfluidic device for long-term automated perfusion culture of cells without shear stress and an independently addressable microelectrodes array (IAMEA) for electrochemical monitoring of the cultured cells in real time. Novel design using high aspect ratio between circular "moat" and ring-shaped micropillar array surrounding cell culture chamber combined with automated "circular-centre" and "bottom-up" perfusion model successfully provided continuous fresh medium and a stable and uniform microenvironment for cells. Two weeks automated culture of human umbilical endothelial cell line (ECV304) and neuronal differentiation of rat pheochromocytoma (PC12) cells have been realized using this device. Furthermore, the quantal release of dopamine from individual PC12 cells during their culture or propagation process was amperometrically monitored in real time. The multifunctional microdevice developed in this paper integrated cellular microenvironment construction and real-time monitoring of cells during their physiological process, and would possibly provide a versatile platform for cell-based biomedical analysis.  相似文献   

9.
Dynamic DNA hybridization on a chip using paramagnetic beads   总被引:7,自引:0,他引:7  
Dynamic DNA hybridization is presented as an approach to perform gene expression analysis. The method is advantageous because of its dynamic supplies of both DNA samples and probes. The approach was demonstrated on a microfluidic platform by incorporating paramagnetic beads as a transportable solid support. A glass chip was fabricated to allow simultaneous interrogation of eight DNA target samples by DNA probes. DNA targets were immobilized on beads via streptavidin-biotin conjugation or base pairing between oligonucleotide residues. The DNA/bead complex was introduced into the device in which hybridization took place with a complementary probe. The hybridized probe was then removed by heat denaturation to allow the DNA sample to be interrogated again by another probe with a different sequence of interest. A pneumatic pumping apparatus was constructed to transport DNA probes and other reagents into the microfluidic device while hydrostatic pumping was used for the introduction of paramagnetic beads with samples. After investigating three types of paramagnetic beads, we found Dynabeads Oligo(dT)25 best suited this application. Targets on the beads could be sequentially interrogated by probes for 12 times, and the hybridization signal was maintained within experimental variation. Demonstration of specific hybridization reactions in an array format was achieved using four synthesized DNA targets in duplicate and five probes in sequence, indicating the potential application of this approach to gene expression analysis.  相似文献   

10.
This work describes an integrated microfluidic (mu-fl) device that can be used to effect separations that discriminate single-nucleotide polymorphisms (SNP) based on kinetic differences in the lability of perfectly matched (PM) and mismatched (MM) DNA duplexes during alkaline dehybridization. For this purpose a 21-base single-stranded DNA (ssDNA) probe sequence was immobilized on agarose-coated magnetic beads, that in turn can be localized within the channels of a poly(dimethylsiloxane) microfluidic device using an embedded magnetic separator. The PM and MM ssDNA targets were hybridized with the probe to form a mixture of PM and MM DNA duplexes using standard protocols, and the hydroxide ions necessary for mediating the dehybridization were generated electrochemically in situ by performing the oxygen reduction reaction (ORR) using O2 that passively permeates the device at a Pt working electrode (Pt-WE) embedded within the microfluidic channel system. The alkaline DNA dehybridization process was followed using fluorescence microscopy. The results of this study show that the two duplexes exhibit different kinetics of dehybridization, rate profiles that can be manipulated as a function of both the amount of the hydroxide ions generated and the mass-transfer characteristics of their transport within the device. This system is shown to function as a durable platform for effecting hybridization/dehybridization cycles using a nonthermal, electrochemical actuation mechanism, one that may enable new designs for lab-on-a-chip devices used in DNA analysis.  相似文献   

11.
12.
Rapid detection and identification of influenza virus is becoming increasingly important in the face of concerns over an influenza pandemic. A fully integrated and self-contained microfluidic device has been developed to rapidly identify influenza A hemagglutinin and neuraminidase subtypes and sequence portions of both genes. The device consists of a DNA microarray with 12 000 features and a microfluidic cartridge that automates the fluidic handling steps required to carry out a genotyping assay for pathogen identification and sequencing. The fully integrated microfluidic device consists of microfluidic pumps, mixers, valves, fluid channels, reagent storage chambers, and DNA microarray silicon chip. Microarray hybridization and subsequent fluidic handling and reactions were performed in this fully automated and miniature device before fluorescent image scanning of the microarray chip. A micromixing technique based on gas bubbling generated by electrochemical micropumps was developed. Low-cost check valves were implemented in the cartridge to prevent cross talk of the stored reagents. The genotyping results showed that the device identified influenza A hemagglutinin and neuraminidase subtypes and sequenced portions of both genes, demonstrating the potential of integrated microfluidic and microarray technology for multiple virus detection. The device provides a cost-effective solution to eliminate labor-intensive and time-consuming fluidic handling steps and allows the detection and identification of influenza virus in a rapid and automated fashion.  相似文献   

13.
14.
High-efficiency mixing is of fundamental importance for the successful development and application of lab-on-a-chip devices. In this report, we present the use of bioinspired thermally triggered liposomes for the controlled delivery and subsequent rapid mixing of reagents in a microfluidic device. In this technique, reagents are encapsulated inside the aqueous interior of liposomes that are dispersed evenly throughout a microfluidic system. Mixing of the encapsulated reagent and reaction do not occur until the reagent is released by a thermal trigger. This approach takes advantage of the dramatically increased lipid membrane permeability of liposomes near the gel-to-liquid phase transition temperature (T(m)) to deliver reagents at a precise location in the microfluidic device through the modulation of temperature. Implementation of this technique requires the encapsulation of the desired reagent in a liposome whose formulation has an appropriate T(m), as well as accurate spatial control of the temperature in the microfluidic device. As the liposomes are uniformly dispersed through the microfluidic channel, mixing occurs quite rapidly upon the release of the reagent. We demonstrate this technique by using several formulations of thermally triggered liposomes to release the hydrophilic fluorescent dyes at controlled locations in a polycarbonate microfluidic device. Additionally, we demonstrate a DNA labeling reaction using liposomes in a capillary-based microfluidic device. Under the conditions studied here, mixing and reaction are complete in approximately 200 microm of channel length. We believe this approach holds great promise for the performance of rapid high-throughput assays and in particular for biological analytes whose native environment is mimicked by the liposome.  相似文献   

15.
Ultrasonic particle manipulation tools have many promising applications in life sciences, expanding on the capabilities of current manipulation technologies. In this paper, the ultrasonic manipulation of particles and cells along a microfluidic channel with a piezoelectric array is demonstrated. An array integrated into a planar multilayer resonator structure drives particles toward the pressure nodal plane along the centerline of the channel, then toward the acoustic velocity maximum centered above the subset of elements that are active. Switching the active elements along the array moves trapped particles along the microfluidic channel. A 12-element 1-D array coupled to a rectangular capillary has been modeled and fabricated for experimental testing. The device has a 300-μm-thick channel for a half-wavelength resonance near 2.5 MHz, with 500 μm element pitch. Simulation and experiment confirm the expected trapping of particles at the center of the channel and above the set of active elements. Experiments demonstrated the feasibility of controlling the position of particles along the length of the channel by switching the active array elements.  相似文献   

16.
Wei H  Li H  Mao S  Lin JM 《Analytical chemistry》2011,83(24):9306-9313
A microfluidic device was integrated in a controlled coculture system, in which the secreted proteins were qualitatively and semiquantitatively determined by a directly coupled mass spectrometer. PC12 cells and GH3 cells were cocultured under various conditions as a model of the regulation of the organism by the nervous system. A micro-solid phase extraction (SPE) column was integrated in order to remove salts from the cells secretion prior to mass spectrometry detection. A three layer polydimethylsiloxane (PDMS) microfluidic device was fabricated to integrate valves for avoiding contamination between the cells coculture zone and the pretreatment zone. Electrospray ionization (ESI)-quadrupole (Q)-time of flight (TOF)-mass spectrometry was employed to realize highly sensitive qualitative analysis and to implement semiquantitative analysis. Furthermore, cell migrations under various coculture conditions were observed and discussed. The inhibition on growth hormone secretion from GH3 cells by dopamine released from PC12 cells was investigated and demonstrated. Thus, the developed platform provides a useful tool on cell to cell signaling studies for disease monitoring and drug delivery control.  相似文献   

17.
This work presents a simple microfluidic device with an integrated thin-film heater for studies of DNA hybridization kinetics and double-stranded DNA melting temperature measurements. The heating characteristics of the device were evaluated with a novel, noninvasive indirect technique using molecular beacons as temperature probes inside reaction chambers. This is the first microfluidic device in which thermal dehybridization of surface-bound oligonucleotides was performed for measurement of double-stranded DNA melting temperatures with +/- 1 degrees C precision. Surface modification and oligonucleotide immobilization were performed by continuously flowing reagents through the microchannels. The resulting reproducibility of oligonucleotide surface densities, at 9% RSD, was better than for the same modification chemistries on glass slides in unstirred reagent solutions (RSD=20%). Moreover, the surface density of immobilized DNA probe molecules could be varied controllably by changing the concentration of the reagent solution used for immobilization. Thus, excellent control of surface characteristics was made possible, something which is often difficult to achieve with larger devices. Solid-phase hybridization reactions, a fundamental aspect of microarray technologies often taking several hours in conventional systems, were reduced to minutes in this device. It was also possible to determine forward rate constants for hybridization, k. These varied from 820,000 to 72,000 M(-1) s(-1), decreasing as surface densities increased. Surface densities could therefore be optimized to obtain rapid hybridization using such an approach. Taken together, this combined microfluidic/small-volume heating approach represents a powerful tool for surface-based DNA analysis.  相似文献   

18.
We report a new, bioconjugate approach to performing highly multiplexed single-base extension (SBE) assays, which we demonstrate by genotyping a large panel of point mutants in exons 5-9 of the p53 gene. A series of monodisperse polyamide "drag-tags" was created using both chemical and biological synthesis and used to achieve the high-resolution separation of genotyping reaction products by microchannel electrophoresis without a polymeric sieving matrix. A highly multiplexed SBE reaction was performed in which 16 unique drag-tagged primers simultaneously probe 16 p53 gene loci, with an abbreviated thermal cycling protocol of only 9 min. The drag-tagged SBE products were rapidly separated by free-solution conjugate electrophoresis (FSCE) in both capillaries and microfluidic chips with genotyping accuracy in excess of 96%. The separation requires less than 70 s in a glass microfluidic chip, or about 20 min in a commercial capillary array sequencing instrument. Compared to gel electrophoresis, FSCE offers greater freedom in the design of SBE primers by essentially decoupling the length of the primer and the electrophoretic mobility of the genotyping products. FSCE also presents new possibilities for the facile implementation of SBE on integrated microfluidic electrophoresis devices for rapid, high-throughput genetic mutation detection or SNP scoring.  相似文献   

19.
An electrokinetic injection technique is described which uses a nuclear track-etched nanocapillary array to inject sample plugs from one layer of a microfluidic device into another vertically separated layer for electrophoretic separations. Gated injection protocols for analyte separations, reported here, establish nanocapillary array interconnects as a route to multilevel microfluidic analytical designs. The hybrid nanofluidic/microfluidic gated injection protocol allows sample preparation and separation to be implemented in separate horizontal planes, thereby achieving multilayer integration. Repeated injections and separations of FITC-labeled arginine and tryptophan, using 200-nm pore-diameter capillary array injectors in place of traditional cross injectors are used to demonstrate gated injection with a bias configuration that uses relay switching of a single high-voltage source. Injection times as rapid as 0.3 s along with separation reproducibilities as low as 1% for FITC-labeled arginine exemplify the capability for fast, serial separations and analyses. Impedance analysis of the micro-/nanofluidic network is used to gain further insight into the mechanism by which this actively controlled nanofluidic-interconnect injection method works. Gated sample introduction via a nanocapillary array interconnect allows the injection and separation protocols to be optimized independently, thus realizing the versatility needed for real-world implementation of rapid, serial microchip analyses.  相似文献   

20.
An independent, temperature-controllable microelectrode array   总被引:1,自引:0,他引:1  
Rapid, localized temperature control and negligible power consumption are key requisites for realizing effective parallel and sequential processing in the miniaturized, integrated biomedical microdevices where temperature-dependent biochemical reactions and fluid flow occur. In this study, an independent, temperature-controllable microelectrode array, with excellent temperature control rates and minimal power consumption, has been developed using microelectromechanical systems technology. The microfabricated array consists of Pt microelectrodes (100-microm diameter), with n-doped polysilicon microheaters (1.4-k Omega resistance), and vacuum-sealed cavities of depth 6.2 microm and diameter 200 microm. The thermal characteristics of each microelectrode were evaluated electrochemically through surface temperature measurements. The large heater power coefficient (2.1 +/- 0.1 degrees C mW(-1)) and the short heating and cooling times (less than 0.2 s for T(0.95)) are consequences of the vacuum-sealed cavities, which facilitate good thermal isolation and low thermal mass. The temperature of each microelectrode is independently controlled by a dedicated microheater, without thermally influencing the adjacent microelectrodes significantly.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号