首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Abstract Fungal spore content in dust accumulated in air ducts was investigated in 24 mechanically ventilated single-family houses of which 15 had also a central air heating system. Dust was collected from the ducts simultaneously with cleaning of the ventilation systems. Besides spore concentrations and flora of culturable fungi, total fungal spore concentrations were determined in dust samples by the aqueous two-phase technique and spore counting with epifluorescence microscopy. Culturable spore concentrations in the dust varied from 104 to 107 CFU/g and total spore concentrations from 107 to 108 spores/g. Total spore concentrations in the duct dust were significantly higher in the air heated houses than in the other mechanically ventilated houses. The difference resulted mainly from a higher proportion of recirculation air and a higher age of the air heated houses. Cladosporium, Penicillium, Aspergillus and yeasts consisted of >90% of fungal flora in the dust. Although total spore concentrations were at the same level both in the exhaust and in the supply ducts in both types of house, culturable fungal spore concentrations were slightly higher in the exhaust ducts than in the supply ducts. The proportion of culturable spores was <5% of total spores in dust accumulated in the ducts.  相似文献   

2.
Fungal exposure inside homes has been associated with adverse respiratory symptoms in children and adults. While fungal assessment has traditionally relied upon questionnaires, fungal growth on culture plates and spore counts, new immunoassays for extracellular polysaccharides (EPS) and beta (1-->3)-glucans have enabled quantitation of fungal agents in house dust in a more timely and cost-effective manner, possibly providing a better measure of fungal exposure. We investigated associations among measurements of EPS, beta (1-->3)-glucans and culturable fungi obtained from 23 Dutch homes. From each home, dust samples were vacuumed from the living room floor twice during the Fall, Winter and Spring seasons for a total of six collections (every 6 weeks from October 1997 to May 1998). Samples were sieved and fine dust was analyzed for EPS from Aspergillus and Penicillium spp. combined, beta (1-->3)-glucans and culturable fungi. EPS was positively associated with glucan; an increase from the 25th to the 75th percentile of glucan concentration was associated with a 1.6-fold increase in EPS concentration (95% CI = 1.3 to 2.0; p < 0.01). The most significant variables associated with EPS and glucan concentrations were the surface type that was vacuumed and the concentration of total culturable fungi (in colony forming units (CFU)/g dust), with an increase in CFU/g from the 25th to the 75th percentile associated with a 1.3 (1.1-1.6)-fold increase in glucan and a 1.7 (1.3-2.2)-fold increase in EPS concentrations. In addition, the within-home variation of EPS levels were smaller than those between homes (25,646 U/g vs. 50,635 U/g), whereas the variation of glucan levels was similar within and between homes (1,300 vs. 1,205 micrograms/g). These positive associations suggest that house dust concentrations of beta (1-->3)-glucan, and particularly those of EPS, are good markers for the overall levels of fungal concentrations in floor dust which is a surrogate for estimating airborne fungal exposure.  相似文献   

3.
This study investigated concentration and types of airborne fungi spores of indoor air. Forty nine houses of Santa Fe city (Argentina) were examined during one year. This city is characterized by a warm climate with an annual mean temperature of 18.6 degrees C and a relative humidity of 74.6%. Based on similar characteristics, a group of representative houses were selected from both urban and suburban areas. The study began by evaluating the airborne fungal concentrations on environmental factors such as area (urban-suburban), season (winter-summer) and presence/absence of a convection gas-fired heating system during winter. Samples were taken with a Standard RCS centrifugal air sampler which operates on the principle of impact onto an agar media strip by centrifugal force. Strips were filled with malt extract agar containing chloramphenicol to inhibit bacterial growth. After incubation and identification, concentrations of airborne fungi were calculated as CFU/m(3). Indoor results showed the presence of thirteen dominant genera: Cladosporium (58.90%), Alternaria (8.68%), Epicoccum (5.74%), Fusarium (5.37%), Curvularia (3.50%), Acremonium (1.27%), Drechslera (1.26%), Penicillium (1.25%), Aspergillus (1.14%), Mucor (0.61%), Ulocladium (0.57%), Nigrospora (0.48%), Chrysosporium (0.42%) and yeast (3.74%), whose presence varied throughout the year. Multivariate Analyses of Variance were performed to study the influence of environmental factors on concentrations of fungal flora. The results obtained were significant for season (lambda=0.1225), area (lambda=0.6371) and for the presence of a convection gas-fired heating system during winter (lambda=0.4765). ANOVA test for the season showed the highest fungal levels (Geometric Mean) in the summer for Alternaria (181.97 CFU/m(3) vs. 17.38 CFU/m(3)), Fusarium (158.49 CFU/m(3) vs. 2.14 CFU/m(3)), Curvularia (66.07 CFU/m(3) vs. 1.62 CFU/m(3)), Acremonium (7.24 CFU/m(3) vs. 2.29 CFU/m(3)), Mucor (3.16 CFU/m(3) vs. 1.15 CFU/m(3)), Nigrospora (2.34 CFU/m(3) vs. 1.07 CFU/m(3)), Chrysosporium (2.73 CFU/m(3) vs. 1.23 CFU/m(3)). In winter, the highest levels (Geometric Mean) were for Penicillium (5.13 CFU/m(3) vs. 1.91 CFU/m(3)) and yeast (16.22 CFU/m(3) vs. 3.09 CFU/m(3)). As for the area, ANOVA showed the highest fungal levels (Geometric Mean) in suburban areas for Cladosporium (676.08 CFU/m(3) vs. 380.19 CFU/m(3)), Curvularia (6.76 CFU/m(3) vs. 4.27 CFU/m(3)) Ulocladium (3.31 CFU/m(3) vs. 1.20 CFU/m(3)) and yeast (18.62 CFU/m(3) vs. 4.90 CFU/m(3)), while Aspergillus (4.57 CFU/m(3) vs. 1.38 CFU/m(3)), showed the highest levels (Geometric Mean) in the urban area. On the other hand, only Cladosporium showed a higher level (Geometric Mean) in houses without convection gas-fired heating system during winter, compared to that corresponding to heated houses.  相似文献   

4.
Literature has suggested association between damp environments, microbial exposure, and higher prevalence of respiratory symptoms and diseases. The study began by evaluating the airborne fungal concentrations at urban and suburban areas of a typical metropolitan city in southern Taiwan for the estimation of related health risks. A group of representative homes, based on the housing characteristics questionnaires completed earlier, were selected from two parts of the city; urban and suburban. Burkard sampler (BURKARD, Rickmansworth, England) was used to collect airborne fungi onto agar plates with malt-extract. After incubation and identification, concentrations of airborne fungi were calculated as CFU/m3. The geometric mean (GM) concentration for indoors was 8946 (4372-18,306) CFU/m3 in winter and 4381 (1605-11,956) in summer. For outdoors, it was 11,464 (5767-22,788) CFU/m3 in winter and 4689 (1895-11,603) in summer. In summer, the total fungal concentration, both indoors and outdoors of suburban homes, were significantly higher than those of urban homes. The dominant fungi contributing to such a difference were indoor Cladosporium spp. and outdoor Penicillium spp. (P < 0.01). The indoor/outdoor ratio (I/O) was similar in two areas except for Penicillium spp. in winter and Aspergillus spp. in summer; both higher in the suburban area. Significantly higher levels of airborne fungi were observed in this region than those seen in northern Taiwan or other parts of the world. Future investigations are needed to further examine the effects of these exposures on the related health problems.  相似文献   

5.
Bioaerosol particles in the atmosphere were collected from the coastal region of Qingdao from Jul. 2009 to Jun. 2010. The concentrations of microorganisms (including culturable, nonculturable, terrestrial and marine microorganisms) were measured. Average concentrations of airborne terrestrial bacteria, marine bacteria, terrestrial fungi, marine fungi and total bioaerosol were in the ranges of 33-664 CFU/m3, 63-815 CFU/m3, 2-777 CFU/m3, 66-1128 CFU/m3 and 85,015-166,094 Cells/m3, respectively. The nonculturable microbes accounted for 99.13% of the total microbes. In addition, there were more culturable marine microbes than culturable terrestrial microbes, and more airborne fungi than bacteria. The concentration of airborne bacteria showed a skewed distribution pattern, while unimodal size distributions were observed for the concentrations of fungi and total microbes. The airborne microbes mainly existed in > 2.1 μm coarse particles. Pearson correlation analysis between the concentrations and meteorological parameters showed that the meteorological parameters had different effects on different kinds of microbes. Sandstorms increased the concentrations of both culturable microbes and total microbes in the bioaerosol.  相似文献   

6.
Biological hazards associated with the collection of solid and compostable waste have not been well characterized in North America. This is an issue because workers who handle such materials may be exposed to bioaerosols (airborne bacteria and fungi) and dusts resulting in infections or allergic diseases. We conducted a personal sampling campaign for culturable bacteria and fungi in the breathing zones of waste collectors in a variety of typical work settings (scenarios) in the province of Quebec, Canada. Total culturable bacterial and fungal counts were analyzed and compared to ambient environmental levels (background) to determine the degree of incremental exposure among workers. In several scenarios, worker exposure counts were significantly (p < or = 0.05) higher than ambient levels measured upwind, with the highest personal exposures to bacteria observed for urban compostable waste collectors (median = 50,300 Colony Forming Units/m(3) of air (CFU/m(3))). On the other hand, fungal counts collected on an every-other-week cycle were highest among a group of rural compostable waste collectors (median = 101,700 CFU/m(3)). Similar exposures to culturable bacteria and fungi have been reported in European workers who showed such adverse health effects as nausea, diarrhea, upper respiratory tract irritation, and allergy. Therefore, it may be necessary to modify certain work practices in order to minimize exposure. Recommendations include automation of waste and compost collection, use of personal protective equipment including goggles, gloves, and disposable masks, and meticulous personal hygiene.  相似文献   

7.
The influence of sampling duration on recovery of culturable fungi was compared using the Andersen N6 and the Reuter Centrifugal Sampler (RCS). Samplers were operated side-by-side, collecting 15 samples each of incrementally increasing duration (1-15 min). From 270 samples collected, 26 fungal genera were recovered. Species of Alternaria, Aspergillus, Cladosporium, Epicoccum, Penicillium and Ulocladium were most frequent. Data adjusted to CFU/m3 were fitted to a Poisson regression model with a logarithmic link function and evaluated for the impact of sampling time on qualitative and quantitative recovery of fungi, both as individual taxa and in aggregate according to xerotolerance. Significant differences between the two samplers were observed for xerotolerant and normotolerant moulds, as well as Aspergillus spp. and Cladosporium spp. With the exception of Cladosporium spp., overall recoveries were higher with the RCS. When the Andersen N6 was used, the recovered levels of Cladosporium spp. and unidentified yeasts were reduced significantly at sampling times over 6 min. Similarly, when the RCS was used, recovery of Aspergillus spp., Penicillium spp., Ulocladium spp., unidentified yeasts, and low water activity fungi declined significantly at sampling times over 6 min. PRACTICAL IMPLICATIONS: Currently, the industry-wide trend for viable air sampling in indoor environmental investigations is to use sampling times between 2 and 4 min in duration. Our results support the routine use of a 6-min sampling time where low spore loads are expected, resulting in improved limits of detection.  相似文献   

8.
Indoor air contains a complex mixture of bioaerosols such as fungi, bacteria and allergens, as well as non-biological particles including products from various combustion processes. To date little work has been done to investigate the interactions and associations between particles of biological and non-biological origin, however, any occurring interactions could affect pollutant behaviour in the air and ultimately the effect they have on health. The aim of this work was to examine associations between the concentration levels of airborne particles and fungi measured in 14 residential suburban houses in Brisbane. The most frequently isolated fungal genus was Cladosporium, Curvularia, Alternaria, Fusarium and Penicillium. The average outdoor and indoor (living room) concentrations of fungal colony forming units were 1133+/-759 and 810+/-389, respectively. Average outdoor and indoor (normal ventilation) concentrations of submicrometre and supermicrometre particles were 23.8 x 10(3) and 21.7 x 10(3) (particles/cm(3)), 1.78 and 1.74 (particles/cm(3)), respectively. The study showed that no statistically significant associations between the fungal spore and submicrometre particle concentrations or PM(2.5) were present, while a weak but statistically significant relationship was found between fungal and supermicrometre particle concentrations (for the outdoors R(2)=0.4, P=0.03 and for a living room R(2)=0.3, P=0.04). A similarity in behaviour between the submicrometre particle and fungal spore concentrations was that the fungal spore concentrations were related directly to the distance from the source (a nearby park), in a very similar way in which the submicrometre particles originating from vehicle emissions from a road, were dependent on the distance to the road. In the immediate proximity to the park, fungal concentrations rose up to approximately 3100 CFU/m(3), whereas for houses more than 150 m away from the park the concentrations of fungi were below 1000 CFU/m(3). Recommendations have been provided as the future study designs to gain a deeper insight into the relationships between biological and non-biological particles.  相似文献   

9.
The information on airborne allergenic fungal flora in rural agricultural areas is largely lacking. Adequate information is not available to the bioaerosol researchers regarding the choice of single versus multiple sampling stations for the monitoring of both viable and non-viable airborne fungi. There is no long-term study estimating the ratios of viable and non-viable fungi in the air and earlier studies did not focus on the fractions of airborne allergenic fungi with respect to the total airborne fungal load. To fill these knowledge gaps, volumetric paired assessments of airborne viable and non-viable fungi were performed in five outdoor sampling stations during two consecutive years in a rural agricultural area of India. Samples were collected at 10-day intervals by the Burkard Personal Slide Sampler and the Andersen Two-Stage Viable Sampler. The data on the concentrations of total and individual fungal types from five stations and 2 different years were analyzed and compared by statistical methods. The allergenicity of the prevalent airborne viable fungi was estimated by the skin-prick tests of >100 rural allergy patients using the antigenic fungal extracts from isolates collected with the Andersen sampler. The ranges of total fungal spore concentration were 82-2365 spores per cubic meter of air (spores/m3) in the first sampling year and 156-2022 spores/m3 in the second sampling year. The concentration ranges of viable fungi were 72-1796 colony-forming units per cubic meter of air (CFU/m3) in the first sampling year and 155-1256 CFU/m3 in the second sampling year. No statistically significant difference was observed between the total spore data of the 2 years, however, the data between five stations showed a significant difference (P<0.0001). No statistically significant difference existed between stations and years with respect to the concentration of viable fungi. When the data of individual allergenic fungal concentrations were compared between stations and years, no statistically significant difference was observed in all cases except for Aspergillus japonicus and Rhizopus nigricans, which showed significant difference in case of stations and years, respectively. The ratios between the total fungal spores collected by the Burkard sampler and the viable fungi collected by the Andersen sampler from all sampling stations ranged between 0.29 and 7.61. The antigenic extracts of eight prevalent viable airborne fungi (A. flavus, A. japonicus, A. fumigatus, Alternaria alternata, Cladosporium cladosporioides, Curvularia pallescens, Fusarium roseum, and R. nigricans) demonstrated >60% positive reactions in the skin prick test. These selected allergenic fungi collectively represented 31.7-63.2% of the total airborne viable fungi in different stations. The study concluded that: (i) a rich fungal airspora existed in the rural study area, (ii) to achieve representative information on the total airborne fungal spores of an area, the monitoring in multiple sampling stations is preferable over a single sampling station; for viable fungi, however, one station can be considered, (iii) the percentage of airborne fungal viability is higher in rural agricultural areas, and (iv) approximately 52% of the viable airborne fungi in the rural study area were allergenic.  相似文献   

10.
对南华大学附一医院,其中一组属于自然通风,一组装有中央空调的室内微生物污染状况进行了两个月的调查,结果发现空调病房微生物污染要明显比自然通风严重:空调病房的平均细菌数(535CFU/m^3)是自然通风(438CFU/m^3)的1.2倍,真菌浓度(174CFU/m^3)为自然通风(113CFU/m^3)的1.5倍。所监测的微生物样品中的80%属于格兰式阳性菌。真菌中最主要的成分是牙枝霉菌,但是在空调病房中牙枝霉菌含量(58.2%)要明显比自然通风(48.6%)高。空调病房在空调刚开启时室内的微生物浓度的最大值大约为3350CFU/m^3,是平均浓度(709CFU/m^3)的4倍,笔者分析产生上述现象的原因,并提出了一些减少空调病房微生物的建议。  相似文献   

11.
We determined the moisture levels, relative humidity (RH) or moisture content (MC) of materials, and concentrations of culturable fungi, actinomycetes and total spores as well as a composition of fungal flora in 122 building material samples collected from 18 moisture problem buildings. The purpose of this work was to clarify if the is any correlation between the moisture parameters and microbial levels or generic composition depending on the type of materials and the time passed after a water damage. The results showed an agreement between the concentrations of total spores and culturable fungi for the wood, wood-based and gypsum board samples (r > 0.47). The concentrations of total spores and/or culturable fungi correlated with RH of materials particularly among the wood and insulation materials (r > 0.79), but not usually with MC (r < 0.45). For the samples collected from ongoing damage, there was a correlation between RH of materials and the concentrations of total spores and culturable fungi (r > 0.51), while such a relationship could not be observed for the samples taken from dry damage. A wide range of fungal species were found in the samples from ongoing damage, whereas Penicillia and in some cases yeasts dominated the fungal flora in the dry samples. This study indicates that fungal contamination can be evaluated on the basis of moisture measurements of constructions in ongoing damage, but the measurements are not solely adequate for estimation of possible microbial growth in dry damage.  相似文献   

12.
Biological hazards associated with the manufacturing of noodles have not been well characterized in Taiwan. This is an issue that flour workers can be exposed to bioaerosols (airborne fungi and bacteria) resulting flour-induced occupational asthma or allergic diseases. This study is to survey the species and concentrations of bioaerosols at different sites within a noodle factory for one year, and to investigate the effects of environmental factors on concentrations of bioaerosols. Air samples were taken twice a day, one day each month using a MAS-100 bioaerosol sampler.Nine species of culturable fungi were identified, with the main airborne fungi being Cladosporium, Penicillium, Aspergillus spp., non-sporing isolates and yeasts. Cladosporium, Penicillium and Aspergillus were the dominant fungal isolates in the indoor and outdoor air samples. Micrococcus spp. and Staphylococcus xylosus were the dominant bacterial isolates. Peak fungal and bacterial concentrations occurred at the crushing site, with mean values of 3082 and 12,616 CFU/m3. Meanwhile, the most prevalent fungi and bacteria at the crushing site were in ranges of 2.1-1.1 μm and 1.1-0.65 μm, respectively. Significant seasonal differences in total bacterial concentration were observed at all sampling sites (?P < 0.05). Moreover, significant seasonal differences were observed for most of the fungal genera except Fusarium. Levels of Aspergillus and Rhizopus differed significantly during the two sampling times, as did levels of Micrococcus spp. and Staphylococcus arlettae.Regarding the same operation procedures, relative humidity affected fungi levels more than temperature did. However, crushing generated the highest concentration of bioaerosols among all operation procedures. Furthermore, levels of bacteria at sites fitted with ventilation systems were lower than at sites without ventilation systems, especially at the crushing site. Therefore, we recommend these workers at the crushing site wear breathing protection and improve the local ventilation systems to minimize the biological hazards.  相似文献   

13.
In August 2009, the historic Typhoon Morakot brought extreme rainfall and resulted in flooding which spread throughout southern Taiwan. This study compared the difference between fungal concentrations before and after the disaster in selected homes of the Tainan metropolitan area, which were hit hardest by the catastrophe. A group of 83 households available from a prior cohort established with random sampling out of a regional population in southern Taiwan was contacted successfully by telephone. Twenty-five of these reported to have suffered from floods of various degrees at this time. Around 2 weeks after the event, at which time most of the remedial process had been completed by self-efforts and public health endeavours, 14 of these 25 (56%) agreed to participate in measurements of the airborne microbial concentrations. The averages (standard deviation) of the total culturable fungal concentrations in children's bedrooms and flooded rooms were 18,181 (25,854) colony-forming units per cubic metre (CFU/m3) and 13,440 (11,033) CFU/m3, respectively. The airborne fungal spore levels in the 2 above-mentioned indoor sites were 221,536 (169,640) spores/m3 and 201,582 (137,091) spores/m3, respectively. The average indoor/outdoor ratios in the children's bedrooms were 4.2 for culturable fungi and 1.4 for fungal spores. These values were higher than the respective values measured in the same homes during the previous year: 1.1 and 0.6. In terms of the specific fungal profile, the percentages of Aspergillus spp. increased significantly in both the indoor and outdoor environments after the event. To this date, this study is among the limited research that has been conducted to quantitatively demonstrate that fungal manifestation is likely to persist in flooded homes even after seemingly robust remedial measures have been put into place. Studies to examine the potential health implications and effectiveness of better remedial technology remain much needed.  相似文献   

14.
A study was undertaken to determine the effect of variations in temperature, relative humidity, occupancy density and location (indoor/outdoor) on the concentrations of viable airborne bacterial and fungal spores at an air-conditioned and a non air-conditioned food stall in Singapore. Typically, bioaerosols consisted of 50.5% bacteria and 49.5% fungi in the indoor environment. In contrast, for the outdoor environment, bacteria on an average only accounted for 20.6% of culturable airborne microorganisms whereas fungal concentrations were 79.4%. Results on bioaerosol size distributions revealed that 67% of indoor bacteria and 68% of outdoor bacteria, 85% of indoor fungi and 68% of outdoor fungi were associated with fine mode particulates (<3.3 μm). Occupant density was the key factor that affected indoor airborne bacteria concentrations while concentrations of outdoor airborne bacteria depended strongly on ambient temperature. Indoor fungal concentration was positively correlated to relative humidity whereas outdoor fungal concentration was positively correlated to relative humidity and negatively correlated to temperature. The study also compared the biological air quality between a non air-conditioned food stall (Stall A) and an air-conditioned food stall (Stall B). The dining area of the former had lower bacterial concentrations as compared to the latter, while fungal spore’s concentrations showed a reverse trend. The dominant airborne bacteria genera were Staphylococcus, Pseudomonas, Alcaligens, and Corynebacterium whereas Penicillium, Aspergillus and Cladosporium were the most common fungal genera and groups in both food stalls.  相似文献   

15.
Qualitative reporting of home indoor moisture problems predicts respiratory diseases. However, causal agents underlying such qualitative markers remain unknown. In the homes of 198 multiple allergic case children and 202 controls in Sweden, we cultivated culturable fungi by directly plating dust, and quantified (1‐3, 1‐6)‐β‐d ‐glucan and ergosterol in dust samples from the child's bedroom. We examined the relationship between these fungal agents and degree of parent or inspector‐reported home indoor dampness, and microbiological laboratory's mold index. We also compared the concentrations of these agents between multiple allergic cases and healthy controls, as well as IgE‐sensitization among cases. The concentrations of culturable fungal agents were comparable between houses with parent and inspector‐reported mold issues and those without. There were no differences in concentrations of the individual or the total summed culturable fungi, (1‐3, 1‐6)‐β‐d ‐glucan, and ergosterol between the controls and the multiple allergic case children, or individual diagnosis of asthma, rhinitis, or eczema. Culturable fungi, (1‐3, 1‐6)‐β‐d ‐glucan, and ergosterol in dust were not associated with qualitative markers of indoor dampness or mold or indoor humidity. Furthermore, these agents in dust samples were not associated with any health outcomes in the children.  相似文献   

16.
Bioaerosol concentrations in residential buildings located in the Northeastern US have not been widely studied. Here, in 2011-2015, we studied the presence and seasonal variability of culturable fungi and bacteria in three multi-family apartment buildings and correlated the bioaerosol concentrations with building ventilation system types and environmental parameters. A total of 409 indoor and 86 outdoor samples were taken. Eighty-five percent of investigated apartments had indoor-outdoor (I/O) ratios of culturable fungi below 1, suggesting minimal indoor sources of fungi. In contrast, 56% of the apartments had I/O ratios for culturable bacteria above 1, indicating the prominence of indoor sources of bacteria. Culturable fungi I/O ratios in apartments serviced by central heating, ventilation, and air-conditioning (HVAC) system were lower than those in apartments with window AC. The type of ventilation system did not have a significant effect on the presence of indoor culturable bacteria. A significant positive association was determined between indoor dew point (DP) levels and indoor culturable fungi (P < .001) and bacteria (P < .001), regardless of ventilation type. Also, residents in apartments with central HVAC did not experience extreme DP values. We conclude that building ventilation systems, seasonality, and indoor sources are major factors affecting indoor bioaerosol levels in residential buildings.  相似文献   

17.
Wu PC  Li YY  Chiang CM  Huang CY  Lee CC  Li FC  Su HJ 《Indoor air》2005,15(1):19-26
Our study conducted serial environmental measurements in 12 large office buildings with two different ventilation designs to obtain airborne microbial concentrations in typical office buildings, and to examine the effects of occupant density, ventilation type and air exchange efficiency on indoor microbial concentrations. Duplicate samples of airborne fungi and bacteria, a total of 2477 measurements, were collected based on a scheme of conducting sampling three times a day for at least seven consecutive days at every study building. Air change rates (ACHs) were also estimated by tracer gas concentration decay method, and measured by continuous Multi-Gas monitor for each building. Most sampling sites were with total fungal and bacteria concentrations higher than 1000 CFU/m(3), an often-quoted guideline in earlier research. Significantly higher concentrations of fungi and bacteria, as well as higher indoor/outdoor (I/O) ratios across most groups of airborne microbes, were identified in buildings with fan coil unit (FCU) system than those with air-handling unit (AHU) system (Student's t test, P < 0.0001). Older buildings and higher air exchange rates were statistically associated with greater indoor bacteria levels in FCU ventilated buildings (R(2) = 0.452); a pattern not found in AHU buildings. Increasing ACH seemed to be the determinant factor for rising indoor fungal and Cladosporium concentrations in those FCU buildings (R(2) = 0.346; 0.518). Our data indicated that FCU ventilated buildings might have provided more outdoor matters into indoor environments through direct penetration of outdoor air. Results also demonstrated a quantitative association between rising numbers of occupants and increasing indoor levels of yeast in both FCU and AHU ventilated buildings. The regression model identified in this study may be considered a reference value for proposing an optimal ACH, while with adequate filtration of fresh air, as an effective strategy in lowering indoor microbial concentrations in air-conditioned buildings. PRACTICAL IMPLICATIONS: As control of indoor microbial contamination has become an increasing concern around the world, feasibility and effectiveness of adopting ventilation approach has attracted a significant interest. This field investigation demonstrated, quantitatively, critical variables to be taken into consideration while applying such a measure, including the kinds of microbes to be removed and the types of ventilation system already in place.  相似文献   

18.
The aim of this study was to investigate the effect of relative humidity (RH) on the aerosolization and total inflammatory potential (TIP) of microbial particles released from gypsum boards inoculated with dust samples from homes. After microbial colonization, the gypsum boards were incubated at either high or low RH. The aerosolized particles (0.54–19.8 μm), culturable fungi, β‐glucan and the TIP of the aerosolized particles were quantified. Despite the colonization of several fungal groups, Penicillium dominated the aerosolized fraction. Higher emission rates of particles and culturable fungi were found from low RH compared with high RH in both the inhalable and particulate matter <1 μm (PM1) fractions, and the TIP was accordingly higher. However, for the aerosolized fractions, the TIP or concentration β‐glucan relative to the number of fungi or particles present was higher from high RH compared with low RH. Despite the low number of culturable fungi in PM1, this fraction showed a high TIP, and the concentration of β‐glucan correlated strongly with the TIP of this fraction. The individual particles of the aerosolized PM1 fraction were more inflammatory than the larger particles of the inhalable fraction, and β‐glucan may be an important contributor to the inflammatory potential of the aerosolized particles.  相似文献   

19.
Green building materials are becoming more popular. However, little is known about their ability to support or limit microbial growth. The growth of fungi was evaluated on five building materials. Two green, two conventional building materials and wood as a positive control were selected. The materials were inoculated with Aspergillus versicolor, Cladosporium cladosporioides and Penicillium brevicompactum, in the absence and presence of house dust. Microbial growth was assessed at four different time points by cultivation and determining fungal biomass using the N‐acetylhexosaminidase (NAHA) enzyme assay. No clear differences were seen between green and conventional building materials in their susceptibility to support microbial growth. The presence of dust, an external source of nutrients, promoted growth of all the fungal species similarly on green and conventional materials. The results also showed a correlation coefficient ranging from 0.81 to 0.88 between NAHA activity and culturable counts. The results suggest that the growth of microbes on a material surface depends on the availability of organic matter rather than the classification of the material as green or conventional. NAHA activity and culturability correlated well indicating that the two methods used in the experiments gave similar trends for the growth of fungi on material surfaces.  相似文献   

20.
Comparisons of two common bioaerosol samplers were made after sampling and enumeration of airborne fungal propagules in several office structures on a university campus in Southern California. Data collected on five occasions throughout the year showed that a Surface Air Systems (SAS) high flow portable sampler recovered consistently lower levels of colony forming units (cfu) than an Andersen N6 single stage impactor. There was no difference statistically between the samplers when concentrations of Cladosporium were compared. Compared to the Andersen N6, the SAS sampler recovered about half the number of cfu for three other fungal categories, i.e. non-sporulating species, Aspergillus and Penicillium and others. Differences in sampler efficiencies are discussed in terms of effective particle diameters. Counts of culturable airborne fungal spores obtained with the SAS sampler should be interpreted with caution when genera other than Cladosporium predominate.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号