首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 593 毫秒
1.
The actual European energy context highlights the building sector as one of the largest sectors of energy consumption. Consequently, the “Energy Performance of Buildings Directive”, adopted in 2002 and focusing on energy use in buildings, requires all the EU members to enhance their building regulations and to introduce energy certification schemes, with the aim of both reducing energy consumption and improving energy efficiency. That is why carrying out an energy performance diagnosis is mandatory, notably when buying or selling properties. Indeed, invisible defaults, like, for example, non-emerging cracks or delaminations, could have a detrimental effect on insulating qualities. Esimaing in situ thermo-physical properties allowing locating these defaults, the present work focuses on proposing new and efficient approaches based on the use of both artificial intelligence tools (artificial neural networks and neuro-fuzzy systems) and inverse methods for characterizing building materials i.e. for estimating their thermal diffusivity using thermograms obtained thanks to a non-destructive photothermal method.  相似文献   

2.
Electrochromic glazing can involve substantial energy consumption in the building sector with their optical properties driven either by various occupant needs or environmental conditions. This paper presents comparison of ten different control strategies developed for such a glazing system in terms of specific energy consumption of a PASSYS test cell where the glazing was installed. The control strategies include scheduled ON–OFF controllers, a PID and advanced fuzzy controllers which were developed using experimental data. We used energy simulation to analyse the annual heating, cooling and lighting demands investigating the influence of each control strategy to the thermal behaviour of the building.  相似文献   

3.
《Energy and Buildings》2001,33(6):531-543
The aim of this paper is to present and evaluate control strategies for adjustment and preservation of air quality, thermal and visual comfort for buildings’ occupants while, simultaneously, energy consumption reduction is achieved. Fuzzy PID, fuzzy PD and adaptive fuzzy PD control methods are applied. The inputs to any controller are: the PMV index affecting thermal comfort, the CO2 concentration affecting indoor air quality and the illuminance level affecting visual comfort. The adaptive fuzzy PD controller adapts the inputs and outputs scaling factors and is based on a second order reference model. More specifically, the scaling factors are modified according to a sigmoid type function, in such a way that the measured variable to be as closer as possible to the reference model. The adaptive fuzzy PD controller is compared to a non-adaptive fuzzy PD and to an ON–OFF one. The comparison criteria are the energy required and the controlled variables response. Both, energy consumption and variables responses are improved if the adaptive fuzzy PD type controller is used. The buildings’ response to the control signals has been simulated using MATLAB/SIMULINK.  相似文献   

4.
住宅空调方案寿命周期能耗和资源消耗研究   总被引:3,自引:1,他引:2  
以某高层住宅为例,按北京市和上海市两地的气候和建筑热工条件,对5种常见住宅空调设计方案的生产能耗和资源消耗进行对比分析,并依据运行能耗调查数据,对3种常见住宅空调方案的寿命周期能耗进行对比分析。结果表明,户式空调和集中空调方案的生产能耗、寿命周期能耗和资源消耗均显著高于分体空调方案。对于所研究的情况,水冷式集中空调方案的寿命周期能耗是分体空调方案的6.6倍,认为分散式空调仍然是目前最节能环保的住宅空调方式,盲目推广集中式空调会使我国住宅空调能耗大幅度增加。  相似文献   

5.
The shortcomings or limitations of the traditional approach to developing energy efficient buildings are that they can not determine: (1) the ideal thermophysical properties of building envelope material, where “ideal” means that such material can use ambient air temperature variation and/or solar radiation efficiently to keep the indoor air temperature in the thermal comfort range with no additional space heating or cooling; (2) the best natural ventilation strategy; (3) the minimal additional energy consumption for space heating in winter or air-conditioning in summer. To overcome these problems, some new concepts for developing energy efficient buildings are put forward in this paper. They are the ideal thermophysical properties of the building envelope material, the ideal natural ventilation rate, and a minimal additional space heating or cooling energy consumption. A new approach for determining these properties is also developed. In contrast to the traditional approach (the thermophysical properties of building envelope material are known and constant so that the relating equations describing the indoor air temperature tend to be linear differential equations), the new approach solves the inverse problem (thermophysical properties, etc. of a buildings are unknown), whose solution can be a function instead of a value. As a first step, the ideal specific heat of the building envelope material for internal thermal mass is analyzed for buildings located in various cities in different climatic regions of China, such as Beijing, Shanghai, Harbin, Urumchi, Lhasa, Kunming and Guangzhou. We found that the ideal specific heat is composed of a basic value and an excessive one which is of δ function for the cases studied. Some limitations that would need further study are introduced in the end of the paper.  相似文献   

6.
In recent years, there has been a dramatic increase in energy consumption in Saudi Arabia. The building sector being the largest consumer of electric energy represents a major potential contributor for reducing energy consumption. Due to their functional and operational characteristics, commercial buildings relatively consume more energy (per unit area) than other types of buildings. The heating, ventilating and air-conditioning system (HVAC) is one of the largest end-users of energy in these buildings, particularly in harsh climates. Energy efficient design and operation of HVAC systems in commercial buildings can offer major opportunities for reduced energy consumption and contribute to sustainable development. However, improper utilization of energy conservation measures can result in reduced environmental quality. This in turn exposes the occupants to thermal discomfort and health risks, and consequently diminishes the economic value of the facility. Therefore, a well assessed and balanced energy conservation strategy is required to achieve energy efficiency while maintaining desired level of thermal comfort. In this study, major design and operational parameters for different types of HVAC systems influencing energy consumption are investigated utilizing the Visual-DOE program. Results indicate that energy savings of up to 30% can be obtained while maintaining acceptable level of thermal comfort when HVAC systems are properly selected and operated.  相似文献   

7.
《Energy and Buildings》2002,34(1):25-31
The paper compares effects on thermal performance and energy use of various pre-cooling and ventilation strategies, which might be used for reducing peak power demands in typical office buildings located in moderately warm climatic regions. Simulations were performed for different features of the building envelope, and for two levels of internal heat load.Results indicate: significant reductions of required daytime peak power loads may be obtained by cooling strategies that contribute to lowering internal mass temperatures. For buildings with large internal heat loads, intensive night pre-cooling is the most effective strategy for smoothing required power loads. However, for non-loaded buildings, it largely increases total energy loads, and night-time peak power loads. Intensive night ventilation reduces required peak power loads as well as total cooling energy loads for both building types. For non-loaded buildings, it is an extremely efficient strategy, whereas the efficacy of other pre-cooling strategies is highly questionable. Further research should include secondary effects (on required peak power loads, total energy loads, and electricity consumption) as they may decrease the efficiency differences between the two strategies.  相似文献   

8.
The aim of the present paper is to propose an analysis of energy consumption of a standard building in different climates. The analysis is developed by simulating the dynamic behaviour of the building subjected to different climatic conditions according to the considered location. Simulations are performed by means of an in-house developed code, validated by comparison with the outcomes from leading software, particularly TRNSYS and EnergyPlus. The use of a self-developed code guarantees a high flexibility and allows the implementation of new capabilities if necessary. The impact on the energy consumption of various parameters, namely internal and external wall insulation, window surface areas, thermal capacity and orientation, is investigated. Results show that the insulation of external walls has a fundamental role in reducing energy consumption, because it allows to exploit the thermal capacity of the walls. This is particularly useful for buildings which necessitate to keep the internal temperature constant.  相似文献   

9.
The building sector offers significant opportunities for reducing the energy consumption with considerable economic, environmental and health benefits. Governments can lead the way by retrofitting existing public buildings to reinforce their commitment to improve energy efficiency. Similar design standards, end-uses and operational profiles are usually established for public buildings based on the services they offer. Retrofitting a public building can therefore serve as an ideal test-bed for energy efficiency measures for other buildings within a particular service category. This study first analysed the current electricity consumption of a public office building in Mauritius, located in the Southern Hemisphere. A complete model of the building was created, validated and then simulated to investigate the impact of realistic retrofit strategies on the electricity consumption. Results showed that lighting retrofit achieved the most significant reduction while measures that improved the thermal envelope of the building resulted in smaller energy savings. The possibility of exploiting solar energy was explored by simulating a 70 kWp photovoltaic system installed on the roof. An equivalent of 8.5% of the annual electricity consumption of the building could thus be generated. A financial analysis is also presented for all retrofit scenarios in terms of annual return and payback period.  相似文献   

10.
被动式超低能耗建筑通过被动式设计策略、高性能的围护结构和高效的设备体系降低其使用阶段能耗。零能耗建筑在此基础上,采用太阳能光伏发电等可再生能源系统,进一步降低不可再生能源消耗。这两类节能建筑的材料和设备系统的隐含能耗、环境影响和成本通常高于一般建筑,同时对构件的后期维护和替换提出了更高的要求。因此,有必要从生命周期的范畴分析其环境和经济效益。建筑信息模型(BIM)能够为建筑项目的建造、运行和拆解等阶段提供多专业共享的数据平台。本文基于BIM,通过LCA和LCC方法对一座小型住宅建筑在不同节能目标情景下的生命周期全球变暖潜势值(GWP)、一次能耗(PE)和成本(LCC)进行分析和比较。结果表明,零能耗乃至正能源建筑在降低一次能耗和GWP方面具有明显优势,被动式超低能耗建筑也具有良好的环境效益。在经济效益方面,由于住宅建筑能源价格较低,如果按近年的价格指数计算,零能耗建筑和被动式超低能耗建筑的初建成本和后期构件替换成本增量将抵消其使用阶段节约的能耗成本,因此生命周期成本高于普通节能建筑。如果未来50年能源价格涨幅超过建筑安装价格涨幅,那么零能耗建筑在生命周期成本方面将具有优势。  相似文献   

11.
Maintaining suitable indoor climate conditions is a need for the occupants’ well being, while requiring very strictly thermal comfort conditions and very high levels of indoor air quality in buildings represents also a high expense of energy, with its consequence in terms of environmental impact and cost. In fact, it is well known that the indoor environmental quality (IEQ), considering both thermal and indoor air quality aspects, has a primary impact not only on the perceived human comfort, but also on the building energy consumption. This issue is clearly expressed by the European Energy Performance of Buildings Directive 2002/92/EC, together with the most recent 2010/31/EU, which underlines that the expression of a judgment about the energy consumption of a building should be always joint with the corresponding indoor environmental quality level required by occupants. To this aim, the concept of indoor environment categories has been introduced in the EN 15251 standard. These categories range from I to III, where category I refers to the highest level of indoor climate requirement. In the challenge of reducing the environmental impact for air conditioning in buildings, it is essential that IEQ requirements are relaxed in order to widen the variations of the temperature ranges and ventilation air flow rates. In this paper, by means of building energy simulation, the heating and cooling energy demand are calculated for a mechanically controlled office building where different indoor environmental quality levels are required, ranging from category I to category III of EN 15251. The building is located in different European cities (Moscow, Torino and Athens), characterized by significantly different wheatear conditions. The mutual relation between heating and cooling energy demand and the required levels of IEQ is highlighted. The simulations are performed on a typical office room which is adopted as a reference in validation tests of the European Standard EN 15265 to validate calculation procedures of energy use for space heating and cooling.  相似文献   

12.
:随着绿色建筑设计理念深入人心,办 公建筑的中庭空间因其特有空间特质受到越来 越多的关注。通常办公中庭空间中的节能性与热 舒适性是一对矛盾体,而自然通风作为被动节能 技术之一,不仅能够促进中庭空间的内外空气 循环,改善室内空气质量,而且降低能耗和提升 热舒适性,较好地解决这一矛盾。以江雅园办公 楼中庭空间为案例进行研究,从中庭屋顶形态、 中庭高度及进风口开启方式三个变量因素出发, 引用模糊评估方法寻找出中庭空间自然通风热 舒适性最佳方案,结论显示在多个组合方案中 斜屋顶形态+进风口全部开启的方案热舒适性最 佳,同时也证明屋顶形态与通风方式的变化对自 然通风舒适性的影响较大,而中庭空间高度的变化对自然通风舒适性影响较小。本研究希望建立一套以风速和温度为评价指标的模糊体系,为自 然通风的热舒适性的评价提供一种客观的评估手段,从而为方案阶段的中庭空间设计提供一种 有效的优化方法。  相似文献   

13.
重庆地区既有住宅建筑节能技术研究与探讨   总被引:2,自引:0,他引:2  
针对重庆地区既有住宅建筑耗能较大这个问题,从气候、环境、地形以及既有建筑热工性能等方面做了分析和研究,介绍了窗、门、墙体和屋顶等部位有效的节能措施和方法,并结合一栋7层既有住宅建筑实例,提出了开展既有住宅建筑节能改造的技术和措施.  相似文献   

14.
《Energy and Buildings》2005,37(5):529-544
The application of bioclimatic principles is a critical factor in reducing energy consumption and CO2 emissions of the building sector. This paper develops a regression model of energy efficiency as a function of environmental conditions, building characteristics and passive solar technologies. A sample of 77 bioclimatic buildings (including 45 houses) was collected, covering Greece, other Mediterranean areas and the rest of Europe. Average energy efficiency varied from 19.6 to 100% with an average of about 68%. Environmental conditions included latitude, altitude, ambient temperature, degree days and sun hours; building characteristics consisted in building area and volume. Passive solar technologies included (among others) solar water heaters, shading, natural ventilation, greenhouses and thermal storage walls. Degree days and a dummy variable indicating location in the Mediterranean area were the strongest predictors of energy efficiency while taller and leaner buildings tended to be more energy efficient. Surprisingly, many passive technologies did not appear to make a difference on energy efficiency while thermal storage walls in fact seemed to decrease energy efficiency. The model developed may be of use to architects, engineers and policy makers. Suggestions for further research include obtaining more building information, investigating the effect of passive solar technologies and gathering information on the usage of building.  相似文献   

15.
Natural ventilation is a proven strategy for maintaining thermal comfort in non-domestic buildings in the UK. The energy consumption and thus the carbon dioxide emissions that contribute to global warming are lower than in conventional air-conditioned buildings. However, the ambient temperatures in the UK have risen over the last decade and new climatic data for use in the design of naturally ventilated buildings has been published. Using these data and dynamic thermal modelling, it is shown that passive stack ventilation alone was unlikely to maintain summertime comfort in a proposed University College London building within an urban heat island. The stack ventilation strategy was evolved by the introduction of passive downdraught cooling. This low-energy technique enables cooled air to be distributed throughout the building without mechanical assistance. The underlying principles of the technique were explored using physical models and the anticipated performance predicted using thermal modelling. The architectural integration is illustrated and the control strategy described. The resulting building is believed to be the first large-scale application of the passive downdraught cooling technique; construction began in late 2003.  相似文献   

16.
While the EU Directive 2002/91/CE on the Energy Performance of Buildings (EPBD) clearly establishes regulations for the thermal insulation of buildings for saving energy in winter, the summer strategy is described by a little more than qualitative provisions. As a consequence, in the national requirements, the high insulation of the building envelope is considered as the principal strategy to control energy consumption even in summer, regardless of the different climates. This approach leads to a homologation of the building trade, and imposes construction technology and materials which do not adhere to the traditional way of making buildings, like in Southern Europe. Here, the “over insulation” of buildings runs the risk of reducing the effectiveness of traditional passive cooling strategies (thermal mass, air permeability of the roof covering, roof ventilation) and could have adverse effects on internal comfort. In this paper, we focus on the effects of over insulation on the thermal performance of roofs in summer, by analyzing experimental data from monitoring a full-scale mock-up in Italy. Results show how an increase in insulation thickness reduces the effectiveness of traditional passive cooling strategies, as an effect of the thermal decoupling between the interior and the upper layers of the roofs.  相似文献   

17.
Natural ventilation is a proven strategy for maintaining thermal comfort in non-domestic buildings in the UK. The energy consumption and thus the carbon dioxide emissions that contribute to global warming are lower than in conventional air-conditioned buildings. However, the ambient temperatures in the UK have risen over the last decade and new climatic data for use in the design of naturally ventilated buildings has been published. Using these data and dynamic thermal modelling, it is shown that passive stack ventilation alone was unlikely to maintain summertime comfort in a proposed University College London building within an urban heat island. The stack ventilation strategy was evolved by the introduction of passive downdraught cooling. This low-energy technique enables cooled air to be distributed throughout the building without mechanical assistance. The underlying principles of the technique were explored using physical models and the anticipated performance predicted using thermal modelling. The architectural integration is illustrated and the control strategy described. The resulting building is believed to be the first large-scale application of the passive downdraught cooling technique; construction began in late 2003.  相似文献   

18.
This paper describes the analytical results of heating energy consumption monitoring and the determination of heat protection levels for both single-family and multi-family buildings in Russia. Experiments have been jointly conducted by Russian and American researchers from the Research Institute for Building Physics, Gosstroy of Russia, and the Natural Resources Defense Council. The paper describes qualimetric methods which provide a quantitative estimation of thermal and energy performance by using instrumental facilities and non-destructive methods.

The first Section gives a brief methodological summary for determining on-site building energy and thermal performance. The second part reviews the field results of energy monitoring to determine techniques that may result in the highest energy conservation effect for standard single-family houses in Russia. The third Section presents a comparative energy analysis of the use of highly insulating windows in a multi-family apartment building in field conditions. The experiments conducted prove that it is possible to ensure a 20–25% reduction in energy consumption for residential buildings under actual conditions existing in Russia. Finally, a methodology for assessing whole-building energy consumption for multi-family buildings is described.  相似文献   


19.
Energy consumption in buildings vary significantly, depending on factors as the use of the building, the construction type, maintenance, existing heating, cooling and lighting systems and other types of services. Hotel buildings have high energy consumption rate, as a result of their unique operational characteristics. Energy consumption in hotels is among the highest in the non-residential building sector in absolute values. Available specific information on the energy characteristics, thermal performance, energy losses, electric loads, and comfort conditions play significant role for the sustainable development of hotel's systems. These data can also be used to identify whether there is space for improvement in new or existing hotels by comparing them against predicted or actual building energy performance. The aim of the present paper is to analyze the energy and exergy utilization in four hotels in Rethimno, Crete (Southern Greece) and in Kassandra, Halkidiki (Northern Greece).  相似文献   

20.
Today, there is a growing interest in developing energy efficient buildings since it is estimated that buildings account for about 40% of the total primary energy consumption in the world. In relation to existing buildings, energy efficiency retrofits have become an important opportunity to upgrade the energy performance of commercial, public and residential buildings that may reduce the energy consumption, demand and cost. In this paper we cover the energy efficiency deep retrofit process that has been carried out for Nottingham Playhouse theatre building for the aim of enhancing its environmental performance and analysing the energy efficiency gained after implementing certain proposed modifications. It is a nationally protected historic building, listed as Grade II1 on The National Heritage List for England (NHLE). The building has had insulation enhancement, doors modifications, solar energy installations, energy-saving lights, in addition to improved heating and air conditioning system. The paper presents a novel methodology; and its results indicate significant improvements in the building's energy performance which is demonstrated using infrared thermographic images and data logger sensors where significant energy savings to the building's thermal performance are obtained. The energy saving measures have been completed while maintaining the heritage building's general appearance and architectural features, which have received a Commendation Certificate from The Nottingham Civic Society for this achievement.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号