首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到9条相似文献,搜索用时 15 毫秒
1.
Little is known about the geographic variation and determinants of bacterial endotoxin and β ‐(1,3)‐d ‐glucan in Danish house dust. In a population of 317 children, we: (i) described loads and concentrations of floor dust, endotoxin, and β‐(1→3)‐d ‐glucan and (ii) their correlations and (iii) assessed their determinants; (iv) Finally, we compared our findings with previous European studies. Bedroom floor dust was analyzed for endotoxin content by the kinetic limulus amoebocyte lysate assay and for β‐(1→3)‐d ‐glucan by the inhibition enzyme immunoassay. The parents answered questions regarding potential determinants. We found: geometric means (geometric standard deviations) 186 mg/m2 (4.3) for dust; 5.46 × 103EU/m2 (8.0) and 31.1 × 103EU/g (2.6) for endotoxin; and 142 μg/m2 (14.3) and 0.71 × 103 μg/g (7.3) for β‐(1→3)‐d ‐glucan. High correlations (> 0.75) were found between floor dust and endotoxin and β‐(1→3)‐d ‐glucan loads, while endotoxin and β‐(1→3)‐d ‐glucan concentrations were moderately correlated (= 0.36–0.41) with the dust load. Having a carpet was positively associated with dust load and with endotoxin and β‐(1→3)‐d ‐glucan concentrations. Pet keeping, dwelling type, and dwelling location were determinants of endotoxin concentrations. No other determinants were associated with β‐(1→3)‐d ‐glucan concentrations. Compared with other European studies, we found lower β‐(1→3)‐d ‐glucan loads and concentrations but higher endotoxin loads and concentrations suggesting a geographically determined different composition of Danish floor dust compared with other European regions.  相似文献   

2.
A randomized controlled trial was carried out to measure the impact of an intervention on ventilation, indoor air contaminants, and asthma symptoms of children. Eighty‐three asthmatic children living in low‐ventilated homes were followed over 2 years. Several environmental parameters were measured during the summer, fall, and winter. The children were randomized after Year 1 (43 Intervention; 40 Control). The intervention included the installation of either a Heat Recovery Ventilator (HRV) or Energy Recovery Ventilator (ERV). During the fall and winter seasons, there was a significant increase in the mean ventilation rate in the homes of the intervention group. A statistically significant reduction in mean formaldehyde, airborne mold spores, toluene, styrene, limonene, and α‐pinene concentrations was observed in the intervention group. There was no significant group difference in change in the number of days with symptoms per 14 days. However, there was a significant decrease in the proportion of children who experienced any wheezing (≥1 episode) and those with ≥4 episodes in the 12‐month period in the intervention group. This study indicates that improved ventilation reduces air contaminants and may prevent wheezing. Due to lack of power, a bigger study is needed.  相似文献   

3.
4.
Y. Sun  Y. Zhang  J. Sundell  Z. Fan  L. Bao 《Indoor air》2009,19(4):348-356
Abstract Abstract A cross‐sectional study was carried out at Tianjin University campus, China, from February 21 to June 10, 2006, to survey the association between dampness in dorms, and allergy and airways infections among college students. The health and dampness conditions were self‐reported by 3436 students living in 1511 dorm rooms located in 13 buildings on the campus. The buildings were selected according to their positions, construction periods and occupant densities. The symptoms involved wheezing, dry cough during night, rhinitis, eczema, cold/flu, ear inflammation, pneumonia and tuberculosis. The indoor moisture signs were mould/damp spots on walls, ceilings and floors; suspected or ever happened water damage; condensation on windowpane in winter and odours perceived by subjects themselves. There was a significant positive association between condensation and dry cough. Eczema was often reported in rooms with moisture problem. Dampness was a significant risk factor for common cold.  相似文献   

5.
The scientific literature on health effects from dampness in buildings, including mite exposure over the period 1998-2000 has been reviewed by an European group (EUROEXPO) of eight scientists in experience from medicine, epidemiology, toxicology and engineering. Forty studies deemed relevant have been the foundation for the conclusions. Dampness in buildings is a risk factor for health effects among atopics and non-atopics both in domestic and in public environments. However, the literature is not conclusive in respect of causative agents, e.g. mites, microbiological agents and organic chemicals from degraded building materials. There is a strong need for more multidisciplinary studies including expertise from all relevant areas. A general conclusion from the work was that there is a strong need for multidisciplinary reviews in scientific journals of articles dealing with associations between indoor environmental factors and health effects. PRACTICAL IMPLICATIONS: There is good evidence for a true association between dampness in buildings and health. As the causative factors behind this association are not known, the main focus in practical investigations should be on finding out and remediate the reasons for the humidity problem.  相似文献   

6.
The contamination of indoor environments with chemical compounds released by materials and furniture, such as semi‐volatile organic compounds (SVOCs), is less documented in schools than in dwellings—yet children spend 16% of their time in schools, where they can also be exposed. This study is one of the first to describe the contamination of the air and dust of 90 classrooms from 30 nursery and primary schools by 55 SVOCs, including pesticides, phosphoric esters, musks, polycyclic aromatic hydrocarbons (PAHs), polychlorobiphenyls (PCBs), phthalates, and polybromodiphenylethers (PBDEs). Air samples were collected using an active sampling method, and dust samples were collected via two sampling methods (wiping and vacuum cleaning). In air, the highest concentrations (median >100 ng/m3) were measured for diisobutyl phthalate (DiBP), dibutyl phthalate (DBP), diethyl phthalate (DEP), bis(2‐ethylhexyl) phthalate (DEHP), and galaxolide. In dust, the highest concentrations (median >30 μg/g) were found for DEHP, diisononyl phthalate (DiNP), DiBP, and DBP. An attempt to compare two floor dust sampling methods using a single unit (ng/m²) was carried out. SVOC concentrations were higher in wiped dust, but frequencies of quantification were greater in vacuumed dust.  相似文献   

7.
8.
Most previous research on indoor environments and health has studied school children or occupants in non‐school settings. This investigation assessed building‐related health symptoms and classroom characteristics via telephone survey of New York State school teachers. Participants were asked about 14 building‐related symptoms and 23 classroom characteristics potentially related to poor indoor air quality (IAQ). Poisson regression analysis was used to assess the relationship between these symptoms and each classroom characteristic, controlling for potential confounders. About 500 teachers completed the survey. The most frequently reported classroom characteristics included open shelving (70.7%), food eaten in class (65.5%), dust (59.1%), and carpeting (46.9%). The most commonly reported symptoms included sinus problems (16.8%), headache (15.0%), allergies/congestion (14.8%), and throat irritation (14.6%). Experiencing one or more symptoms was associated most strongly with reported dust (relative risk (RR) = 3.67; 95% confidence interval (CI): 2.62–5.13), dust reservoirs (RR = 2.13; 95% CI: 1.72–2.65), paint odors (RR = 1.73; 95% CI: 1.40–2.13), mold (RR = 1.71; 95% CI: 1.39–2.11), and moldy odors (RR = 1.65 95% CI: 1.30–2.10). Stronger associations were found with increasing numbers of reported IAQ‐related classroom characteristics. Similar results were found with having any building‐related allergic/respiratory symptom. This research adds to the body of evidence underscoring the importance to occupant health of school IAQ.  相似文献   

9.
F. Wang  J. Wang  Y. Li  X. Han  H. Hu  C. Yu  J. Yuan  P. Yao  X. Miao  S. Wei  Y. Wang  W. Chen  Y. Liang  H. Guo  X. Zhang  H. Yang  T. Wu  M. He 《Indoor air》2018,28(2):238-246
Experimental and epidemiological studies indicated that ambient air pollution was positively associated with diabetes. Few studies investigated the associations between household air pollution, for example, daily cooking duration and diabetes or prediabetes. We conducted a cross‐sectional study to investigate the associations of daily cooking duration with the prevalence of diabetes and prediabetes among a middle‐aged and elderly population. A total of 26 089 individuals (11 250 males and 14 839 females) derived from the Dongfeng‐Tongji cohort study were included. Daily cooking duration was assessed by questionnaire. Diabetes and prediabetes were identified according to the criterion of American Diabetes Association. No significant association was observed between daily cooking duration and the prevalence risk of diabetes (odds ratio[OR] = 0.97, 95% confidence interval[CI]: [0.81‐1.16], P for trend = .74); however, longer daily cooking duration was associated with higher prevalence risk of prediabetes (OR = 1.26, 95% CI: 1.07‐1.47; P for trend = .003) and hyperglycemia (OR = 1.21, 95% CI: 1.05‐1.41; P for trend = .005). Our study suggested that daily cooking duration was not associated with diabetes but with higher prevalence risk of prediabetes/hyperglycemia in a middle‐aged and elderly Chinese population.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号