首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Conventional balloon angioplasty treatment of aorto-ostial stenoses in native coronary arteries and saphenous vein grafts is associated with a low primary success rate, a high complication rate and a high incidence of restenosis. The short-term outcome of Palmaz-Schatz stent implantation in aorto-ostial lesions was compared with that of balloon angioplasty. Thirteen patients underwent stent implantation for 13 de novo lesions (four in the left main coronary trunk, two in the right coronary artery, seven in the vein graft) between January 1994 and December 1995. Fourteen patients underwent balloon angioplasty for 14 de novo lesions (five in the left main coronary trunk, four in the right coronary artery, five in the vein graft between January 1986 and April 1992. Both groups had similar clinical characteristics. Initial success was obtained in all patients in the stent group, compared with 71% of the balloon angioplasty group. Insufficient dilation was the main cause for such failure in the balloon angioplasty group. Baseline reference diameters were similar (3.40 +/- 0.65 mm in the stent group vs 3.36 +/- 0.42 mm in the balloon angioplasty group) and there was no difference in baseline minimal luminal diameter (1.41 +/- 0.74 vs 1.08 +/- 0.56 mm). Minimal luminal diameter was significantly greater in the stent group than in the balloon angioplasty group at both post-procedure and follow-up examinations (post: 3.36 +/- 0.58 vs 2.69 +/- 0.45 mm, p < 0.01; follow-up: 2.33 +/- 0.96 vs 1.52 +/- 0.68 mm, p < 0.05). There was no subacute occlusion in either group. The overall angiographic restenosis rate (> 50% stenosis) was lower in the stent group (17%) than in the balloon angioplasty group: the restenosis rates of native lesions were 0% in the stent group and 40% in the balloon angioplasty group; those of saphenous vein graft lesions were 33% in the stent group and 50% in the balloon angioplasty group. Although the number of patients was limited, these results suggest that Palmaz-Schatz stent implantation may be a safe and effective strategy for treating aorto-ostial lesions in both native coronary arteries and saphenous vein grafts.  相似文献   

2.
OBJECTIVES: The purpose of this prospective study was to evaluate the immediate results and the 6-month angiographic recurrent restenosis rate after balloon angioplasty for in-stent restenosis. BACKGROUND: Despite excellent immediate and mid-term results, 20% to 30% of patients with coronary stent implantation will present an angiographic restenosis and may require additional treatment. The optimal treatment for in-stent restenosis is still unclear. METHODS: Quantitative coronary angiography (QCA) analyses were performed before and after stent implantation, before and after balloon angioplasty for in-stent restenosis and on a 6-month systematic coronary angiogram to assess the recurrent angiographic restenosis rate. RESULTS: Balloon angioplasty was performed in 52 patients presenting in-stent restenosis. In-stent restenosis was either diffuse (> or =10 mm) inside the stent (71%) or focal (29%). Mean stent length was 16+/-7 mm. Balloon diameter of 2.98+/-0.37 mm and maximal inflation pressure of 10+/-3 atm were used for balloon angioplasty. Angiographic success rate was 100% without any complication. Acute gain was lower after balloon angioplasty for in-stent restenosis than after stent implantation: 1.19+/-0.60 mm vs. 1.75+/-0.68 mm (p=0.0002). At 6-month follow-up, 60% of patients were asymptomatic and no patient died. Eighteen patients (35%) had repeat target vessel revascularization. Angiographic restenosis rate was 54%. Recurrent restenosis rate was higher when in-stent restenosis was diffuse: 63% vs. 31% when focal, p=0.046. CONCLUSIONS: Although balloon angioplasty for in-stent restenosis can be safely and successfully performed, it leads to less immediate stenosis improvement than at time of stent implantation and carries a high recurrent angiographic restenosis rate at 6 months, in particular in diffuse in-stent restenosis lesions.  相似文献   

3.
BACKGROUND: Treatment of stenosis in saphenous-vein grafts after coronary-artery bypass surgery is a difficult challenge. The purpose of this study was to compare the effects of stent placement with those of balloon angioplasty on clinical and angiographic outcomes in patients with obstructive disease of saphenous-vein grafts. METHODS: A total of 220 patients with new lesions in aortocoronary-venous bypass grafts were randomly assigned to placement of Palmaz-Schatz stents or standard balloon angioplasty. Coronary angiography was performed during the index procedure and six months later. RESULTS: As compared with the patients assigned to angioplasty, those assigned to stenting had a higher rate of procedural efficacy, defined as a reduction in stenosis to less than 50 percent of the vessel diameter without a major cardiac complication (92 percent vs. 69 percent, P<0.001), but they had more frequent hemorrhagic complications (17 percent vs. 5 percent, P<0.01). Patients in the stent group had a larger mean (+/-SD) increase in luminal diameter immediately after the procedure (1.92+/-0.30 mm, as compared with 1.21+/-0.37 mm in the angioplasty group; P<0.001) and a greater mean net gain in luminal diameter at six months (0.85+/-0.96 vs. 0.54+/-0.91 mm, P=0.002). Restenosis occurred in 37 percent of the patients in the stent group and in 46 percent of the patients in the angioplasty group (P=0.24). The outcome in terms of freedom from death, myocardial infarction, repeated bypass surgery, or revascularization of the target lesion was significantly better in the stent group (73 percent vs. 58 percent, P = 0.03). CONCLUSIONS: As compared with balloon angioplasty, stenting of selected venous bypass-graft lesions resulted in superior procedural outcomes, a larger gain in luminal diameter, and a reduction in major cardiac events. However, there was no significant benefit in the rate of angiographic restenosis, which was the primary end point of the study.  相似文献   

4.
PURPOSE: To evaluate clinical success and long-term patency of a Wallstent in the renal artery. MATERIALS AND METHODS: Twenty-five Wallstents were placed in 21 patients to treat delayed restenosis after previous balloon angioplasty (n = 13) or inadequate immediate postangioplasty response (n = 8). Indications for angioplasty were hypertension in all patients and renal preservation in seven. Stenosis was atheromatous in 15 patients, involving ostium in seven. RESULTS: Stent placement was successful in all patients. At follow-up angiography (range, 12-60 months), four patients (20%) had stent restenosis. Of these, three had undergone treatment for restenosis after angioplasty and three had ostial lesions. Cumulative primary patency rate was 95%, 85%, and 77% at 7, 9, and 15 months, respectively. Hypertension was cured in three patients and improved in 18. CONCLUSION: Arterial stent placement has good clinical results and high long-term patency rates after conventional renal angiography or delayed restenosis, especially in ostial lesions.  相似文献   

5.
OBJECTIVES: This study was performed to determine predictors of in-stent restenosis from a high volume, single-center practice. BACKGROUND: Intracoronary stents have been shown to reduce the restenosis rate as compared with balloon angioplasty, but in-stent restenosis continues to be an important clinical problem. METHODS: Between April 1993 and March 1997, 1,706 patients with 2,343 lesions were treated with a variety of intracoronary stents. The majority of stents were placed with high pressure balloon inflations and intravascular ultrasound (IVUS) guidance. Angiographic follow-up was obtained in 1,173 patients with 1,633 lesions (70%). Clinical, angiographic and IVUS variables were prospectively recorded and analyzed by univariate and multivariate models for the ability to predict the occurrence of in-stent restenosis defined as a diameter stenosis > or =50%. RESULTS: In-stent restenosis was angiographically documented in 282 patients with 409 lesions (25%). The restenosis group had a significantly longer total stent length, smaller reference lumen diameter, smaller final minimal lumen diameter (MLD) by angiography and smaller stent lumen cross-sectional area (CSA) by IVUS. In lesions where IVUS guidance was used, the restenosis rate was 24% as compared with 29% if IVUS was not used (p < 0.05). By multivariate logistic regression analysis, longer total stent length, smaller reference lumen diameter and smaller final MLD were strong predictors of in-stent restenosis. In lesions with IVUS guidance, IVUS stent lumen CSA was a better independent predictor than the angiographic measurements. CONCLUSIONS: Achieving an optimal stent lumen CSA by using IVUS guidance during the procedure and minimizing the total stent length may reduce in-stent restenosis.  相似文献   

6.
In some patients with hypertension or renal insufficiency, renal artery stenosis can play a causative part. If fibromuscular dysplasia is the pathology of the stenosis, treatment of the stenosis by transluminal percutaneous renal angioplasty (TPRA) results in improvement of the concomitant hypertension in 80-90% of the patients. In case of atherosclerotic lesions 50% of the patients benefit by such treatment. In renal insufficiency TPRA of atherosclerotic lesions results in improvement of renal function in only one third of the patients. As restenosis and elastic recoil are seen as the prime determinants of this lack of success in atherosclerosis, intravascular stents were developed with the aim to accomplish a permanent dilation of the arterial lumen. In recent studies stent placement resulted in cure of high blood pressure in 0-16% of the patients and in improvement in 35-70%. The percentage of improvement must be viewed with caution because of the open design of these studies. Improvement of renal function was reported in 7-36% of the patients and worsening in 8-18%. Based on these outcomes stent placement in stenosed renal arteries should not be regarded as a routine clinical treatment.  相似文献   

7.
PURPOSE: Suboptimal distal coronary flow reserve after successful balloon angioplasty has been attributed to angiographically unrecognized inadequate lumen expansion, and adjunct coronary stenting has been shown to improve coronary flow reserve. The aim of this study was to investigate whether myocardial fractional flow reserve (FFRmyo) would increase further after coronary stenting compared with balloon angioplasty alone in the same patient group. METHODS: FFRmyo and quantitative coronary angiography were obtained before and after pre-stent balloon dilation, and again after stent placement in 11 patients (7 left anterior descending artery, 3 right coronary artery and 1 left circumflex artery). FFRmyo was calculated as the ratio of Pd/Pa during intracoronary adenosine 5'-triphosphate (50 micrograms and 20 micrograms in the left and right coronary arteries, respectively)-induced maximum hyperemia, where Pd represents mean distal coronary pressure measured by a 2.1 Fr infusion catheter and Pa represents mean aortic pressure measured by the guiding catheter. RESULTS: Percent diameter stenosis significantly decreased after balloon angioplasty (74% +/- 15% vs 37% +/- 17%, p < 0.001), and decreased further after stent placement (18% +/- 10%, p < 0.001 vs baseline and balloon angioplasty). FFRmyo after coronary stenting (0.85 +/- 0.09) was significantly higher than that at baseline (0.51 +/- 0.16, p < 0.001) and after balloon angioplasty (0.77 +/- 0.11, p < 0.05). There was a significant correlation between angiographic variables and FFRmyo. The increase in lumen dimensions after coronary stenting was followed by a further significant improvement of FFRmyo. CONCLUSION: These results suggest that coronary stenting may provide a more favorable functional status and lumen geometry of residual coronary stenosis compared with balloon angioplasty alone.  相似文献   

8.
Branch pulmonary artery stenosis is a common problem in pediatric cardiology. Treatment has included surgery, balloon angioplasty, and balloon expandable stent placement. It was the purpose of this investigation to demonstrate the cost-effectiveness of each of these modes of treatment. From 1983 to 1994 there were 30 patients admitted for treatment of branch pulmonary artery stenosis only. Data included age at procedure, sex, primary diagnosis, acute and intermediate term success, and complications. Acute success was defined by results at the end of the procedure where intermediate term (IT) success was defined by results at follow-up. Success of a procedure was defined by at least one of the following: an increase in vessel diameter by >/=50% of predilation diameter, a decrease in right ventricular to left ventricular or aortic systolic pressure ratio by >/=20%, or a decrease in peak to peak pressure gradient by >/=50%. The procedure was considered a failure if the previously mentioned criteria were not met or if the patient required a second procedure for the same stenosis. The expense of the procedure (estimated by using the patient charges) were collected from the time of the procedure until December 1994. Because of differing lengths of follow-up, the patients were analyzed separately for procedures and outpatient charges. The total charges were corrected to 1994 dollars using the Medical Consumer Price Index. Thirty patients had 46 separate procedures (12 patients had >1 procedure and 3 had >2 procedures). There were 13 surgeries, 13 balloon angioplasties, and 20 stents. Stents were the most successful (90% acute and 85% IT), but were not statistically superior to surgery (62% acute and IT). Balloon angioplasty was significantly less successful as compared with stents (31% acute and 23% IT), and was not statistically different from surgery over the acute and intermediate term. The charge data showed balloon angioplasty was the least expensive followed by stents and then by surgery. The average total charges per procedure, including outpatient charges, were: surgery $58,068 +/- $4372 (standard error), balloon $21,893 +/- $5019, stents $33,809 +/- $3533 (p < 0.001); excluding outpatient charges: surgery $52,989 +/- $3649, balloon $15,653 +/- $1691, and stents $29,531 +/- $2241 (p < 0.001). Average total charges per patient, including all procedure types and grouped by initial procedure, were: surgery $53,707 +/- $6388, balloon $50,040 +/- $8412, and stent $34,346 +/- $3488 (p = 0.047). Stents were at least as effective as surgery and were more effective than balloon angioplasty in both acute and intermediate term follow-up. Balloon angioplasty was least expensive per procedure but was also least effective. Therefore, intravascular balloon expandable stents are the most cost-effective means available in the treatment of branch pulmonary artery stenosis.  相似文献   

9.
AIMS: To evaluate the feasibility and safety of elective carotid stent implantation in patients with carotid stenoses and concomitant coronary artery disease, as an alternative to combined carotid and coronary surgery. METHODS: We treated 50 patients with >70%, stenoses in 53 carotid arteries with balloon angioplasty followed by elective stent implantation. All patients had severe coronary artery disease, and/or mitral insufficiency, aortic stenosis, rhythm disorders or generalized arteriosclerosis. In three patients the opposite carotid artery was occluded; nine patients had bilateral stenoses of which two received stents bilaterally. RESULTS: Fifty-six successful stent implantations (42 Wallstents, eight BeStents, two AVE-Microstents, one Palmaz Schatz stent, three Sito stents) were performed, reducing the baseline percent stenosis from 78 +/- 18%, to 13 +/- 11%. Complications included three transient ischaemic attacks, one minor and one major stroke. Follow-up was available for 46 patients over a mean of 10 months. Three asymptomatic restenoses and one deformation of a BeStent occurred. CONCLUSION: Our preliminary results indicate that carotid artery stenting in patients with concomitant severe coronary artery disease is feasible, safe, and may be an alternative to combined carotid and coronary surgery.  相似文献   

10.
It is unclear whether new devices such as directional coronary atherectomy (DCA) or Palmaz-Schatz stent implantation improve long-term outcomes compared with conventional balloon angioplasty in patients with stable angina and de novo coronary artery lesions of type A or type B except for complete occlusive lesions investigated by the American College of Cardiology/American Heart Association task force on percutaneous transluminal coronary angioplasty. A total of 146 patients with stable angina and simple lesions were assigned to either conventional balloon angioplasty (62 patients), DCA (50 patients), or Palmaz-Schatz implantation (34 patients). The acute results and late outcomes were assessed by coronary angiography. The results of the three procedures were similar with respect to procedural success and complications. Patients who underwent stenting or DCA had a larger immediate increase in the diameter of the lumen and a larger luminal diameter immediately after the procedure than those who underwent balloon angioplasty. At six months follow-up, the patients treated by stenting continued to have a larger luminal diameter and a lower rate of restenosis than those treated with balloon angioplasty (2.30 +/- 0.66 vs 1.85 +/- 0.83 mm, p < 0.005; 5.9% vs 29%, p < 0.05) and DCA (2.30 +/- 0.66 vs 1.90 +/- 0.96 mm, p < 0.05; 5.9% vs 24%, NS). The patients treated with balloon angioplasty had a smaller late loss than those treated with DCA or Palmaz-Schatz stent. The patients treated with DCA had a larger loss index than those treated with balloon angioplasty or Palmaz-Schatz stent. Stenting was a significant factor in decreasing the rate of restenosis by logistic regression analysis, compared with balloon angioplasty. The angiographic outcomes were better in patients who received a stent than in those who received other treatments. This study suggests that even lesions stable for treatment by balloon angioplasty and DCA can also be treated with Palmaz-Schatz stents.  相似文献   

11.
RATIONALE AND OBJECTIVES: Coronary artery stents reduce the rate of restenosis in patients who have undergone balloon angioplasty; therefore, the implantation of coronary stents represents an important method in the treatment of coronary stenoses. The authors' purpose was to investigate the usefulness of electron-beam computed tomography (CT) as a noninvasive means of assessing the patency of coronary artery stents in patients who had undergone balloon angioplasty and stent placement. MATERIALS AND METHODS: Electron-beam CT was used to assess stent patency in 177 patients with 285 stents. Contrast material-enhanced multisection flow studies were performed, and the images were evaluated by three investigators and compared with the findings of coronary angiography. RESULTS: Cine loop evaluations and time-attenuation curve analysis led to the correct diagnosis in 167 (94.3%) patients, as confirmed with coronary angiography. Stenoses had occurred in 18 of the 194 vessels with stents, and 14 of these were detected with electron-beam CT. CONCLUSION: Electron-beam CT appears to be a valuable imaging modality in the noninvasive assessment of stent patency in coronary arteries.  相似文献   

12.
BACKGROUND: Intracoronary stenting reduces the rate of restenosis after angioplasty in patients with new coronary lesions. We conducted a prospective, randomized, multicenter study to determine whether intracoronary stenting, as compared with standard balloon angioplasty, reduces the recurrence of luminal narrowing in restenotic lesions. METHODS: A total of 383 patients who had undergone at least one balloon angioplasty and who had clinical and angiographic evidence of restenosis after the procedure were randomly assigned to undergo standard balloon angioplasty (192 patients) or intracoronary stenting with a Palmaz-Schatz stent (191 patients). The primary end point was angiographic evidence of restenosis (defined as stenosis of more than 50 percent of the luminal diameter) at six months. The secondary end points were death, Q-wave myocardial infarction, bypass surgery, and revascularization of the target vessel. RESULTS: The rate of restenosis was significantly higher in the angioplasty group than in the stent group (32 percent as compared with 18 percent, P= 0.03). Revascularization of the target vessel at six months was required in 27 percent of the angioplasty group but in only 10 percent of the stent group (P=0.001). This difference resulted from a smaller mean (+/-SD) minimal luminal diameter in the angioplasty group (1.85+/-0.56 mm) than in the stent group (2.04+/-0.66 mm), with a mean difference of 0.19 mm (P=0.01) at follow-up. Subacute thrombosis occurred in 0.6 percent of the angioplasty group and in 3.9 percent of the stent group. The rate of event-free survival at 250 days was 72 percent in the angioplasty group and 84 percent in the stent group (P=0.04). CONCLUSIONS: Elective coronary stenting was effective in the treatment of restenosis after balloon angioplasty. Stenting resulted in a lower rate of recurrent stenosis despite a higher incidence of subacute thrombosis.  相似文献   

13.
Little is known about the frequency of adverse events in the year following stent placement in patients treated with aspirin and ticlopidine, without warfarin. We analyzed the first such 234 consecutive patients treated at our hospital between October 1994 and December 1995. Their mean age was 62+/-12 years; 40% had had a prior myocardial infarction, 22% had undergone coronary artery bypass surgery, and 65% had multivessel disease. The indication for stent placement was dissection or abrupt closure in 24% of patients and suboptimal balloon angioplasty results in 14%; placement was elective in 62% of patients. Three hundred forty-five coronary segments were treated in the 234 patients; 305 stents (1.3 stents/patient) were placed. Palmaz-Schatz coronary stents (75%), Gianturco-Roubin stents (21%), and Johnson & Johnson biliary stents (4%) were used. Mean nominal stent size was 3.4+/-0.4 mm. High-pressure inflations (> or = 14 atm, mean 17+/-2) were performed in all patients. The mean residual stenosis was 3+/-5% by visual estimate. Intravascular ultrasound was utilized to facilitate stent placement in 53% of patients. Mean follow-up was 1.6+/-0.5 years. There were no deaths, Q-wave myocardial infarctions, coronary artery bypass operations, or repeat angioplasty procedures required during the remainder of the hospitalization or in 30 days after stent placement; stent thrombosis did not occur. Kaplan-Meier analysis of adverse events in the 6 months following the procedure revealed a mortality rate of 0.9%; the rate of myocardial infarction (Q-wave or non-Q-wave) was 1.3%. Bypass surgery was performed in 0.9% and angioplasty for in-stent restenosis was performed in 9.5% of patients. Any 1 of these events occurred in 11.7% of patients in the 6 months after the procedure. The corresponding event rates at 1 year were 1.3%, 2.2%, 3.5%, and 12.2%, respectively; any 1 of these events occurred in 16.5% of patients. In patients receiving intracoronary stents of varying designs followed by high-pressure postdeployment inflations in whom an excellent visual angiographic result is achieved, antithrombotic therapy with aspirin and ticlopidine is associated with a very low frequency of adverse cardiovascular events in the 12 months following the procedure regardless of the indication for stent placement.  相似文献   

14.
OBJECTIVES: We sought to determine predictors of restenosis after coronary stenting (CS) in a consecutive series of patients. BACKGROUND: Although stenting in highly selected patient groups reduces restenosis, the results of stenting in a heterogeneous patient group and the effects of clinical and procedural factors on stent restenosis are currently unclear. METHODS: We analyzed the 6-month angiographic outcome of 500 lesions in 463 consecutive patients undergoing successful CS. Clinical, qualitative and quantitative angiographic variables were correlated with restenosis assessed as both a binary and a continuous variable. RESULTS: Restenosis, defined as the presence of >50% diameter stenosis in the dilated segment, was present in 105 (26%) of the 405 lesions with angiographic follow-up. The mean late lumen loss during the follow-up period was 0.79+/-0.64 mm. Implantation of multiple stents (p < 0.0001) and a high acute gain (p < 0.0002) were independently associated with a higher late lumen loss. In contrast, the use of high inflation pressure (p < 0.02) and Palmaz-Schatz stents (p < 0.005) was independently associated with a lower late lumen loss. When restenosis was defined as a qualitative variable, implantation of multiple stents (p < 0.001), stenosis length (p < 0.01), small reference diameter (p < 0.02) and stent type other than Palmaz-Schatz (p < 0.01) were independent predictors of restenosis. None of the clinical variables tested was associated with restenosis. CONCLUSIONS: Coronary stenting in an unselected patient group is associated with an acceptable restenosis rate. Although some risk factors were identified, the risk of restenosis was not related to most of the variables tested. This suggests that the superiority of CS over balloon angioplasty, in terms of restenosis, might also apply to subgroups of patients that were not included in the recent randomized studies.  相似文献   

15.
Data for the effects on blood pressure of renal artery balloon angioplasty are mostly from uncontrolled studies. The aim of this study was to document the efficacy and safety of angioplasty for lowering blood pressure in patients with atherosclerotic renal artery stenosis. Patients were randomly assigned antihypertensive drug treatment (control group, n = 26) or angioplasty (n = 23). Twenty-four-hour ambulatory blood pressure, the primary end point, was measured at baseline and at termination. Termination took place 6 months after randomization or earlier in patients who developed refractory hypertension. In those allocated angioplasty, antihypertensive treatment was discontinued after the procedure but was subsequently resumed if hypertension persisted. Secondary end points were the treatment score and the incidence of complications. Two patients in the control group and 6 in the angioplasty group suffered procedural complications (relative risk, 3.4; 95% confidence interval, 0.8 to 15.1). Early termination was required for refractory hypertension in 7 patients in the control group. Antihypertensive treatment was resumed in 17 patients in the angioplasty group. Mean ambulatory blood pressure at termination did not differ between control (141+/-15/84+/-11 mm Hg) and angioplasty (140+/-15/81+/-9 mm Hg) groups. Angioplasty reduced by 60% the probability of having a treatment score of 2 or more at termination (relative risk, 0.4; 95% confidence interval, 0.2 to 0.7). There was 1 case of dissection with segmental renal infarction and 3 of restenosis in the angioplasty group. No patient suffered renal artery thrombosis. In unilateral atherosclerotic renal artery stenosis, angioplasty is a drug-sparing procedure that involves some morbidity. Previous uncontrolled and unblinded assessments of angioplasty overestimated its potential for lowering blood pressure.  相似文献   

16.
Historically, long coronary artery stenoses undergoing percutaneous transluminal coronary angioplasty (PTCA) are reported to have reduced procedural and clinical success in comparison with shorter lesions. The efficacy of long balloons (30 or 40 mm) in long lesions was evaluated. Eighty-two patients had 84 PTCA procedures with a primary long balloon. In all, 86 lesions were available for analysis. Data were collected prospectively on standard PTCA procedure forms. Coronary angiograms were reviewed and measured with digital calipers. Hospital charts were examined for complications. PTCA was performed in the left anterior descending artery in 44 cases (51%), the right coronary artery in 29 (34%) and the circumflex artery in 13 (15%). With the use of a modified classification system, 47 lesions (55%) were class C, 24 (28%) were class B2 and 15 (17%) were class B1. Mean lesion length was 22 +/- 11 mm (range 10 to 72), and 38 lesions (44%) were > or = 20 mm. Twelve patients received an intracoronary stent. The long balloon alone produced angiographic success (< 50% residual stenosis) in 77 lesions (90%). Angiographic success was achieved ultimately in all stenoses, using a stent in 7 patients and a short balloon in 2. There were 2 deaths (2%) and 1 Q-wave myocardial infarction (1%). One patient needed coronary artery bypass surgery. Clinical success without death, Q-wave infarction or bypass surgery was achieved in 83 of 86 procedures (97%). In conclusion, the use of long PTCA balloons with adjuvant stenting produced excellent results in these long stenoses. Lesion length was not a precursor of poor angiographic or clinical outcome.  相似文献   

17.
OBJECTIVES: This study was designed to examine whether oversized implantation of the new, less shortening Wallstent provides a more favorable long-term clinical and angiographic outcome in chronic total occlusions than does conventional coronary balloon angioplasty. BACKGROUND: Restenosis and reocclusion remain major limitations of balloon angioplasty for chronic total occlusions. Enforced mechanical remodeling by implantation of the oversized Wallstent may prevent elastic recoil and improve accommodation of intimal hyperplasia. METHODS: Lumen dimension was measured by a computer-based quantitative coronary angiography system (CAAS II). These measurements (before and after intervention and at 6-month follow-up) were compared between the groups with Wallstent implantation (20 lesions, 20 patients) and conventional balloon angioplasty (266 lesions, 249 patients) for treatment of chronic total occlusion. Acute gain (minimal lumen diameter after intervention minus that before intervention), late loss (minimal lumen diameter after intervention minus that at follow-up) and net gain (acute gain minus late loss) were examined. RESULTS: Wallstent deployment was successful in all patients. High pressure intra-Wallstent balloon inflation (mean +/- SD 14 +/- 3 atm) was performed in all lesions. Although vessel size did not differ between the Wallstent and balloon angioplasty groups, acute gain was significantly greater in the Wallstent group (2.96 +/- 0.55 vs. 1.61 +/- 0.34 mm, p < 0.0001). Although late loss was also significantly larger in the Wallstent group (0.81 +/- 0.95 vs. 0.43 +/- 0.68 mm, p < 0.05), net gain was still significantly greater in this group (2.27 +/- 1.00 vs. 1.18 +/- 0.69 mm, p < 0.0001). Angiographic restenosis (> or = 50% diameter stenosis) occurred at 6 months in 29% of lesions in the Wallstent group and in 45% of those in the balloon angioplasty group (p = 0.5150). CONCLUSIONS: Implantation of the oversized Wallstent, with full coverage of the lesion length, ensures resetting of the vessel size to its original caliber before disease and allows greater accommodation of intimal hyperplasia and chronic vessel recoil. Wallstent implantation provides a more favorable short- and long-term clinical and angiographic outcome than does conventional balloon angioplasty for chronic total occlusions.  相似文献   

18.
OBJECTIVES: This study was undertaken to validate the in vivo intravascular ultrasound (IVUS) measurement of in-stent neointimal hyperplasia (IH) volumes. BACKGROUND: Because stents reduce restenosis compared to balloon angioplasty, stent use has increased significantly. As a result, in-stent restenosis is now an important clinical problem. Serial IVUS studies have shown that in-stent restenosis is secondary to intimal hyperplasia. To evaluate strategies to reduce in-stent restenosis, accurate measurement of in-stent neointimal tissue is important. METHODS: Using a porcine coronary artery model of in-stent restenosis, single Palmaz-Schatz stents were implanted into 16 animals with a stent:artery ratio of 1.3:1. Intravascular ultrasound imaging was performed at 1 month, immediately prior to animal sacrifice. In vivo IVUS and ex vivo histomorphometric measurements included stent, lumen and IH areas; IH volumes were calculated with Simpson's rule. RESULTS: Intravascular ultrasound measurements of IH (30.4+/-11.0 mm3) volumes correlated strongly with histomorphometric measurements (26.7+/-8.5 mm3, r=0.965, p < 0.0001). The difference between the IVUS and the histomorphometric measurements of IVUS volume was 4.1+/-2.7 mm3 or 15.8+/-11% (standard error of the estimate=0.7). Both histomorphometry and IVUS showed that IH was concentric and uniformly distributed over the length of the stent. Intravascular ultrasound detected neointimal thickening of < or =0.2 mm in 5 of 16 stents. Sample size calculations based on the IVUS measurement of IH volumes showed that 12 stented lesions/arm would be required to show a 50% reduction in IVUS-measured IH volume and 44 stented lesions/arm would be required to show a 25% reduction in IH volume. CONCLUSION: In vivo IVUS measurement of IH volumes correlated strongly with ex vivo histomorphometry. Using volumetric IVUS end points, small sample sizes should be necessary to demonstrate effectiveness of strategies to reduce in-stent restenosis.  相似文献   

19.
This study compares the immediate and long-term outcomes of a primary coronary stenting strategy with primary balloon angioplasty with stent bailout in the treatment of patients with acute myocardial infarction (AMI). One hundred forty-seven consecutive patients who underwent primary balloon angioplasty with stent bailout (n = 94) or primary stenting (n = 53) for AMI were clinically followed for 8.1 +/- 5.7 and 8.5 +/- 4.5 months, respectively. Immediate results, as well as in-hospital and long-term ischemic events (death, reinfarction, and repeat revascularization) were compared between both groups. Angiographic success was 91.5% in the balloon angioplasty group and 94% in the stent group. In-hospital and late follow-up combined ischemic events were 22 of 94 (23%) versus 0 of 53 (0%); p < 0.001 and 33 of 78 (42%) versus 13 of 53 (25%), p = 0.04 for the balloon angioplasty and stent groups, respectively. At 6 months, the cumulative probability of repeat target lesion revascularization was higher in the balloon angioplasty group (47% vs 18%, p = 0.0006) as was the probability of late target revascularization (36% vs 18%, p = 0.046); the cumulative event-free survival after 6 months was significantly lower in the balloon angioplasty group (44% vs 80%, p = 0.0001). This study demonstrates that a primary stent placement strategy in patients with AMI is safe, feasible, and superior to primary balloon angioplasty with stent bailout. Primary stenting results in a larger postprocedural minimal luminal diameter, a lower early and late recurrent ischemic event rate, and a lower incidence of target lesion revascularization at follow-up.  相似文献   

20.
Strategies for dilatation of bifurcation stenoses have continued to evolve over the past several years. However, there is limited experience on the efficacy of various nonballoon interventional devices and their results in comparison with balloon angioplasty. We, therefore, analysed our data in 72 patients of coronary artery disease with true bifurcation stenoses with balloon angioplasty or new device interventions (NDI). All patients underwent dilatation of both the primary vessel and side branch ostial stenosis. Balloon angioplasty using double guidewire with sequential or simultaneous (kissing balloon) balloon inflation in the two vessels was performed in 42 patients. Thirty patients underwent NDI, using directional coronary atherectomy (DCA) in 12, rotablation in 6 and elective coronary stents in 12 patients. There were no significant differences in the baseline clinical and angiographic variables between patients in the two groups. While the preprocedural luminal diameter stenosis was similar, the residual stenosis was significantly less, both in the primary vessel and side branch, after NDI compared to balloon angioplasty. The procedure was successful in 96.6 percent patients treated with NDI and 83.3 percent with balloon angioplasty (p < 0.01) with relief of obstruction in both branches without any major complications. Freedom from subsequent coronary events in the form of angina, myocardial infarction, PTCA, bypass graft surgery of death was significantly more, both at 6 months (92% versus 65.6%, p < 0.001) and 12 months (81.8% versus 53.1%, p < 0.001) in the group of patients treated with NDI compared to balloon angioplasty. It is, therefore, concluded that NDI including DCA, rotablation and elective stenting are associated with higher rate of success, lesser complications and better event-free survival in comparison to balloon angioplasty for treatment of true bifurcation stenoses.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号