首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The objectives of the present research are to accurately measure bottom shear stress under high-velocity flow conditions. To achieve high-velocity flow conditions, a laboratory-scale flume has been specially built in which flow velocity can reach over 3 m s1. Also an instrument that can directly measure bottom shear stress has been developed and validated. Then, the flow resistance has been estimated by simultaneously measuring flow velocity and bottom shear stress. It appears that the shear stress is indeed proportional to velocity squared and also to Reynolds number. On the other hand, Manning's n value and the skin friction factor are more or less uniform across all experimental cases.  相似文献   

2.
Dye tracer technique is a successful tool for measuring liquid flow in closed conduits and open channels. The technique is based on the continuous injection of a tracer into the flow and on the measurement of the dilution ratio. As one of the requirements, the tracer injection rate must be known and well controlled. A device was designed to obtain this control. Such device implements a volumetric flow measurement technique and provides accurate digital display readout. Experimental results indicate that the apparatus can be used to measure the injection flow rate in a range from 235 to 2000 ml min−1 with a relative error smaller than 1.5% of the reading. Even with these low injection flow, the dilution method can be applied to determine the much higher flow rates typically found in domestic or industrial outfalls as well as in artificial or natural channels. This paper also presents an application of the dilution method to flow rate measurement of an industrial outfall and the uncertainty analysis associated with the obtained values. The results indicate that the main errors of discharge estimation can arise from non-steady state flow conditions, incomplete tracer mixing, uncertainty of tracer concentration and tracer injection rate measurements.  相似文献   

3.
Within the framework of a research project regarding investigations on a high-pressure Coriolis mass flow meter (CMF) a portable flow test rig for traceable calibration measurements of the flow rate (mass - and volume flow) in a range of 5 g min−1 to 500 g min−1 and in a pressure range of 0.1 MPa to 85 MPa was developed. The measurement principle of the flow test rig is based on the gravimetrical measuring procedure with flying-start-and-stop operating mode. Particular attention has been paid to the challenges of temperature stability during the measurements since the temperature has a direct influence on the viscosity and flow rate of the test medium. For that reason the pipes on the high-pressure side are double-walled and insulated and the device under test (DUT) has an enclosure with a separate temperature control. From the analysis of the first measurement with tap water at a temperature of 20 °C and a pressure of 82.7 MPa an extensive uncertainty analysis has been carried out. It was found that the diverter (mainly due to its asymmetric behaviour) is the largest influence factor on the total uncertainty budget. After a number of improvements, especially concerning the diverter, the flow test rig has currently an expanded measurement uncertainty of around 1.0% in the lower flow rate range (25 g min−1) and 0.25% in the higher flow rate range (400 g min−1) for the measurement of mass flow. Additional calibration measurements with the new, redesigned flow test rig and highly viscous base oils also indicated a good agreement with the theoretical behaviour of the flow meter according to the manufacturers׳ specifications with water as test medium. Further improvements are envisaged in the future in order to focus also on other areas of interest.  相似文献   

4.
《Wear》2007,262(7-8):826-832
The non-lubricated, sliding friction and wear behavior of Ti3Si(Al)C2 and SiC-reinforced Ti3Si(Al)C2 composites against AISI 52100 bearing steel ball were investigated using a ball-on-flat, reciprocating tribometer at room temperature. The contact load was varied from 5 to 20 N. For monolithic Ti3Si(Al)C2, high friction coefficients between 0.61 and 0.90 and wear rates between 1.79 × 10−3 and 2.68 × 10−3 mm3 (N m)−1 were measured. With increasing SiC content in the composites, both the friction coefficients and the wear rates were significantly decreased. The friction coefficients reduced to a value between 0.38 and 0.50, and the wear rates to between 2.64 × 10−4 and 1.93 × 10−5 mm3 (N m)−1 when the SiC content ranged from 10 to 30 vol.%. The enhanced wear resistance of Ti3Si(Al)C2 is mainly attributed to the facts that the hard SiC particles inhibit the plastic deformation and fracture of the soft matrix, the oxide debris lubricate the counterpair, and the wear mode converts from adhesive wear to abrasive wear during dry sliding.  相似文献   

5.
The use of portable short-throat flume in the field is an emerging technique developed for water discharges measurement of inlet in the field. Based on the principle of critical flow and RNG kε three-dimensional turbulence model along with the TruVOF technique, experiments and corresponding simulations were performed for 16 working conditions on the 76 mm width flume with discharges up to 40.01 L/s to determine its hydraulic performance. Hydraulic performance of the flume obtained from simulation analyses were later compared with observed results based on time-averaged flow field, flow pattern, Froude number and velocity distribution. Comparison yielded a solid agreement between results from two methods with relative error below ±10%. Regression models developed for upstream depth versus discharge under different working conditions were satisfying with the relative error of 9.16%, which met the common requirements of flow measurement in irrigation areas. Compared to the long-throat flume, head loss of portable short-throat flume in the field was significantly less. Further, head loss under the free flow condition was less than that under the submerged flow condition of portable short-throat flume with a flat base in the field.  相似文献   

6.
This paper presents the design and calibration of an ISO non-compliant orifice plate flowmeter whose intended use is for respiratory function measurements in the bidirectional air flow range ±9 L/min.The novelty of the proposed sensor consists of a plate beveled in both upstream and downstream sides: a symmetrical geometry is adopted in order to perform bidirectional measurements of flow rate. A mathematical model is introduced to quantify the influence of temperature on the sensor output. Four different positions of the pressure static taps are evaluated in order to maximize bidirectionality. An index is also introduced in order to quantitatively estimate the anti-symmetry of the sensor's response curve.Trials are carried out to evaluate the influence on sensor output of air temperatures (22 °C, 30 °C and 37 °C) at different values of relative humidity (5%, 55% and 85%). Experimental data show a quite good agreement with the theoretical model (R2>0.98 in each condition).The influence of air temperature on the sensor output is minimized by introducing a correction factor based on the theoretical model leading to measurement repeatability better than 2% in overall range of calibration. The mean sensitivity in the calibration range is about 2 kPa L−1·min allowing to obtain a sensor discrimination threshold lower than 0.2 L/min in both directions. The time constant of the whole measurement system, equal to 2.40±0.03 ms, leads to a bandwidth up to 80 Hz making the sensor suitable for respiratory function measurements.  相似文献   

7.
The paper describes a large load squeeze film damper (SFD) test rig, details measurements of dynamic loads inducing circular orbits conducted on a large clearance (c=0.250 mm) open ends centrally grooved SFD, and presents the identified experimental SFD force coefficients for operation at three static eccentricities. The rig has a bearing cartridge supported atop four elastic rods and a stationary journal, 0.127 mm in diameter. The damper consists of two parallel film lands, 12.7 mm in length, separated by a central groove, 6.35 mm 9.5 mm in depth. In the journal, three equally spaced holes, 120° apart, supply a light lubricant into the central groove and squeeze film lands. The experimental SFD force coefficients are compared to test results obtained earlier for a damper with the same film land lengths but with a smaller clearance (c=0.140 mm) and against predictions obtained from an advanced physical model that accounts for the flow field in the central groove and the interaction with the adjacent film lands. Dynamic pressures in the film lands and in the central groove are (not) surprisingly of the same order of magnitude. The central groove affects the dynamic forced response of the test damper to generate large direct damping coefficients, ~3.5 times those derived from classical lubrication formulas. Experimental added mass coefficients are ~7.4 times the predictive classical values. Predictions from an advanced model correlate well with the test data when using a shallow groove depth. The measurements and analysis advance knowledge on the dynamic forced performance of SFDs, point out to the limited value of simplistic predictive formulas, and validate the accuracy of a modern predictive tool.  相似文献   

8.
We describe a flow standard for gas flows in the range from 0.01 sccm to 100 sccm with a relative standard uncertainty (68% confidence) of 0.03% at 1 sccm (1 sccm≡1 cm3/min of an ideal gas at 101325 Pa and 0 °C ≈ 0.74358 μmol/s). The flow standard calibrates a secondary meter by withdrawing a piston from a cylinder held at constant pressure P while gas flows from the secondary meter into the cylinder. The flow standard can operate anywhere in the range 10 kPa<P<300 kPa, and it can act as a flow source as well as a flow receiver. The flow standard incorporated features that improved its convenience and lowered its cost without sacrificing accuracy, specifically (1) dry sliding seals made with commercially available, easily replaced, o-rings, (2) a compact design based on a commercially available, hollow piston, and (3) a linear encoder with a small Abbe error.  相似文献   

9.
The objective of this study was to develop a reliable method for the determination of the thermal conductivity of composted material using the TP08 probe. Study was set out to determine whether the selection of a signal fragment used to establish thermal conductivity (λ), has a significant influence on the results. Also minimum number of measurements was determined for every phase of the composting process. No significant differences were reported between results, but certain changes in the value of λ were noted. In successive stages of the process, thermal conductivity of composted material were: 0.31 ± 0.09, 0.45 ± 0.14, 0.27 ± 0.03 and 0.37 ± 0.17 W m−1 K−1.  相似文献   

10.
A new approach is proposed to improve a graphical approach with considering intensity coupling loss coefficients in the analytical derivation of the optical transfer functions for a symmetric double stage vertically coupled microring resonator. An optimum transmission coupling condition is determined with considering terms of couplers intensity loss which leads to low insertion loss of 1.2 dB, finesse of 1525, the out of band rejection ratio of 61.8 dB. The resonating system is used as an optical force sensing system to make the benefit of the accuracy of measurements in micro and nano scales. The sensitivity of proposed force sensor in terms of wavelength-shift is 33 nm/nN and the limit of detection is 1.6 × 10−2 nN. The proposed sensing system has the advantages of self-calibration and the low power consumption due to the low intensity.  相似文献   

11.
An automated, miniature, S-type Pitot tube system was created to obtain fluid velocity profiles at low flows in equipment having limited optical access, which prevents the use of standard imaging techniques. Calibration of this non-standard Pitot tube at small differential pressures with a custom, low-pressure system is also described. Application of this system to a vertical, high-pressure, water tunnel facility (HWTF) is presented. The HWTF uses static flow conditioning elements to stabilize individual gaseous, liquid, or solid particles with water for optical viewing. Stabilization of these particles in the viewing section of the HWTF requires a specific flow field, created by a combination of a radially expanding test section and a special flow conditioner located upstream of the test section. Analysis of the conditioned flow field in the viewing section of the HWTF required measurements across its diameter at three locations at 1 mm spatial resolution. The custom S-type Pitot tube system resolved pressure differences of <100 Pa created by water flowing at 5–30 cm/s while providing a relatively low response time of ~300 s despite the small diameter (<1 mm) and long length (340 mm) of the Pitot tube needed to fit the HWTF geometry. Particle imaging velocimetry measurements in the central, viewable part of the HWTF confirmed the Pitot tube measurements in this region.  相似文献   

12.
In the framework of the ongoing EMPIR JRP 16ENG01 “Metrology for Hydrogen Vehicles” a main task is to investigate the influence of pressure on the measurement accuracy of Coriolis Mass Flow Meters (CFM) used at Hydrogen Refueling Stations (HRS). At a HRS hydrogen is transferred at very high and changing pressures with simultaneously varying flow rates and temperatures. It is clearly very difficult for CFMs to achieve the current legal requirements with respect to mass flow measurement accuracy at these measurement conditions. As a result of the very dynamic filling process it was observed that the accuracy of mass flow measurement at different pressure ranges is not sufficient. At higher pressures it was found that particularly short refueling times cause significant measurement deviations. On this background it may be concluded that pressure has a great impact on the accuracy of mass flow measurement. To gain a deeper understanding of this matter RISE has built a unique high-pressure test facility. With the aid of this newly developed test rig it is possible to calibrate CFMs over a wide pressure and flow range with water or base oils as test medium. The test rig allows calibration measurements under the conditions prevailing at a 70 MPa HRS regarding mass flows (up to 3.6 kg min−1) and pressures (up to 87.5 MPa).  相似文献   

13.
14.
A portable device for calibration of trace humidity sensors and an adopted calibration procedure have been developed. The calibration device is based on humidity generation by permeating water through polymeric membrane tubes. Water vapour transmission rates for various polymers were experimentally determined in order to select the most suitable polymeric material. The developed trace humidity generator consists of a gas-flow polymeric hose immersed in a water reservoir thermostated by a sensor-controlled heater. Mole fractions of water vapour between 1 μmol mol−1 and 350 μmol mol−1 (equivalent to frost-point temperatures from −76 °C to −31 °C) were generated by varying either the operating temperature or gas flow. The operating temperature can be varied from 20 °C to 60 °C and kept stable within 0.1 K. Uncertainty analysis indicated that the trace humidity generator produces gas flows of constant humidity amounts with a relative expanded uncertainty less than 3.4% (k = 2) of the generated value.  相似文献   

15.
Oil-in-water two-phase flows are often encountered in the upstream petroleum industry. The measurement of phase flow rates is of particular importance for managing oil production and water disposal and/or water reinjection. The complexity of oil-in-water flow structures creates a challenge to flow measurement. This paper proposes a new method of two-phase flow metering, which is based on the use of dual-modality system and multidimensional data fusion. The Electrical Resistance Tomography system (ERT) is used in combination with a commercial off-the-shelf Electromagnetic Flow meter (EMF) to measure the volumetric flow rate of each constituent phase. The water flow rate is determined from the EMF with an input of the mean oil-fraction measured by the ERT. The dispersed oil-phase flow rate is determined from the mean oil-fraction and the mean oil velocity measured by the ERT cross-correlation velocity profiling. Experiments were carried out on a vertical upward oil-in-water pipe flow, 50 mm inner-diameter test section, at different total liquid flow rates covering the range of 8–16 m3/hr. The oil and water flow rate measurements obtained from the ERT and the EMF are compared to their respective references. The accuracy of these measurements is discussed and the capability of the measurement system is assessed.  相似文献   

16.
Two miniaturized liquid film sensors (MLFS) based on electrical conductance measurement have been developed and tested. The sensors are non-intrusive and produced with materials and technologies fully compatible and integrable with standard microfluidics. They consist of a line of 20 electrodes with a purpose-designed shape, flush against the wall, covering a total length of 5.00 and 6.68 mm. The governing electronics achieve 10 kHz of time resolution. The electrode spacing of the two sensors is 230 μm and 330 μm, which allows measurements of liquid films up to 150 μm and 400 μm for sensors MLFSA and MLFSB, respectively. The sensor characteristics were obtained by imposing static liquid films of known thickness on top of the actual sensor. Further dynamic measurements of concurrent air-water flow in a horizontal microchannel were performed. The line of electrodes is placed across the flow direction with an angle of 3.53° from the direction of flow, allowing for a spatial resolution perpendicular to the flow of 14.2 μm for sensor MLFSA and 20.5 μm for sensor MLFSB. The high time and spatial resolution allows for fast and accurate detection of the presence of bubbles, and even measurement of film thickness and bubble velocity. Further information, such as the bubble shape, can be gathered based on the shape of the liquid layer underneath the bubble, which is particularly important for heat transfer studies in microchannels.  相似文献   

17.
Combination of different extraction methods is an interesting work in the field of sample pretreatment. In the current study, for the first time, solid phase extraction combined with solvent-based de-emulsification dispersive liquid–liquid microextraction (SPE-SD-DLLME) was developed for preconcentration and trace detection of cadmium in water samples using flame atomic absorption spectrophotometry (FAAS). The adsorbed cadmium ions on prepared SPE (75 mL of aqueous solution) were eluted by optimized elution solvent and introduced to the second microextraction step. The effective variables of SPE including the pH of sample, flow rates, type, concentration and volume of the eluent and the effect of potentially interfering ions of the separation of cadmium were evaluated and optimized. Also, several factors that influence the SD-DLLME step such as pH, neocuproine concentration (the cadmium binding ligand), type of dispersed/de-emulsifier solvent, volume of disperser/de-emulsifier solvent and type and volume of extraction solvents were investigated. SPE-SD-DLLME provides a preconcentration factor of 165 for cadmium ions. Calibration plot was linear in the range of 0.1–50 μg L−1 with correlation of determination (r2) of 0.988. The precision and limit of detection of proposed method were 5.1% (RSD%, n = 8) and 0.03 μg L−1, respectively.  相似文献   

18.
Reverse saturation current and the ideality factor (η) are the main parameters that affect the performance of a radiation semiconductor detector in different space environmental conditions. We have measured both of these parameters for the Silicon Drift Detector (SDD) used as a radiation detector in the X-ray spectrometry for space borne applications having the active area of 40 mm2 and 109 mm2 with 450 μm thick silicon. The measured reverse saturation current is compared with the theoretically estimated values using diode equation for various detector operating temperatures and shown that there is a strong dependence of reverse saturation current with ideality factor. Subsequently, using the reverse saturation current ratio method, the slope ratio for small area to the large area SDD is derived and compared with the theoretical slope ratio obtained using the measured ideality factor. It is shown that the slope ratios closely match with the diode equation of the form which has the ideality factor in both the product and exponential terms for these SDDs. The measured spectral energy resolution is ∼150 eV at 5.9 keV for both small and large area SDDs when operated at −40 °C and −65 °C respectively. The noise performance of the spectrometer is also measured in terms of Equivalent Noise Charge (ENC) for various detector operating temperatures and shown that the value of ENC in rms noise electrons is minimal for the pulse shaping time of 3.3 μs.  相似文献   

19.
《Tribology International》2012,45(12):1902-1919
Wear variations of Nimonic 80A slid against Incoloy 800HT between room temperature (RT) and 750 °C, and sliding speeds of 0.314 and 0.905 m s−1 were investigated using a ‘reciprocating-block-on-cylinder’, low debris retention configuration. These were considered alongside previous observations at 0.654 m s−1.Different wear types occurring were mapped, including high transfer ‘severe wear’ (RT and 270 °C, also 0.905 m s−1 at ≤570°C), low transfer ‘severe wear’ (0.314 m s−1 at 390 °C to 510 °C oxide abrasion assisted at 510 °C), and ‘mild wear’ (0.314 m s−1 at ≥570 °C; 0.905 m s−1 at ≥630 °C). Wear surfaces at 750 °C were cross-sectioned and profiled.  相似文献   

20.
New K+ ion-conducting polymer blend electrolyte films based on amorphous polymer poly(vinyl chloride) (PVC) and semicrystalline polymer poly(ethylene oxide) (PEO) complexed with KCl salt were prepared using a solution-cast technique. The maximum value of ionic conductivity of a PVC/PEO:KCl (42.5:42.5:15) system is 8.29 × 10−6 S/cm at 303 K. The absorption edge was found at 4.30 eV for undoped film, while it was observed at 4.03 and 3.93 eV for 10 and 15 wt% KCl doped films, respectively. The direct band gaps for these pure and salt doped PVC/PEO films were found to 4.10, 3.86 and 3.74 eV, respectively, whereas the indirect band gaps were determined as 4.15, 3.72 and 3.64 eV. Transference number values showed that the charge transport in this electrolyte system is predominantly due to ions (tion = 0.97). The discharge capacity for PVC/PEO:KCl (42.5:42.5:15) polymer blend electrolyte system is 11 μA/h.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号