共查询到18条相似文献,搜索用时 93 毫秒
1.
2.
3.
4.
采用固相萃取-高效液相色谱法对保健品中的枸橼酸西地那非进行测定。样品经Strata X-C固相萃取小柱净化,用Phenomenex Kinetex C18柱分离,乙腈-10mM醋酸铵(V/V=35/65)为流动相,经液相色谱检测。结果表明,枸橼酸西地那非在0.5~80μg/mL的浓度范围之间具有良好的线性关系(R2=0.9995),加标回收率大于90%。该方法简单,快速,精密度和准确度高,适用于保健品中枸橼酸西地那非的测定。 相似文献
5.
建立了固相萃取-离子对色谱法测定酱油与黄豆酱中的三聚氰胺。样品经甲醇提取,WatersMCX固相萃取柱净化。分析时用InertsillODS-SPC18色谱柱(5μm,4.6×250mm)分离。水(缓冲液:0.01moL/L柠檬酸+0.01moL/L辛烷磺酸钠,pH=3.0)∶乙腈=92∶8(V/V)溶液为流动相,流速1.0mL/min,在紫外波长240nm下检测。三聚氰胺在0.02~2.00mg/L的范围内,有良好的线性关系(r2=0.9999),方法检出限为1.0mg/kg,加标回收率在83.5%~109.3%范围内,相对标准偏差小于5.0%。 相似文献
6.
建立了用离子色谱同时测定茶叶中的F~-、Cl~-、NO_2~-、NO_3~-、SO_4~(2-)5种重要阴离子的分析方法。以Ionpac AS11为分离柱、AG11为保护柱、NaOH等浓度洗脱,以普洱绿茶为样品,考察了不同的回流时间,提取液体积,筛目大小对茶叶提取率的影响,其他3种茶叶作为推广。结果表明:该方法回归方程的线性相关系数在0.999 1~0.999 8之间,各组分的检出限在0.015mg/L~0.041 mg/L之间,RSD值5%,加标回收率在80.6%~113.7%之间。该方法具有快速、灵敏、准确的特点,用于实际茶叶样品中阴离子的分析,结果令人满意。 相似文献
7.
建立了固相萃取-离子对色谱法测定酱油与黄豆酱中的三聚氰胺。样品经甲醇提取,WatersMCX固相萃取柱净化。分析时用InertsillODS-SPC18色谱柱(5μm,4.6×250mm)分离。水(缓冲液:0.01moL/L柠檬酸+0.01moL/L辛烷磺酸钠,pH=3.0)∶乙腈=92∶8(V/V)溶液为流动相,流速1.0mL/min,在紫外波长240nm下检测。三聚氰胺在0.02~2.00mg/L的范围内,有良好的线性关系(r2=0.9999),方法检出限为1.0mg/kg,加标回收率在83.5%~109.3%范围内,相对标准偏差小于5.0%。 相似文献
8.
9.
通过一步聚合法制备以双氰胺为模板分子,甲基丙烯酸为功能单体,乙二醇二甲基丙烯酸为交联剂,偶氮二异丁腈为引发剂的分子印迹聚合物。通过扫描电子显微镜、红外光谱、紫外光谱等对材料的物理及化学性能进行表征。采用分子印迹固相萃取结合高效液相色谱法检测实际奶粉样品中的双氰胺残留。该方法的线性范围为0.01~2.00 mg/L,线性相关系数R~2为0.999 4,呈现良好的线性关系,检出限(R_(SN)=3)为0.57×10~(-2) mg/L,样品加标回收率为102.5%~104%,相对标准偏差在0.21%~0.86%之间。 相似文献
10.
11.
A simple and rapid high-performance liquid chromatography (HPLC) procedure for the analysis of melamine in liquid milk and milk powder has been developed. Decrease of acetonitrile percentage and phosphate buffer concentration in mobile phase, and lowering of buffer pH and column temperature would benefit the retention of melamine on titania. Taking advantage of the ligand-exchange and hydrophilic interaction mixed retention mode on bare titania column, neither complex pretreatment nor ion-pair reagent was required. The whole analysis for one sample including sample pretreatment and HPLC analysis could be accomplished within 30 min. The method presented good linearity (R 2 = 0.9998) in a wide range of 0.02–10 μg mL−1. The limit of detection (3σ) and limit of quantification (10σ) of the method were 6 and 20 μg L−1, respectively, which were equivalent to 15 and 50 μg kg−1 melamine in liquid milk, 60 and 200 μg kg−1 melamine in milk powder, respectively. Such sensitivity could be compared with those obtained by HPLC with solid-phase extraction or HPLC coupled with tandem mass spectrometry and was adequate for the screening of melamine in tainted dairy products. The repeatability (RSDs) of the retention times and peak areas of 11 replicate detections of 1.0 μg mL−1 melamine were 0.32% and 2.5%, respectively. The intermediate precision on three consecutive days (RSDs, n = 6) of the retention times and peak areas were 1.1% and 2.3%, respectively. The recovery of spiked melamine in dairy samples ranged from 95.2% to 105%. The simplicity, sensitivity and rapidity of the proposed method make it an effective alternative detecting technique for melamine. 相似文献
12.
13.
用Venusil ASB-C18(4.6×250mm,5μm)色谱柱,流动相为庚烷基磺酸钠:乙腈(pH3.2)=90:10(体积比),流速为1.0mL/min.检测波长240 nm的色谱条件下,经提取处理并经混合型阳离子交换柱固相萃取净化,对肉及肉制品中的三聚氰胺残留进行测定,结果表明在0.5μg~100.0μ之间有较好的线性关系,r=0.9996.回收率在87%~94%,RSD为3.8%~4.2%(n=6). 相似文献
14.
以石墨烯为吸附剂制备固相萃取柱,建立固相萃取-高效液相色谱法检测6种磺胺类药物的方法。采用紫外检测器进行定性和定量分析,检测波长为270nm。对包括吸附剂的种类、洗脱剂的种类和用量、样品溶液的pH值和样品体积等参数进行详细优化。在优化条件下,6种磺胺类药物在0.1~100μg/L范围内与峰面积呈良好的线性关系,相关系数为0.990~0.997。检出限(RSN=3)为6.3~21.1ng/L。方法的精密度为2.12%~4.75%。将该方法用于蔬菜样品分析,回收率为79.3%~104.2%。 相似文献
15.
16.
17.
高效液相色谱法测定乳与乳制品中的三聚氰胺 总被引:5,自引:0,他引:5
目的建立乳与乳制品中三聚氰胺的测定方法。方法样品用0.1 mol/L的盐酸提取,再用60 g/L的磺基水杨酸沉淀蛋白。缓冲液为10 mmol/L柠檬酸与10 mmol/L辛烷磺酸钠混合溶液,以缓冲液 乙腈(85 15,体积比)为流动相,使用Kromasil KR100-5C8柱,配备有二极管阵列检测器的高效液相色谱仪在200~400 nm范围内对待测组分进行分离和测定。结果样品中三聚氰胺的添加回收率在80%~105%之间,相对标准偏差(RSD,n=6)小于5.24%,方法的定量限为1.0 mg/kg。结论该方法快速、准确,操作简便,能够满足乳与乳制品中三聚氰胺的分析要求。 相似文献
18.
固相萃取-高效液相色谱法测定白砂糖中丙烯酰胺 总被引:1,自引:1,他引:1
建立了固相萃取-高效液相色谱法测定白砂糖中丙烯酰胺助剂残留的方法。采用Oasis HLB和Ac- cBond ODS-C_(18)固相萃取柱对样品进行净化,在Spherisorb NH_2柱上以乙腈-水(体积比为75:25)为流动相进行分离,流速0.8mL/min,柱温25℃,检测波长200nm,对白砂糖中丙烯酰胺助剂残留进行了测定。方法的线性范围为25~1000μg/L,线性相关系数为0.9992。方法的检出限为6μg/L,低、中、高3个浓度水平的加标回收率为90.2%~93.8%,相对标准偏差<5.5%。该法用于白砂糖中丙烯酰胺的测定,结果令人满意。 相似文献