首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
PurposeThe aim of this cross-over study was to investigate the changes in corneal thickness, anterior and posterior corneal topography, corneal refractive power and ocular wavefront aberrations, following the short term use of rigid contact lenses.MethodFourteen participants wore 4 different types of contact lenses (RGP lenses of 9.5 mm and 10.5 mm diameter, and for comparison a PMMA lens of 9.5 mm diameter and a soft silicone hydrogel lens) on 4 different days for a period of 8 h on each day. Measures were collected before and after contact lens wear and additionally on a baseline day.ResultsAnterior corneal curvature generally showed a flattening with both of the RGP lenses and a steepening with the PMMA lens. A significant negative correlation was found between the change in corneal swelling and central and peripheral posterior corneal curvature (all p  0.001). RGP contact lenses caused a significant decrease in corneal refractive power (hyperopic shift) of approximately 0.5 D. The PMMA contact lenses caused the greatest corneal swelling in both the central (27.92 ± 15.49 μm, p < 0.001) and peripheral (17.78 ± 12.11 μm, p = 0.001) corneal regions, a significant flattening of the posterior cornea and an increase in ocular aberrations (all p  0.05).ConclusionThe corneal swelling associated with RGP lenses was relatively minor, but there was slight central corneal flattening and a clinically significant hyperopic change in corneal refractive power after the first day of lens wear. The PMMA contact lenses resulted in significant corneal swelling and reduced optical performance of the cornea.  相似文献   

2.
PurposeTo investigate the rate of progression of keratoconus in patients wearing pancorneal toric edge rigid gas-permeable contact lenses (pancorneal RGP-CL) compared to non-pancorneal RGP-CL. We also evaluated alterations in anterior chamber parameters with the progression of keratoconus and investigated the location of the cone in eyes with keratoconus.MethodsThe current study was a retrospective study including patients with clinically evident keratoconus from the outpatient clinic from the Department of Ophthalmology of the Erasmus Medical Center, Rotterdam, the Netherlands. Medical history and contact lens characteristics were documented. All participants underwent ophthalmic examination including corneal topography. Corneal topography was repeated at one of the consecutive visits of the patient. Patients were divided into two groups: those wearing pancorneal RGP-CL and those wearing other contact lens types. As a measure of progression of keratoconus differences in corneal topography parameters between both groups were compared.ResultsA total of 82 patients were included of which 42 had follow-up (mean 17.8 months) data. We found a significant difference in progression between eyes fitted with and without pancorneal RGP-CL (K-flat: p = 0.09, K-steep: p = 0.02, K-mean: p = 0.02, and K-minimum: p = 0.04). Compared with eyes fitted without pancorneal RGP-CL no significant difference in K-values was found for eyes fitted with pancorneal RGP-CL during follow-up. Furthermore, a significant decrease in anterior chamber volume (p < 0.001) and corneal volume (p = 0.008) was found during follow-up. In 86.6% the location of the cone was located infero-temporal.ConclusionsPancorneal RGP-CL have a better effect on stabilizing progression of keratoconus than non-pancorneal RGP-CL. The finding of an infero-temporal location of the cone in keratoconic corneas may improve results of contact lens fitting and surgical management.  相似文献   

3.
PurposeTo evaluate the impact of differente soft contact lens power in the anterior corneal curvature and regularity in subjects with keratoconus.MethodsNineteen subjects (30 eyes) with keratoconus were included in the study. Six corneal topographies were taken with Pentacam Eye System over the naked eye and successively with soft lens (Senofilcon A) powers of −3.00, −1.50, 0.00, +1.50 and +3.00 D. Corneal measurements of mean central keratometry (MCK), maximum tangential curvature (TK), maximum front elevation (MFE) and eccentricity (Ecc) at 6 and 8 mm diameters as well as anterior corneal surface high order aberrations (i.e. total RMS, spherical- and coma-like and secondary astigmatism) were evaluated.ResultsNegative- and plano-powered soft lenses flattened (p < 0.05 in all cases), whereas positive-powered lenses did not induce any significant changes (p > 0.05 in all cases) in MCK in comparison to the naked eye. The TK power decreased with negative lenses (p < 0.05 in both cases) and increased with +3.00 D lenses (p = 0.03) in comparison to the naked eye. No statistically significant differences were found in MFE with any soft lens power in comparison to the naked eye (p > 0.05 in all cases). Corneal eccentricity increased at 8 mm diameter for all lens powers (p < 0.05 in all cases). No statistically differences were found in HOA RMS and spherical-like aberration (both p > 0.05). Statistically differences were found in coma-like and secondary astigmatism (both p < 0.05).ConclusionNegative-powered soft contact lenses provide a flatter anterior surface in comparison to positive-powered lenses in subjects with keratoconus and thus they might be more suitable for piggyback contact lens fitting.  相似文献   

4.
PurposeTo assess and compare the base curve (BC) of rigid gas permeable contact lens (RGP) that were calculated by FITSCAN using corneal topography (Orbscan IIz) and the diagnostic contact lens fitting method in keratoconus eyes.Materials and methodsA prospective comparative study of 85 keratoconus eyes was conducted. Two masked observers calculated the contact lens parameters of RGP lens by diagnostic fitting method and using FITSCAN technology. The base curves calculated by two methods were compared using Wilcoxon signed rank test and agreement between two methods were analysed using Bland–Altman plot.ResultsEighty-five eyes from 55 keratoconus patients were included in the study. The mean age was 17.63 ± 2.78 (range: 12–23) years and among them 46 were males. The keratoconus was graded into mild, moderate and severe based on average keratometry values. The base curve calculated by the FITSCAN is on average 0.22 mm higher than that calculated by diagnostic method (P value <0.0001, 95% CI = 0.155, 0.245, Wilcoxon signed rank test) and the bias between the two methods was found to be 2.7% (Bland–Altman plot), indicating systematic bias between the two modalities. By single linear regression analysis, the base curve of RGP contact lens could calculated by using the formula, base curve (BC) = (FITSCAN calculated BC × 0.86563) + 0.78738.ConclusionOur study showed that selecting the BC of the initial trial lens 0.22 mm steeper than the FITSCAN calculated base curve, may help to reduce the complexity of RGP contact lens fitting in keratoconus.  相似文献   

5.
ObjectiveTo evaluate the efficacy of contact lenses in visual rehabilitation of a series of patients with corneal scars/opacities.MethodRetrospective review of case records of 158 patients (n = 162 eyes) with poor vision subsequent to corneal scar/opacity, who underwent contact lens fitting, was done. Primary outcome assessed was quantum of additional improvement in vision with rigid gas permeable (RGP) or soft lenses over spectacles. Success was defined as visual improvement of ≥2 lines over that of spectacles and/or improvement of vision to ≥20/60 (LogMAR 0.48).ResultsRigid gas permeable lenses were fitted in 137 eyes and soft contact lenses in 25 eyes. Lenses were successful in improving visual acuity by two or more lines over that of spectacles in 70% eyes (113 of 162 eyes), of which RGP lens accounted for 85% (96 of 113 eyes). Alternative outcome of success was defined as attainment of reasonable functional vision of >20/60 (LogMAR 0.48). This could be achieved in 65% cases (105 of 162 eyes) of which 83% (88 eyes) were with use of RGP lenses. Almost one-fourth (23.4%) patients were children less than 15 years old. Soft contact lenses were attempted in 25 instances, where RGP lens could not be fitted and were successful in 17 (68%) of these. All these 17 patients were aphakes.ConclusionsRehabilitation of corneas with visually disabling corneal opacities is possible with usage of appropriate contact lenses even in young children.  相似文献   

6.
PurposeTo investigate the efficacy of spherical aberration (SA) correction with aspheric contact lenses (aspheric lenses) based on lens power, and compare the results with those of spherical contact lenses (spherical lenses).MethodsOcular higher-order aberrations were measured with a wavefront sensor, in 11 myopic subjects wearing an aspheric lens (Medalist Fresh fit (PUREVISION 2 HD); Bausch + Lomb) or a spherical lens (ACUVUE Oasys; Johnson & Johnson). Six different lens powers (−7.00 diopters (D), −5.00 D, −3.00 D, −1.00 D, +1.00 D, +3.00 D) were used for all subjects. The amount of SA correction from the contact lens at each power was calculated as the difference between SA with the contact lens on-eye and SA of the eye alone.ResultsFor the spherical lenses, SA correction was close to 0.00 μm for the +1.00 D lens, became more positive as the labeled lens power increased and became more negative as the labeled lens power decreased. For the aspheric lenses, SA correction was consistent, from −0.15 to −0.05 μm, for all lens powers except for the −1.00 D lens. SA correction for the spherical and aspheric lenses was significantly different at −7.00 D (p = 0.040), −3.00 D (p = 0.015), −1.00 D (p < 0.001), +1.00 D (p = 0.006), and +3.00 D (p < 0.001) powers.ConclusionAn aspheric lens is capable of correcting SA at different lens powers, and has SA correction in the range of −0.15 to −0.05 μm over a 6 mm aperture.  相似文献   

7.
PurposeTo assess the corneal endothelial cell density (ECD) in keratoconus patients with no history of contact lens use.SettingYuzuncu Yil University, School of Medicine and Van Training and Research Hospital, Department of Ophthalmology, Van, Turkey.DesignCross-sectional controlled study.MethodsThe eyes of 65 patients with the diagnosis of keratoconus with no history of contact lens wear and the eyes of 40 healthy controls were prospectively examined using the Heidelberg Retinal Tomography Rostock Cornea Module (HRT3/RCM). The average ECD from the two groups were then compared.ResultsOf the cases with keratoconus, 44 (67.7%) were men and 21 (32.3%) were women. The mean age was 20.9 ± 6.8 (range = 10–41) years. Of the controls, 28 (70%) were men and 12 (30%) were women. The mean age was 23.9 ± 5.8 (range = 14–35) years. Of the 65 eyes with keratoconus, 19 (29.2%) had mild keratoconus, 21 (32.3%) had moderate keratoconus, and 25 (38.5%) had severe keratoconus. The mean ECD was 2731.6 ± 303.2 cells/mm2 in cases with keratoconus and 2664.9 ± 319.5 cells/mm2 in controls. There was no difference between the densities (unpaired t-test, P = 0.4). No significant relationships were found between the ECD data and central corneal thickness or steepest keratometric.ConclusionsEndothelial cell density was unaltered in keratoconic patients without a history of contact lens use when compared with healthy controls. Change in ECD is independent from the central corneal thickness and the stage of keratoconus.  相似文献   

8.
PurposeThis study compared the biocompatibility and comfort of 4 lens care solutions currently marketed in France.MethodsThis was a randomized, interventional, double-masked, single-center crossover study assessing balafilcon A silicone hydrogel contact lenses, bilaterally, straight from the blister pack solution (control) and pre-soaked in the following lens care solutions: Regard® (containing sodium chlorite), ReNu® (containing a PHMB [polyhexamethylene biguanide] derivative), CyClean™ and MeniCare™ Soft (both containing PHMB). Subjects were randomized to the order of test solution use. For each of the 5 solutions tested, subjects attended a baseline/lens dispensing visit and an intervention visit 2 h later. At both visits, evaluation included slit-lamp examination, corrected-distance visual acuity, corneal staining, and subject-assessed photophobia, ocular comfort, and ocular redness.ResultsThirty subjects were enrolled and 28 were evaluable. Corneal staining severity was significantly worse than baseline after 2 h of wearing lenses soaked in CyClean, MeniCare, or ReNu (P  0.001). The MeniCare group alone demonstrated a significant improvement in ocular comfort after 2 h of lens wear (P = 0.02). No group demonstrated significant changes in ocular redness or photophobia. Corrected-distance visual acuity was similar between baseline and intervention visits for each test solution. No adverse events were reported during the study.ConclusionsSilicone hydrogel contact lenses presoaked in lens solutions containing PHMB or a PHMB derivative produced an increase in corneal staining after 2 h of lens wear. The higher levels of corneal staining in the 2 solutions did not correlate with increased discomfort within this 2-h timeframe.  相似文献   

9.
PurposeThis study was conducted to evaluate the effects of long-term use of rigid gas-permeable (RGP) contact lenses on corneal endothelium in keratoconus (KC) patients using non-contact specular microscopy. In addition, the correlation between wearing duration of RGP lenses (years & hours /d) and endothelial morphometric changes in KC patients was performed. This may provide more useful data for clinical application of RGP contact lens.Study designThis study was a prospective, observational, comparative, hospital based, nonrandomized, cross-sectional, and quantitative study.Subjects and methodsThe study included 40 eyes of non-wearer contact lens KC patients (group 1) and 38 KC eyes with a long history of Rose K2 RGP contact lens wearing (group 2). The corneal endothelial morphology such as endothelial cell density (ECD); coefficient of variation of cell area (CV); percentage of hexagonal cells (HEX); and central corneal thickness (CCT) were evaluated in all patients using SP3000P Specular Microscope.ResultsThe study included 40 eyes of non-wearer contact lens KC patients (20 mild KC eyes and 20 moderate KC eyes) and 38 KC eyes with a long history of RGP contact lens wearing (18 mild KC eyes and 20 moderate KC eyes). The mean duration of RGP lenses wearing was 5.67 ± 3.481 years & 12.11 ± 2.698 h/d in mild KC eyes and 7.15 ± 5.294 years &13.65 ± 2.889 h/d in moderate KC eyes. Wearing duration in hours in mild KC eyes showed a significant moderate negative correlation with ECD (r = ?0.529, p = 0.024) and a moderate positive correlation with CV (r = 0.565, p = 0.015). In addition, wearing duration in years in moderate KC eyes showed a significant moderate negative correlation with ECD (r = ?0.465, p = 0.039) and moderate positive correlation with CV (r = 0.627, p = 0.003). However, wearing duration in hours in moderate KC eyes showed a significant moderate negative correlation with HEX only (r = ?0.490, p = 0.028). This study reported significant corneal thinning in contact lens wearer KC eyes in contrast to non-wearer KC eyes.ConclusionThis study documented a significant correlation between a long-term use of Rose K2 RGP using the three-point touch and corneal endothelial morphometric changes in KC patients. In addition, the current study confirmed a significant corneal thinning in RGP contact lens wearer compared to non-contact lens wearer KC patients. Further studies are recommended to evaluate the association between different RGP lens materials with different oxygen permeability transmissibility; different lens design types; different fitting methods; the duration of contact lens wear and the endothelial morphometric changes in KC patients.  相似文献   

10.
PurposeTo evaluate the performance of two experimental contact lenses (CL) designed to induce relative peripheral myopic defocus in myopic eyes.MethodsTen right eyes of 10 subjects were fitted with three different CL: a soft experimental lens (ExpSCL), a rigid gas permeable experimental lens (ExpRGP) and a standard RGP lens made of the same material (StdRGP). Central and peripheral refraction was measured using a Grand Seiko open-field autorefractometer across the central 60° of the horizontal visual field. Ocular aberrations were measured with a Hartman-Shack aberrometer, and monocular contrast sensitivity function (CSF) was measured with a VCTS6500 without and with the three contact lenses.ResultsBoth experimental lenses were able to increase significantly the relative peripheral myopic defocus up to −0.50 D in the nasal field and −1.00 D in the temporal field (p < 0.05). The ExpRGP induced a significantly higher myopic defocus in the temporal field compared to the ExpSCL. ExpSCL induced significantly lower levels of Spherical-like HOA than ExpRGP for the 5 mm pupil size (p < 0.05). Both experimental lenses kept CSF within normal limits without any statistically significant change from baseline (p > 0.05).ConclusionsRGP lens design seems to be more effective to induce a significant myopic change in the relative peripheral refractive error. Both lenses preserve a good visual performance. The worsened optical quality observed in ExpRGP was due to an increased coma-like and spherical-like HOA. However, no impact on the visual quality as measured by CSF was observed.  相似文献   

11.
Purposeto evaluate changes in tear metrics and ocular signs induced by six months of silicone-hydrogel contact lens wear and the difference in baseline characteristics between those who successfully continued in contact lens wear compared to those that did not.MethodsNon-invasive Keratograph, Tearscope and fluorescein tear break-up times (TBUTs), tear meniscus height, bulbar and limbal hyperaemia, lid-parallel conjunctival folds (LIPCOF), phenol red thread, fluorescein and lissamine-green staining, and lid wiper epitheliopathy were measured on 60 new contact lens wearers fitted with monthly silicone-hydrogels (average age 36 ± 14 years, 40 females). Symptoms were evaluated by the Ocular Surface Disease Index (OSDI). After six months full time contact lens wear the above metrics were re-measured on those patients still in contact lens wear (n = 33). The initial measurements were also compared between the group still wearing lenses after six months and those who had ceased lens wear (n = 27).ResultsThere were significant changes in tear meniscus height (p = 0.031), bulbar hyperaemia (p = 0.011), fluorescein TBUT (p = 0.027), corneal (p = 0.007) and conjunctival (p = 0.009) staining, LIPCOF (p = 0.011) and lid wiper epitheliopathy (p = 0.002) after six months of silicone-hydrogel wear. Successful wearers had a higher non-invasive (17.0 ± 8.2 s vs 12.0 ± 5.6 s; p = 0.001) and fluorescein (10.7 ± 6.4 s vs 7.5 ± 4.7 s; p = 0.001) TBUT than drop-outs, although OSDI (cut-off 4.2) was also a strong predictor of success.ConclusionSilicone-hydrogel lenses induced significant changes in the tear film and ocular surface as well as lid margin staining. Wettability of the ocular surface is the main factor affecting contact lens drop-out.  相似文献   

12.
PurposeTo study the indications and the challenges while fitting scleral contact lens (ScCL) filled with fluid prior to lens insertion in pediatric patients.MethodsWe retrospectively reviewed charts of patients of 16 years or less who received ScCL (PROSE – Prosthetic Replacement of the Ocular Surface Ecosystem, Boston Foundation for Sight, Needham Heights, MA, USA) that were filled with fluid (Normal saline) before lens insertion during July 2006 to April 2010. The main goal of ScCL fitting was to improve vision in patients having keratoconus (KC) and improve the ocular microenvironment in ocular surface disease (OSD). Visual acuity before and after lens wear was noted.ResultsFluid-filled ScCL were dispensed to 15 patients (20 eyes). The indications for ScCL fitting were KC (n = 3 eyes), Stevens Johnson syndrome (SJS, n = 13 eyes), radiation keratopathy (n = 1 eye), combined KC and SJS (n = 1 eye) and KC and vernal keratoconjunctivitis (VKC, n = 2 eyes). Mean age of the patients was 12.85 years. The average daily lens wear was 9 h. The vision improved by 2 lines or more in 85% and dropped by 2 lines or more in 45% eyes after 4 h of lens wear due to tear debris collection. None of the patients had any complications. Patients were self sufficient inserting and removing ScCL. Two patients had broken lenses during the follow-up.ConclusionsScCL are useful for pediatric patients who have OSD, irregular astigmatism or the two coexisting; KC combined with VKC or SJS, helping to maintain the health of the ocular surface and improves vision in these patients.  相似文献   

13.
PurposeTo evaluate keratoconus biomechanical changes after transepithelial corneal collagen cross linking (TE CXL) using riboflavin and ultraviolet A (UVA).SettingSecond University of Naples, Naples, Italy.DesignProspective non comparative case series study.MethodsPatients with progressive keratoconus were examined, before and during a 6 months follow up after TE CXL, with a Pentacam, an Ocular Response Analyzer and an IOLMaster.Best corrected visual acuity (BCVA), refraction, corneal thinnest point (CTP), keratometry readings at the keratoconus apex (Kmax), axial eye length (AL), corneal volume (CV) anterior chamber volume (ACV), anterior chamber depth (ACD), corneal hysteresis (CH) and corneal resistance factor (CRF) were evaluated.ResultsThirty-six eyes of 36 patients with progressive keratoconus were analyzed. Six months after treatment there was a significant improvement in BCVA (p < 0.01), no significant changes in refraction (p = 0.57), CTP (p = 0.07), Kmax (p = 0.88), AL (p = 0.07), CV (p = 0.38), ACV (p = 0.07), ACD (p = 0.7), CH (p = 0.1) and CRF (p = 0.3).ConclusionsAccording to our results TE CXL stabilizes most of the patients with progressive keratoconus, without affecting in negative way the corneal elasticity.  相似文献   

14.
PurposeTo examine the influence of short-term miniscleral contact lens wear on corneal shape, thickness and anterior surface aberrations.MethodsScheimpflug imaging was captured before, immediately following and 3 h after a short period (3 h) of miniscleral contact lens wear for 10 young (mean 27 ± 5 years), healthy participants. Natural diurnal variations were considered by measuring baseline diurnal changes obtained on a separate control day without contact lens wear.ResultsSmall but significant anterior corneal flattening was observed immediately following lens removal (overall mean 0.02 ± 0.03 mm, p < 0.001) which returned to baseline levels 3 h after lens removal. During the 3 h recovery period significant corneal thinning (−13.4 ± 10.5 μm) and posterior surface flattening (0.03 ± 0.02 mm) were also observed (both p < 0.01). The magnitude of posterior corneal flattening during recovery correlated with the amount of corneal thinning (r = 0.69, p = 0.03). Central corneal clearance (maximum tear reservoir depth) was not associated with corneal swelling following lens removal (r = −0.24, p > 0.05). An increase in lower-order corneal astigmatism Z(2,2) was also observed following lens wear (mean −0.144 ± 0.075 μm, p = 0.02).ConclusionsFlattening of the anterior corneal surface was observed immediately following lens wear, while ‘rebound’ thinning and flattening of the posterior surface was evident following the recovery period. Modern miniscleral contact lenses that vault the cornea may slightly influence corneal shape and power but do not induce clinically significant corneal oedema during short-term wear.  相似文献   

15.
PurposeTo evaluate the efficacy of two silicone hydrogel (SiH) contact lenses, approved for continuous wear for one week, following photorefractive keratectomy (PRK).MethodsForty seven myopic patients (94 eyes) undergone bilateral PRK were enrolled in this prospective, double-masked, comparative study. One eye of each patient was fitted with a Lotrafilcon B lens (Ciba Vision, Duluth, US; 30-day recommended replacement) whereas the fellow eye was fitted with an Asmofilcon A lens (Menicon, Nagoya, Japan; 14-day recommended replacement). Epithelial defect size was assessed using slit lamp biomicroscopy on the day of surgery and at days 1–4 post-operatively. Uncorrected and best-corrected visual acuity and retinal straylight (C-Quant, Oculus Optigerate, Germany) were evaluated pre-operatively and one month post-operatively.ResultsAverage epithelial defect size for Asmofilcon A and Lotrafilcon B was 25.5 ± 11.0 mm2 vs. 27.1 ± 9.9 mm2 at day 1 (p = 0.007) and 6.3 ± 7.0 mm2 vs. 9.2 ± 9.5 mm2 at day 2 (p = 0.012) post-operatively. Re-epithelialization at day 3 was completed in 87.2% of the eyes fitted with Asmofilcon A lenses, compared to 74.5% with Lotrafilcon B lenses (p = 0.012). At the 3rd post-operative day 29.8% of re-epithelialized eyes showed irregular suture with Lotrafilcon B, compared to 12.8% eyes with Asmofilcon A lenses (p < 0.001). Finally, no statistically significant differences were found post-operatively between the two lenses retinal straylight (p = 0.98) and best-corrected visual acuity (p = 0.68).ConclusionsSiH lenses can be used as an effective bandage after PRK due to the limited time requested for achieving complete corneal re-epithelialization. Faster and smoother epithelial healing is provided with Asmofilcon A over Lotrafilcon B lenses.  相似文献   

16.
PurposeTo compare conventional method of contact lens fitting with software based contact lens fitting using Medmont corneal topographer in eyes with nebular and macular corneal scars.MethodsFifteen participants who were diagnosed with nebular and macular scars were fitted with rigid gas permeable lenses using conventional method of contact lens fitting. During the lens dispensing visit, participants underwent Medmont corneal topography. Agreement between the two methods of contact lens fitting was studied.ResultsParameters of contact lenses which were concluded using conventional method was compared to that of software based fitting. Mean difference in base curve of contact lens between the two methods was 0.094 mm ± 0.147 mm (95% CI: +0.383 to −0.194). Mean difference in diameter of contact lens between the two methods was 0.16 mm ± 0.172 mm (95% CI: +0.497 to −0.177). Contact lens parameters that were achieved using two different methods of fitting showed good correlation. Correlation coefficients, as comparison of two methods in base curve and diameter were 0.96 (P < 0.05) and 0.94 (P < 0.05), respectively.ConclusionSoftware based contact lens fitting would be useful for contact lens practitioners to predict initial base curve of contact lens in corneal scars.  相似文献   

17.
PurposeReplacing soft contact lenses (CLs) on a daily basis brings a number of advantages, most notably, reduced exposure to deposits, disinfectants, allergens, and other contaminants. This retrospective study estimated the prevalence of problems in current wearers of reusable soft CLs and tested the effect of refitting “problem” patients with daily disposable (DD) hydrogel lenses.MethodsPrevalence was estimated from 398 current reusable CL wearers for: frequent/constant discomfort or dryness, ≥2 h of uncomfortable wear, ≥grade 2 conjunctival hyperaemia (0–4), or ≥grade 3 corneal staining (0–15). In the second part of the study, 217 reusable CL wearers classified as problem patients were randomly refitted with DD lenses manufactured from one of two materials: etafilcon A (n = 96) or nelfilcon A (n = 121) and reassessed 1 week later.ResultsThirty-nine percent (154/398) had some qualifying criterion: reduced comfortable wearing time (CWT), 20%; dryness, 20%; irritation, 5%; corneal staining, 8%; and hyperaemia, 7%. After refitting with DDs, the prevalence of reduced CWT was decreased from 65% to 51% (P = 0.0039), dryness from 60% to 41% (P < 0.0001) and corneal staining from 28% to 21% (P = 0.04). There was no significant change in the prevalence of irritation, or hyperaemia. Some differences were noted between the two lens materials.ConclusionsA high proportion of reusable soft lens wearers encounter clinically relevant signs or symptoms with their current CLs. This study provides evidence that refitting with DD lenses is a useful strategy for alleviating some of the common problems of CL wear.  相似文献   

18.
IntroductionAccurate corneal measurements are crucial in corneal refractive surgery (CRS) to ensure successful outcomes. Soft contact lens (SCL) wear may result in changes to corneal curvature and structure. United States Food and Drug Administration (FDA) pre-operative guidelines recommend that prior to CRS, SCL wearers cease SCL wear for “at least two weeks before examination and treatment” [1]. Corneal curvature changes induced by SCL wear may take longer than two weeks to resolve.PurposeTo examine the effect of SCL wear on corneal curvature before and following two weeks SCL wear cessation. To explore the possible impact of different SCL materials and years of SCL wear.MethodsRetrospective data analysis, between a group of SCL wearers (SCL: n = 45); and a non-contact lens control group (NCL: n = 45). Corneal curvature parameters were measured using the Pentacam (Oculus, Germany), before and following two weeks cessation of SCL wear.ResultsNo significant differences in keratometry or Sagittal radius of curvature between SCL and NCL groups prior to or following SCL cessation. Tangential radius of curvature showed significant inferior steepening for the SCL group prior to SCL cessation (SCL vs. NCL; 7.77 ± 0.30 mm vs. 7.90 ± 0.30 mm; p = 0.04). Following two weeks cessation of SCL wear this appeared to have resolved.ConclusionsTwo weeks cessation of SCL wear appears sufficient for resolution of corneal curvature changes with modern SCL materials and years of SCL wear. However, further studies with longer lens deprivation periods are required to ensure stability for all SCL wearing patients.  相似文献   

19.
PurposeTo compare the topographic and biomechanical properties of corneas in eyes of patients with ichthyosis vulgaris (IV) and eyes of healthy individuals.MethodsThirty healthy individuals (control group) and 30 patients with IV (study group) were enrolled in this prospective study. Topographic measurements, including keratometry values, irregularity, and surface asymmetry index in the right eye of each participant were obtained using Scheimpflug camera with a Placido disc topographer (Sirius). Corneal hysteresis (CH), corneal resistance factor (CRF), corneal-compensated intraocular pressure (IOPcc) and Goldman-related intraocular pressure (IOPg) were measured using the Reichert Ocular Response Analyzer (ORA). Central corneal thickness (CCT) was also measured with ultrasonic pachymetry and the Sirius corneal topography system.ResultsTopographic parameters were not significantly different between both groups (p > 0.05). Although mean CH was not significantly different between the groups, the CRF was significantly lower in patients with IV (p = 0.249 and p = 0.005, respectively). The CCT was significantly lower in patients with IV compared to healthy controls (p < 0.001). The IOPg and IOPcc were significantly lower in the patients with ichthyosis than in healthy controls (p = 0.001 and p = 0.004, respectively).ConclusionsThe study demonstrated that while the eyes of patients with IV had corneal topographic findings and corneal hysteresis similar to those of healthy controls, some of corneal biomechanical properties such CRF and CCT and IOP values such as IOPg and IOPcc were significantly lower in patients with IV. These results should be taken into account when planning a corneal refractive surgery and glaucoma screening for patients with IV.  相似文献   

20.

Purpose

To investigate the effect of soft contact lenses (SCL) wearing modality and lens materials on the changes in conjunctival bulbar and limbal redness and conjunctival and corneal staining after two months of SCL wear. Comfort level was also analyzed.

Methods

In this longitudinal clinical trial, forty-seven neophyte myopic subjects were fitted with a monthly disposable lens (lotrafilcon-B or comfilcon-A or balafilcon-A) in one eye and a daily disposable lens (nelfilcon-A or stenofilcon-A or nesofilcon-A) in the other eye, randomly selected. Conjunctival bulbar and limbal redness and conjunctival and corneal staining were evaluated before and after lens wear. Effect of lens wearing modality and lens materials on these changes was also determined. Level of comfort was evaluated subjectively twice per day. Comfort level and reduction in end-of-day comfort were compared between different lens wearing modalities and materials.

Results

Bulbar and limbal redness and conjunctival and corneal staining were increased (p < 0.001) after lens wear, and changes were similar with daily and monthly disposable lens wear (p > 0.05). Limbal redness was associated with lens materials, and lotrafilcon-B induced the least among the studied lenses (p < 0.05). There was no significant association between the wearing modality and the average comfort level and reduction of end-of-day comfort (p > 0.05).

Conclusion

Two months of SCL wear increased conjunctival redness, conjunctival and corneal staining, which were not associated with the lens wearing modality. There was a reduction in end-of-day comfort, similar to daily and monthly lenses. The change in limbal redness and reduction in end-of-day comfort were associated with the characteristics of the lens material.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号