首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 34 毫秒
1.
A new combined power and refrigeration cycle is proposed for the cogeneration, which combines the Rankine cycle and the ejector refrigeration cycle by adding an extraction turbine between heat recovery vapor generator (HRVG) and ejector. This combined cycle could produce both power output and refrigeration output simultaneously, and could be driven by the flue gas from gas turbine or engine, solar energy, geothermal energy and industrial waste heats. Parametric analysis and exergy analysis are conducted to examine the effects of thermodynamic parameters on the performance and exergy destruction in each component for the combined cycle. The results show that the condenser temperature, the evaporator temperature, the turbine inlet pressure, the turbine extraction pressure and extraction ratio have significant effects on the turbine power output, refrigeration output, exergy efficiency and exergy destruction in each component in the combined cycle. It is also shown that the biggest exergy destruction occurs in the heat recovery vapor generator, followed by the ejector and turbine.  相似文献   

2.
提出一种新型跨临界二氧化碳(trans-critical carbon dioxide,TCO2)再压缩循环和喷射器制冷循环耦合的冷电联供系统。该系统在输出电能的同时,利用低品位热能驱动喷射器工作输出冷量。以输出电量1 MW为设计目标,对比冷电联供系统和再压缩发电系统的性能,研究联供系统各部件(火用)损和主要热力参数对其性能的影响。结果表明:联供系统利用CO2余热驱动喷射器输出冷量,循环热效率高于单一再压缩系统;加热器(火用)损所占比例最大,回热器次之;透平进口温度、压力和背压对联供系统工质流量、循环效率、输出功率、加热器功率、压缩机耗功及喷射器制冷量等参数影响较大;而冷凝温度和蒸发温度仅对制冷循环制冷量影响较大。在设定条件下,联供系统的循环热效率和(火用)效率可分别达到46.99%和47.21%。  相似文献   

3.
A refrigeration system was developed which combines a basic vapor compression refrigeration cycle with an ejector cooling cycle. The ejector cooling cycle is driven by the waste heat from the condenser in the vapor compression refrigeration cycle. The additional cooling capacity from the ejector cycle is directly input into the evaporator of the vapor compression refrigeration cycle. The governing equations are derived based on energy and mass conservation in each component including the compressor, ejector, generator, booster and heat exchangers. The system performance is first analyzed for the on-design conditions. The results show that the COP is improved by 9.1% for R22 system. The system is then compared with a basic refrigeration system for variations of five important variables. The system analysis shows that this refrigeration system can effectively improve the COP by the ejector cycle with the refrigerant which has high compressor discharge temperature.  相似文献   

4.
A conceptual trigeneration system is proposed based on the conventional gas turbine cycle for the high temperature heat addition while adopting the heat recovery steam generator for process heat and vapor absorption refrigeration for the cold production. Combined first and second law approach is applied and computational analysis is performed to investigate the effects of overall pressure ratio, turbine inlet temperature, pressure drop in combustor and heat recovery steam generator, and evaporator temperature on the exergy destruction in each component, first law efficiency, electrical to thermal energy ratio, and second law efficiency of the system. Thermodynamic analysis indicates that exergy destruction in combustion chamber and HRSG is significantly affected by the pressure ratio and turbine inlet temperature, and not at all affected by pressure drop and evaporator temperature. The process heat pressure and evaporator temperature causes significant exergy destruction in various components of vapor absorption refrigeration cycle and HRSG. It also indicates that maximum exergy is destroyed during the combustion and steam generation process; which represents over 80% of the total exergy destruction in the overall system. The first law efficiency, electrical to thermal energy ratio and second law efficiency of the trigeneration, cogeneration, and gas turbine cycle significantly varies with the change in overall pressure ratio and turbine inlet temperature, but the change in pressure drop, process heat pressure, and evaporator temperature shows small variations in these parameters. Decision makers should find the methodology contained in this paper useful in the comparison and selection of advanced heat recovery systems.  相似文献   

5.
This paper describes a novel refrigeration cycle based on the combination of an absorption cycle with an ejector refrigeration cycle. The combination brings together the advantages of absorption and ejector refrigeration systems and provides high COP for refrigeration and air-conditioning. The combined cycle is particularly suitable for utilising waste thermal energy. A computer simulation program was developed for the combined cycle and used to determine the performance of the system using LiBrH2O for various generator, condenser and evaporator temperatures. Optimum operating conditions and ejector design data are also provided.  相似文献   

6.
在热电冷联产系统中,溴化锂吸收式制冷机在制冷过程中排放了大量的废热,这些废热品味低,难以直接回收利用。在此提出了两级双效溴化锂制冷-热泵复合循环,该循环具有冷凝温度较高的特点,便于直接回收冷凝排放热。系统以背压汽轮机的背压蒸汽为热源,制冷的同时利用循环所排出的废热加热锅炉补充水至较高温度。以具有相同功效的双效溴冷机与单效溴化锂热泵联合运行作为对比循环,制冷-热泵复合循环系统省去了一台蒸发器与冷凝器,减少了两个换热温差,并且通过热力计算、能量分析和分析表明,该循环的能量利用率与效率均有很大的提高,效率比对比循环提高了45%。  相似文献   

7.
通过利用线性拟合的方法对氨的物性进行模拟,在变冷凝温度和变冷间温度,以及在蒸发器和冷凝器压力降变化的条件下,分别对冷库中的氨双级蒸汽压缩系统进行能量分析,对系统各部件的炯损失和系统的炯效率进行计算分析,得出随着冷凝温度和冷间温度的改变,系统各设备的炯损失的排序变化的结果,以及随着压力降的变化系统的性能发生了变化,提出改进系统的性能可从减少冷凝传热温差和减少冷间传热温差,提高冷却水有效利用,改善蒸发器的压力降方面考虑。  相似文献   

8.
This paper studies the influence of working fluids over the performance of heat driven ejector refrigeration systems performance by using a lumped parameter model. The model used has been selected after a comparison of different models with a set of experimental data available in the literature. The effect of generator, evaporator and condenser temperature over the entrainment ratio and the COP has been investigated for different working fluids in the typical operating conditions of low grade energy sources. The results show a growth in performance (the entrainment ratio and the COP) with a rise in the generator and evaporator temperature and a decrease in the condenser temperature. The working fluids have a great impact on the ejector performance and each refrigerant has its own range of operating conditions. R134a is found to be suitable for low generator temperature (70–100 °C), whereas the hydrocarbons R600 is suitable for medium generator temperatures (100–130 °C) and R601 for high generator temperatures (130–180 °C).  相似文献   

9.
In this paper, an ejector enhanced vapor injection CO2 transcritical heat pump cycle with sub-cooler (ESCVI) for heating application in cold regions is proposed. The thermodynamic analysis using energetic and exegetic methods is carried out to predict the performance characteristics of the ejector enhanced cycle, and then compared with those of the conventional vapor injection heat pump cycle with sub-cooler (SCVI). The simulation results demonstrate that the ejector enhanced cycle exhibits better performance than the conventional vapor injection cycle under the specified operating conditions. The improvements of the maximum system COP and volumetric heating capacity could reach up to 7.7% and 9.5%, respectively. Exergetic analysis indicates that the largest exergy destruction ratio is generated at the compressor followed by the evaporator and gas cooler. Additionally, the exergy efficiency of the ejector is introduced to quantify the effectiveness of the exergy recovery process, which may be a new criterion to evaluate the performance of the ejector enhanced vapor compression cycle.  相似文献   

10.
Experimental investigation on R134a vapour ejector refrigeration system   总被引:6,自引:1,他引:5  
The experimental investigation of the performance of a vapour ejector refrigeration system is described. The system uses R134a as working fluid and has a rated cooling capacity of 0.5 kW. The influence of generator, evaporator and condenser temperatures on the system performance is studied. This kind of system can be operated with low grade thermal energy such as solar energy, waste heat, etc. The operating conditions are chosen accordingly as, generator temperature between 338 K and 363 K, condenser temperature between 299 K and 310.5 K, and evaporator temperature between 275 K and 285.5 K. Six configurations of ejectors of different geometrical dimensions are selected for the parametric study. The performance of the refrigeration system at different operating temperatures is presented.  相似文献   

11.
In the proposed cogeneration cycle, a LiBr-H2O absorption refrigeration system is employed to the combined power and ejector refrigeration system which uses R141b as a working fluid. Estimates for irreversibilities of individual components of the cycle lead to possible measures for performance improvement. Results of exergy distribution of waste heat in the cycle show that around 53.6% of the total input exergy is destroyed due to irreversibilities in the components, 22.7% is available as a useful exergy output, and 23.7% is exhaust exergy lost to the environment, whereas energy distribution shows 44% is exhaust energy and 19.7% is useful energy output. Results also show that proposed cogeneration cycle yields much better thermal and exergy efficiencies than the previously investigated combined power and ejector cooling cycle. Current investigation clearly show that the second law analysis is quantitatively visualizes losses within a cycle and gives clear trends for optimization.  相似文献   

12.
The combined power and cooling cycles driven by waste heat and renewable energy can provide different kinds of energy forms and achieve a higher thermodynamic efficiency. However, only a few researchers have focused on the improvement of temperature matching between the heat source and working fluid. This paper proposes a transcritical power and ejector refrigeration cycle (TPERC) to improve temperature matching between the heat source and working fluid. Based on the modelling of the TPERC system, a comparison of working fluids and the effects of system parameters on the cooling capacity, work output, thermal efficiency and exergy efficiency are discussed. The results show that of the seven working fluids selected, R1234ze has the largest thermal efficiency and exergy efficiency, principally due to having the highest critical temperature. At the identical turbine back pressure, condensing temperature and evaporation temperature, the turbine inlet temperature and its corresponding generation pressure have little impact on thermal efficiency.  相似文献   

13.
This paper discusses the conservation of energy in a cogeneration system. A steam power cycle (Rankine) produces electrical power 2 MW and steam is bleeded off from the turbine at 7 bar to warm a factory or units of buildings during the winter or to supply a steam ejector refrigeration cycle to air-conditioning the same area during the summer. In the summer this system can be as alternative solution instead of absorption. Certainly the ejector refrigeration unit is more economical than absorption unit. The ratio of electrical power/heat is varied into the region (0.1–0.4) and the evaporator temperature of the ejector cycle is varied into the region (10–16 °C). A computer program has been developed for the study of performance parameters of the cogeneration system.  相似文献   

14.
Development of a circulating system for a jet refrigeration cycle   总被引:1,自引:0,他引:1  
This paper proposed a workless-generator-feeding (WGF) system for a jet refrigeration cycle, using R141b. This feeding system does not require any mechanical power. The liquid refrigerant from the condenser was fed to the vapour-generator by means of the generator pressure and gravitational force. The system was tested and compared with a conventional system using a mechanical pump. It was found that this system was workable. The heat input to the generator was slightly higher than that for a system using a mechanical pump. The jet refrigeration cycle employing this new feeding system provided a slightly lower coefficient of performance (COP) compared to a system using a mechanical pump. However, this new system did not require any mechanical energy. Therefore, the jet refrigeration system employing this WGF system is truly a heat-power refrigeration cycle.  相似文献   

15.
This paper presented a novel autocascade refrigeration cycle (NARC) with an ejector. In the NARC, the ejector is used to recover some available work to increase the compressor suction pressure. The NARC enables the compressor to operate at lower pressure ratio, which in turn improves the cycle performance. Theoretical computation model based on the constant pressure-mixing model for the ejector is used to perform a thermodynamic cycle analysis for the NARC with the refrigerant mixture of R23/R134a. The effects of some main parameters on cycle performance were investigated. The results show the NARC has an outstanding merit in decreasing the pressure ratio of compressor as well as increasing the COP. For NARC operated at the condenser outlet temperature of 40 °C, the evaporator inlet temperature of −40.3 °C, and the mass fraction of R23 is 0.15, the pressure ratio of the ejector reaches to 1.35, the pressure ratio of compressor is reduced by 25.8% and the COP is improved by 19.1% over the conventional autocascade refrigeration cycle.  相似文献   

16.
Irreversibilities in components of an aqua-ammonia absorption refrigeratio system (ARS) have been determined by second law analysis. The components of the ARS are as follows: condenser, evaporator, absorber, generator, pump, expansion valves, mixture heat exchanger and refrigerant heat exchanger. It is assumed that the ammonia concentration at the generator exit is, independent of the other parameters, equal to 0.999 and at the evaporator exit the gas is saturated vapour. Pressrre losses between the generator and condenser, and the evaporator and absorber are taken into consideration. In the results the dimensionless exergy loss of each component, the exergetic coefficient of performance, the coefficient of performance and the circulation ratio are given graphically for each different generator, evaporator, condenser and absorber temperature.  相似文献   

17.
An integrated system for simultaneous production of triple-effect cooling and single stage heating is proposed in this paper to harness low grade solar energy. The proposed system combines the heliostat field with a central receiver and the ejector-absorption cycle with the shaft power driven transcritical CO2 cycle. A parametric study based on first and second laws of thermodynamics is carried out to ascertain the effect of varying the exit temperature of duratherm oil, turbine inlet pressure, and evaporators temperature on the energy and exergy output as well as on the energy and exergy efficiencies of the system. The results obtained indicate that major source of exergy destruction is the central receiver where 52.5% of the inlet solar heat exergy is lost followed by the heliostat where 25% of the inlet exergy is destroyed. The energy and exergy efficiencies of the integrated system vary from 32% to 39% and 2.5%–4.0%, respectively, with a rise in the hot oil outlet temperature from 160 °C–180 °C. It is further shown that increase in evaporator temperature of transcritical CO2 cycle from −20 °C to 0 °C increases the energy efficiency from 27.45% to 43.27% and exergy efficiency from 2.51% to 2.97%, respectively. The results clearly show how the variation in the values of hot oil outlet temperature, turbine inlet pressure, and the evaporator temperature of transcritical CO2 cycle strongly influences the attainable performance of the integrated system.  相似文献   

18.
通过对一定环境温度条件下的高温冷库中的氨蒸汽压缩系统进行[火用]分析,利用线性拟合的方法对氨的物性进行模拟,并对定冷凝温度和变冷凝温度时,制冷系统的各部件的炯损失和系统的[火用]效率进行计算分析,得出在冷库氨蒸汽压缩系统中的蒸发器中的[火用]损失最大,压缩机和冷凝器次之的结果。提出要对冷库氨蒸汽压缩系统的性能进行改进,必须首先考虑提高其蒸发器、压缩机和冷凝器的[火用]效率着手;认为在一定环境温度条件下,降低冷凝温度是提高[火用]效率的较好的改进措施之一.  相似文献   

19.
Exergy analysis is a useful way for determining the real thermodynamic losses and optimising environmental and economic performance in the systems such as vapour compression refrigeration systems. The present study deals with the exergy analysis on a two evaporator vapour compression refrigeration system using R1234yf, R1234ze and R134a as refrigerants. In the calculation of losses occurring in different system components, besides the exergy efficiency of the refrigeration cycle, a computer code was developed by using Engineering Equation Solver (EES-V9.172-3D) software package program. The effects of the evaporator and condenser temperatures on the exergy destruction and exergy efficiency of the system were investigated. R1234yf and R1234ze, which are good alternatives to R134a concerning their environmentally friendly properties and this is the most significant finding emerging from this study.  相似文献   

20.
A gas turbine engine was used to drive the compressor of a vapour compression cycle so that the usually wasted energy in the exhaust gases was partially recovered and used in the generator of an absorption cycle. The cooling effect was therefore boosted. The degree of energy utilization was further enhanced when the energy released from the absorber and condenser of both cycles was recovered in the form of hot water, which could be used for different applications. The performance parameters for this combined system, such as the cooling effect, total heat recovered and performance effectiveness ratio, were calculated for various evaporator and condenser temperatures. It was found that a system driven by a gas turbine gives a better performance than a diesel engine system under similar operating conditions.  相似文献   