首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A significant number of consumer goods and building materials can act as emission sources of flame retardants (FRs) in the indoor environment. We investigate the relationship between the emission source strength and the levels of 19 brominated flame retardants (BFRs) and seven organophosphate flame retardants (OPFRs) in air and dust collected in 38 indoor microenvironments in Norway. We use modeling methods to back‐calculate emission rates from indoor air and dust measurements and identify possible indications of an emission‐to‐dust pathway. Experimentally based emission estimates provide a satisfactory indication of the relative emission strength of indoor sources. Modeling results indicate an up to two orders of magnitude enhanced emission strength for OPFRs (median emission rates of 0.083 and 0.41 μg h?1 for air‐based and dust‐based estimates) compared to BFRs (0.52 and 0.37 ng h?1 median emission rates). A consistent emission‐to‐dust signal, defined as higher dust‐based than air‐based emission estimates, was identified for four of the seven OPFRs, but only for one of the 19 BFRs. It is concluded, however, that uncertainty in model input parameters could potentially lead to the false identification of an emission‐to‐dust signal.  相似文献   

2.
The envelope of low‐energy buildings is generally constructed with significant amounts of plastics, sealants and insulation materials that are known to contain various chemical additives to improve specific functionalities. A commonly used group of additives are flame retardants to prevent the spread of fire. In this study, decabromodiphenyl ether (BDE‐209) and fourteen emerging brominated flame retardants (BFRs) were analyzed in indoor dust, air and on the window surface of newly built low‐energy preschools to study their occurrence and distribution. BDE‐209 and decabromodiphenyl ethane (DBDPE) were frequently detected in the indoor dust (BDE‐209: <4.1‐1200 ng/g, DBDPE: <2.2‐420 ng/g) and on window surfaces (BDE‐209: <1000‐20 000 pg/m2, DBDPE: <34‐5900 pg/m2) while the other thirteen BFRs were found in low levels (dust: <0.0020‐5.2 ng/g, window surface: 0.0078‐35 pg/m2). In addition, the detection frequencies of BFRs in the indoor air were low in all preschools. Interestingly, the dust levels of BDE‐209 and DBDPE were found to be lower in the environmentally certified low‐energy preschools, which could be attributed to stricter requirements on the chemical content in building materials and products. However, an increase of some BFR levels in dust was observed which could imply continuous emissions or introduction of new sources.  相似文献   

3.
Retail stores contain a wide range of products that can emit a variety of indoor pollutants. Among these chemicals, phthalate esters and polybrominated diphenyl ethers (PBDEs) are two important categories of semi‐volatile organic compounds (SVOCs). Filters in heating, ventilation, and air‐conditioning (HVAC) system collect particles from large volumes of air and thus potentially provide spatially and temporally integrated SVOC concentrations. This study measured six phthalate and 14 PBDE compounds in HVAC filter dust in 14 retail stores in Texas and Pennsylvania, United States. Phthalates and PBDEs were widely found in the HVAC filter dust in retail environment, indicating that they are ubiquitous indoor pollutants. The potential co‐occurrence of phthalates and PBDEs was not strong, suggesting that their indoor sources are diverse. The levels of phthalates and PBDEs measured in HVAC filter dust are comparable to concentrations found in previous investigations of settled dust in residential buildings. Significant correlations between indoor air and filter dust concentrations were found for diethyl phthalate, di‐n‐butyl phthalate, and benzyl butyl phthalate. Reasonable agreement between measurements and an equilibrium model to describe SVOC partitioning between dust and gas‐phase is achieved.  相似文献   

4.
Consumer products and building materials emit a number of semivolatile organic compounds (SVOCs) in the indoor environment. Because indoor SVOCs accumulate in dust, we explore the use of dust to determine source strength and report here on analysis of dust samples collected in 30 US homes for six phthalates, four personal care product ingredients, and five flame retardants. We then use a fugacity‐based indoor mass balance model to estimate the whole‐house emission rates of SVOCs that would account for the measured dust concentrations. Di‐2‐ethylhexyl phthalate (DEHP) and di‐iso‐nonyl phthalate (DiNP) were the most abundant compounds in these dust samples. On the other hand, the estimated emission rate of diethyl phthalate is the largest among phthalates, although its dust concentration is over two orders of magnitude smaller than DEHP and DiNP. The magnitude of the estimated emission rate that corresponds to the measured dust concentration is found to be inversely correlated with the vapor pressure of the compound, indicating that dust concentrations alone cannot be used to determine which compounds have the greatest emission rates. The combined dust‐assay modeling approach shows promise for estimating indoor emission rates for SVOCs.  相似文献   

5.
Particle resuspension has been recognized as a secondary source of indoor air pollution by many field studies. However, some laboratory studies showed that the air velocities or force fields required to resuspend aerosol particles are very high that rarely occurred in indoor environments. In fact, the surfaces used in these studies were treated to ensure cleanliness, but in reality, dusty surfaces are ubiquitous in our daily life. This work aims to investigate the effect of dust on a surface on resuspension of a coarse particle (polyethylene) by a centrifugal method. Dusty surfaces with different loadings were made by gravitational settling of Arizona test dust on a clean poly(methyl methacrylate) substrate inside a deposition chamber. The resuspension of dust particles was first investigated, and it was found that dust particles were resuspended by two stages with different rates of resuspension. For the resuspension of the particles on the dusty surface, the remaining fraction of the polyethylene particles decreased with increasing force field and dust loading. Dust could greatly reduce the adhesion of the particles from one to two orders of magnitude depending on loadings. This gives an explanation to the discrepancy between the field and the laboratory studies.  相似文献   

6.
Although the ubiquitous detection of polybrominated diphenyl ether (PBDE) and organophosphate flame retardants (PFRs) in indoor dust has raised health concerns, only very few epidemiological studies have assessed their impact on human health. Inhalation of dust is one of the exposure routes of FRs, especially in children and can be hazardous for the respiratory health. Moreover, PFRs are structurally similar to organophosphate pesticides, which have been associated with allergic asthma. Thus, we investigated whether the concentrations of PFRs and PBDEs in indoor dust are associated with the development of childhood asthma. We selected 110 children who developed asthma at 4 or at 8 years old and 110 matched controls from a large prospective birth cohort (BAMSE – Barn, Allergy, Milieu Stockholm Epidemiology). We analyzed the concentrations of 7 PFRs and 21 PBDEs in dust collected around 2 months after birth from the mother's mattress. The abundance rank in dust was as follows: TBOEP?TPHP>mmp‐TMPP>EHDPHP~TDCIPP>TCEP~TCIPP~BDE‐209?BDE‐99>BDE‐47>BDE‐153>BDE‐183>BDE‐100. There was no positive association between the FRs in mattress dust and the development of childhood asthma. In contrast, dust collected from mattresses of the mothers of children who would develop asthma contained significant lower levels of TPHP and mmp‐TMPP. This study provides data on a wide range of PFRs and PBDEs in dust samples and development of asthma in children.  相似文献   

7.
A mechanistic model that considers particle dynamics and their effects on surface emissions and sorptions was developed to predict the fate and transport of phthalates in indoor environments. A controlled case study was conducted in a test house to evaluate the model. The model‐predicted evolving concentrations of benzyl butyl phthalate in indoor air and settled dust and on interior surfaces are in good agreement with measurements. Sensitivity analysis was performed to quantify the effects of parameter uncertainties on model predictions. The model was then applied to a typical residential environment to investigate the fate of di‐2‐ethylhexyl phthalate (DEHP) and the factors that affect its transport. The predicted steady‐state DEHP concentrations were 0.14 μg/m3 in indoor air and ranged from 80 to 46 000 μg/g in settled dust on various surfaces, which are generally consistent with the measurements of previous studies in homes in different countries. An increase in the mass concentration of indoor particles may significantly enhance DEHP emission and its concentrations in air and on surfaces, whereas increasing ventilation has only a limited effect in reducing DEHP in indoor air. The influence of cleaning activities on reducing DEHP concentration in indoor air and on interior surfaces was quantified, and the results showed that DEHP exposure can be reduced by frequent and effective cleaning activities and the removal of existing sources, though it may take a relatively long period of time for the levels to drop significantly. Finally, the model was adjusted to identify the relative contributions of gaseous sorption and particulate‐bound deposition to the overall uptake of semi‐volatile organic compounds (SVOCs) by indoor surfaces as functions of time and the octanol‐air partition coefficient (Koa) of the chemical. Overall, the model clarifies the mechanisms that govern the emission of phthalates and the subsequent interactions among air, suspended particles, settled dust, and interior surfaces. This model can be easily extended to incorporate additional indoor source materials/products, sorption surfaces, particle sources, and room spaces. It can also be modified to predict the fate and transport of other SVOCs, such as phthalate‐alternative plasticizers, flame retardants, and biocides, and serves to improve our understanding of human exposure to SVOCs in indoor environments.  相似文献   

8.
Young children spend a substantial part of their waking time in preschools. It is therefore important to reduce the load of hazardous semivolatile organic compounds (SVOCs) in the preschools’ indoor environment. The presence and levels of five SVOC groups were evaluated (1) in a newly built preschool, (2) before and after renovation of a preschool, and (3) in a preschool where SVOC-containing articles were removed. The new building and the renovation were performed using construction materials that were approved with respect to content of restricted chemicals. SVOC substance groups were measured in indoor air and settled dust and included phthalates and alternative plasticizers, organophosphate esters (OPEs), brominated flame retardants, and bisphenols. The most abundant substance groups in both indoor air and dust were phthalates and alternative plasticizers and OPEs. SVOC concentrations were lower or of the same order of magnitude as those reported in comparable studies. The relative Cumulative Hazard Quotient (HQcum) was used to assess the effects of the different reduction measures on children's SVOC exposure from indoor air and dust in the preschools. HQcum values were low (1.0–6.1%) in all three preschools and decreased further after renovation and article substitution. The SVOCs concentrations decreased significantly more in the preschool renovated with the approved building materials than in the preschool where the SVOC-containing articles were removed.  相似文献   

9.
Filter forensics is a promising indoor air investigation technique involving the analysis of dust which has collected on filters in central forced‐air heating, ventilation, and air conditioning (HVAC) or portable systems to determine the presence of indoor particle‐bound contaminants. In this study, we summarize past filter forensics research to explore what it reveals about the sampling technique and the indoor environment. There are 60 investigations in the literature that have used this sampling technique for a variety of biotic and abiotic contaminants. Many studies identified differences between contaminant concentrations in different buildings using this technique. Based on this literature review, we identified a lack of quantification as a gap in the past literature. Accordingly, we propose an approach to quantitatively link contaminants extracted from HVAC filter dust to time‐averaged integrated air concentrations. This quantitative filter forensics approach has great potential to measure indoor air concentrations of a wide variety of particle‐bound contaminants. Future studies directly comparing quantitative filter forensics to alternative sampling techniques are required to fully assess this approach, but analysis of past research suggests the enormous possibility of this approach.  相似文献   

10.
The chlorinated organo-phosphate triesters, tris(2-chloroethyl)-phosphate (TCEP) and tris(monochloroisopropyl)-phosphate (TCPP), are employed in consumer articles for indoor usage, e.g. flame retardants and plasticizers in foam material as well as in paints, varnishes and wallpapers. As a result of this widespread usage, employing domestic dust as a matrix, both chemicals have been detected in the indoor environment. TCEP was present in 85% of a total of 983 samples, whereas TCPP was found in 60-90% of 436 cases (with levels ranging from 0.1 to 375 mg/kg). Since TCEP and TCPP residues in domestic dust are assumed to be condensates arising from primary sources, spot check analysis of various indoor materials was performed. The results show that soft foams, paints and wallpapers contained mainly TCEP, whereas in insulation and sealant foams high levels of TCPP were found. Moreover, TCEP can also be detected in indoor air in concentrations up to 6,000 ng/m3. On the basis of this data, we estimated the levels of indoor exposure via oral and inhalative ingestion.  相似文献   

11.
Resuspension of microbes in floor dust and subsequent inhalation by human occupants is an important source of human microbial exposure. Microbes in carpet dust grow at elevated levels of relative humidity, but rates of this growth are not well established, especially under changing conditions. The goal of this study was to model fungal growth in carpet dust based on indoor diurnal variations in relative humidity utilizing the time-of-wetness framework. A chamber study was conducted on carpet and dust collected from 19 homes in Ohio, USA and exposed to varying moisture conditions of 50%, 85%, and 100% relative humidity. Fungal growth followed the two activation regime model, while bacterial growth could not be evaluated using the framework. Collection site was a stronger driver of species composition (P = 0.001, R2 = 0.461) than moisture conditions (P = 0.001, R2 = 0.021). Maximum moisture condition was associated with species composition within some individual sites (P = 0.001-0.02, R2 = 0.1-0.33). Aspergillus, Penicillium, and Wallemia were common fungal genera found among samples at elevated moisture conditions. These findings can inform future studies of associations between dampness/mold in homes and health outcomes and allow for prediction of microbial growth in the indoor environment.  相似文献   

12.
This paper reports the abundance in indoor air and dust of eleven organophosphate esters and six phthalate esters. Both groups of these semi-volatile compounds are widely incorporated as additives into plastic materials used in the indoor environment, thus contributing to indoor exposure to industrial chemicals. Thirty sampling sites representing three different indoor environments (private homes, day care centers, and workplaces) in the Stockholm area, Sweden, were selected to obtain representative concentration profiles in both ambient air and settled dust. Eight of the target organophosphate esters and all six phthalate esters were found in both air and dust samples at all locations. The phthalate esters were more abundant than the organophosphate esters, typically ten times higher total concentrations. Especially interesting were the high levels of tributoxyethyl phosphate in the day care centers, the relatively high levels of chlorinated organophosphate esters in the air of workplaces and the overall high levels of diethylhexyl phthalate in dust. The air concentration profiles of the phosphate esters differed significantly between the three indoor environments, whereas the concentration profiles of the phthalate esters as well as their total concentrations were similar. The correlation between concentrations found in air and in dust was found to be weak. PRACTICAL IMPLICATIONS: Organophosphate esters and phthalate esters are commonly used as additives in numerous building materials and consumer products. The use of these compounds is increasing, and phosphate and phthalate esters are to be regarded as ubiquitous contaminants in the indoor environment. These compounds comprise a number of different compounds that have been associated with biologic effects in animal studies as well as in humans. Thus, it is of concern to increase the knowledge about human exposure of these compounds because of their presence in indoor air. In this paper, thirty indoor environments have been surveyed with respect to seventeen of the most abundant of these compounds.  相似文献   

13.
Phthalic acid esters and phosphororganic compounds (POC) are generally known as semivolatile organic compounds (SVOCs) and are frequently utilized as plasticizers and flame retardants in commercial products. In the indoor environment, both compound groups are released from a number of sources under normal living conditions and accumulate in air and dust. Therefore, inhalation of air and ingestion of house dust have to be considered as important pathways for the assessment of exposure in living habitats. Especially in the case of very young children, the oral and dermal uptake from house dust might be of relevance for risk assessment. A critical evaluation of indoor exposure to phthalates and POC requires the determination of the target compounds in indoor air and house dust as well as emission studies. The latter are usually carried out under controlled conditions in emission test chambers or cells. Furthermore, chamber testing enables the determination of condensable compounds by fogging sampling. In the case of automobiles, specific scenarios have been developed to study material emissions on a test stand or to evaluate the exposure of users while the vehicle is driving. In this review, results from several studies are summarized and compared for seven phthalic esters and eight POC. The available data for room air and dust differ widely depending on investigated compound and compartment. Room air studies mostly include only a limited number of measurements, which makes a statistical evaluation difficult. The situation is much better for house dust measurements. However, the composition of house dust is very inhomogeneous and the result is strongly dependent on the particle size distribution used for analysis. Results of emission studies are presented for building products, electronic equipment, and automobiles. Daily rates for inhalation and dust ingestion of phthalic esters and POC were calculated from 95-percentiles or maximum values. A comparison of the data with results from human biomonitoring studies reveals that only a small portion of intake takes place via the air and dust paths.  相似文献   

14.
Analysis of the dust from heating, ventilation, and air conditioning (HVAC) filters is a promising long‐term sampling method to characterize airborne particle‐bound contaminants. This filter forensics (FF) approach provides valuable insights about differences between buildings, but does not allow for an estimation of indoor concentrations. In this investigation, FF is extended to quantitative filter forensics (QFF) by using measurements of the volume of air that passes through the filter and the filter efficiency, to assess the integrated average airborne concentrations of total fungal and bacterial DNA, 36 fungal species, endotoxins, phthalates, and organophosphate esters (OPEs) based on dust extracted from HVAC filters. Filters were collected from 59 homes located in central Texas, USA, after 1 month of deployment in each summer and winter. Results showed considerable differences in the concentrations of airborne particle‐bound contaminants in studied homes. The airborne concentrations for most of the analytes are comparable with those reported in the literature. In this sample of homes, the HVAC characterization measurements varied much less between homes than the variation in the filter dust concentration of each analyte, suggesting that even in the absence of HVAC data, FF can provide insight about concentration differences for homes with similar HVAC systems.  相似文献   

15.
Toxic microbial secondary metabolites have been proposed to be related to adverse health effects observed in moisture-damaged buildings. Initial steps in assessing the actual risk include the characterization of the exposure. In our study, we applied a multi-analyte tandem mass spectrometry-based methodology on sample materials of severely moisture-damaged homes, aiming to qualitatively and quantitatively describe the variety of microbial metabolites occurring in building materials and different dust sample types. From 69 indoor samples, all were positive for at least one of the 186 analytes targeted and as many as 33 different microbial metabolites were found. For the first time, the presence of toxic bacterial metabolites and their co-occurrence with mycotoxins were shown for indoor samples. The bacterial compounds monactin, nonactin, staurosporin and valinomycin were exclusively detected in building materials from moist structures, while chloramphenicol was particularly prevalent in house dusts, including settled airborne dust. These bacterial metabolites are highly bioactive compounds produced by Streptomyces spp., a group of microbes that is considered a moisture damage indicator in indoor environments. We show that toxic bacterial metabolites need to be considered as being part of very complex and diverse microbial exposures in 'moldy' buildings. PRACTICAL IMPLICATIONS: Bacterial toxins co-occur with mycotoxins in moisture-damaged indoor environments. These compounds are measurable also in settled airborne dust, indicating that inhalation exposure takes place. In attempts to characterize exposures to microbial metabolites not only mycotoxins but also bacterial metabolites have to be targeted by the analytical methods applied. We recommend including analysis of samples of outdoor air in the course of future indoor assessments, in an effort to better understand the outdoor contribution to the indoor presence of microbial toxins. There is a need for a sound risk assessment concerning the exposure to indoor microbial toxins at concentrations detectable in moisture-damaged indoor environments.  相似文献   

16.
Occurrence of endocrine-disrupting chemicals in indoor dust   总被引:5,自引:0,他引:5  
Human exposure to indoor dust enriched with endocrine-disrupting chemicals released from numerous indoor sources has been a focus of increasing concern. Longer residence times and elevated contaminant concentrations in the indoor environment may increase chances of exposure to these contaminants by 1000-fold compared to outdoor exposure. To investigate the occurrence of semi-volatile endocrine-disrupting chemicals, including PBDEs (polybrominated diphenyl ethers), PCBs (polychlorinated biphenyls), phthalates, pyrethroids, DDT (dichlorodiphenyltrichloroethane) and its metabolites, and chlordanes, indoor dust samples were collected from household vacuum cleaner bags provided by 10 apartments and 1 community hall in Davis, California, USA. Chemical analyses show that all indoor dust samples are highly contaminated by target analytes measured in the present study. Di-(2-ethylhexyl)phthalate was the most abundant (104-7630 microg/g) in all samples and higher than other target analytes by 2 to 6 orders of magnitude. PBDEs were also found at high concentrations (1780-25,200 ng/g). Although the use of PCBs has been banned or restricted for decades, some samples had PCBs at levels that are considered to be concerns for human health, indicating that the potential risk posed by PCBs still remains high in the indoor environment, probably due to a lack of dissipation processes and continuous release from the sources. Although the use of some PBDEs is being phased out in some parts of the U.S., this trend may apply to PBDEs as well. We can anticipate that exposure to PBDEs will continue as long as the general public keeps using existing household items such as sofas, mattresses, and carpets that contain PBDEs. This study provides additional information that indoor dust is highly contaminated by persistent and endocrine-disrupting chemicals.  相似文献   

17.
The determinants of the temporal variability of indoor dust concentrations of semivolatile organic compounds (SVOCs) remain mostly unexplored. We examined temporal variability of dust concentrations and factors affecting dust concentrations for a wide range of SVOCs. We collected dust samples three times from 29 California homes during a period of 22 months and quantified concentrations of 47 SVOCs in 87 dust samples. We computed intraclass correlation coefficients (ICCs) using three samples collected within the same house. We calculated correlation coefficients (r) between two seasons with similar climate (spring and fall) and between two seasons with opposite climate (summer and winter). Among 26 compounds that were detected in more than 50% of the samples at all three visits, 20 compounds had ICCs above 0.50 and 6 compounds had ICCs below 0.50. For 19 out of 26 compounds, correlation coefficients between spring and fall (r = 0.48-0.98) were higher than those between summer and winter (r = 0.09-0.92), implying seasonal effects on dust concentrations. Our study showed that within-home temporal variability of dust concentrations was small (ICC > 0.50) for most SVOCs, but dust concentrations may vary over time for some SVOCs with seasonal variations in source rates, such as product use.  相似文献   

18.
Abstract In the present study, we modified an existing surface wipe sampling method for lead and other heavy metals to create a protocol to collect fungi in floor dust followed by real‐time quantitative PCR (qPCR)‐based detection. We desired minimal inconvenience for participants in residential indoor environmental quality and health studies. Accuracy, precision, and method detection limits (MDLs) were investigated. Overall, MDLs ranged from 0.6 to 25 cell/cm2 on sampled floors. Overall measurement precisions expressed as the coefficient of variation because of sample processing and qPCR ranged 6–63%. Median and maximum fungal concentrations in house dust in study homes in Visalia, Tulare County, California, were 110 and 2500 cell/cm2, respectively, with universal fungal primers (allergenic and nonallergenic species). The field study indicated samplings in multiple seasons were necessary to characterize representative whole‐year fungal concentrations in residential microenvironments. This was because significant temporal variations were observed within study homes. Combined field and laboratory results suggested this modified new wipe sampling method, in conjunction with growth‐independent qPCR, shows potential to improve human exposure and health studies for fungal pathogens and allergens in dust in homes of susceptible, vulnerable population subgroups.

Practical Implications

Fungi are ubiquitous in indoor and outdoor environments, and many fungi are known to cause allergic reactions and exacerbate asthma attacks. This study established—by modifying an existing—a wipe sampling method to collect fungi in floor dust followed by real‐time quantitative PCR (qPCR)‐based detection methodologies. Results from this combined laboratory and field assessment suggested the methodology’s potential to inform larger human exposure studies for fungal pathogens and allergens in house dust as well as epidemiologic studies of children with asthma and older adults with chronic respiratory diseases.
  相似文献   

19.
Indoor dust samples cannot always be analyzed immediately after collection. However, little information is currently available on how storage conditions may affect measurements. This study was designed to determine how sample storage conditions may affect the concentration of semi‐volatile organic compounds (SVOCs) in the dust. A composite dust was prepared using a Standard Reference Material (SRM 2585) with real indoor dust samples. The composite dust was stored in various types of packaging, at different temperatures (?18°C, 5°C, 20°C, and 35°C), and in different light conditions. The concentration of SVOCs was measured after various storage durations. No effect on SVOC concentrations was observed for the composite dust stored in an amber glass vial at ?18°C for 36 months. At 5°C, 20°C, and 35°C, losses occurred for the more volatile compounds. The experimental storage conditions clearly showed that temperature and duration affected the concentrations of SVOCs in the composite dust. The type of packaging material (polyethylene zip bag or polyethylene garbage bag) did not seem to have a systematic effect on the preservation of SVOCs in the composite dust. Maximum storage duration times are proposed for each compound at various temperatures. For most compounds, samples can be stored for 2 months at 20°C. For samples that cannot be analyzed immediately, we recommend to store them in the dark at ?18°C to ensure a good recovery of all tested compounds.  相似文献   

20.
Organophosphate esters are used as additives in flame retardants and plasticizers, and they are ubiquitous in the indoor environment. Phosphorus flame retardants (PFRs) are present in residential dust, but few epidemiological studies have assessed their impact on human health. We measured the levels of 11 PFRs in indoor floor dust and multi‐surface dust in 182 single‐family dwellings in Japan. We evaluated their correlations with asthma and allergies of the inhabitants. Tris(2‐butoxyethyl) phosphate was detected in all samples (median value: 580 μg/g in floor dust, 111 μg/g in multi‐surface dust). Tris(2‐chloro‐iso‐propyl) phosphate (TCIPP) was detected at 8.69 μg/g in floor dust and 25.8 μg/g in multi‐surface dust. After adjustment for potential confounders, significant associations were found between the prevalence of atopic dermatitis and the presence of TCIPP and tris(1,3‐dichloro‐2‐propyl) phosphate in floor dust [per log10‐unit, odds ratio (OR): 2.43 and 1.84, respectively]. Tributyl phosphate was significantly associated with the prevalence of asthma (OR: 2.85 in floor dust, 5.34 in multi‐surface dust) and allergic rhinitis (OR: 2.55 in multi‐surface dust). PFR levels in Japan were high compared with values reported previously for Europe, Asia‐Pacific, and the USA. Higher levels of PFRs in house dust were related to the inhabitants' health status.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号