首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The aim of this work was to determine important dosimetric characteristics of several types of the most interesting tissue-equivalent thermoluminescent detectors (TLDs). Special attention was given to the determination of energy dependence for medium and low energy X rays. The following types of TLDs were investigated: (a) two new types based on lithium borate: Li2B4O7:Cu,In and Li,B4O7:Cu,In,Ag; (b) two types of the recently developed highly sensitive LiF:Mg,Cu,P material: TLD-700H and GR 200A and (c) two well known types of LiF:Mg,Ti detectors: TLD-100 and TLD-700. In order to determine their photon energy response characteristics, TLDs previously calibrated with 137Cs gamma rays were simultaneously irradiated with X ray beams in the range of effective energies between 33 and 116 keV. Measured energy responses (relative to air), normalised to those to 137Cs photons were compared with calculated data. Although the deviations of the measured data from the 'theoretical' predictions are different for all the investigated TLDs, there is no large difference in 'tissue-equivalency' between them.  相似文献   

2.
This work presents an extensive study on Monte Carlo radiation transport simulation and thermoluminescent (TL) dosimetry for characterising mixed radiation fields (neutrons and photons) occurring in nuclear reactors. The feasibility of these methods is investigated for radiation fields at various locations of the Portuguese Research Reactor (RPI). The performance of the approaches developed in this work is compared with dosimetric techniques already existing at RPI. The Monte Carlo MCNP-4C code was used for a detailed modelling of the reactor core, the fast neutron beam and the thermal column of RPI. Simulations using these models allow to reproduce the energy and spatial distributions of the neutron field very well (agreement better than 80%). In the case of the photon field, the agreement improves with decreasing intensity of the component related to fission and activation products. (7)LiF:Mg,Ti, (7)LiF:Mg,Cu,P and Al(2)O(3):Mg,Y TL detectors (TLDs) with low neutron sensitivity are able to determine photon dose and dose profiles with high spatial resolution. On the other hand, (nat)LiF:Mg,Ti TLDs with increased neutron sensitivity show a remarkable loss of sensitivity and a high supralinearity in high-intensity fields hampering their application at nuclear reactors.  相似文献   

3.
The characteristics of thermoluminescence dosemeters (TLDs) regarding the determination of photon and neutron absorbed doses were investigated in a thermal neutron beam. Harshaw TLD-100 (LiF:Mg,Ti) and TLD-700 (7LiF:Mg,Ti) were compared with similar materials from Solid Dosimetric Detector and Method Laboratory (People's Republic of China). Harshaw TLD-700H (7LiF:Mg,Cu,P) and aluminium oxide (Al2O3:Mg,Y) from Hungary were also considered for photon dose measurement. The neutron sensitivity of the investigated materials was measured and found to be consistent with values reported by other authors. A comparison was made between the TL dose measurements and results obtained via conventional methods. An agreement within 20% was obtained, which demonstrates the ability of TLD for measuring neutron and photon doses in a mixed field, using careful calibration procedures and determining the neutron sensitivity for the usage conditions.  相似文献   

4.
Recently, two new types of 'tissue equivalent' thermoluminescent detectors (TLDs) have aroused attention: LiF:Mg,Cu,Na,Si and Li2B4O7:Cu,Ag,P. In this work the characteristics of both detectors were compared with the characteristics of the well-known type LiF:Mg,Ti detector, TLD-100. The following properties were investigated: the glow curve structures, relative sensitivity, batch homogeneity and uniformity, detection threshold, reproducibility of the response, linearity in the wide dose range and fading. Also, the energy dependence for medium and low energy X rays was determined in the range of mean energies between 33 and 116 keV. The results confirmed 'tissue equivalency' of both new types in the investigated range of photon energies. LiF:Mg,Cu,Na,Si detector has very high sensitivity (approximately 75 times higher than that of TLD-100) and is convenient for use in a very low range of doses. Li2B4O7:Cu,Ag,P detector shows some improvements in comparison with the previously prepared types of lithium borate. The most important is the five times higher sensitivity than that of TLD-100. This detector is also very promising, especially in medical dosimetry.  相似文献   

5.
The aim of this work was to determine energy dependence characteristics in terms of values of the personal dose equivalent, HP(10). The following types of thermoluminescent detectors (TLDs) were investigated: (a) two new types based on lithium borate, Li2B4O7:Cu,In and Li2B4O7:Cu,In,Ag; (b) two types based on the highly sensitive material LiF:Mg,Cu,P, TLD-700H and GR 200A; (c) two well-known types of LiF:Mg,Ti detector, TLD-100 and TLD-700 and (d) highly sensitive Al2O3:C detectors. TLDs previously calibrated with 137Cs gamma rays were simultaneously irradiated with X ray beams in the range of mean energies between 33 and 116 keV. The irradiations were performed with detectors in polymethyl methacrylate (PMMA) holders placed on a 30 cm x 30 cm x 15 cm water phantom with PMMA walls (ISO phantom). Measured energy responses were compared with calculated data for HP(10) values. The results confirmed the satisfactory tissue equivalent characteristics of all investigated TLDs except Al2O3:C, which (due to its large energy dependence) is suitable for personal dosimetry only with an appropriate filter.  相似文献   

6.
(6)LiF:Mg,Cu,P and (7)LiF:Mg,Cu,P glass-rod thermoluminescent dosemeters (TLDs) were used for measurements of out-of-field photon and neutron doses produced by Varian iX linear accelerator. Both TLDs were calibrated using 18-MV X-ray beam to investigate their dose-response sensitivity and linearity. CR-39 etch-track detectors (Luxel+, Landauer) were employed to provide neutron dose data to calibrate (6)LiF:Mg,Cu,P TLDs at various distances from the isocentre. With cadmium filters employed, slow neutrons (<0.5 eV) were distinguished from fast neutrons. The average in-air photon dose equivalents per monitor unit (MU) ranged from 1.5±0.4 to 215.5±94.6 μSv at 100 and 15 cm from the isocentre, respectively. Based on the cross-calibration factors obtained with CR-39 etch-track detectors, the average in-air fast neutron dose equivalents per MU range from 10.6±3.8 to 59.1±49.9 μSv at 100 and 15 cm from the isocentre, respectively. Contribution of thermal neutrons to total neutron dose equivalent was small: 3.1±7.2 μSv per MU at 15 cm from the isocentre.  相似文献   

7.
Photon energy response of MTS-N (LiF:Mg,Ti) detectors (TLD Poland) and of MTS-N detectors sensitised with 200 Gy of 60Co gamma rays, followed by UV irradiation (sMTS-N), has been determined using X rays with narrow energy spectra, in the energy range from 20 to 300 keV. The over-response of LiF:Mg,Ti detectors for X rays (relative TL efficiency eta = 1.1) can be explained as an ionisation density effect. Low energy X rays produce short electron tracks, which locally deposit a high radiation dose and, consequently, lead to an enhanced (supralinear) response. This over-response has not been observed in sensitised MTS-N where supralinearity in the response after gamma ray doses above 1 Gy is not seen. Using the dose-response curves measured for MTS-N detectors after 137Cs gamma ray irradiation and local doses calculated using Monte Carlo generated electron tracks, it was possible to predict the relative TL effectiveness for different X ray energies. The calculation procedure can be applied to predict the photon energy response of LiF:Mg,Ti detectors in an arbitrary photon field.  相似文献   

8.
Absorbed dose rate measurements of a 50 kV(p) handheld X-ray probe source in a water phantom are described. The X-ray generator is capable of currents of up to 40 microA, and is designed for cranial brachytherapy and intraoperative applications with applicators. The measurements were performed in a computer-controlled water phantom in which both the source and the detectors are mounted. Two different LiF thermoluminescence dosemeter (TLD) phosphors were employed for the measurements, MTS-N (LiF:Mg,Ti) and MCP-N (LiF:Mg,Cu,P). Two small ionisation chambers (0.02 and 0.0053 cm(3)) were also employed. The TLDs and chambers were positioned in watertight mounts made of water-equivalent plastic. The chambers were calibrated in terms of air-kerma rate, and conventional protocols were used to convert the measurements to absorbed dose rate. The TLDs were calibrated at National Institute of Standards and Technology (NIST) in terms of absorbed dose rate using a (60)Co teletherapy beam and narrow-spectrum X-ray beams. For the latter, absorbed dose was inferred from air-kerma rate using calculated air-kerma-to-dose conversion factors. The reference points of the various detectors were taken as the center of the TLD volumes and the entrance windows of the ionisation chambers. Measurements were made at distances of 3-45 mm from the detector reference point to the source center. In addition, energy dependence of response measurements of the TLDs used was made using NIST reference narrow spectrum X-ray beams. Measurement results showed reasonable agreement in absorbed dose rate determined from the energy dependence corrected TLD readings and from the ionisation chambers. Volume averaging effects of the TLDs at very close distances to the source were also evident.  相似文献   

9.
Sintered LiF:Mg,Cu,Na,Si thermoluminescence (TL) pellets have been developed for application in radiation dosimetry. LiF:M,Cu,Na,Si TL pellets were made from TL powders using a sintering process, that is, pressing and heat treatment. These pellets have a diameter of 4.5 mm, and a thickness of 0.8 mm are blue in colour and have a mass of 28 mg each. After 400 pellets had been produced they were irradiated with 137Cs gamma radiation and samples having a sensitivity within a +/-5% standard deviation were selected for experimental use. In the present study, the physical and dosimetric properties of LiF:Mg,Cu,Na,Si TL pellets were investigated for their emission spectrum, dose response, energy response and fading characteristics. Photon irradiation for the experiments was carried out using X ray beams and a 137Cs gamma source at the Korea Atomic Energy Research Institute (KAERI). The average energies and the dose were in the range of 20-662 keV and 10(-6) - 10(2) Gy respectively. The glow curves were measured with a manual type thermoluminescence dosimetry reader (system 310, Teledyne) at a constant nitrogen flux and a linear heating rate. For a constant heating rate of 5 degrees C.s(-1). the main dosimetric peak of the glow curve appeared at 234 degrees C, its activation energy was 2.34 eV and the frequency factor was 1.00 x 10(23). The TL emission spectrum appeared at the blue region centred at 410 nm. A linearity of photon dose response was maintained up to 100 Gy. The photon energy responses relative to the 137Cs response were within +/-20% in the overall photon energy region. No fading of the TL sensitivity of the pellets stored at room temperature was found over the course of a year. Therefore LiF:Mg,Cu,Na,Si TL pellets can be used for personal dosimetry, but more research is needed to improve the characteristics for repeated use.  相似文献   

10.
A new method of thermoluminescence dosimetry of densely ionising radiation based on the ratio of different efficiency-LET functions of three thermoluminescent detectors (TLDs) has been developed. The applied TLD types are: MTS-7 ((7)LiF:Mg,Ti), MCP-7 ((7)LiF:Mg,Cu,P) and MTT-7 (a newly developed (7)LiF:Mg,Ti with modified activator composition and increased response to high-LET radiation). The tests of this method, performed with high-energy ion beams at the HIMAC accelerator within the ICCHIBAN project, proved that good agreement with the true dose values may be achieved even in very complicated mixed fields. The proposed method will be applied for analysis of several thousand TLDs used for the determination of organ doses in an anthropomorphic phantom orbiting outside the International Space Station within the MATROSHKA experiment.  相似文献   

11.
LiF:Mg,Cu,P 'pin worms': miniature detectors for brachytherapy dosimetry   总被引:5,自引:0,他引:5  
Dose measurements in brachytherapy 192Ir implants are often difficult due to large dose gradients and complex photon spectra. Therefore, tissue-equivalent detectors with a high spatial resolution, such as the highly promising LiF:Mg,Cu,P thermoluminescent detectors (TLDs) are required. It was the aim of the present work to ascertain if miniature LiF:Mg,Cu,P TLDs can effectively measure the dose distribution around 192Ir implants. 'Pin worm' TLDs (type MCP, diameter 0.6 mm, length 2 mm) were compared with GR-200R (SSDL, Beijing) rods cut in half. The TLDs were tested for reproducibility and energy dependence using high dose rate (HDR) and low dose rate (LDR) brachytherapy units. 192Ir measurements were performed in a tissue equivalent phantom accommodating hollow needles and catheters routinely used in brachytherapy. Pin worms had an average reproducibility of less than +/-2% (1 SD) and a detection limit of less than 10 microGy. The small dimensions of the pin worms allowed their placement within brachytherapy needles and catheters. The measured relative dose distribution was in good agreement with the predictions of a computerised treatment planning system (ADAC Pinnacle); however, limitations in the TLD energy correction did not allow for absolute dose comparison.  相似文献   

12.
The response of thermoluminescence dosemeters (TLDs) to light, in various conditions, has been studied. TLD cards containing both conventional lithium fluoride (LiF:Mg,Ti) and the high-sensitivity material LiF:Mg,Cu,P were available, so permitting a comparison between the two types. Also available for the tests were Harshaw(TM) extremity EXT-RAD (LiF:Mg,Cu,P) dosemeters. The LiF:Mg,Ti body TLD cards and the EXT-RAD extremity dosemeters both showed some response to fluorescent light, while the LiF:Mg,Cu,P cards showed no significant response. It is therefore concluded that LiF:Mg,Cu,P body cards need no special precautions to protect them from the effects of light. For LiF:Mg,Ti cards and extremity dosemeters, effects are small, but steps to avoid excessive light exposure should be considered.  相似文献   

13.
Measurements of the response of thermoluminescent (TL) detectors after gamma ray doses high enough to observe signal saturation provide input to microdosimetric models which relate this gamma-ray response with the energy response after low doses of photons (gamma rays and low-energy X rays) and after high-LET irradiation. To measure their gamma ray response up to saturation, LiF:Mg,Ti (MTS-7 and MTT), LiF:Mg,Cu,P (MCP-7), CaSO4:Dy (KCD) and Al2O3:C detectors were irradiated with 60Co gamma rays over the range 1-5000 Gy. The X-ray photon energy response and TL efficiency (relative to gamma rays) after doses of beta rays and alpha particles, were also measured, for CaSO4:Dy and for Al2O3:C. Microdosimetric and track structure modelling was then applied to the experimental data. In a manner similar to LiF:Mg,Cu,P, the experimentally observed under response of alpha-Al2O3:C to X rays <100 keV, compared with cross-section calculations, is explained as a microdosimetric effect caused by the saturation of response of this detector without prior supralinearity (saturation of traps along the tracks). The enhanced X-ray photon energy response of CaSO4:Dy is related to the supralinearity observed in this material after high gamma ray doses, similarly to that in LiF:Mg,Ti. The discussed model approaches support the general rule relating dose-, energy- and ionisation density-responses in TL detectors: if their gamma ray response is sublinear prior to saturation, the measured photon energy response is lower, and if it is supralinear, it may be higher than that expected from the calculation of the interaction cross sections alone. Since similar rules have been found to apply to other solid-state detector systems, microdosimetry may offer a valuable contribution to solid-state dosimetry even prior to mechanistic explanations of physical phenomena in different TL detectors.  相似文献   

14.
The energy response of standard (TLD-100) and high-sensitivity (TLD-100H) LiF thermoluminescence dosemeters (TLDs) has been studied for photon beams with mean energies from about 25 keV to 1100 keV. Canadian primary standards for air kerma were used to establish the air kerma rates for each of the photon beams. TLDs were mounted in a PMMA holder and the air kerma response was measured as a function of energy. The EGSnrc Monte Carlo code was used to model the TLD holder and calculate the absorbed dose to the TLD chip per unit air kerma for each beam. The measured and calculated results were combined to obtain the intrinsic dose response of the TLD chip. Broadly, our results are consistent with existing data, which show a marked difference in the energy dependence of the two materials. However, the precision of our measurements (standard uncertainty of about 0.6%) has permitted the identification of features that have not been noted before. In particular, the energy dependence of the two materials is quite different in the important energy region delimited by 137Cs and 60Co gamma rays.  相似文献   

15.
This paper presents the characteristics of two high-sensitive LiF:Mg,Cu,P thermoluminescence detectors (TLDs) named MCP-600D and MCP-700D [thermoluminescence detector (TLD) Poland]. Furthermore, the applicability of both detectors used as a paired system for photoneutron detection in a high-energy photon field at a linear accelerator is shown. For MCP-600D and MCP-700D, the batch homogeneity is within 22 and 14%, respectively (2 SD). Correction for the individual response of each TLD leads to a reproducibility of 5 and 4%, respectively Both TLD types reveal a linear detector response to dose up to 4 Gy. The energy dependence for both is within 2% for 4 and 6 MV photons. For a 15 MV photon beam, the MCP-600D shows a higher response (10%); compared with the MCP-700D (2%). The MCP-600D is capable of detecting extra doses due to photoneutrons in a 15 MV photon exposure; however, the signal for an open field of the used linear accelerator is in the order of the reproducibility. Using a kind of albedo technique allows detection of photoneutrons in the open photon field anyhow. The neutron detection limit is 10 microGy neutron dose per 1 Gy photon dose. Reproducibility of the TLDs, however, requires more than 10 detectors to determine results with an uncertainty of <5%.  相似文献   

16.
The photon energy response of different RADOS (Mirion Technologies) personal dosemeters with MTS-N (LiF:Mg,Ti) and MCP-N (LiF:Mg,Cu,P) thermoluminescence (TL) detectors was investigated. Three types of badges were applied. The irradiation with reference photon radiation qualities N (the narrow spectrum series), and S-Cs and S-Co nuclide radiation qualities, specified in ISO 4037 [International Organization for Standardization (ISO). X and gamma reference radiations for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy. ISO 4037. Part 1-4 (1999)], in the energy range of 16-1250 keV, were performed at the Dosimetry Laboratory Seibersdorf. The results demonstrated that a readout of a single MTS-N or MCP-N detector under the Al filter can be used to determine Hp(10) according to requirements of IEC 61066 [International Electrotechnical Commission (IEC). Thermoluminescence dosimetry systems for personal and environmental monitoring. International Standard IEC 61066 (2006)] for TL systems for personal dosimetry. The new RADOS badge with the experimental type of a holder (i.e. Cu/Al filters) is a very good tool for identifying the radiation quality (photon energy).  相似文献   

17.
The Health Protection Agency is changing from using detectors made from 7LiF:Mg,Ti in its photon/electron personal dosemeters, to 7LiF:Mg,Cu,P. Specifically, the Harshaw TLD-700H card is to be adopted. As a consequence of this change, the dosemeter holder is also being modified not only to accommodate the shape of the new card, but also to optimize the photon and electron response characteristics of the device. This redesign process was achieved using MCNP-4C2 and the kerma approximation, electron range/energy tables with additional electron transport calculations, and experimental validation, with different potential filters compared; the optimum filter studied was a polytetrafluoroethylene disc of diameter 18 mm and thickness 4.3 mm. Calculated relative response characteristics at different angles of incidence and energies between 16 and 6174 keV are presented for this new dosemeter configuration and compared with measured type-test results. A new estimate for the energy-dependent relative light conversion efficiency appropriate to the 7LiF:Mg,Cu,P was also derived for determining the correct dosemeter response.  相似文献   

18.
The simulation of response of a new passive area dosemeter for measuring ambient dose equivalent H*(10) for photons has been performed using the Monte Carlo code MCNP and experimentally determined responses of LiF:Mg,Ti and LiF:Mg,Cu,P thermoluminescent (TL) detectors for hard-filtered X-ray spectra from 20 to 300 keV and for 137Cs and 60Co gamma radiation. Relative TL efficiency for both types of detectors, determined in experiments with bare detectors and similar Monte Carlo simulations, compared favourably with prediction of microdosimetric models for proposed microdosimetric target sizes in the range of 20-40 nm. The concluding verification experiment showed small deviations between measured and simulated dosemeter energy response values in the range of a few percent.  相似文献   

19.
The effect of a high level of ambient (222)Rn gas on thermoluminescence dosemeters (TLDs) is examined. Groups of LiF:Mg,Ti and CaF(2):Dy TLDs were exposed to (222)Rn under controlled environmental conditions over ~7 d using a luminous (226)Ra aircraft dial. LiF:Mg,Ti TLDs were tested bare, and both types were tested mounted in cards used for environmental dosimetry and mounted in cards enclosed in plastic badges. A passive continuous radon monitor was used to measure the (222)Rn level in the small chamber during the experiments. The data were analysed to determine the relationship between the integrated (222)Rn level and the TLD response. Although both LiF:Mg,Ti and CaF(2):Dy TLDs showed a strong response to (222)Rn, the badges prevented measurable radon detection by the TLDs within. The TLDs were not used to directly measure the radon concentration; rather, a correction for its influence was desired.  相似文献   

20.
A 2-D tissue-equivalent sheet-type dosemeter (NTL sheet) was developed using thermoluminescent material of LiF:Mg,Cu,P (NTL-250). The energy responses of the NTL sheet and NTL-250 powder were measured with 10-150 keV monoenergetic photons from synchrotron radiation at SPring-8. The sample was irradiated by a rotational method for the uniform irradiation with the narrow beam. Linearity of the NTL-250 was confirmed up to 2 Gy. Energy responses of the NTL sheet and NTL-250 powder were close to that of soft tissue. On the other hand, the BaSO(4) sheet, which has been used practically, showed the response that the sensitivity approximately 60 keV was 100 times higher than that for (60)Co gamma rays. Therefore the NTL sheet can be said to have excellent properties for dose measurements.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号