首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
PURPOSE: To investigate the effects of acetone or water based Gluma primers on bonding efficacy when applied to acid-etched wet, dry or rewetted dentin. MATERIALS AND METHODS: Shear bond strength (SBS, 24 hours) was measured on human dentin etched with 20% phosphoric acid gel and rinsed with water in the wet (blot dried), the conventional (2 seconds air blast), the dry (10 seconds air drying), and the rewetted stage (10 seconds air drying, remoistening and blot drying). The priming solution was either the original water based or an acetone based experimental Gluma primer. Cavity sealing performance and depth of resin impregnation were determined by solvent and by technique along the margins of 4.5 mm wide cylindrical dentin cavities with 90 degree cavosurface angle. RESULTS: The SBSs of the wet technique groups were approximately 18 MPa, irrespective of the primer solvent. Conventional drying gave an SBS almost as high (16.5 MPa). Rewetting was highly effective with acetone as the primer solvent. The dry techniques resulted in moderate (water) and poor (acetone) bond strengths. The cavity margins of acetone based primer treated specimens were consistently gap free with the wet technique. The other seven groups showed between two and six gaps in each group of six specimens. The resin impregnated layer (RIL) thicknesses were 12.5 microns approximately in the wet groups, and thus identical with the total depth of demineralization resulting from the 30-second etching. The alternative techniques showed significantly thinner RILs particularly in the dry groups (7.5 microns).  相似文献   

2.
Three-dimensional (3D) reconstruction from a single esophageal scanning position requires a stable relationship between the probe and the heart. The purpose of this study was to examine the movement of a transesophageal echocardiographic probe during 3D image acquisition. A new dual-axis multiplane probe was used that includes a miniature (6 x 6 x 9 mm) magnetic sensor in the tip. The sensor identifies the probe's 3D position and 3D orientation in space with respect to the location of a magnetic field generator placed beneath the subject. In vivo 3D scanning was performed in five anesthetized, ventilated dogs, with positional determinations acquired every 66 msec. Probe movement was estimated by computing the deviations of each x, y, and z position and orientation determination, compared with the average values during each 3D scan or cardiac cycle. Ten 3D scans were analyzed, involving 263 cardiac cycles and 2328 determinations. The range and SD of the translational movement of the transducer were 2.3 and 0.8 mm, 1.7 and 0.5 mm, and 2.4 and 0.7 mm in x, y, and z directions, respectively, during 3D scanning. Translational movement was more dominant than was rotational movement. Misregistration of three-dimensional reconstructions may be due to subtle probe movement. The ability to monitor probe movement may be helpful in optimizing 3D data sets.  相似文献   

3.
A microcytotoxicity assay has been used to determine the cytotoxic activity of anti-heart antibodies which we have previously shown to be present with greater frequencies and reactivities in patients with dilated cardiomyopathy (DCM) than in patients with ischaemic heart disease (IHD). Serum samples from 45 patients with DCM and 43 patients with IHD were screened against W1, a transformed human fetal cardiac cell line and also against EA.hy 926, an endothelial and IBR3, a fibroblast cell line. In the presence of complement, sera from 28 (62%) DCM patients showed killing of the W1 cell line as compared to sera from 13 (30%) of IHD patients (p < 0.005) and 3 (15%) of normal individuals. In contrast, only 1 patient with DCM showed killing of the endothelial cell line and 1 patient with IHD showed killing of the fibroblast cell line. These results provide evidence for a complement-dependent, antibody-mediated mechanism of damage to cardiac myocytes which may contribute to the pathogenesis of DCM.  相似文献   

4.
BACKGROUND: The positions, sizes, and shapes of ventricular septal defects (VSDs) can be difficult to assess by 2-dimensional echocardiography (2DE). Volume-rendered 3-dimensional echocardiography (3DE) can provide unique views of VSDs from the left ventricular (LV) side, allowing complete assessment of their circumference and spatial orientations to other anatomic structures. METHODS AND RESULTS: Seventeen experimentally created defects of various locations, sizes, and shapes were imaged and reconstructed in 9 explanted porcine hearts. From an en face projection, major and minor axis diameters of the defects were measured, and these data were compared with direct anatomic measurements. Optimal reconstructions of the VSDs were obtained in all heart specimens, accurately depicting their positions and shapes. The correlations between 3DE and anatomy for the VSD major and minor axis diameters were y=1.0x+0.3 (r=0.88, P<0.001) and y=1.0x-1.4 (r =0.89, P<0.001), respectively. Good agreement between the 2 methods was demonstrated for all measurements. Our experience from the in vitro model was then applied to patient studies. Optimal LV en face reconstructions were obtained in 45 of 51 patients, permitting detailed assessment of the positions, sizes, and shapes of the VSDs. In the 25 patients with comparative surgical measurements, the correlations between 3DE and surgery for the VSD major and minor axis diameters were y =0. 81x+2.1 (r=0.92, P<0.001) and y=0.73x+2.0 (r=0.91, P<0.001), respectively. Good agreement was demonstrated between measurements made by 3DE and those obtained at surgery. CONCLUSIONS: 3DE provides excellent visualization of various types of VSDs. From an LV en face projection, the positions, sizes, and shapes of VSDs can be accurately determined. Such precise imaging will be beneficial for surgical and catheter-based closure of difficult perimembranous and singular or multiple muscular VSDs.  相似文献   

5.
6.
RATIONALE AND OBJECTIVES: The purpose of this study was to assess the feasibility and accuracy of three-dimensional (3D) reconstruction techniques for digital subtraction angiography (DSA) in planning and evaluation of minimally invasive image-controlled therapy. MATERIALS AND METHODS: Using a standard, commercially available system, the authors acquired DSA images and corrected them for inherent distortions. They designed and implemented parallel and multiresolution versions of cone-beam reconstruction techniques to reconstruct high-resolution targeted volumes in a short period of time. Testing was performed on anatomically correct, calibrated in vitro models of a cerebral aneurysm. These models were used with a pulsatile circulation circuit to allow for blood flow simulation during DSA, computed tomographic (CT) angiography, and magnetic resonance (MR) angiography image acquisitions. RESULTS: The multiresolution DSA-based reconstruction protocol and its implementation allowed the authors to achieve reconstruction times and levels of accuracy for the volume measurement of the aneurysmal cavities that were considered compatible with actual clinical practice. Comparison with data obtained from other imaging modalities shows that, besides vascular tree depiction, the DSA-based true 3D technique provides volume estimates at least as good as those obtained from CT and MR angiography. CONCLUSION: The authors demonstrated the feasibility and potential of true 3D reconstruction for angiographic imaging with DSA. On the basis of the model testing, this work addresses both the timing and quantification required to support minimally invasive image-controlled therapy.  相似文献   

7.
Emotionally focused marital therapy (EFT), a marital therapy that particularly focuses on the creation of secure attachment, has proven in empirical studies to be effective for distressed couples. This paper discusses the application of EFT in couples where one or both of the partners have experienced significant trauma. EFT, in this context of trauma, incorporates the nine steps of conventional EFT and also encompasses the three stages of the "constructivist" self development theory of trauma treatment. This paper illustrates how the integration of EFT and trauma treatment can prove effective in treating not only relationship distress but also the individual symptoms of posttraumatic stress disorder (PTSD).  相似文献   

8.
OBJECTIVES: The purpose of this study was to improve three-dimensional echocardiographic reconstruction by developing an automated mechanism for integrating spark gap locating data with corresponding images in real time and to validate use of this mechanism for the measurement of left ventricular volume. BACKGROUND: Initial approaches to three-dimensional echocardiographic reconstruction were often limited by inefficient reconstructive processes requiring manual coordination of two-dimensional images and corresponding spatial locating data. METHODS: In this system, a single computer overlays the binary-encoded positional data on the two-dimensional echocardiographic image, which is then recorded on videotape. The same system allows images to be digitized, traced, analyzed and displayed in three dimensions. This system was validated by using it to reconstruct 11 ventricular phantoms (19 to 271 ml) and 11 gel-filled excised ventricles (21 to 236 ml) imaged in intersecting long- and short-axis views and by apical rotation. To measure cavity volume, a surface was generated by an algorithm that takes advantage of the full three-dimensional data set. RESULTS: Reconstructed cavity volumes agreed well with actual values: y = 0.96x + 2.2 for the ventricular phantoms in long- and short-axis views (r = 0.99, SEE = 2.7 ml); y = 0.95x + 2.9 for the phantoms, reconstructed by apical rotation (r = 0.99, SEE = 2.7 ml); and y = 0.99x + 0.11 ml for the excised ventricles (reconstructed in long- and short-axis views; r = 0.99, SEE = 5.9 ml). The mean difference between three-dimensional and actual volumes was 3% of the mean (3.0 ml) for the phantoms and 6% (4.6 ml) for the excised ventricles. Observer variability was 2.3% for the phantoms and 5.6% for the excised ventricles. Application to 14 normal subjects demonstrated feasibility of left ventricular reconstruction, which provided values for stroke volume that agreed well with an independent Doppler measure (y = 0.97x + 0.94; r = 0.95, SEE = 3.2 ml), with an observer variability of 4.9% (2.4 ml). CONCLUSIONS: A system has therefore been developed that automatically integrates locating and imaging data in no more time than the component two-dimensional echocardiographic scans. This system can accurately reconstruct ventricular volumes in vitro over a wide range and is feasible in vivo, thus laying the foundation for further applications. It has increased the efficiency of three-dimensional reconstruction and enhanced our ability to address clinical and research questions with this technique.  相似文献   

9.
Patients with diabetic amyotrophy may have an inflammatory vasculopathy and may obtain reversal of neurological deficits with immunosuppression. We present a patient with NIDDM, subacute onset of painful asymmetric polyradiculopathy, and unilateral enhancement of lumbar nerve roots on MRI. Clinical improvement and resolution of nerve root enhancement occurred with immunosuppression. We suggest, therefore, that nerve biopsy and gadolinum-enhanced lumbosacral MRI be performed in all patients presenting with diabetic amyotrophy. If nerve root enhancement is present or if nerve biopsy shows perivascular infiltrates, we recommend a trial of immunosuppression.  相似文献   

10.
1. Ischaemic cardiac preconditioning represents an important cardioprotective mechanism which limits myocardial ischaemic damage. The aim of this investigation was to assess the impact of dichloroacetate (DCA), a pyruvate dehydrogenase complex activator, on preconditioning. 2. Rat isolated hearts were perfused by use of the Langendorff technique, and were subjected to either preconditioning (3 x 4 or 3 x 6 min ischaemia) or continuous perfusion, followed by 30 min global ischaemia and 60 min reperfusion. DCA (3 mM) was either given throughout the protocol (pretreatment), during reperfusion only (post-treatment), or not at all. Throughout reperfusion mechanical performance was assessed as the rate-pressure product (RPP: left ventricular developed pressure x heart rate). 3. In non-preconditioned control hearts, mechanical performance was substantially (P < 0.001) depressed on reperfusion (the RPP after 60 min of reperfusion (RPP(t=60)) was 4,246+/-974 mmHg beats min(-1) compared to baseline value of 21,297+/-1,728 mmHg beats min(-1)). Preconditioning with either 3 x 4 min or 3 x 6 min cycles caused significant protection, as shown by enhanced recovery (RPP(t=60) = 7,818+/-1,138, P < 0.05, and 11,123+/-587 mmHg beats min(-1), P < 0.001, respectively). 4. Addition of DCA (3 mM) to hearts under baseline conditions significantly (P < 0.001) enhanced systolic function with an increased left ventricular developed pressure of 108+/-5 mmHg compared to 88.3+/-3.0 mmHg in the controls. 5. Pretreatment with 3 mM DCA had no effect on recovery of mechanical performance in the non-preconditioned hearts (RPP(t=60) = 3,640+/-1,235 mmHg beats min(-1)) while the beneficial effects of preconditioning were reduced in the preconditioned hearts (3 x 4 min: RPP(t=60) = 2,919+/-1,060 mmHg beats min(-1); 3 x 6 min: RPP(t=60) = 8,032+/-1,367 mmHg beats min(-1)). Therefore, DCA had increased the threshold for preconditioning. 6. By contrast, post-treatment of hearts with 3 mM DCA substantially improved recovery on reperfusion in all groups (RPP(t=60) = 5,827+/-1,328 (non-preconditioned), 14,022+/-3,743 (3 x 4 min; P < 0.01) and 23,219+/-1,374 (3 x 6 min; P < 0.001) mmHg beats min(-1)). 7. The results of the present investigation clearly show that pretreatment with DCA enhances baseline cardiac mechanical performance but increases the threshold for cardiac preconditioning. However, post-treatment with DCA substantially augments the beneficial effects of preconditioning.  相似文献   

11.
Generally, cardiac lesions with increased pulmonary blood flow demonstrate cardiomegaly, increased pulmonary vascular markings, and pulmonary congestion on the chest x-ray. These findings occur as a result of the following: 1. A left-to-right shunt or mixing lesion in which excess volume of blood flow causes dilation of cardiac chambers, resulting in the appearance of cardiomegaly, and in which increased pulmonary artery blood flow causes increased pulmonary vascular markings 2. Obstruction of blood flow that produces pulmonary venous hypertension and resultant pulmonary edema The next article in this series will address cardiac lesions with decreased pulmonary blood flow.  相似文献   

12.
The importance of the functional unit "bone-soft-tissue" for the treatment of bone defects is discussed. A division is made between non-vascular and vascular bone transport. The individual methods are explained and their clinical significance is illustrated partly using case material. In general, the best way to fill small defects in vital soft tissue is to use cancellous autografts. For bridging longer bone defects callus distraction is the method of first choice, but in individual cases vascularized bone transfer can be taken from the iliac crest or the fibula. Homo- or heterografts should only be used in cases where no autologic bone material is available or when there is not enough.  相似文献   

13.
BACKGROUND: The geometrical accuracy of conventional three-dimensional (3D) reconstruction methods for intravascular ultrasound (IVUS) data (coronary and peripheral) is hampered by the inability to register spatial image orientation and by respiratory and cardiac motion. The objective of this work was the development of improved IVUS reconstruction techniques. METHODS AND RESULTS: We developed a 3D position registration method that identifies the spatial coordinates of an in situ IVUS catheter by use of simultaneous ECG-gated biplane digital cinefluoroscopy. To minimize distortion, coordinates underwent pincushion correction and were referenced to a standardized calibration cube. Gated IVUS data were acquired digitally, and the spatial locations of the imaging planes were then transformed relative to their respective 3D coordinates, rendered in binary voxel format, resliced, and displayed on an image-processing workstation for off-line analysis. The method was tested by use of phantoms (straight tube, 360 degrees circle, 240 degrees spiral) and an in vitro coronary artery model. In vivo feasibility was assessed in patients who underwent routine interventional coronary procedures accompanied by IVUS evaluation. Actual versus calculated point locations were within 1.0 +/- 0.3 mm of each other (n = 39). Calculated phantom volumes were within 4% of actual volumes. Phantom 3D reconstruction appropriately demonstrated complex morphology. Initial patient evaluation demonstrated method feasibility as well as errors if respiratory and ECG gating were not used. CONCLUSIONS: These preliminary data support the use of this new method of 3D reconstruction of vascular structures with use of combined vascular ultrasound data and simultaneous ECG-gated biplane cinefluoroscopy.  相似文献   

14.
15.
Congenital cardiac anomalies cannot be merely classified as "less", "more", and "very" complex. However, postoperative prognosis is also determined by: the wide variability in severity of certain anomalies; their frequent association with other cardiac or non-cardiac malformations; age at the time of surgery; the era, mode and quality of initial and subsequent treatment. Chosen examples will illustrate how recent progress has altered prognosis. The role of early, specific and multidisciplinary care in an appropriate center is emphasized.  相似文献   

16.
Of 73 patients with congenital heart diseases (CHD), aged from 16 to 82 years, operated on in 1977-1998 yrs., there were 41 women and 32 men. Fourteen (19.6%) of patients were 60 years old or older. Complex CHD were revealed in 27 (37%) of patients, an ischemic heart disease-in 8 (11%). There were no intraoperative mortality. Complications have occurred in 2 patients. Late follow-up results (in terms from 4 months till 20.5 years) were studied in 71 patient. One patient died in 7 years because of another cause, the state of the rest of the patients is good or satisfactory.  相似文献   

17.
DiGeorge syndrome (DGS) is a congenital disease characterized by defects in organs and tissues that depend on contributions by cell populations derived from neural crest for proper development. A number of candidate genes that lie within the q11 region of chromosome 22 commonly deleted in DGS patients have been identified. Orthologues of the DGS candidate gene HIRA are expressed in the neural crest and in neural crest-derived tissues in both chick and mouse embryos. By exposing a portion of the premigratory chick neural crest to phosphorothioate end-protected antisense oligonucleotides, ex ovo, followed by orthotopic backtransplantation to the untreated embryos, we have shown that the functional attenuation of cHIRA in the chick cardiac neural crest results in a significantly increased incidence of persistent truncus arteriosus, a phenotypic change characteristic of DGS, but does not affect the repatterning aortic arch arteries, the ventricular function, or the alignment of the outflow tract.  相似文献   

18.
19.
Recent studies suggest good prospective accuracy for two-dimensional echocardiographic imaging of ventricular septal defects (VSD). We obtained two-dimensional images with high-frequency, high-resolution scanners from 36 patients proved by cardiac catheterization to have perimembranous VSD. In 20 patients, the VSD was an isolated lesion and in 16 it was associated with other forms of heart disease. VSDs were imaged in long-axis, apical four-chamber and subcostal echocardiographic views. The smallest VSD imaged was 2 mm in diameter on echo; the largest, 23 mm. The imaged size of VSDs was larger at end-diastole than at end-systole by paired t test on all views (all p less than 0.005). VSD size also varied between views, with no predictive relationship except between apical and subcostal four-chamber views in diastole (r = 0.71, p less than 0.005). This agreed with qualitative direct observations of an ellipsoid or irregularly shaped VSD in operated patients. Echocardiographically measured VSD size normalized for either aortic root size or for patient weight could be used to separate isolated VSDs with large shunts (Qp/Qs greater than 2:1) from those with small shunts. Review of 250 two-dimensional echocardiographic studies from patients proved not to have a VSD revealed 28 planes of imaging with false-positive VSD. None of the false-positive VSDs was imaged consistently on all views. Additionally, a "T" artifact (broadening of septal edges around a VSD) has been found to be a reliable marker of true VSD imaging. To best quantify VSD size and to avoid false-positive diagnoses, it is necessary to use multiple views and to consider the marked changes in VSD size that occur between diastole and systole.  相似文献   

20.
BACKGROUND: It is difficult to reconstruct a satisfactory ala. Axial frontonasal flap has been common in reconstruction of nasal tip. We modified this flap to reconstruct nasal ala. OBJECTIVE: A modified axial frontonasal flap was applied for reconstruction of complete unilateral alar defects in two patients. METHODS: Skin from an intact nasal tip covered the alar defect. The resulting defect in the nasal tip was covered with dorsal skin from the nose. Extended mucosa or a hinged nasolabial flap was used to line the mucosal side of the reconstructed ala. RESULTS: The outcome judged by shape, and texture, was satisfactory. This technique can be employed under field block. CONCLUSION: The modified frontonasal flap is one of the ideal techniques to reconstruct an entire nasal ala.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号