首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Hexavalent chromium (Cr(VI)) adsorption from aqueous solutions on magnetically modified multi-wall carbon nanotubes (M-MWCNT) and activated carbon (M-AC) was investigated. M-MWCNT and M-AC were prepared by co-precipitation method with Fe2+:Fe3+ salts as precursors. The magnetic adsorbents were characterized by X-ray diffraction (XRD), thermogravimetric analysis (TGA) and scanning electron microscope (SEM). The effects of amount of adsorbents, contact time, initial pH, temperature and the initial concentration of Cr(VI) solution were determined. The adsorption equilibrium, kinetics, thermodynamics and desorption of Cr(VI) were investigated. Equilibrium data fitted well with the Langmuir isotherm for both of the adsorbents. The theoretical adsorption capacities are 14.28 mg/g of M-MWCNT and 2.84 mg/g of M-AC. Cr(VI) adsorption kinetics was modeled with pseudo-second order model, intra-particle diffusion model and Bangham model. Thermodynamic parameters were calculated and ΔG°, ΔH° and ΔS° indicate that the adsorption of Cr(VI) onto M-MWCNT and M-AC was exothermic and spontaneous in nature. Results revealed that M-MWCNT is an easily separated effective adsorbent for Cr(VI) adsorption from aqueous solution.  相似文献   

2.
This work experimentally investigates Cr(VI) reduction to Cr(III) using waste scrap iron in the form of zerovalent iron (ZVI) collected from the mechanical workshop of the Institute, both in batch and continuous operation. The reduction of Cr(VI) to Cr(III) was found to be complete (~100%) depending on the experimental conditions. Lower pH values favour Cr(VI) reduction. Two concurrent reactions take place, that is reduction of Cr(VI) by Fe0 (ZVI) and by Fe2+ generated due to H+ corrosion of iron. Maximum around 22%, 11% and 2% Cr(III) remained dissolved in solution while the experiments were carried out at initial pH of 2, 4.67 and 7. Higher ZVI loading increases Cr(VI) reduction rate, however, consumption of iron is noted to be higher. The results indicate that the bed is exhausted rapidly at higher pH, initial Cr(VI) concentration and flow rate. This is attributable to predominance passivation of ZVI surface forming Cr(III)–Fe(III)‐oxide layer. SEM analysis of ZVI before and after the experiments confirms formation of passive oxide on iron surface is responsible for deterioration of Cr(VI) reduction efficiency due to its blanketing effect.  相似文献   

3.
《分离科学与技术》2012,47(2):290-299
A novel adsorbent: Fe2+-modified vermiculite was prepared in a two-step reaction. Adsorption experiments were carried out as a function of pH, contact time, and concentration of Cr(VI). It was found that Fe2+-modified vermiculite was particularly effective for the removal of Cr(VI) at pH 1.0. The adsorption of Cr(VI) reached equilibrium within 60 min, and the pseudo-second-order kinetic model best described the adsorption kinetics. The adsorption data follow the Langmuir model more than the Freundlich model. At pH 1.0, the maximum Cr(VI) sorption capacity (Q max ) was 87.72 mg · g?1. Desorption of Cr(VI) from Fe2+-modified vermiculite using NaOH treatment exhibited a higher desorption efficiency by more than 80%. The sorption mechanisms including electrostatic interaction and reduction were involved in the Cr (VI) removal. The results showed that Fe2+-modified vermiculite can be used as a new adsorbent for Cr(VI) removal which has a higher adsorption capacity and a faster adsorption rate.  相似文献   

4.
Macroporous copolymers of poly[(glycidyl methacrylate)‐co ‐(ethylene glycol dimethacrylate)] (PGME ) with various crosslinker (ethylene glycol dimethacrylate) concentrations and porosity parameters and additionally functionalized with hexamethylene diamine (PGME‐HD ) were tested as potential Cr(VI ) oxyanion sorbents from aqueous solutions. Kinetics of Cr(VI ) sorption was investigated in the temperature range 298–343 K and the results were fitted to chemical reaction and particle diffusion models. The Cr(VI ) sorption obeys the pseudo‐second‐order model with definite influence of pore diffusion. A temperature rise promotes chromium removal, with a maximum experimental uptake capacity of 4.21 mmol g?1 at 343 K for the sample with the highest amino group concentration. Equilibrium data were analysed with Langmuir, Freundlich and Temkin adsorption isotherm models. Thermodynamic parameters, i.e. Gibbs free energy (ΔG 0), enthalpy (ΔH 0) and entropy change (ΔS 0) and activation energy of sorption (E a), were calculated. The Cr(VI) adsorption onto PGME‐HD was found to be spontaneous and endothermic, with increased randomness in the system. Desorption experiments show that chromium anion sorption was reversible and the PGME‐HD sample GMA 60 HD was easily regenerated with 0.1 mol L?1 NaOH up to 90% recovery in the fourth sorption/desorption cycle. In the fifth cycle, a substantial sorption loss of 37% was observed. © 2016 Society of Chemical Industry  相似文献   

5.
Polyethyleneimine (PEI) modified palygorskite (Pal) was used for the adsorption of Cr(VI) in aqueous solution. The absorbent was characterized by Fourier transform infrared spectroscopy (FT-IR) and thermogravimetric analysis (TGA). Characterized results confirmed that the Pal has been successfully modified by PEI. The modification of PEI increased the Cr(VI) adsorption performance of the Pal by the adsorption combined reduction mechanism, and amino groups of the adsorbent play the main role in the enhanced Cr(VI) adsorption. The maximum adsorption capacity was 51.10 mg·g−1 at pH 4.0 and 25 °C. The adsorption kinetics of Cr(VI) on the adsorbent conforms to the Langmuir isotherm model. The maximum adsorption occurs at pH 3, and then the adsorption capacity of PEI-Pal was decreased with the increase of pH values. The adsorption kinetics of Cr(VI) on PEI-Pal was modeled with pseudo-second-order model. The addition of Cl, SO42− and PO43− reduced the Cr(VI) adsorption by competition with Cr(VI) for the active sites of PEI-Pal. The Cr(VI) saturated PEI-Pal can be regenerated in alkaline solution, and the adsorption capacity can still be maintained at 30.44 mg·g−1 after 4 cycles. The results demonstrate that PEI-Pal can be used as a potential adsorbent of Cr(VI) in aqueous solutions.  相似文献   

6.
Poly(ethylene glycol dimethacrylate‐1‐vinyl‐1,2,4‐triazole) [poly(EGDMA‐VTAZ)] beads (average diameter = 150–200 μm) were prepared by copolymerizing ethylene glycol dimethacrylate (EGDMA) with 1‐vinyl‐1,2,4‐triazole (VTAZ). Poly(EGDMA‐VTAZ) beads were characterized by swelling studies and scanning electron microscope (SEM). The adsorption of Cr(VI) from solutions was carried at different contact times, Cr(VI) concentrations, pH, and temperatures. High adsorption rates were achieved in about 240 min. The amount of Cr(VI) adsorbed increased with increasing concentration and decreasing pH and temperature. The intraparticle diffusion rate constants at various temperatures were calculated. Adsorption isotherms of Cr(VI) onto poly(EGDMA‐VTAZ) have been determined and correlated with common isotherm equations such as Langmuir and Freundlich isotherm models. The Langmuir isotherm model appeared to fit the isotherm data better than the Freundlich isotherm model. The pseudo first‐order kinetic model was used to describe the kinetic data. The study of temperature effect was quantified by calculating various thermodynamic parameters such as Gibbs free energy, enthalpy, and entropy changes. The dimensionless separation factor (RL) showed that the adsorption of metal ions onto poly(EGDMA‐VTAZ) was favorable. It was seen that values of distribution coefficient (KD) decreasing with Cr(VI) concentration in solution at equilibrium (Ce) indicated that the occupation of activate surface sites of adsorbent increased with Cr(VI). © 2009 Wiley Periodicals, Inc. J Appl Polym Sci, 2009  相似文献   

7.
We have prepared a novel kind of magnetic nanoparticle with high adsorption capacity and good selectivity for Pb2+ ions by modifying the magnetic nanoparticles with polyvinyl alcohol (PVA) and thiourea. The resultant magnetic nanoparticles were used to adsorb Pb2+ ions from aqueous solution. The influence of the solution pH, the adsorption time, the adsorption temperature, coexisting ions, and the initial concentration of Pb2+ ions on the adsorption of Pb2+ ions were investigated. The results indicated that Pb2+ ions adsorption was an endothermic reaction, and adsorption equilibrium was achieved within 30 min. The optimal pH for the adsorption of Pb2+ ions was pH 5.5, and the maximum adsorption capacity of Pb2+ ions was found to be 220 mg/g. Moreover, the coexisting cations such as Ca2+, Co2+, and Ni2+ had little effect on adsorption of Pb2+ ions. The regeneration studies showed that thiourea functionalized PVA‐coated magnetic nanoparticles could be reused for the adsorption of Pb2+ ions from aqueous solutions over five cycles without remarkable change in the adsorption capacity. © 2014 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2014 , 131, 40777.  相似文献   

8.
Monolithic PolyHIPE Polymer (PHP), being a highly porous, low density, open cellular material was produced by polymerization of a high internal phase emulsion (HIPE) in which the polymerizable continuous phase consisted of monomers, styrene (STY), and divinyl benzene (DVB). The inner dispersed phase (90 vol %) was an aqueous solution containing 0.4 wt % potassium persulphate as initiator. The resulting porous structure had 12% crosslinking density. Surface chemistry of the monoliths was modified by chloromethylation and amination to impart anionic functionality. Surface modified monoliths had ion exchange capacity of 3.01 meq/g, and had the ability to uptake water about 10 times of its mass. It was used Cr (VI) ion removal from aqueous solution. The experimental results investigated for both the Langmuir and the Dubinin–Radushkevich adsorption models. The maximum Cr (VI) adsorptions are 126.6 mg Cr (VI)/g and 129.3 mg Cr (VI)/g, respectively. The mean free energy E of adsorption is 11.18 kJ/mol according to the Dubinin–Radushkevich adsorption model, indicating that the adsorption occurs through a chemical ion‐exchange process and it is not diffusion limited. © 2015 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2015 , 132, 42286.  相似文献   

9.
A novel magnetic adsorbent, poly(catechol‐1,4‐butanediamine)‐coated Fe3O4 composite (Fe3O4@PCBA), was successfully fabricated via an easy and gentle method according to the mussel‐inspired adhesion property of polydopamine. Effects of many factors on the adsorption performance of Fe3O4@PCBA for Cr(VI) were investigated, including temperature, pH value, contacting time, adsorbent dosage, and initial Cr(VI) concentration. The thermodynamics, adsorption isotherm, kinetics, and intraparticle diffusion of adsorption were also studied systematically. Results indicated that the removal rate of Cr(VI) was approximately close to 100% when the initial concentration was less than 120 mg/L, and the maximum uptake capacity of Fe3O4@PCBA for Cr(VI) was 280.11 mg/g complied with Langmuir isotherm model. Accordingly, the nocuous Cr(VI) could be partially reduced to Cr(III) during the adsorption period. Hopefully, this strategy could be extended to prepare series of magnetic Fe3O4@catechol–amine adsorbents with different amino and phenolic hydroxyl groups for Cr(VI) removal. © 2018 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2018 , 135, 46530.  相似文献   

10.
Activated carbon/chitosan composite has been used as an adsorbent to remove aniline and Cr(VI) ions from aqueous solutions simultaneously. The effects of preparation conditions such as the ratio of activated carbon to chitosan, crosslinking reagents, crosslinking time, and adsorption conditions including adsorbent dosage, pH value of solution, and contact time on simultaneous adsorption of aniline and Cr(VI) ion were investigated. Experimental results showed that epichlorohydrin was the proper crosslinking reagent, and the ratio of activated carbon to chitosan was kept at 1. When the adsorbent dosage was 4.0 g/L, and the concentrations of aniline and Cr(VI) were lower than 50 and 100 mg/L, respectively, both aniline and Cr(VI) were simultaneously removed at natural pH with high removals (>95%). The presence of Cr(VI) enhanced the adsorption of aniline, while the presence of aniline almost had no influence on the adsorption of Cr(VI). The adsorption processes of both aniline and Cr(VI) followed the pseudo‐second‐order kinetics model, but the sorption of Cr(VI) was preferential to that of aniline by this composite. © 2013 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2014 , 131, 39903.  相似文献   

11.
BACKGROUND: A plate‐gap model interpretation of enzymatic reaction kinetics and rotating disc voltammetry were applied for evaluation of the nature of the reaction of the electroreduction of Cr(VI) (as dichromate ions) on a polyaniline (PANI)‐modified glassy carbon (GC) electrode. RESULTS: The kinetic parameters (the maximal current (Vmax) and Michaelis constant (KM)) for electroreduction of Cr(VI) on the PANI‐modified GC electrode were determined as Vmax = 0.34 × 10?7 mol cm?3 s?1 and KM = 0.47 × 10?6 mol cm?3. The reduction of dichromate is intensified by PANI film growth. CONCLUSION: To characterise the electroreduction of Cr(VI) on a PANI‐modified GC electrode, the kinetic parameters of the reaction were determined using a plate–gap model interpretation of enzymatic reaction kinetics and rotating disc voltammetry. The catalytic nature of Cr(VI) electroreduction on the PANI‐modified electrode has been shown. Copyright © 2009 Society of Chemical Industry  相似文献   

12.
This work introduces a biochar as novel adsorbent prepared from the dew melon peel by pyrolysis method, and demonstrates its potential for eliminating Cr(VI) from simulated and actual wastewaters. The dew melon peel biochar (DPB) was characterized by several techniques and methodologies such as, BET, SEM, FTIR, Boehm titration, ultimate analysis, and pHzpc. DPB is a microporous material with the BET specific surface area of 196 m2/g. The effects of different parameters including pH, amount of adsorbent, Cr(VI) concentration, and mixing time on the removal of Cr(VI) from wastewater were studied. Maximum adsorption (98.6%) was observed at pH 6 and 100 mg/L metal concentration. The equilibrium adsorption was analyzed by Langmuir, Freundlich, Temkin, and Dubinin-Radushkevich isotherms. Kinetic data were evaluated by pseudo-first order, pseudo-second order, intraparticle diffusion, film diffusion (Boyd), Elovich, and Avrami models. The kinetic data were best fitted to the pseudo-second order model. The Langmuir isotherm model gives the better correlation to predict the adsorption equilibrium, with a maximum adsorption capacity of 198.7 mg/g. The thermodynamic parameters showed that the adsorption of Cr(VI) was endothermic and spontaneous. Competition between the co-existing ions of Cl?, NO 3 ? , SO 4 2? , PO 4 3? , and HCO 3 ? on the adsorption process was studied. The efficacy of DPB was successfully examined by analyzing the removal of Cr(VI) from two industrial wastewaters. The results indicate that DPB is promising as an effective and economical adsorbent for Cr(VI) ions removal and could be repeatedly used with no significant loss of adsorption efficiency.  相似文献   

13.
Polyaniline/filter‐paper (PANI/FP) composite was prepared by in situ polymerization of polyaniline onto FP and subsequently evaluated for the removal of Cr (VI) from aqueous solution. Scanning electron microscopy and Fourier‐transform infrared were used to investigate the morphology and physicochemical property of PANI/FP composite. Batch experimental results showed that pH value and temperature could affect the removal capability of PANI/FP composite. Langmuir and Freundlich models were used to analysis the equilibrium adsorption, and both of the two models showed the similar correlation coefficients (about R2 = 0.9383). Although the removal capability was still limited, the PANI/FP composite showed the great potential that can be used as an effective adsorbent for removing Cr (VI) from industrial waste‐water. POLYM. COMPOS., 35:993–998, 2014. © 2013 Society of Plastics Engineers  相似文献   

14.
A copolymer flocculant (CATCS) derived from starch and chitosan was fabricated and used as eco‐friendly adsorbent for removal of Cr(VI) from aqueous solution. The CATCS flocculant was characterized by scanning electron microscope, thermogravimetic analysis, and Fourier transform infrared spectroscopy. The effects of CATCS dosage, initial Cr(VI) concentration, pH, and reaction time on removal of Cr(VI) were discussed. The results showed CATCS removed Cr(VI) effectively and the adsorption isotherm agreed well with the Freundlich isotherm and R–P isotherm models. The enthalpy change (ΔH) of the process was 16.75 kJ/mol suggesting the existence of chemisorption and the reaction was endothermic. Moreover, the negative free energy change (ΔG) indicated the adsorption process was feasible and spontaneous. The positive entropy change (ΔS) showed there was an increase of disorder in the system during the adsorption process. The adsorption kinetics results showed that the adsorption could be described by the pseudo‐second‐order kinetics mechanism. The activation energy (Ea) of the adsorption reaction was 29.16 kJ/mol. POLYM. ENG. SCI., 56:1213–1220, 2016. © 2016 Society of Plastics Engineers  相似文献   

15.
The present research provides information on the Cr(VI) removal potential of NaCl-modified Ceratophyllum demersum, an aquatic plant biomass. The effects of various parameters including pH, biomass dosage, contact time, and initial concentration on Cr(VI) biosorption were investigated. The best conditions for Cr(VI) biosorption in the present study were: pH of 2, biosorbent dose of 8 g/L, and contact time of 60 min. Under these conditions, maximum adsorption capacity of modified C. demersum for Cr(VI) was 10.20 mg/g. The experimental biosorption data were modeled by Langmuir, Freundlich and Dubinin-Radushkevich (D-R) isotherms. The biosorption process followed the Langmuir isotherm model with a high coefficient of determination (R2 > 0.99). The biosorption process followed pseudo-second-order kinetics. Further, the biosorbent was characterized by Fourier transform-infrared (FT-IR) spectroscopy and scanning electron microscopy (SEM). The results showed that biosorption of Cr(VI) on NaCl-modified C. demersum occurred through chemical sorption.  相似文献   

16.
《分离科学与技术》2012,47(15):3297-3312
Abstract

A continuous flow colloidal affinity magnetic separation device is used for the removal of As(V) and Cr(VI) from aqueous solutions. Langmuir isotherms fit the adsorption behavior of the individual ions on Orica MIEX® ion exchange particles. In a mixture of equal weight percent As(V) and Cr(VI), the adsorption of As(V) begins only above a critical cut‐off concentration, implying preferential adsorption of the higher valence ion at the available sites. Cr(VI) is removed selectively from the mixture in the continuous flow device, consistent with the presence of a higher concentration of the higher valence ion in the proximity of a charged (anion‐exchange) surface.  相似文献   

17.
Palladized biomass of Desulfovibrio vulgaris (Bio‐Pd(0)) reduced Cr(VI) to Cr(III) at an initial rate four‐fold higher than chemically‐prepared Pd(0) metal. Optimal Cr(VI) reduction by suspended Bio‐Pd(0) occurred at pH 3, whereas pH did not affect the rate of Cr(VI) reduction by Bio‐Pd(0) immobilized in agar beads. The rate of Cr(VI) reduction was concentration‐dependent below 300 µmol dm?3, and application of enzyme kinetics, considering Bio‐Pd(0) as an ‘artificial enzyme’, gave an apparent Km (Kmapp) of approx. 650 µmol dm?3 and Vmax of 1667 nmol h?1 mg Pd(0) for suspended Bio‐Pd(0). The potential of Bio‐Pd(0) as a method for the treatment of Cr(VI)‐wastes is discussed. Copyright © 2005 Society of Chemical Industry  相似文献   

18.
A new polymeric adsorbent material based on polyethylene (PE) was prepared by photografting of 2‐(dimethylamino)ethyl methacrylate (DMAEMA) as a positively chargeable monomer to a PE film. The effects of the experimental parameters, such as the pH value, temperature, and grafted amount on adsorption of chromium(VI) (Cr(VI)) ions were investigated for the DMAEMA‐grafted PE (PE‐g‐PDAMEMA) films. The maximum adsorption capacity was obtained at the initial pH value of 3.0 for a PE‐g‐PDMAEMA film with 1.8 mmol/g and the maximum adsorption capacity obtained was higher than or compatible to those of many of the other polymeric adsorbents prepared for Cr(VI) ions. The adsorption kinetics obeyed the mechanism of the pseudo‐second order kinetic model and adsorption of Cr(VI) ions on PE‐g‐PDMAEMA films was well expressed by the Langmuir isotherm model. A high Langmuir adsorption constant suggests that the adsorption of Cr(VI) ions occurs between protonated dimethylamino groups and ions mainly through the electrostatic interaction. Cr(VI) ions adsorbed were successfully desorbed from a PE‐g‐PDMAEMA film in solutions of NaCl, NH4Cl, NH4Cl containing NaOH, and NaOH and a PE‐g‐PDMAEMA film was regenerated and repeatedly used for adsorption of Cr(VI) ions without appreciable loss in the adsorption capacity. © 2016 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2016 , 133, 43360.  相似文献   

19.
Chitosan (90% deacetylated) coated magnetic adsorbent prepared by coprecipitation method to remove Cr(VI) from its aqueous solution. The experimental studies depicts that the predominant option for removal of Chromium by adsorption from its aqueous phase using Magnetic‐Chitosan (MC). The subsequent physical, chemical, and magnetic properties of MC were characterized by X‐ray powder diffraction, scanning electron microscopy, Fourier transform infrared spectrometer, vibrating sample magnetometer. The influence of batch process parameters such as contact time, initial concentration, pH, and coexisting anions were investigated. The Box‐Behnken experimental design in response surface methodology was performed to design the experiment optimal operating conditions. The maximum percentage reduction of Cr(VI) is 96.3 that was obtained by magnetic chitosan with the optimal operating conditions of 149.53 mg/L at pH of 5.32 at the contact time of 80 min and at the temperature of 303 K. The average diameter of the magnetic chitosan was calculated from X‐ray diffractometer analysis as 24.5 nm. The equilibrium adsorption isotherm models such as Langmuir and Freundlich and the adsorption kinetics such as pseudo first order, pseudo second order and intra‐particle diffusion kinetic model were analyzed. The experimental data's suited for the best fit with the Langmuir isotherm model and pseudo first order kinetic model. It also revealed that Cr(VI) adsorption on MC is intrinsically exothermic and spontaneous. The magnetic chitosan was also used to investigate for the removal of Cr(VI) from the real water sources such as surface, underground, and tannery wastewater. © 2017 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2018 , 135, 45878.  相似文献   

20.
BACKGROUND: This work fulfils the need to develop an eco‐friendly biosorbent, elucidating the mechanism of biosorption. Removal of Cr(VI) by Rhizopus arrhizus was investigated in batch mode. Enhancement in the performance of the biosorbent was attempted by pre‐treating the biomass with inorganic and organic acids, chelating agent, cross‐linker and an organic solvent followed by autoclaving. The surface characterization of the biomass was carried out by potentiometric titration, surface area analysis, infrared spectroscopy, chemical modification of the biomass and scanning electron microscopy. RESULTS: All the physico‐chemical treatments of the biosorbent improved Cr(VI) uptake compared with the native biomass (21.72 mg g?1). The highest biosorption capacity (31.52 mg g?1) was achieved after pre‐treating the biomass with 0.5 mol L?1 HNO3 followed by autoclaving. Surface characterization of the biomass using pHzpc, potentiometry and Fourier transform infrared (FTIR) analysis revealed the role of amino and carboxyl groups in Cr(VI) removal by electrostatic attraction. Chemical modification of amino and carboxyl groups significantly decreased Cr(VI) uptake capacity confirming their role in biosorption. SEM analysis showed adsorption of Cr(VI) on the biosorbent surface. CONCLUSION: Rhizopus arrhizus biomass proved to be an effective and low cost alternative biosorbent for removal of Cr(VI) from aqueous solutions. Copyright © 2011 Society of Chemical Industry  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号