自然通风直接空冷系统凝汽器单元"Λ"型布局和传统翅片结构使得冷却空气流过翅片管束时发生严重转向,从而显著影响空冷凝汽器的流动传热性能。提出了一种新型翅片管束,其翅片通道与基管椭圆长轴方向呈一定夹角,使翅片通道方向与塔浮升力方向平行。通过CFD数值模拟和实验验证,获得了采用新型倾斜翅片管束的自然通风空冷凝汽器的空气流场和温度场,计算得到了不同环境风速下空冷凝汽器总换热量的变化规律,并与现有翅片管束的空冷凝汽器性能进行了对比。研究结果表明,采用倾斜翅片空冷凝汽器可以显著改善自然通风直接空冷系统热力性能,降低机组背压,提高空冷机组运行的经济性。 相似文献
5.
6.
7.
8.
9.
10.
11.
12.
Because of the low heat transfer coefficient of gases, it is necessary to use extended surfaces on the gas side when exchanging heat with liquids or two-phase fluids. Such finned tube exchangers are a very important basic class of heat exchangers. Although finned tube exchangers have been in existence for 50 yr, there have been numerous developments in the technology. This paper attempts to survey the recent developments related to the air-side aspects of heat exchanger design. Nearly all of the recent developments have been empirical because of the complicated gas-side flow structure. Among the developments discussed are the use of special surface geometries for enhanced heat transfer, row effects, local heat transfer coefficient distribution, and correlations for heat transfer coefficient and pressure drop. Two important design configurations—circular finned tubes and plate fin designs—are considered separately. 相似文献
13.
In recent years the requirement for the reduction of energy consumption has been increasing to solve the problems of global warming and the shortage of petroleum resources. For example, in the power generation field, as thermal power generation occupied 60% of the power generation demand, considerable improvement of the thermal efficiency is required. This paper describes the pressure drop characteristics of finned tube banks used for heat exchangers in thermal power generation that were clarified by testing serrated finned tube banks with different fin heights for improved heat transfer and conventional spiral finned tube banks with different fin heights, and an equation to predict pressure drop which is necessary for the heat exchanger design is proposed. © 2006 Wiley Periodicals, Inc. Heat Trans Asian Res, 35(3): 179–193, 2006; Published online in Wiley InterScience ( www.interscience.wiley.com ). DOI 10.1002/htj.20112 相似文献
14.
对椭圆钎焊翅片管和双金属轧制翅片管换热器的传热及阻力性能进行试验对比研究,试验得到了一系列工况下的传热数据与管外空气流动阻力数据,给出了相应的传热系数、流动阻力曲线。从总传热系数中分离出管外空气侧的对流换热系数,得到了具有一定应用价值的管外换热的计算关联式;拟合得到了管外阻力计算关联式。结果表明:椭圆钎焊翅片管比双金属轧制翅片管的传热系数约高9%,管外换热系数约高17%,且管外空气流动阻力约低11%。 相似文献
15.
《International Journal of Heat and Mass Transfer》2007,50(5-6):1163-1175
In this paper, 3-D numerical simulations were performed for laminar heat transfer and fluid flow characteristics of wavy fin-and-tube heat exchanger by body-fitted coordinates system. The effect of four factors were examined: Reynolds number, fin pitch, wavy angle and tube row number. The Reynolds number based on the tube diameter varied from 500 to 5000, the fin pitch from 0.4 to 5.2 mm, the wavy angle from 0° to 50°, and the tube row range from 1 to 4. The numerical results were compared with experiments and good agreement was obtained. The numerical results show that with the increasing of wavy angles, decreasing of the fin pitch and tube row number, the heat transfer of the finned tube bank are enhanced with some penalty in pressure drop. The effects of the four factors were also analyzed from the view point of field synergy principle which says that the reduction of the intersection angle between velocity and fluid temperature gradient is the basic mechanism for enhance convective heat transfer. It is found that the effects of the four factors on the heat transfer performance of the wavy fin-and-tube exchangers can be well described by the field synergy principle. 相似文献
16.
Wei-Mon Yan Hung-Yi Li Jian-Yuan Lin 《International Journal of Heat and Mass Transfer》2003,46(5):871-877
In this paper, the performance of flat plate finned tube heat exchangers operating under frosting conditions was investigated experimentally. Heat exchangers of single and multiple tube row(s) were tested to show the effects of various parameters on heat transfer performance. The parameters include temperature and relative humidity of air, flow rate of air, refrigerant temperature, fin pitch, and row number. The time variations of heat transfer rate, overall heat transfer coefficient, and pressure drop of heat exchangers presented. 相似文献
17.
The third-generation heat transfer technologies, such as three-dimensional fin and dimple, are still important means of improving energy efficiency and will continue to be challenging issues. This paper presents condensation heat transfer performance of an edge-shaped finned tube fabricated by a ploughing–extruding process. The edge-shaped finned tube integrates more than one heat transfer enhancement technology and can enhance the heat transfer capacity greatly. It is seen that the overall heat transfer coefficient and heat flux increase with inlet velocity of cold water increasing, and decrease with inlet temperature of cold water increasing, whereas the shell-side heat transfer coefficient decreases with inlet velocity of cold water increasing and increases with inlet temperature of cold water increasing. At the same inlet velocity, the shell-side heat transfer coefficient for the edge-shaped finned tube is improved by 5–7 times compared to that of a smooth tube. At the same temperature difference between wall and vapor, the shell-side heat transfer coefficient is also higher than what had been reported in the literature. The shell-side heat transfer coefficient of the edge-shaped finned tube decreases with the increase of fabrication parameter feed at the same inlet velocity or inlet temperature of cold water. 相似文献
18.
19.
《Energy》2001,26(11):963-972
The effect of the number of tube rows on heat, mass and momentum transfer is experimentally investigated for flat-plate, finned-tube heat exchangers which consist of aluminum fins and copper tubes. Four flat-plate finned-tube heat exchangers are identical except for changes in the number of tube rows (1 to 4). Heat-transfer coefficients for wet and dry surface conditions are obtained for both heating and cooling of moist air flowing over finned tubes. The air velocity was varied from 0.9 to 4 m/s. Heat transfer, Colburn and friction factors are determinated for different tube rows numbers while the Reynolds number were being warried. It is found that the values of Colburn and friction factors for wet surfaces are higher than for dry surfaces and for both conditions the Colburn and friction factors decrease with an increase in the tube row numbers. 相似文献
20.
对13个不同翅片间距、翅片高度、横向管间距、纵向管间距的螺旋翅片管束换热器在不同雷诺数条件下的传热和阻力特性进行了试验研究,得出了翅片间距、翅片高度、横向管间距、纵向管间距及雷诺数与换热特性Nu和阻力特性Eu的准则关系式,并对准则关系式进行了分析.结果表明:随着横向管间距和翅片间距的增大,螺旋翅片管的传热得到强化,但随着纵向管间距和翅片高度的增加,螺旋翅片管的传热有所减弱;随着横向管间距、纵向管间距和翅片间距的增大,螺旋翅片管的阻力减少,但随着翅片高度的增加,螺旋翅片管的阻力增加. 相似文献