水源热泵空调系统运行优化 总被引:1,自引:0,他引:1
以采用水源热泵机组的某住宅小区为例,分析其建筑的冷热负荷特性,探讨其变化规律;对水源热泵机组、水泵系统、热源井的运行控制策略提出优化方案,为同类工程的节能运行提供参考。 相似文献
7.
9.
10.
11.
Experimental research and operation optimization of an air-source heat pump water heater 总被引:1,自引:0,他引:1
In order to optimize design and operation strategy of air-source heat pump water heater, an experimental set-up and simulation model were constructed. Also, a methodology of optimizing operation, which takes into account thermostatic and timing control patterns, was presented and applied. Experimental results indicated that the average COP ranged from 2.82 to 5.51 under typical conditions. The recommended outside area ratio of condenser coil to evaporator is 0.14−0.31 when the evaporator outside area is between 6.0 and 6.5 m2 for this set-up. The optimal start-up time was between 12:00 and 14:00 if there was no electricity price difference between day and night, or it was near 22:00. The optimal setting water temperature should be adjusted according to the variation of seasonal ambient temperature. It was suggested that, based on this set-up, setting water temperature should be set higher than 46 °C in summer and 50 °C in other seasons. 相似文献
12.
13.
The objective of this study is to investigate the influence of the cooling performance for a water-to-water ground source heat pump (GSHP) by using the counter flow and parallel flow methods. The GSHP uses R-410A as a refrigerant, and its main components are a scroll compressor, plate heat exchangers as a condenser, an evaporator, a thermostatic expansion valve, a receiver, and an inverter. Based on our modeling results, the heat transfer rate of the counter flow evaporator is higher than that of the parallel flow evaporator for a heat exchanger length greater than 0.42 m. The evaporator length of the GSHP used in this study was set to over 0.5 m. The performance of the water-to-water GSHP was measured by varying the compressor speed and source-side entering water temperature (EWT). The cooling capacity of the GSHP increased with increased compressor RPMs and source side EWT. Also, using the counter flow method, compared to the parallel flow method, improves the COP by approximately 5.9% for an ISO 13256-2 rated condition. 相似文献
14.
Heat-pipe enhanced solar-assisted heat pump water heater 总被引:4,自引:0,他引:4
A heat-pipe enhanced solar-assisted heat pump water heater (HPSAHP) is studied. HPSAHP is a heat pump with dual heat sources that combines the performance of conventional heat pump and solar heat pipe collector. HPSAHP operates in heat-pump mode when solar radiation is low and in heat-pipe mode without electricity consumption when solar radiation is high. HPSAHP can thus achieve high energy efficiency. A prototype was designed and built in the present study. An outdoor test for a HPSAHP in the present study has shown that COP of the hybrid-mode operation can reach 3.32, an increase of 28.7% as compared to the heat-pump mode COP (2.58). 相似文献
15.
分析了CO2跨临界循环的特点,介绍了CO2工质在热泵热水器中的研究与应用发展现状,探讨了其目前所面临的问题。与传统制冷剂相比,CO2在热泵热水器中的应用具有广阔的发展前景。 相似文献
16.
空气能热泵热水器的现状及展望 总被引:16,自引:0,他引:16
近年来空气能热泵热水器因其明显的安全性、节能性,受到了广大消费者的关注,显示出巨大的市场潜力。本文简要介绍国内空气能热泵热水器的发展背景、运行机理及研发现状,并与传统三大热水器作了比较分析,概括说明空气能热泵热水器国内的市场状况,指出该产品目前亟待解决的问题。 相似文献
17.
18.
在建筑工程的可行性研究阶段,空调系统冷热源的年运行能耗预测是静态投资回收期分析、全寿命周期成本分析中的核心组成部分,是冷热源选型的重要依据之一.然而,在实际项目中通常选用IPLV/NPLV、设计工况COP进行年运行能耗估算,计算结果与实际能耗有较大的误差.在已知建筑设计冷、热负荷的前提下,引入平衡温度概念,采用BIN方法预测不同温度下的建筑负荷,通过参数修正的方式预测江水源热泵机组在部分负荷率情况下功率,将热泵机组功率修正系数的变化函数拟合为水源侧进水温度和负荷侧回水温度的多项式.对长江上游地区江水温度及气象参数进行监测,并建立了江水温度与空气于球温度的数学关系.提出江水源热泵机组年运行能耗预测方法.该方法反映了系统运行的实际特征,且计算过程较为简单,可以在实际工程中应用. 相似文献