首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Procedures for the reduced-scale analysis of proteins by peptide mapping have been developed, allowing peptide maps to be obtained from picomole to femtomole quantities of protein. The use of trypsin immobilized on agarose gel and placed in a small reactor column has made it possible to reproducibility digest as little as 50 ng of protein. This represents a decrease in sample size of approximately 3 orders of magnitude from conventional tryptic digestion schemes. Separations of tryptic digests were accomplished by using either microcolumn high-performance liquid chromatography (HPLC) or capillary zone electrophoresis (CZE). Separations of 100 ng (4 pmol) of tryptic digest samples of beta-casein were achieved with microcolumn HPLC, while separations of approximately 2 ng (80 fmol) of beta-casein tryptic digest (from a total sample size of 50 ng) were possible with CZE. Peptide maps from phosphorylated and dephosphorylated forms of beta-casein were readily distinguishable using both separation methods, demonstrating an ability to detect a single amino acid modification in a protein. Relative standard deviations of peak retention or migration times were less than 3% for microcolumn HPLC and less than 1% for CZE.  相似文献   

2.
Elution-modified displacement chromatography (EMDC) was employed to achieve peptide separations with high efficiency. On-line ESI-MS and ESI-MS/MS measurements showed enrichment and detection of kemptide, a protein kinase A peptide substrate, at low femtomole levels when it was added as a trace marker component to a tryptic digest of bovine serum proteins or to a human growth hormone peptide digest at concentration ratios between 1:10(5) and 1:10(6). In another EMDC separation, five peptides were detected in a mixture containing 20 fmol of human growth hormone tryptic digest mixed with the bovine serum protein digest. We found that EMDC facilitated rapid detection and sequence analysis of trace peptides at levels of approximately 0.5 fmol/microL in complex peptide mixtures with a wide dynamic concentration range. Accordingly, the detection of kemptide by EMDC was found to be 3-4 orders of magnitude more sensitive than that attained in conventional linear elution chromatography separations performed with the same peptide loads. Kemptide was phosphorylated in vitro and was detected along with its neutral loss product in peptide mixtures at low femtomole levels. EMDC enabled both detection and amino acid sequence determination on trace levels of phosphorylated and other posttranslationally modified peptides, suggesting that the technique may be useful for proteomics applications where detection and analysis of trace level peptides are problematic.  相似文献   

3.
The foundation for saliva-based diagnostics is the development of a complete catalog of secreted proteins detectable in saliva. Besides protein complexity, the greatest bioanalytical challenge facing comprehensive analysis of saliva samples is related to the large variation of protein relative abundances including the presence of high-abundance proteins such as amylases, mucins, proline-rich proteins (PRPs), and secretory IgA complex. Among a number of electrokinetic separation techniques, transient capillary isotachophoresis/capillary zone electrophoresis (CITP/CZE) specifically targets trace amounts of proteins and thus reduces the range of relative protein abundances for providing unparallel advantages toward the identification of low-abundance proteins. By employing a CITP/CZE-based multidimensional separation platform coupled with electrospray ionization-tandem mass spectrometry (ESI-tandem MS), a total of 6112 fully tryptic peptides are sequenced at a 1% false discovery rate (FDR), leading to the identification of 1479 distinct human SwissProt protein entries. By comparing with capillary isoelectric focusing (CIEF) as another electrokinetics-based stacking approach, CITP/CZE not only offers a broad field of application but also is less prone to protein/peptide precipitation during the analysis. The ultrahigh resolving power of CITP/CZE is evidenced by the large number of distinct peptide identifications measured from each CITP fraction together with the low peptide fraction overlapping among identified peptides. Furthermore, when evaluating the protein sequence coverage by the number of distinct peptides mapping to each protein identification, the CITP-based proteome technology similarly achieves the superior performance with 674 proteins (46%) having three or more distinct peptides, 288 (19%) having two distinct peptides, and 517 (35%) having a single distinct peptide.  相似文献   

4.
Electrospray ionization (ESI) tandem mass spectrometry (MS/MS) of peptides in conjunction with automated sequence database searching of the resulting collision-induced dissociation (CID) spectra has become a powerful method for the identification of purified proteins or the components of protein mixtures. The success of the method is critically dependent on the manner by which the peptides are introduced into the mass spectrometer. In this report, we describe a capillary electrophoresis-based system for the automated, sensitive analysis of complex peptide mixtures. The system consists of an ESI-MS/MS instrument, a solid-phase extraction (SPE)-capillary zone electrophoresis (CZE) device for peptide concentration and separation, and an algorithm written in Instrument Control Language (ICL) which modulates the electrophoretic conditions in a data-dependent manner to optimize available time for the generation of high-quality CID spectra of peptides in complex samples. We demonstrate that the data-dependent modulation of the electric field significantly expands the analytical window for each peptide analyzed and that the sensitivity of the SPE-CZE technique is not noticeably altered by the procedure. By applying the technique to the analysis of in vivo phosphorylation sites of endothelial nitric oxide synthase (eNOS), we demonstrate the power of this system for the MS/MS analysis of minor peptide species in complex samples such as phosphopeptides generated by the proteolytic digestion of a large protein, eNOS, phosphorylated at low stoichiometry.  相似文献   

5.
R Wu  H Zou  M Ye  Z Lei  J Ni 《Analytical chemistry》2001,73(20):4918-4923
A mode of capillary electrochromatography for separation of ionic compounds driven by electrophoretic mobility on a neutrally hydrophobic monolithic column was developed. The monolithic column was prepared from the in situ copolymerization of lauryl methacrylate and ethylene dimethacrylate to form a C12 hydrophobic stationary phase. It was found that EOF in this hydrophobic monolithic column was very poor, even the pH value of mobile phase at 8.0. The peptides at acidic buffer were separated on the basis of their differences in electrophoretic mobility and hydrophobic interaction with the stationary phase; therefore, different separation selectivity can be obtained in CEC from that in capillary zone electrophoresis (CZE). Separation of peptides has been realized with high column efficiency (up to 150,000 plates/meter) and good reproducibility (migration time with RSD <0.5%), and all of the peptides, including some basic peptides, showed good peak symmetry. Effects of the mobile phase compositions on the retention of peptides at low pH have been investigated in a hydrophobic capillary monolithic column. The significant difference in selectivity of peptides in CZE and CEC has been observed. Some peptide isomers that cannot be separated by CZE have been successfully separated on the capillary monolithic column in this mode with the same buffer used.  相似文献   

6.
Direct mass spectrometric quantification of peptides and proteins is compromised by the wide variabilities in ionization efficiency which are hallmarks of both the MALDI and ESI ionization techniques. We describe here the implementation of a fluorescence detection system for measurement of the UV-excited intrinsic fluorescence (UV-IF) from peptides and proteins just prior to their exit and electrospray ionization from an ESI capillary. The fluorescence signal provides a quantifiable measure of the amount of protein or peptide present, while direct or tandem mass spectrometric analysis (MS/MS) on the ESI-generated ions provides information on identity. We fabricated an inexpensive, modular fluorescence excitation and detection device utilizing an ultraviolet light-emitting diode for excitation in a ~300 nL fluorescence detection cell integrated into the fused-silica separation column. The fluorescence signal is linear over 3 orders of magnitude with on-column limits of detection in the low femtomole range. Chromatographically separated intact proteins analyzed using UV-IF prior to top-down mass spectrometry demonstrated sensitive detection of proteins as large as 77 kDa.  相似文献   

7.
Feng YL  Zhu J 《Analytical chemistry》2006,78(18):6608-6613
A new on-line capillary zone electrophoresis/mass spectrometry (CZE/MS), constant pressure-assisted electrokinetic injection (PAEKI), for the analysis of negatively charged nucleotides is reported. PAEKI uses an applied pressure to counterbalance the reverse electroosmotic flow in the capillary column during sample injection, while taking advantage of the field amplification in the sample medium. At balance, the running buffer in the column is stationary, permitting potentially unlimited injection time, and hence unlimited sample enrichment power. The ability of PAEKI to maintain a narrow sample zone over a long injection time seems to be a result of the formation of a high ion concentration band at the boundary of the two media due to rapid deceleration of the migrating ions at the boundary. The injected amount of analytes proved to be linearly proportional to both the field amplification factor, which is expressed as the ratio of resistivities of sample medium to running buffer, and the injection time, which extended up to 1200 s in CZE/MS and 3600 s in CZE/UV. For a 300-s on-line PAEKI injection in CZE/MS, 3 orders of magnitude sample enhancement (5000-fold enrichment) could be observed for the four single nucleotides without compromising separation efficiency and peak shape, and an achievement of detection limits between 0.04 and 0.07 ng/mL. With appropriate sample cleanup, PAEKI can be used in the analysis of single nucleotides in enzyme-digested DNA.  相似文献   

8.
We describe approaches for proteomics analysis using electrospray ionization-tandem mass spectrometry coupled with fast reversed-phase liquid chromatography (RPLC) separations. The RPLC separations used 50-microm-i.d. fused-silica capillaries packed with submicrometer-sized C18-bonded porous silica particles and achieved peak capacities of 130-420 for analytes from proteome tryptic digests. When these separations were combined with linear ion trap tandem mass spectrometry measurements, approximately 1000 proteins could be identified in 50 min from approximately 4000 identified tryptic peptides; approximately 550 proteins in 20 min from approximately 1800 peptides; and approximately 250 proteins in 8 min from approximately 700 peptides for a S. oneidensis tryptic digest. The dynamic range for protein identification with the fast separations was determined to be approximately 3-4 orders of magnitude of relative protein abundance on the basis of known proteins in human blood plasma analyses. We found that 55% of the MS/MS spectra acquired during the entire analysis (and up to 100% of the MS/MS spectra acquired from the most data-rich zone) provided sufficient quality for identifying peptides. The results confirm that such analyses using very fast (minutes) RPLC separations based on columns packed with microsized porous particles are primarily limited by the MS/MS analysis speed.  相似文献   

9.
A matrix-assisted laser desorption/ionization (MALDI) ion trap mass spectrometer of new design is described. The instrument is based on a commercial Finnegan LCQ ion trap mass spectrometer to which we have added a MALDI ion source that incorporates a sample stage constructed from a compact disk and a new ion transmission interface. The ion interface contains a quadrupole ion guide installed between the skimmer and the octapoles of the original instrument configuration, allowing for operation in both MALDI and electrospray ionization modes. The instrument has femtomole sensitivity for peptides and is capable of collecting a large number of MALDI MS and MALDI MS/MS spectra within a short period of time. The MALDI source produces reproducible signals for 10(4)-10(5) laser pulses, enabling us to collect MS/MS spectra from all the discernible singly charged ions detected in a MS peptide map. We describe the different modes of the instrument operation and algorithms for data processing as applied to challenging protein identification problems.  相似文献   

10.
We demonstrate the use of capillary zone electrophoresis with an electrokinetically pumped sheath-flow electrospray interface for the analysis of a tryptic digest of a sample of intermediate protein complexity, the secreted protein fraction of Mycobacterium marinum. For electrophoretic analysis, 11 fractions were generated from the sample using reverse-phase liquid chromatography; each fraction was analyzed by CZE-ESI-MS/MS, and 334 peptides corresponding to 140 proteins were identified in 165 min of mass spectrometer time at 95% confidence (FDR < 0.15%). In comparison, 388 peptides corresponding to 134 proteins were identified in 180 min of mass spectrometer time by triplicate UPLC-ESI-MS/MS analyses, each using 250 ng of the unfractionated peptide mixture, at 95% confidence (FDR < 0.15%). Overall, 62% of peptides identified in CZE-ESI-MS/MS and 67% in UPLC-ESI-MS/MS were unique. CZE-ESI-MS/MS favored basic and hydrophilic peptides with low molecular masses. Combining the two data sets increased the number of unique peptides by 53%. Our approach identified more than twice as many proteins as the previous record for capillary electrophoresis proteome analysis. CE-ESI-MS/MS is a useful tool for the analysis of proteome samples of intermediate complexity.  相似文献   

11.
Large peptides with similar electrophoretic mobilities were separated by micellar electrokinetic chromatography (MEKC) with organic modifiers. [Leu13]motilin and [Met13]motilin differ by only one neutral amino acid residue. Because the electrophoretic mobilities of these peptides are almost identical, these peptides were not separated by capillary zone electrophoresis (CZE). Such large peptides have not been separated by conventional MEKC either, because they interacted strongly with the micelle. However, they were completely separated by MEKC when an organic solvent was added to the micellar solution. Some insulins, larger peptides than motilin, from different origins, which have very similar electrophoretic mobilities, were also successfully separated by the same technique. The size of peptides which were separated without organic modifiers was examined.  相似文献   

12.
This work focuses on the development of a multidimensional electrokinetic-based separation/concentration platform coupled with electrospray ionization-Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICR-MS) for achieving the high resolution and ultrasensitive analysis of complex protein/peptide mixtures. A microdialysis junction is employed as the interface for on-line combination of capillary isoelectric focusing (CIEF) with transient capillary isotachophoresis/zone electrophoresis (CITP/CZE) in an integrated platform. Besides the excellent resolving power afforded by both CIEF and CZE separations, the electrokinetic focusing/stacking effects of CIEF and CITP greatly enhance the dynamic range and detection sensitivity of MS for protein identification. The constructed multidimensional separation/concentration platform is demonstrated for the analysis of Shewanella oneidensis proteome, which has considerable implications toward the bioremediation of environmental pollutants. The electrokinetic-based platform offers the overall peak capacity comparable to those obtained using multidimensional chromatography systems, but with a much shorter run time and no need for column regeneration. Most importantly, a total of 1174 unique proteins, corresponding to 26.5% proteome coverage, are identified from the cytosolic fraction of S. oneidensis, while requiring <500 ng of proteolytic digest loaded in the CIEF capillary. The ultrasensitive capabilities of electrokinetic-based proteome approach are attributed to the concentration effect in CIEF, the electrokinetic stacking of CITP, the nanoscale peak volume in CZE, the "accurate mass tag" strategy for protein/peptide identification, and the high-sensitivity, high-resolution, and high-mass measurement accuracy of FTICR-MS.  相似文献   

13.
Primary protein sequences were determined for both peptides and enzymatically digested proteins by rapid linked-scan (B/E) liquid chromatography/mass spectrometry/mass spectrometry (LC/MS/MS) at the low-picomole level (10-50 pmol). During the course of a single LC/MS/MS analysis, we demonstrated that it is possible to generate interpretable collision-induced dissociation spectra of the eluting proteolytic peptides. Molecular weights of tryptic peptides were established by using 1/10 of the protein digest by operating in the capillary LC/frit-FABMS mode. Peptides exhibiting the strongest MH+ ions were then selected for subsequent LC/MS/MS analysis (typically 1/5 of the remaining protein digest). Elution times for each chromatographic peak were generally greater than 30 s. It was therefore possible to obtain a minimum of six B/E fast linked-scan spectra during the course of elution of each peptide component. Typically, B/E linked scans of the greatest ion abundance (obtained at the chromatographic peak maximum) were averaged to enhance the signal/noise ratio at these low-picomole levels. Unit resolution was observed for product ions below m/z 1000. Rapid linked scanning by LC/frit-FABMS/MS provided mass assignments for product ions within 0.2-0.3 amu of theoretical values. Side-chain fragment ions (wn and dn) were also observed, which allowed for the differentiation of isobaric amino acids (e.g., leucine and isoleucine). Examples of the application of this fast linked-scan technique to LC/MS/MS are presented for complex mixtures of unknown peptides and the tryptic digestion of phosphorylated beta-casein.  相似文献   

14.
Tandem mass spectrometry (MS/MS) plays an important role in the unambiguous identification and structural elucidation of biomolecules. In contrast to conventional MS/MS approaches for protein identification where an individual polypeptide is sequentially selected and dissociated, a multiplexed-MS/MS approach increases throughput by selecting several peptides for simultaneous dissociation using either infrared multiphoton dissociation (IRMPD) or multiple frequency sustained off-resonance irradiation (SORI) collisionally induced dissociation (CID). The high mass measurement accuracy and resolution of FTICR combined with knowledge of peptide dissociation pathways allows the fragments arising from several different parent ions to be assigned. Herein we report the application of multiplexed-MS/MS coupled with on-line separations for the identification of peptides present in complex mixtures (i.e., whole cell lysate digests). Software was developed to enable "on-the-fly" data-dependent peak selection of a subset of polypeptides from each FTICR MS acquisition. In the subsequent MS/MS acquisitions, several coeluting peptides were fragmented simultaneously using either IRMPD or SORI-CID techniques. The utility of this approach has been demonstrated using a bovine serum albumin tryptic digest separated by capillary LC where multiple peptides were readily identified in single MS/MS acquisitions. We also present initial results from multiplexed-MS/MS analysis of a D. radiodurans whole cell digest to illustrate the utility of this approach for high-throughput analysis of a bacterial proteome.  相似文献   

15.
A superior approach involving nano-high-performance liquid chromatography (nano-HPLC) in on-line conjunction to electrospray ionization quadrupole time-of-flight mass spectrometry (ESI QTOF MS) and tandem MS for screening and structural characterization of complex mixtures of neutral glycosphingolipids (GSLs) is here described. Neutral GSLs purified from human erythrocytes were efficiently separated according to the differences in carbohydrate chain length by an optimized nano-HPLC protocol and flow-through detected by ESI QTOF MS at the low femtomole level. Additionally, GSL species were accurately distinguished from the accompanying lipids in the mixture, thus permitting the determination of detailed structural characteristics by data-dependent analysis for identification of GSL constitution within single experiments. An alternative nano-HPLC/ESI QTOF MS approach was designed for dissection of unsaturation/saturation degree of the ceramide moieties defining the hydrophobic portion of GSLs and subsequent localization by nano-HPLC/ESI QTOF MS/MS of the -CH=CH- within the ceramide regions. The method is fast, highly sensitive, and high-throughput amenable and is highlighted as a new and valuable analytical dimension in glycolipidomics.  相似文献   

16.
Garza S  Moini M 《Analytical chemistry》2006,78(20):7309-7316
Identification of proteins, in a complex protein mixture, using one-dimensional high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) analysis of its digest, usually suffers from low sequence coverage. There are several reasons for the low coverage including undersampling, wide concentration dynamic range of the proteins in a complex protein mixture, and wide range of electrospray ionization efficiency of peptides under each mobile-phase composition. To address this low sequence coverage, we introduce a novel technique, (CE-MS/MS)n, which utilizes the most significant advantages of CE-MS/MS, including economy of sample size, fast analysis time, and high separation efficiency, to increase the sequence coverage of a complex protein mixture. Based on these characteristics, (CE-MS/MS)n can be performed in which multiple CE-MS/MS subanalyses (injections followed by analyses) are analyzed and experimental variables are manipulated during each CE-MS/MS subanalysis in order to maximize sequence coverage. (CE-MS/MS)n is a practical technique since each CE-MS/MS subanalysis consumes <10 nL, and each CE-MS/MS subanalysis takes approximately 10 min; therefore, several subanalyses can be performed in approximately 1 h consuming only nanoliters of the sample. Two techniques have been introduced to address the undersampling: (1) (CE-MS/MS)n using dynamic exclusion. In this technique, several CE-MS/MS analyses (injection followed by separation) were performed in one run using the dynamic exclusion capability of the mass spectrometer until all peptide peaks were analyzed by MS/MS. (2) Gas-phase fractionation. In this technique, (CE-MS/MS)n is performed by scanning a narrow mass range (every approximately 100 m/z) during each CE-MS/MS subanalysis without using dynamic exclusion. Under this condition, in each subanalysis, the number of peptides available for MS/MS analysis is significantly reduced, and peptides with the same nominal masses are analyzed, thereby increasing sequence coverage. Additionally, to address the lack of detection of low-level peptides in a mixture containing a wide concentration dynamic range, the concentration of the sample was systematically increased in each subanalysis (while utilizing dynamic exclusion) so that low-intensity peptides would rise above the mass spectrometer threshold and, consequently, undergo MS/MS analysis. Moreover, to alter the ionization efficiency of peptides with low electrospray ionization efficiency, and to change the migration behavior of comigrating peptides under a specific liquid composition, the CE background electrolyte was modified in several subanalyses to further improve sequence coverage. The combination of the above-mentioned techniques was applied to the analysis of the tryptic digests of three well-characterized protein mixtures: a six-protein mixture with average MW of approximately 26,000 (standard I), a six-protein mixture with an average MW approximately 49,000 (standard II), and a more complex protein mixture containing 55 proteins (E. coli ribosomal proteins). In approximately 1 h, when the MS/MS of the peptides were manually checked, all peptides that produced peaks under electrospray ionization in the scanned range of the analysis (500-2000 m/z) and within the practical fragmentation capability of the MS (peptides with MW <3500) were identified for standard I by consuming only 200 fmol of each protein. When searched against a Swissprot database, the average sequence coverage for the standard I, II, and E. coli's ribosomal proteins were 57, 34, and 15%, respectively.  相似文献   

17.
A novel liquid-liquid extraction (LLE) procedure was investigated for preparation of peptide and protein samples for matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS). LLE using ethyl acetate as the water-immiscible organic solvent enabled segregation of hydrophobic and hydrophilic polypeptides in mixtures, thereby reducing the complexity of mass spectra obtained by MALDI MS. The LLE technique was optimized for rapid and sensitive in situ (on-target) sample preparation for MALDI MS analysis of proteins and peptides at low-picomole and subpicomole levels. Addition of MALDI matrix to the organic solvent enhanced the efficiency of the LLE-MALDI MS method for analysis of hydrophobic peptides and proteins. LLE-MALDI MS enabled the detection of the hydrophobic membrane protein bacteriorhodopsin as a component in a simple protein mixture. Peptide mixtures containing phosphorylated, glycosylated, or acylated peptides were successfully separated and analyzed by the in situ LLE-MALDI MS technique and demonstrate the potential of this method for enhanced separation and structural analysis of posttranslationally modified peptides in proteomics research.  相似文献   

18.
We present an MS/MS database search algorithm with the following novel features: (1) a novel protein database structure containing extensive preindexing and (2) zone modification searching, which enables the rapid discovery of protein modifications of known (i.e., user-specified) and unanticipated delta masses. All of these features are implemented in Interrogator, the search engine that runs behind the Pro ID, Pro ICAT, and Pro QUANT software products. Speed benchmarks demonstrate that our modification-tolerant database search algorithm is 100-fold faster than traditional database search algorithms when used for comprehensive searches for a broad variety of modification species. The ability to rapidly search for a large variety of known as well as unanticipated modifications allows a significantly greater percentage of MS/MS scans to be identified. We demonstrate this with an example in which, out of a total of 473 identified MS/MS scans, 315 of these scans correspond to unmodified peptides, while 158 scans correspond to a wide variety of modified peptides. In addition, we provide specific examples where the ability to search for unanticipated modifications allows the scientist to discover: unexpected modifications that have biological significance; amino acid mutations; salt-adducted peptides in a sample that has nominally been desalted; peptides arising from nontryptic cleavage in a sample that has nominally been digested using trypsin; other unintended consequences of sample handling procedures.  相似文献   

19.
Ji L  Wu JH  Luo Q  Li X  Zheng W  Zhai G  Wang F  Lü S  Feng YQ  Liu J  Xiong S 《Analytical chemistry》2012,84(5):2284-2291
We describe herein the development of a matrix-assisted laser desorption/ionization-time-of-flight-mass spectrometry (MALDI-TOF-MS) approach for screening of protein kinase inhibitors (PKIs). MS quantification of phosphopeptides, the kinase-catalyzed products of nonphosphorylated substrates, is a great challenge due to the ion suppression effect of highly abundant nonphosphorylated peptides in enzymatic reaction mixtures. To address this issue, a novel type of titania coated magnetic hollow mesoporous silica spheres (TiO(2)/MHMSS) material was fabricated for capturing phosphopeptides from the enzymatic reaction mixtures prior to MS analysis. Under optimized conditions, even in the presence of 1000-fold of a substrate peptide of tyrosine kinase epidermal growth factor receptor (EGFR), the phosphorylated substrates at the femtomole level can be detected with high accuracy and reproducibility. With a synthetic nonisotopic labeled phosphopeptide, of which the sequence is similar to that of the phosphorylated substrate, as the internal standard, the MS signal ratio of the phosphorylated substrate to the standard is linearly correlated with the molar ratio of the two phosphopeptides in peptide mixtures over the range of 0.1 to 4 with r(2) being 0.99. The IC(50) values of three EGFR inhibitors synthesized in our laboratory were then determined, and the results are consistent with those determined by an enzyme-linked immunosorbent assay (ELISA). The developed method is sensitive, cost/time-effective, and operationally simple and does not require isotope/radioative-labeling, providing an ideal alterative for screening of PKIs as therapeutic agents.  相似文献   

20.
The formation of multiply charged molecular ions via the field-assisted ion evaporation mechanism during electrospray ionization enables the use of an atmospheric pressure ionization quadrupole mass spectrometer system for characterizing biologically important peptides. The straightforward implementation of high-performance liquid chromatography (HPLC) into this new strategy to determine the molecular weight of tryptic peptides via the pneumatically assisted electrospray (ion spray) interface is presented. Examples utilizing both microbore (1.0 mm) and standard bore (4.6 mm) inside diameter columns are shown for the LC/MS molecular weight determination of tryptic peptides in methionyl-human growth hormone (met-hGH). Injected levels from 50 to 75 pmol of tryptic digest onto 1 mm i.d. HPLC columns provided full-scan LC/MS or LC/MS/MS results without postcolumn splitting of the effluent. When standard 4.6 mm i.d. HPLC columns were used, a 20:1 postcolumn split was utilized, which required from 1 to 5 nmol of injected tryptic digest for full-scan LC/MS or LC/MS/MS results. Collision-induced dissociation (CID) mass spectra resulting from either "infusion" or on-line LC/MS/MS analysis of the abundant doubly charged ions that predominate for tryptic peptides under electrospray conditions provided structurally useful sequence information for met-hGH and human hemoglobin tryptic digests. The slower mass spectrometer scan rate used during infusion of sample provides more accurate mass assignments than on-line LC/MS or LC/MS/MS, but the latter on-line experiments preclude ambiguities caused by matrix or component interferences. However, in some instances very weak CID product ions preclude complete tryptic peptide structural characterization based upon the CID data alone.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号