1.
一种新颖有源箝位ZVS正激变换器的研究   总被引:2,自引:0,他引:2  
介绍了一种中心抽头全波整流有源箝位ZVS正激变换器的工作原理及主要参数计算。有源箝位电路由一个箝位开关管和箝位电容组成。变压器磁芯实现无损复位,励磁能量和漏感能量全部传递到负栽.磁芯利用率高,功率开关管承受电压应力降低。通过变压器漏感与开关管输出电容的谐振,主开关管与箝位开关管都可以实现ZVS开通,提高了变换器工作效率。文章首先分析了变换器工作原理,然后给出了主要参数的计算方法,最后通过样机(48V输入5V/20A输出)实验验证了该拓扑的高效性能。  相似文献   

2.
An active clamp SEPIC converter with synchronous rectifier is presented to achieve zero voltage switching (ZVS). The active clamp circuit is adopted in the proposed converter to absorb the energy stored in the leakage inductance of the transformer and limit the peak voltage stress on the switching devices. The resonance during the transition interval between the switching devices will help the power switches to turn on at ZVS. Therefore, the switching losses of switches are effectively reduced. The synchronous rectifier is used at the secondary side of the transformer to further reduce the conduction loss. The principle of operation and the steady-state analysis of the proposed converter are presented. Finally, the experimental results taken from a laboratory prototype with 240 W (12V/20A) rated power are presented to verify the effectiveness of the proposed converter.  相似文献   

3.
给出了一种零电压开关Zeta变换器,这种变换器可以提高效率和减小功率开关管的电压应力.当变换器工作在连续模式时,应用谐振电容和变压器的漏感实现功率开关管的零电压导通.详细分析了变换器的工作原理,并设计了相应的电路进行验证.仿真结果表明所设计的Zeta变换器效率达92.21%,输出电压纹波为125 mV.它可被用于等离子显示屏(PDP)电源系统.  相似文献   

4.
This brief presents the analysis, design, and implementation of zero-voltage switching (ZVS) active clamp converter with series-connected transformer. A family of isolated ZVS active clamp converters is introduced. The technique of the adopted ZVS commutation will not increase additional voltage stress of switching devices. In the adopted converter with series-connected transformer, each transformer can be operated as an inductor or a transformer. Therefore, no output inductor is needed. To reduce the voltage stress of the switching device in the conventional forward converter, the active clamp technique is used to recycle the energy stored in the transformer leakage back into the input dc source. Finally, experimental results are presented taken from a laboratory prototype with 100-W rated power, input voltage of 155 V, output voltage of 5 V, and operating at 150 kHz. [All rights reserved Elsevier].  相似文献   

5.
This article presents the circuit implementation and design considerations of a zero voltage switching (ZVS) converter with voltage step-up for battery-based applications. An active-clamp circuit including one auxiliary switch and one clamp capacitor is connected in parallel with the main switch to allow resonant behaviour by the output capacitances of switches and transformer leakage inductance during the transition interval. Thus, the ZVS turn-on of switches can be achieved. The switching losses and thermal stresses of the semiconductors are reduced. The circuit configuration, operation principle and design considerations of the converter are discussed in detail. Finally, experiments conducted on a laboratory prototype rated at 200 W are provided to verify the theoretical analysis and the effectiveness of the proposed converter.  相似文献   

6.
In this paper, an interleaved soft-switching converter with ripple-current cancellation is presented to achieve zero- voltage-switching (ZVS) turn-on and load current sharing. In order to achieve ZVS turn-on, an active snubber is connected in parallel with the primary winding of the transformer. The energy stored in the transformer leakage inductance and magnetizing inductance can be recovered so that the peak voltage stress of switching devices is limited. The resonance at the transition interval is used to realize ZVS turn-on of all switches. In order to achieve three-level pulsewidth-modulation (PWM) scheme, an addition fast-recovery diode is used in the converter. Three-level PWM scheme can reduce the ac ripple current on the output inductor such that the output inductor can be reduced. The current-doubler rectifier is adopted in the secondary side of the transformer to reduce the transformer secondary-winding current and output voltage ripple by canceling the current ripple of two output inductors. The output voltage is controlled at the desired value using the interleaved PWM scheme. These features make the proposed converter suitable for the dc-dc converter with high output current. The operation principles, steady state analysis, and design equations of the proposed converter are provided in detail. Finally, experiments based on a 600-W (12 V/50 A) prototype are provided to verify the effectiveness and feasibility of the proposed converter.  相似文献   

7.
A new boost half bridge (BHB) converter is presented. It is composed of additional switch, diode and coupled winding to boost inductor of BHB converter. Using the transferring of boost inductor current to coupled winding in a short period, the cancellation of zero voltage switching (ZVS) current, which always occurs in convention one, is prevented. Therefore, the ZVS operation is easily achieved by leakage inductor current of transformer. Furthermore, since negatively build-up leakage inductor current of boost winding helps the ZVS operation throughout full load range, the excellent ZVS operation and high efficiency is achieved.   相似文献   

8.
In this article, a voltage equaliser is proposed for a battery string with four Li–Fe batteries. The proposed voltage equaliser is developed from a flyback converter, which comprises a transformer, a power electronic switch and a resonant clamped circuit. The transformer contains a primary winding and four secondary windings with the same number of turns connected to each battery. The resonant clamped circuit is for recycling the energy of leakage inductance of the transformer and for performing zero-voltage switching (ZVS) of the power electronic switch. When the power electronic switch is switched on, the energy is stored in the transformer; and when the power electronic switch is switched off, the energy stored in the transformer will automatically charge the battery whose voltage is the lowest. In this way, the voltage of individual batteries in the battery string is balanced. The salient features of the proposed voltage equaliser are that only one switch is used, the energy stored in the leakage inductance of the transformer can be recycled and ZVS is obtained. A prototype is developed and tested to verify the performance of the proposed voltage equaliser. The experimental results show that the proposed voltage equaliser achieves the expected performance.  相似文献   

9.
This paper describes a simple and effective way to modify an existing hard-switched flyback power converter into a circuit with zero-voltage switching (ZVS) and zero-current switching (ZCS). The key improvement is to turn the unattractive features of the coupled inductor leakage inductance and snubber capacitor into attractive ones. The coupled inductor leakage inductance and snubber are used to form a quasi-resonant circuit to facilitate ZVS/ZCS of all power devices. The operating principles of the power converter and experimental results are presented  相似文献   

10.
有源钳位正激变换器可以实现零电压开关(ZVS),降低功率开关损耗;同步整流可以提高低压大电流输出的开关电源的效率。介绍了一种基于有源钳位脉宽调制控制器UCC2892和同步整流控制器LTC3900的正激开关电源设计。  相似文献   

11.
A soft-switching converter is presented in this paper to achieve a zero-voltage-switching (ZVS) turn on for all switches. Two half-bridge converters with asymmetric pulsewidth-modulation scheme are connected in parallel to control the output voltage at the desired value and achieve load-current sharing. Based on the output capacitance of power switches and the resonant inductance, including the external inductance and the transformer leakage inductance, the resonance can be achieved at the transition interval of power switches. Therefore, the ZVS turn on of power switches can be realized. The peak voltage of the power switches is limited to input dc voltage. The center-tapped rectifier is adopted at the transformer secondary side to achieve a full-wave rectification. Operation principles, steady-state analysis, and design equations of the proposed converter are discussed in detail. Finally, experimental results based on a 240-W prototype are provided to verify the performance and the feasibility of the proposed converter.  相似文献   

12.
A simple and effective approach of turning an isolated hard-switched converter design into a soft-switched one is presented. By adding an auxiliary winding, switch and small capacitor to the conventional pulsewidth modulation (PWM) isolated flyback converter, all switches and diodes are softly turned on and off. No extra active or passive voltage clamp circuit is needed to suppress voltage stress on the switching devices that were usually found in classical converters. A zero-current-switching (ZCS) PWM flyback converter topology with multiple outputs is analyzed and examined. The proposal inherently utilizes the leakage inductance of the “flyback” transformer to achieve ZCS of all switching devices. A complete steady-state DC analysis and the operating principle are described. The performance of an 80 W experimental converter prototype with dual-voltage outputs is included  相似文献   

13.
A new active clamping zero-voltage switching (ZVS) pulse-width modulation (PWM) current-fed half-bridge converter (CFHB) is proposed in this paper. Its active clamping snubber (ACS) can not only absorb the voltage surge across the turned-off switch, but also achieve the ZVS of all power switches. Moreover, it can be applied to all current-fed power conversion topologies and its operation as well as structure is very simple. Since auxiliary switches in the snubber circuit are switched in a complementary way to main switches, an additional PWM IC is not necessary. In addition, it does not need any clamp winding and auxiliary circuit besides additional two power switches and one capacitor while the conventional current-fed half bridge converter has to be equipped with two clamp windings, two ZVS circuits, and two snubbers. Therefore, it can ensure the higher operating frequency, smaller-sized reactive components, lower cost of production, easier implementation, and higher efficiency. The operational principle, theoretical analysis, and design considerations are presented. To confirm the operation, validity, and features of the proposed circuit, experimental results from a 200-W, 24-200Vdc prototype are presented.  相似文献   

14.
本电源是基于高频高压交流母线具有多组输出的直流电源,它具有高达200kHz的开关频率,后级的整流电路由于高频交流母线的存在,使得变压器和电感的设计变得简单,滤波电容的选择也更容易。本电源由PFC电路提供400V的高压直流输入,再由MOSFET组成全桥逆变电路,在固定额率的PWM发生电路和IR2110 MOSFET驱动电路作用下,只加—个谐振电感就可实现开关管的零电压开通,可在大大降低开关损耗和噪声的同时实现直流交流的变换。整流部分采用倍流整流电路以提高原边电压的利用率,可输出低压大电流。由于采用肖特基管,—方面可使得二板管的损耗可以接受,另外—方面还避免了采用同步整流电路所面临的电路结构复杂和驱动困难。  相似文献   

15.
A fully soft-switched boost-converter using a one auxiliary switch is presented here. It uses the minimum number of components in the auxiliary circuit with minimum current stress of the main switch. Since the resonant capacitor charges only through an inductor and a diode, the circuit conduction losses are minimized. The main and auxiliary insulated gate bipolar transistor (IGBT) switches share a common emitter connection, facilitating direct drive to them. Various operating modes of the converter are presented in detail and analysed. The choice of the resonating capacitor and inductor has been done through an optimization process based on the guiding equations working under different modes. In this optimization process, emphasis has been given on minimum voltage stress on the auxiliary switch for a wide duty cycle range of operation. Based on the design, the principle of operation has been verified with computer simulation. Experimental results from a laboratory prototype with active power factor correction confirms the operation of this converter.  相似文献   

16.
《Electronics letters》2008,44(17):1029-1030
A novel zero voltage switching (ZVS) isolated converter is presented. The output voltage doubler is used on the output side to achieve the boost type of voltage conversion ratio. Active-clamping technique is adopted to realise the ZVS turn-on of all switches. The proposed circuit has no large output inductor such that the adopted circuit has a simpler structure, lower cost and no effective duty loss. Finally experimental results based on a 300 W prototype are provided to verify the effectiveness of the proposed converter.  相似文献   

17.
Flyback derived power convertor topologies are attractive because of their relative simplicity when compared with other topologies used in low power applications. Incorporation of active-clamp circuitry into the flyback topology serves to recycle transformer leakage energy while minimizing switch voltage stress. The addition of the active-clamp circuit also provides a mechanism for achieving zero-voltage-switching (ZVS) of both the primary and auxiliary switches. ZVS also limits the turn-off di/dt of the output rectifier, reducing rectifier switching losses, and switching noise due to diode reverse recovery. This paper analyzes the behavior of the ZVS active-clamp flyback operating with unidirectional magnetizing current and presents design equations based on this analysis. Experimental results are then given for a 500 W prototype circuit illustrating the soft-switching characteristics and improved efficiency of the power converter. Results from the application of the active-clamp circuit as a low-loss turn-off snubber for IGBT switches is also presented  相似文献   

18.
在常规的硬开关电路中,由于变压器漏感及寄生电容的影响,常常在开关转换瞬间会产生很高的电压尖峰。本文采用有源箝位反激式变换器电路,实现了零电压零电流(ZVZCS)软开关变换,使电压尖峰得到了抑制。该电路成功地应用了UPCI909控制芯片,简化了传统的驱动电路。实验结果表明,主开关管两端电压被箝位在一定数值,实现了零电压零电流开关,效率达到90%。  相似文献   

19.
Forward converter with active clamp is a suitable topology for a low output voltage and high output current dc-dc power supply module. The topology can be used in a resonant transition manner to obtain a low voltage over the main switch at turn-on instant. A low voltage can be obtained by adjusting the magnitude of the magnetizing current of the transformer and the delay between the two primary side switches. An increased magnetizing current, however, increases conduction losses in the primary side of the converter and may consume the advantage gained in the switching losses. The converter can also be easily used for self-driven synchronous rectification. However, pursue for low switching losses for the primary side switch may deteriorate performance of the self-driven synchronous rectifiers, particularly at high loads. This paper presents a study of the applicability and advantage of the use of the resonant transition in Forward with active clamp and self-driven synchronous rectifiers. The emphasis is on the comparison of the achieved efficiency with different voltage levels over the primary switch prior to turning on. Measurement results show that, at low loads, a reduced voltage level improves the efficiency but, on the other hand, at high loads the advantage is not so significant, or it may be totally lost, mainly due to the increased losses of the self-driven synchronous rectifiers. The paper includes discussion on the effect of the magnetizing inductance on the efficiency of the converter and the optimal voltage level at which the primary switch should be turned on. Measurement results from a 3.4-V 30-A prototype converter are included.  相似文献   

20.
Asymmetric control scheme is an approach to achieve zero-voltage switching (ZVS) for half-bridge isolated dc-dc converters. However, it is not suited for wide range of input voltage due to the uneven voltage and current components stresses. This paper presents a novel "duty-cycle-shifted pulse-width modulated" (DCS PWM) control scheme for half-bridge isolated dc-dc converters to achieve ZVS operation for one of the two switches without causing the asymmetric penalties in the asymmetric control and without adding additional components. Based on the DCS PWM control scheme, an active-clamp branch comprising an auxiliary switch and a diode is added across the isolation transformer primary winding in the half-bridge converter to achieve ZVS for the other main switch by utilizing energy stored in the transformer leakage inductance. Moreover, the auxiliary switch also operates at ZVS and zero-current switching (ZCS) conditions. Furthermore, during the off-time period, the ringing resulted from the oscillation between the transformer leakage inductance and the junction capacitance of two switches is eliminated owing to the active-clamp branch and DCS PWM control scheme. Hence, switching losses and leakage-inductance-related losses are significantly reduced, which provides the converter with the potential to operate at higher efficiencies and higher switching frequencies. The principle of operation and key features of the proposed DCS PWM control scheme and two ZVS half-bridge topologies are illustrated and experimentally verified.  相似文献   