The effect of surface confinement on the electrochemiluminescence (ECL) properties of metallopolymer [Ru(bpy)2(PVP)10]2+, where bpy is 2,2'-bipyridyl and PVP is poly(4-vinylpyridine), is reported. Immobilizing a luminescent material on an electrode surface can substantially modulate its photophysical properties. Significantly, our study revealed that the overall efficiency of the ECL reaction for the metallopolymer film is almost four times higher, at 0.15%, than the highest value obtained for [Ru(bpy)2(PVP)10]2+ dissolved in solution, (phi(ECL) = 0.04%). Electrochemistry has been used to create well-defined concentrations of the quencher Ru3+ within the film. Analysis of both the steady-state luminescence and lifetimes of the film reveals that static quenching by electron transfer between the photoexcited Ru2+ and the Ru3+ centers is the dominant quenching mechanism. The bimolecular rate of electron transfer is (2.5 +/- 0.4) x 10(6) M(-1) s(-1). The implications of these findings for ECL-based sensors, in terms of optimum luminophore loading, is considered.  相似文献   

2.
Choi HN  Cho SH  Lee WY 《Analytical chemistry》2003,75(16):4250-4256
Electrochemical behavior and electrogenerated chemiluminescence (ECL) of tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)3(2+)) immobilized in sol-gel-derived titania TiO2)-Nafion composite films coated on a glassy carbon electrode have been investigated. The electroactivity of Ru(bpy)3(2+) ion exchanged into the composite films and its ECL behavior were strongly dependent upon the amount of Nafion incorporated into the TiO2-Nafion composite films. The ECL sensor of Ru(bpy)32+ immobilized in a TiO2-Nafion composite with 50% Nafion content showed the maximum ECL intensities for both tripropylamine (TPA) and sodium oxalate in 0.05 M phosphate buffer solution at pH 7. Detection limits were 0.1 microM for TPA and 1.0 microM for oxalate (S/N = 3) with a linear range of 3 orders of magnitude in concentration. The present ECL sensor showed improved ECL sensitivity and long-term stability, as compared to the ECL sensors based on pure Nafion films. The present Ru(bpy)3(2+) ECL sensor based on TiO2-Nafion (50%) composite films was applied as an HPLC detector for the determination of erythromycin in human urine samples. The present Ru(bpy)3(2+) ECL sensor was stable in the mobile phase containing a high content of organic solvent (30%, v/v), in contrast to a pure Nafion-based Ru(bpy)3(2+) ECL sensor. The detection limit for erythromycin was 1.0 microM, with a linear range of 3 orders of magnitude in concentration.  相似文献   

3.
Liu J  Yan J  Yang X  Wang E 《Analytical chemistry》2003,75(14):3637-3642
The design and performance of a miniaturized chip-type tris(2,2'-bipyridyl)ruthenium(II) [Ru(bpy)3(2+)] electrochemiluminescence (ECL) detection cell suitable for both capillary electrophoresis (CE) and flow injection (FI) analysis are described. The cell was fabricated from two pieces of glass (20 x 15 x 1.7 mm), and the 0.5-mm-diameter platinum disk was used as working electrode held at +1.15 V (vs silver wire quasi-reference), the stainless steel guide tubing as counter electrode, and the silver wire as quasi-reference electrode. The performance traits of the cell in both CE and FI modes were evaluated using tripropylamine, proline, and oxalate and compared favorably to those reported for CE and FI detection cells. The advantages of versatility, sensitivity, and accuracy make the device attractive for the routine analysis of amine-containing species or oxalate by CE and FI with Ru(bpy)3(2+) ECL detection.  相似文献   

4.
Films containing [Os(bpy)2(PVP)10Cl]+ and [Ru(bpy)2(PVP)10Cl]+ metallopolymers were assembled layer by layer on pyrolytic graphite electrodes to make sensors that selectively detect oxidized DNA. These films showed reversible, independent electrochemistry for electroactive Os3+/Os2+ and Ru3+/Ru2+ centers, with formal potentials of 0.34 and 0.76 V vs SCE, respectively. The combination of ruthenium and osmium metallopolymers in the films provided a catalytic Os square wave voltammetry (SWV) peak that is mainly selective for 8-oxoguanine and the detection of other oxidized nucleobases from the Ru peak. The method is applicable to measurements on DNA in solution or DNA incorporated into films. Using the Os SWV peak, 1 oxidized nucleobase in 6000 was detected. The sensor is simple and inexpensive, and the approach may be useful for the detection of oxidized DNA as a clinical biomarker for oxidative stress.  相似文献   

5.
The voltammetry and electrogenerated chemiluminescence (ECL) of tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)3 2+) ion-exchanged in Nafion and Nafion-silica composite materials have been investigated. The major goal of this work was to investigate and develop new materials and immobilization approaches for the fabrication of ECL-based sensors with improved reactivity and long-term stability. Nation-silica composite materials with varying contents of Nation (53-100 wt% relative to silica) were prepared via the two-step acid/base hydrolysis and condensation of tetramethoxysilane. The Nafion doped sols were spin cast on glassy carbon electrodes, dried, and then ion-exchanged with Ru(bpy)3 2+. The shapes of the cyclic voltammetric curves and the amount of Ru(bpy)3 2+ exchanged into the films strongly depends on the amount of Nafion incorporated into the hybrid sol. Nafion-silica films with a low content of Nafion ion-exchanged less Ru(bpy)3 2+ and exhibited tail-shaped voltammetry at 100 mV/s. The ECL of immobilized Ru(bpy)3 2+ in the presence of either tripropylamine or sodium oxalate in pH 5 acetate buffer was also strongly dependent on the amount of Nafion introduced into the composite with greater ECL observed for the Nafion-silica films relative to pure Nafion.  相似文献   

6.
Chi Y  Duan J  Lin S  Chen G 《Analytical chemistry》2006,78(5):1568-1573
A new flow injection analysis (FIA) system equipped with an electrochemiluminescent (ECL) detector has been developed and applied for the ECL detection of 2-thiouracil. The FIA-ECL system used a specially designed flow-through ECL thin-layer cell to reduce the dead volume, the IR drop across the cell, and the probability of accumulation of gas bubbles in the cell. It was thus envisioned to improve the detection limit of the FIA-ECL method. After being established, the new FIA-ECL system was used to investigate the ECL response of 2-thiouracil in the presence of the ECL of Ru(bpy)3(2+). It was found that 2-thiouracil could enhance the ECL of Ru(bpy)3(2+) over a wide pH range (pH 4.0-12.0). A highly sensitive method for detection of 2-thiouracil in biological samples was developed by the new FIA-ECL system after optimizing several experimental conditions, such as the applied potential of the working electrode, the pH value of the aqueous solution, the flow rate of carrier solution, and the concentration of Ru(bpy)3(2+).  相似文献   

7.
Chi Y  Dong Y  Chen G 《Analytical chemistry》2007,79(12):4521-4528
Electrochemiluminescence (ECL) has been accepted by the analytical chemist as a powerful tool for detection of many inorganic and organic compounds. Ru(bpy)3 2+ has been the most popular ECL system, and many investigations have been focused on the application based on the enhancement or inhibition of Ru(bpy)3 2+ ECL system. However, not much attention has been paid to the theoretical investigation of this ECL system, especially to the inhibiting mechanism for the Ru(bpy)3 2+ ECL system. In the present study, many of the inorganic and organic compounds with electrochemical oxidation activity were found to strongly inhibit Ru(bpy)3 2+ ECL. To explain these inhibited ECL phenomena, a new "electrochemical oxidation inhibiting" mechanism has been proposed via the establishment of a corresponding model. The effects of applied potential, uncompensated resistance, and concentration of inhibitor on the inhibited ECL derived from the model have been verified by experiments. The new ECL inhibition mechanism can be commonly used to explain many kinds of inhibited ECL presently observed, and it is envisioned to result in finding of more inhibitors of this type and establishment of new sensitive ECL detection methods for them.  相似文献   

8.
The electrogenerated chemiluminescence (ECL) of Ru(bpy)3 2+ and tripropylamine, tributylamine, triethylamine, trimethylamine, or sodium oxalate encapsulated within sol-gel-derived silica monoliths have been investigated using an immobilized ultramicroelectrode assembly. The major purpose of this study was to investigate the role of the reductant on the magnitude and stability of the ECL in this solid host matrix. For gel-entrapped Ru(bpy)3 2-/tertiary amines, the shape and intensity of the ECL-potential curves were highly dependent on scan rate. At 10 mV/s, the ECL intensity was ca. 6-fold higher relative to that observed at 500 mV/s. When the ECL acquired at low scan rates was normalized by that obtained in solution under similar conditions, a value of 0.03-0.06 was obtained. In direct contrast, the ECL of the Ru(bpy)3 2+-oxalate system showed little dependence on scan rate, and the ECL was ca. 65-75% of that measured in solution. These differences can be attributed to differences in rotational and translational mobility between the reductants (amines vs oxalate) trapped in this porous solid host For both systems, the ECL was found to be stable upon continuous oxidation or upon drying the gels in a high-humidity environment for over 10 days.  相似文献   

9.
Liposomes ( approximately 100-nm diameter) containing Ru(bpy)32+ (bpy = 2,2'-bipyridine) were prepared as an electrogenerated chemiluminescent (ECL) tag for a sandwich-type immunoassay of human C-reactive protein (CRP). Polyclonal human CRP antibodies were introduced onto liposomes and magnetic beads through biotin-streptavidin interaction. The antigen-antibody conjugates formed on addition of a CRP-containing sample were separated from unreacted species magnetically. Addition of 0.1 M tri-n-propylamine and 0.1 M phosphate buffer (pH 7.6) containing 0.1 M NaCl and 1% (v/v) Triton X-100 caused liberation of the Ru(bpy)32+ from the liposome. ECL obtained in this medium showed a detection limit of 100 ng/mL for human CRP with good linearity of ECL intensity versus antigen concentration over the range 100 ng/mL-10 microg/mL.  相似文献   

10.
Miao W  Bard AJ 《Analytical chemistry》2004,76(18):5379-5386
An ultrasensitive DNA hybridization detection method based on electrogenerated chemiluminescence (ECL) using polystyrene microspheres/beads (PSB) as the carrier of the ECL labels, namely, tris(2,2'-bipyridyl)ruthenium(II) tetrakis(pentafluorophenyl)borate (Ru(bpy)3[B(C6F5)4]2), is reported. Probe single-stranded DNA (p-ssDNA) was attached to the surface of magnetic beads (MB) and hybridized with target-ssDNA (t-ssDNA) with immobilized PSB containing a large number of water insoluble Ru(bpy)3[B(C6F5)4]2 species (approximately 7.5 x 10(9) molecules/bead). With this approach a large amplification factor of Ru(bpy)3[B(C6F5)4]2 molecules for each t-ssDNA can be achieved, when each PSB is attached to a limited number of t-ssDNA. The p-ssDNA-MB <--> t-ssDNA-PSB/Ru(bpy)3(2+) conjugates formed were magnetically separated from the reaction media and dissolved in MeCN containing tri-n-propylamine (TPrA) as an ECL coreactant. ECL was produced with a potential scan from 0 to 3.0 V versus Ag/Ag+, and the integrated ECL intensity was found to be linearly proportional to the t-ssDNA concentration in a range of 1.0 fM to 10 nM under optimized conditions. ECL signals associated with two base pair mismatched ssDNA and noncomplementary ssDNA can be distinguished well from the ECL signal related to the complementary DNA hybridization. A Poisson distribution is followed when a large number of MB reacts with PSB, and the minimum number of 1.0- and 2.8-microm diameter MB required to bind and magnetically separate a single 10-microm diameter PSB from the reaction solution was estimated to be three and one, respectively. The principle described in this paper could be also applied to many other ECL analyses, such as immunoassays.  相似文献   

11.
Ascorbic (H2A) and dehydroascorbic (DA) acids were for the first time directly determined in a single chromatographic run by means of the tris(2,2'-bipyridine)ruthenium(II) (Ru(bpy)(3)2+) based electrogenerated chemiluminescence (ECL) detection. For the first time, it was demonstrated that DA, a nonelectroactive compound, is ECL active and is responsible for the ECL behavior of H2A. This fact, together with the lack of a DA standard, suggested the use of a calibration graph obtained for H2A, for determining both analytes. The proven ECL activity of DA, together with literature data relative to the standard redox potentials of the different species coming from H2A, led to a reconsideration of the proposed ECL reaction mechanism for H2A. The role of the OH- ion in the reaction mechanism of the two analytes appeared to be crucial. H2A and DA could be separated by a suitable C18-reversed-phase HPLC column using an aqueous 30 mM H3PO4 solution as the mobile phase. The optimal ECL response was achieved by polarizing the working electrode at 1.150 Vvs SCE (standard calomel electrode) (oxidation diffusion limiting potential for both H2A and Ru(bpy)(3)2+). The Ru(bpy)(3)2+ solution, at pH 10 for carbonate buffer, was mixed to the eluent solution in a postcolumn system, obtaining, still at pH 10, the final 0.25 mM Ru(bpy)(3)2+ concentration. The detection limit found for the two analytes was 1 x 10(-7) M. The method was successfully applied to the determination of the analytes in a commercially available orange fruit juice.  相似文献   

12.
The electrochemistry and electrogenerated chemiluminescence (ECL) of Ru(bpy)3(2+) (bpy = 2,2'-bipyridyl) were studied in the presence of the nonionic surfactants Triton X-100, Thesit, and Nonidet P40. The anodic oxidation of Ru(bpy)3(2+) produces ECL in the presence of tri-n-propylamine in both aqueous and surfactant solutions. Increases in both ECL efficiency (> or =8-fold) and duration of the ECL signal were observed in surfactant media. A shift to lower energies of the Ru(bpy)3(2+) ECL emission by approximately 8 nm was also observed. The one-electron oxidation of Ru(bpy)3(2+) to Ru(bpy)3(3t) occurs at + 1.03 V vs Ag/AgCl in aqueous buffered (0.2 M potassium phosphate) solution as found by square wave voltammetry. This potential did not shift in surfactant systems, indicating that the redshifts in ECL emission are due to stabilization of ligand pi* orbitals in the metal-to-ligand charge-transfer excited state. These results are consistent with hydrophobic interactions between Ru(bpy)3(2+) and the nonionic surfactants.  相似文献   

13.
Shi L  Liu X  Li H  Xu G 《Analytical chemistry》2006,78(20):7330-7334
A sensitive electrochemiluminescent detection scheme by solid-phase extraction at Ru(bpy)3(2+)-modified ceramic carbon electrodes (CCEs) was developed. The as-prepared Ru(bpy)3(2+)-modified CCEs show much better long-term stability than other Nafion-based Ru(bpy)3(2+)-modified electrodes and enjoy the inherent advantages of CCEs. The log-log calibration plot for dioxopromethazine is linear from 1.0 x 10(-9) to 1.0 x 10(-4) mol L(-1) using the new detection scheme. The detection limit is 6.6 x 10(-10) mol L(-1) at a signal-to-noise ratio of 3. The new scheme improves the sensitivity by approximately 3 orders of magnitude, which is the most sensitive Ru(bpy)3(2+) ECL method. The scheme allows the detection of dioxopromethazine in a urine sample within 3 min. Since Ru(bpy)3(2+) ECL is a powerful technique for determination of numerous amine-containing substances, the new detection scheme holds great promise in measurement of free concentrations, investigation of protein-drug interactions and DNA-drug interactions, pharmaceutical analysis, and so on.  相似文献   

14.
Zhang L  Dong S 《Analytical chemistry》2006,78(14):5119-5123
A novel electrogenerated chemiluminescence (ECL) sensor based on Ru(bpy)3(2+)-doped silica (RuDS) nanoparticles conjugated with a biopolymer chitosan membrane was developed. These uniform RuDS nanoparticles (approximately 40 nm) were prepared by a water-in-oil microemulsion method and were characterized by electrochemical and transmission electron microscopy technology. The Ru(bpy)3(2+)-doped interior maintained its high ECL efficiency, while the exterior nanosilica prevented the luminophor from leaching out into the aqueous solution due to the electrostatic interaction. This is the first attempt to branch out the application of RuDS nanoparticles into the field of ECL, and since a large amount of Ru(bpy)3(2+) was immobilized three-dimensionally on the electrode, the Ru(bpy)3(2+) ECL signal could be enhanced greatly, which finally resulted in the increased sensitivity. This sensor shows a detection limit of 2.8 nM for tripropylamine, which is 3 orders of magnitude lower than that observed at a Nafion-based ECL sensor. Furthermore, the present ECL sensor displays outstanding long-term stability.  相似文献   

15.
A simple procedure to incorporate tris(2-2'-bipyridyl)ruthenium(II), [Ru(bpy)3]2+, into Nafion Langmuir-Schaefer (LS) films is described. Nafion LS films (tens of nanometers thick) were formed on quartz glass and indium tin oxide (ITO) directly from Nafion-[Ru(bpy)3]2+ Langmuir films assembled at the water-air interface. This procedure allowed the direct incorporation of [Ru(bpy)3]2+ into Nafion films without the need for subsequent loading. UV-vis spectroscopy confirmed the successful incorporation of [Ru(bpy)3]2+ within the LS films and showed that the amount of [Ru(bpy)3]2+ immobilized in this way scaled with film thickness. Voltammetric studies on ITO-modified electrodes confirmed the successful incorporation of [Ru(bpy)3]2+ and demonstrated that [Ru(bpy)3]2+ was retained within the ultrathin films over a long time scale. These electrodes were tested for the electrocatalytic reduction of tripropylamine. Significant catalysis was observed due to the rapid turnover of [Ru(bpy)3]2+/3+ between the electrode surface and outer boundary of the film, as a direct consequence of the ultrathin film dimensions. Concomitant electrochemiluminescence (ECL) was demonstrated highlighting the potential of this material for sensing applications.  相似文献   

16.
The unique electrochemiluminescence (ECL) behavior of tris(bipyridine) ruthenium(II) (Ru(bpy)32+) immobilized in a gold/Nafion/Ru(bpy)32+ composite material was investigated. In this composite, the Ru(bpy)32+ ECL was found mainly occurred at 0-0.4 V during the cathodic scan process and the ECL peak was at about 0.1 V, which was quite different to the reported Ru(bpy)32+ ECL. Similar to the generally observed Ru(bpy)32+ ECL, the present ECL also could be enhanced by tri-n-propylamine (TPA). It is also unique that in the presence of TPA, another ECL peak at about 0.38 V occurred. These two ECL peak potentials all could be used as characteristic potential for the ECL determination of TPA.  相似文献   

17.
The electrochemistry, UV-vis absorption, photoluminescence (PL), and coreactant electrogenerated chemiluminescence (ECL) of Ru(bpy)3(2+) (where bpy=2,2'-bipyridine) have been obtained in a series of hydroxylic solvents. The solvents included fluorinated and nonfluorinated alcohols and alcohol/water mixtures. Tri-n-propylamine was used as the oxidative-reductive ECL coreactant. Blue shifts of up to 30 nm in PL emission wavelength maximums are observed compared to a Ru(bpy)3(2+)/H2O standard due to interactions of the polar excited state (i.e., *Ru(bpy)3(2+)) with the solvent media. For example, Ru(bpy)3(2+) in water has an emission maximum of 599 nm while in the more polar hexafluoropropanol and trifluoroethanol it is 562 and 571 nm, respectively. ECL spectra are similar to PL spectra, indicating the same excited state is formed in both experiments. The difference between the electrochemically reversible oxidation (Ru(bpy)3(2+/3+)) and first reduction (Ru(bpy)2(2+/1+)) correlates well with the energy gap observed in the luminescence experiments. Although the ECL is linear in all solvents with [Ru(bpy)3(2+)] ranging from 100 to 0.1 nm, little correlation between the polarity of the solvent and the ECL efficiency (phiecl=number of photons per redox event) was observed. However, dramatic increases in phiecl ranging from 6- to 270-fold were seen in mixed alcohol/water solutions.  相似文献   

18.
Yin XB  Qi B  Sun X  Yang X  Wang E 《Analytical chemistry》2005,77(11):3525-3530
4-(Dimethylamino)butyric acid (DMBA) labeling combined with gold nanoparticle amplification for electrochemiluminescence (ECL) determination of a biological substance (bovine serum albumin (BSA) and immunoglobulin G (IgG) as models) was presented. After DMBA, an analogue of tripropylamine, was tagged on the (anti)analytes, an ECL signal related to the content of the analytes was generated when the analyte tagged with DMBA was in contact with tris(2,2'-bipyridine)ruthenium (Ru(bpy)(3)2+) solution and a potential was applied. To improve the adsorption capacity, a gold nanoparticle layer was first combined into the surface of the 2-mm-diameter gold electrode. For the determination of BSA, avidin was covalently conjugated to a self-assembled monolayer of 3-mercaptopropanoic acid on the gold nanoparticle layer. Biotinylated BSA-DMBA was then immobilized on the gold nanoparticle layer of the gold electrode via the avidin-biotin reaction. IgG was tested via a typical sandwich-type immobilization method. ECL signals were generated from the electrodes immobilized with BSA or IgG by immersing them in a 1 mmol L-1 Ru(bpy)(3)2+ solution and scanning from 0.5 to 1.3 V versus Ag/AgCl. With gold nanoparticle amplification, the ECL peak intensity was proportional to the concentration over the range 1-80 and 5-100 microg/mL for BSA and IgG consuming 50 microL of sample, respectively. A 10- and 6-fold sensitivity enhancement was obtained for BSA and IgG over their direct immobilization on an electrode using DMBA labeling. The relative standard deviations of five replicate determinations of 10 microg/mL BSA and 20 microg/mL IgG were 8.4 and 10.2%, respectively. High biocompatibility and low cost were the main advantages of the present DMBA labeling technique over the traditional Ru(bpy)(3)2+ labeling.  相似文献   

19.
王宇峰  宋娟  关建宁  李鑫  仲慧 《材料导报》2011,25(5):51-54,63
固定联吡啶钌电致化学发光体系因其灵敏度高、可以连续测试、装置简单等优点被广泛应用于分子生物学、化学、药学等领域.各种新材料的运用克服了原有方法稳定性差、重现性差等缺点,拓宽了固定化联吡啶钌电致化学发光的应用范围.介绍了近几年来一些用于固定联吡啶钌新的材料、固定方法及其相关的应用.  相似文献   

20.
Ultrasensitive bioanalytical assays are of great value for early detection of human diseases and pathogens. The sensitivities of immunoassays and DNA probing can be enhanced by multilabeling the biorecognition partner used for affinity-based assays. However, the bioreactivity of biomolecules is affected by a high degree of multilabeling at multiple functional sites. It is proposed that dendritic scaffoldings be used to link multiple signal-generating units to a single site with potentially minimum impact on the bioaffinity. A prototype label, a zeroth-generation dendron, bearing three [Ru(bpy)(3)](2+) units for electrochemiluminescence (ECL) assays was synthesized and characterized preliminarily by spectroscopic, electrochemical, and ECL methods. No evidence of interaction between the neighboring [Ru(bpy)(3)](2+) units in the label molecule was found from these characterizations. Both the photoluminescence and ECL of the prototype label have features very similar to those of mononuclear [Ru(bpy)(3)](2+) compounds. Labeling a model protein with a triad of [Ru(bpy)(3)](2+) at one NH(2) position was demonstrated. The results reported here provide support to applying the proposed multilabeling strategy to affinity-based bioanalytical assays.  相似文献   