首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The morphology of the normal human and rat articular cartilage was assessed using transmission electron microscopy (TEM), atomic force microscopy (AFM), and two-photon excitation (2PE) microscopy. Spurr-embedded sections from fixed human cartilage were simultaneously evaluated using TEM and AFM. The presences of tracks among the chondrocytes from the superficial zone of the cartilage were observed. In order to ratify the presence of interconnecting tracks among superficial zone chondrocytes, whole fixed human and rat cartilage, as well as fresh whole rat cartilage, were examined under the 2PE. In all cases, these tracks were observed. In addition, porous matrix, well-defined lacunae, and cytoplasmic projections anchored to the extracellular matrix (ECM) were also detected. We conclude that normal human and rat flattened superficial chondrocytes might be interconnected by tracks running through the ECM. In addition, cytoplasmic projections were observed anchored to the ECM. All these structures may possibly be related to cell/cell and ECM/chondrocytes signaling. Our findings provide new information that possibly will be of relevant importance for a more profound study of normal cartilage physiology and eventually, the pathogenesis of osteoarthritis.  相似文献   

2.
A novel sample holder that allows atomic force microscopy (AFM) to be performed on transmission electron microscope (TEM) grids is described. Consequently, AFM and TEM images were repeatedly obtained on exactly the same sample area. For both techniques, a thin carbon film was used as the imaging substrate. Although these techniques have been previously used in conjunction, AFM and TEM images on exactly the same area have not been repeatedly obtained for any system. Correlation of AFM and TEM images is useful for work where the three‐dimensional topographical information provided by the AFM could be used to better interpret the two‐dimensional images provided by the TEM and vice versa. To demonstrate the applicability of such correlation, new results pertaining to a fibrillar collagen system are summarized.  相似文献   

3.
4.
Using transmission electron microscopy (TEM) and scanning force microscopy (SFM) together, it was possible to verify important structural features of a nanostructured bulk material such as the kp‐morphology in an ABC triblock copolymer. By applying suitable imaging techniques during the SFM measurements it was possible to determine the morphology without additional manipulation steps in between. In comparison, TEM investigations on this type of material usually require selective staining procedures prior to the measurement. Also electron beam damage is often encountered during TEM measurements especially if components such as poly(methacrylates) are present. In contrast, SFM measurements can be assumed not to significantly change the phase dimensions of the components.  相似文献   

5.
In order to examine histological sections of the rat vomeronasal epithelium with the atomic force microscope (AFM), we developed an electron beam etching method that improves the resolution of AFM images. This method results in AFM images comparable to those obtained with the transmission electron microscope (TEM). Ultrathin tissue sections embedded in epoxy resin were observed before and after the treatment with electron beam radiation. Before electron beam treatment, epithelial structures such as the microvilli surface, dendritic processes, the supporting cell layers and the neuronal cell layers were all visible using the AFM. However, only a few subcellular structures could also be resolved. The AFM images were not as clear as those obtained with the TEM. After electron beam treatment, however, the resolution of AFM images was greatly improved. Most of the subcellular structures observed in TEM images, including the inner membrane of mitochondria, ciliary-structure precursor body, junctional complexes between the neurons and supporting cells, and individual microvilli were now visible in the AFM images. The electron beam treatment appeared to melt the embedding resin, bringing subcellular structures into high relief. The result of this study suggests that electron beam etching of histological samples may provide a new method for the study of subcellular structure using the AFM.  相似文献   

6.
7.
We calculate a universal shift in work function of 59.4 meV per decade of dopant concentration change that applies to all doped semiconductors and from this use Monte Carlo simulations to simulate the resulting change in secondary electron yield for doped GaAs. We then compare experimental images of doped GaAs layers from scanning electron microscopy and conductive atomic force microscopy. Kelvin probe force microscopy allows to directly measure and map local work function changes, but values measured are often smaller, typically only around half, of what theory predicts for perfectly clean surfaces.  相似文献   

8.
R. Wurster  B. Ocker 《Scanning》1993,15(3):130-135
Metallic nanoparticles have been produced on vitreous carbon substrates by means of thermal evaporation. From pictures of the particles, made by a high-resolution scanning electron microscope (HRSEM), a semispherical shape is suggested due to the total mass of deposited material. Atomic force microscopy (AFM) has been applied to this sample in order to get direct topographic information. The AFM has been operated with normal and super tips, the latter having a smaller cone angle and radius, thus following more precisely the contours of an object. Simultaneously lateral-force microscopic (LFM) images have been recorded. Major differences between the contents of HRSEM- and AFM-images are considered, emphasizing the important influence of the tips' geometry. Both the AFM and LFM line scans have been compared with and have qualitatively agreed with those calculated under simplifying assumptions.  相似文献   

9.
The effect of acid etching on root dentine was analyzed with Atomic Force Microscopy using a liquid cell that allowed image acquisition while the sample was kept in contact with the etching solution. The time evolution of the etching process was evaluated both qualitatively and quantitatively. Image sequences against etching time were obtained showing a clear trend of surface cleaning and opening of dentine tubules. Image analysis methods were employed to quantify the changes on the dentine surface, through the detection and morphological measurement of dentine tubules over time. The measurements indicated an overall increase in the diameter of the tubules against time, with a saturation value between 3.5 and 5.5 μm reached after approximately 300 seconds.  相似文献   

10.
Recently we reported a simple method for obtaining both monolayer thickness and surface patterning using self-assembled monolayers (SAMs). Here we presented a straightforward method for controlling the formation of SAMs over surfaces useful for both chemical and biological applications. Atomic force microscopy (AFM) has been used to investigate the growth mechanism and formation of octadecylsiloxane (ODS) films obtained using a less-reactive silane; octadecyltrimethoxysilane (OTMS). SAMs formation from both OTMS and octadecyltrichlorosilane (ODTS) differ in the hydrolysis step where ODTS results in hydrochloric acid formation, which may affect the delicate features on surfaces. On the other hand, OTMS does not show this behavior. In contrast to monolayer formation from chlorosilane precursors, methoxysilane SAMs have been studied less extensively. Our observations highlight the importance of controlling water content during the formation of ODS monolayers in order to get well-ordered SAMs. We have also seen that, like ODTS, OTMS exhibits monolayer growth through an island expansion process but with a comparatively slow growth rate and different island morphology. The average height of islands, surface coverage, contact angle and root-mean-square (RMS) roughness increase with OTMS adsorption time in a consecutive manner.  相似文献   

11.
Atomic force microscopy (AFM) and scanning electron microscopy with energy dispersive spectroscopy (SEM-EDS) have been used for both morphological and elemental mass analysis study of atmospheric particles. As part of the geometrical particle analysis, and in addition to the traditional height profile measurement of individual particles, AFM was used to measure the volume relative to the projection area for each particle separately, providing a particle shape model. The element identification was done by the EDS analysis, and the element mass content was calculated based on laboratory calibration with particles of known composition. The SEM-EDS mass measurements from two samples collected at 150 and 500 m above the surface of the Mediterranean Sea were found to be similar to mass calculations derived from the AFM volume measurements. The AFM results show that the volume of most of the aerosols that were identified as soluble marine sulfate and nitrate aerosol particles can be better estimated using cylindrical shapes than spherical or conical geometry.  相似文献   

12.
The objective of this study was to analyze the dentin‐resin cements interfacial ultramorphologies using two different methods: scanning (SEM) and transmission electron microscopy (TEM). Four commercial products were evaluated: two conventional cementing system (RelyX ARC/Adper? Scotchbond? Multi‐Purpose Plus, 3M ESPE and Clearfil Esthetic Cement/DC Bond, Kuraray) and two self‐adhesive resin cements (RelyX Unicem, 3M ESPE and Clearfil SA Cement, Kuraray). Prepolymerized resin disks (Sinfony, 3M ESPE) were cemented on oclusal dentin surfaces of 24 third human molars, simulating the indirect restorations. After 24 h, teeth were sectioned into 0.9‐mm thick slabs and processed for microscopy analyses (SEM or TEM/ n = 3). Qualitative characterization of dentin‐resin cement interface was performed. Hybrid layer formation with long and dense resin tags was observed only for RelyX ARC cementing system. Clearfil Esthetic Cement/DC Bond system revealed few and short resin tags formation, whereas no hybridization and resin tags were detected for self‐adhesive resin cements. Some interfacial regions exhibited that the self‐adhesive resin cements were not bonded to dentin, presenting bubbles or voids at the interfaces. In conclusion, TEM and SEM bonding interface analyses showed ultramorphological variations among resin cements, which are directly related to dental bonding strategies used for each resin cement tested. Microsc. Res. Tech. 76:1234–1239, 2013. © 2013 Wiley Periodicals, Inc.  相似文献   

13.
Environmental or in situ electron microscopy means the observation of material in its native environment, which can be gaseous or liquid, as compared to more traditional post‐mortem electron microscopy carried out under (ultra) high vacuum conditions. Experiments can be performed on bulk samples in scanning electron microscopes or on thinned samples in transmission (scanning) electron microscopes. In the latter, the movement, in real time and in situ, of nanoparticles, clusters or even single atoms on the surfaces of thinned material or within a liquid can be observed. It is argued here that due to the changes that a specimen typically undergoes during in situ observation, electron irradiation effects are difficult to evaluate and so thermodynamic parameters, such as activation energies for diffusion and segregation, which are governed by movements of only a minority of atoms in the specimen, cannot be reliably determined because of the potentially high energy transfer by the irradiating electron beam to some atoms in the sample. In order to measure diffusivities reliably, radiation effects and surface diffusion need to be excluded or kept minimal so as not to disturb the measurements, which can be checked by repeating experiments and comparing results as function of time and dose for the same position, at different positions or for different specimen thicknesses. Kinetic measurements of nucleation and growth phenomena, such as Ostwald ripening, are possibly influenced to a far lesser degree by irradiation effects, as a majority of atoms actively participate in these processes and if a small fraction of them will get extra energy from the irradiation process then their influence on the overall kinetics may be rather minor.  相似文献   

14.
Cytoskeleton fibers form an intricate three-dimensional network to provide structure and function to microvessel endothelial cells. During accommodation to blood flowing, stress fiber bundles become more prominent and align with the direction of blood flow. This network either mechanically resists the applied shear stress (lateral force) or, if deformed, is dynamically remodeled back to a preferred architecture. However, the detailed response of these stress fiber bundles to applied lateral force at submicrometer scales are as yet poorly understood. In our in vitro study, the tip, topography probe in lateral force microscopy of atomic force microscopy, acted as a tool for exerting quantitative vertical and lateral force on the filaments of the cytoskeleton. Moreover, the authors developed a formula to calculate the value of lateral force exerted on every point of the filaments. The results show that cytoskeleton fibers of healthy tight junctions in rat cerebral microvessel endothelial cells formed a cross-type network, and were reinforced and elongated in the direction of scanning under lateral force of 15-42 nN. Under peroxidation (H(2)O(2) of 300 micromol/L), the cytoskeleton remodeled at intercellular junctions, and changed over the meshwork structures into a dense bundle, that redistributed the stress. Once mechanical forces were exerted on an area, the cells shrank and lost morphologic tight junctions. It would be useful in our understanding of certain pathological processes, such as cerebral ischemia/reperfusion injury, which maybe caused by biomechanical forces and which are overlooked in current disease models.  相似文献   

15.
We have investigated the nanotexture and crystallographic orientation of aragonite in a coral skeleton using synchrotron-based scanning transmission X-ray microscopy (STXM) and transmission electron microscopy (TEM). Polarization-dependent STXM imaging at 40-nm spatial resolution was used to obtain an orientation map of the c-axis of aragonite on a focused ion beam milled ultrathin section of a Porites coral. This imaging showed that one of the basic units of coral skeletons, referred to as the center of calcification (COC), consists of a cluster of 100-nm aragonite globules crystallographically aligned over several micrometers with a fan-like distribution and with the properties of single crystals at the mesoscale. The remainder of the skeleton consists of aragonite single-crystal fibers in crystallographic continuity with the nanoglobules comprising the COC. Our observation provides information on the nm-scale processes that led to biomineral formation in this sample. Importantly, the present study illustrates how the methodology described here, which combines HRTEM and polarization-dependent synchrotron-based STXM imaging, offers an interesting new approach for investigating biomineralizing systems at the nm-scale.  相似文献   

16.
The structure and surface chemistry of soil particles has extensive impact on many bulk scale properties and processes of soil systems and consequently the environments that they support. There are a number of physiochemical mechanisms that operate at the nanoscale which affect the soil's capability to maintain native vegetation and crops; this includes soil hydrophobicity and the soil's capacity to hold water and nutrients. The present study used atomic force microscopy in a novel approach to provide unique insight into the nanoscale properties of natural soil particles that control the physiochemical interaction of material within the soil column. There have been few atomic force microscopy studies of soil, perhaps a reflection of the heterogeneous nature of the system. The present study adopted an imaging and force measurement research strategy that accounted for the heterogeneity and used model systems to aid interpretation. The surface roughness of natural soil particles increased with depth in the soil column a consequence of the attachment of organic material within the crevices of the soil particles. The roughness root mean square calculated from ten 25 microm(2) images for five different soil particles from a Netherlands soil was 53.0 nm, 68.0 nm, 92.2 nm and 106.4 nm for the respective soil depths of 0-10 cm, 10-20 cm, 20-30 cm and 30-40 cm. A novel analysis method of atomic force microscopy phase images based on phase angle distribution across a surface was used to interpret the nanoscale distribution of organic material attached to natural and model soil particles. Phase angle distributions obtained from phase images of model surfaces were found to be bimodal, indicating multiple layers of material, which changed with the concentration of adsorbed humic acid. Phase angle distributions obtained from phase images of natural soil particles indicated a trend of decreasing surface coverage with increasing depth in the soil column. This was consistent with previous macroscopic determination of the proportions of organic material chemically extracted from bulk samples of the soils from which specimen particles were drawn. Interaction forces were measured between atomic force microscopy cantilever tips (Si(3)N(4)) and natural soil and model surfaces. Adhesion forces at humic acid free specimen surfaces (Av. 20.0 nN), which are primarily hydrophilic and whose interactions are subject to a significant contribution from the capillary forces, were found to be larger than those of specimen surfaces with adsorbed humic acid (Av. 6.5 nN). This suggests that adsorbed humic acid increased surface hydrophobicity. The magnitude and distribution of adhesion forces between atomic force microscopy tips and the natural particle surfaces was affected by both local surface roughness and the presence of adsorbed organic material. The present study has correlated nanoscale measurements with established macroscale methods of soil study. Thus, the research demonstrates that atomic force microscopy is an important addition to soil science that permits a multiscale analysis of the multifactorial phenomena of soil hydrophobicity and wetting.  相似文献   

17.
A cross-sectional sample preparation technique is described that relies on lithographic and dry-etching processing, thus avoiding metallographic polishing and ion milling. The method is capable of producing cross-sectional transmission electron microscopy samples with a large amount of transparent area (1 μm × 2.5 mm) which allows the examination of many patterned test sites on the same sample from the same chip of a silicon wafer. An example of the application of the technique is given for localized oxidation through a mask.  相似文献   

18.
Multivalent ions in solution are known to mediate attraction between two like‐charged molecules. Such attraction has proved useful in atomic force microscopy (AFM) where DNA may be immobilized to a mica surface facilitating direct imaging in liquid. Theories of DNA immobilization suggest that either ‘salt bridging’ or fluctuation in the positions of counter ions about both the mica surface and DNA backbone secure DNA to the mica substrate. Whilst both theoretical and experimental evidence suggest that immobilization is possible in the presence of divalent ions, very few studies identify that such immobilization is possible with monovalent ions. Here we present direct AFM evidence of DNA immobilized to mica in the presence of only monovalent ions. Our data depict E. coli plasmid pBR322 adsorbed onto the negatively charged mica both after short (10 min) and long (24 h) incubation periods. These data suggest the need to re‐explore current theories of like‐charge attraction to include the possibility of monovalent interactions. We suggest that this DNA immobilization strategy may offer the potential to image natural processes with limited immobilization forces and hence enable maximum conformational freedom of the immobilized biomolecule.  相似文献   

19.
We used different methods to modify a mica surface with 3-aminopropyltriethoxysilane (APTES), and then used it as substrate to immobilize DNA for atomic force microscopy (AFM) observation. The evaporation method and solution modifying method were investigated and evaluated. The solution modifying method was found to be relatively simple and effective. Using an APTES solution-modified mica surface, DNA immobilization appeared more reproducible and it could be imaged in liquid. The mixed solution of APTES and DNA was dropped directly onto the mica surface for AFM imaging. We found that DNA can condense in APTES water solutions. Toroids, rods and intermediate structures of condensation were captured by AFM.  相似文献   

20.
In the absence of high-order aberrations, the lattice fringe technique should allow measurement of grain boundary rigid-body displacements to accuracies about an order of magnitude better than the point-to-point resolution of the transmission electron microscope. The three-fold astigmatism, however, introduces shifts of the lattice fringe pattern that depend on the orientation of the lattice relative to the direction of the three-fold astigmatism and thus produces an apparent shift between the two grains bordering the grain boundary. By image simulation of grain boundary model structures, the present paper explores the effect of these extraneous shifts on grain boundary volume expansion measurements. It is found that the shifts depend, among others, on zone axis direction and the magnitude of the lattice parameter. For many grain boundaries of interest, three-fold astigmatism correction to better than 100 nm appears necessary to achieve the desired accuracies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号