共查询到20条相似文献,搜索用时 140 毫秒
1.
2.
3.
高频红外碳硫分析助熔剂选择 总被引:2,自引:1,他引:1
燃烧法测定碳硫时,为使样品中的碳硫充分氧化,需添加一些助熔剂.助熔剂的主要作用是提供样品氧化热量,改变熔化特性,使燃烧稳定,覆盖样品防止飞溅.助熔剂选择合适,用量适当会加速样品氧化熔融,可提高碳硫的释放率和测定精度. 相似文献
4.
5.
采用HIR-944型红外碳硫分析仪测定氯化银中硫的含量,并对样品作了测定前的预处理,为氯化银中硫的测定选择了较为合适的分析条件,有效地降低了氯化银在分析过程中的污染。 相似文献
6.
7.
在采用光电光谱仪分析钢的化学成分时,应用两套国家低合金钢标准样品和一套自制二级标准样品绘制工作曲线后分析钢中碳、硅、锰、磷、硫的含量,结果证实,由于被测试样与国家标准试样组织结构不同而引起分析误差较大,而自制试样准确度理想。 相似文献
8.
本文总结了系列碳硫专用钢冶金行业标准样品的研制工作。对样品的冶炼、加工、均匀性检验、定值分析及标准值确定了工作作了详细论述。均匀性检验采用单元内单次测量方法,样品均匀性良好。确定了C、S、Si、Mn、P、Ni、Cr、Mo化学成份的标准值,定值精度达国内先进水平。填补了西南片区无碳硫专用钢标样的空白。本标本样品适用于分析检测,控制产品质量,较准分析仪器,及实验室的质量管理。 相似文献
9.
10.
11.
N. ABDENOURI A. BELGHIT R. BERJOAN G. PERAUDEAU G. FLAMANT 《Mineral Processing and Extractive Metallurgy Review》2013,34(4):287-312
The total extraction of sulfur by vaporization from iron sulfide ores leads to a residue that is constituted in great part of iron. The aim of this article is to follow up the secondary metals composition in the residue during the sulfur extraction. When the pyrrhotite is treated alone, copper is completely evaporated after Cu2S decomposition. While in the presence of carbon, iron is present as the core form in the iron sulfide. In this case, the kinetic of vaporization is fast and no secondary metals trace is detected in the iron core. 相似文献
12.
通过在铅锑精矿焙烧时加入一定量的氧化锌或氧化钙,使铅锑精矿在灼烧过程中的单质硫、有机质、硫化物、碳充分焙烧,然后采用王水分解矿样,活性炭动态吸附富集金,灰化除碳,王水溶解,原子吸收光度法测定铅锑精矿中金含量,方法快速、准确,同时适用于含碳、硫较高焙烧时易结块的精矿样品。 相似文献
13.
会计账目差错会对会计报告产生影响,特别是一些重要的会计账目差错会误导管理者或者投资人作出错误的决策.文章对会计账目形成差错的情况做了分类,并认真分析了差错产生的原因,有利于会计、审计人员减少或及时发现和纠正会计账目差错. 相似文献
14.
考虑到低合金钢试样加入钨锡助熔剂后试样燃烧释放完全,其坩埚内部比生铁试样埚底光滑,埚壁迸溅少,且二次坩埚的成本更低,故选择分析完低合金钢的坩埚作为二次坩埚用于磷铁中碳和硫的分析。实验表明,在二次坩埚中加入0.40~0.55g试样、1.2~1.3g钨锡助熔剂,无需空白校正即可实现高频燃烧红外吸收法对磷铁中碳和硫元素的同时测定。由于磷铁标准样品较少,不足以覆盖所有磷铁中碳或硫的含量范围,所以通过将低合金钢标准样品和磷铁标准样品ZBT384进行两两混合(总质量控制在(0.5±0.05)g之间)以配制校准样品系列。结果表明,碳在质量分数为0.05%~0.65%范围内,硫在质量分数为0.005%~0.14%范围内的校准曲线线性关系良好,碳和硫的相关系数分别为0.999 6和0.999 5。将实验方法应用于磷铁实际样品分析,测得碳和硫的相对标准偏差(RSD,n=7)分别为2.0%和3.5%。按照实验方法对磷铁标准样品和内控样品进行测定,测得结果与认定值或参考值的绝对误差均小于国家标准方法 YB/T 5339—2015或YB/T 5341—2015要求的允许差。 相似文献
15.
The feasibility of examining medical gases for trace impurities, using an infrared spectrophotometer in conjunction with a 10 m gas cell, was investigated. Many of the impurities for which the USP includes limits were detected and measured at concentrations at or below those permitted by the USP; these include sulfur dioxide, carbon dioxide, carbon monoxide, and water. However, others (hydrogen sulfide, nitric oxide, and nitrogen dioxide) were not detected at these levels by this technique. Methane was found at low levels in some samples. 相似文献
16.
The kinetics of decarburization of liquid iron have been studied between 1160 and 1600°C under conditions where mass transport
of reactants is not rate determining. Studies with continuously carbon-saturated iron and of iron with varying carbon concentration
have been used to show that the slow step at high concentrations of carbon is independent of carbon concentration and is first
order with respect to the pressure of CO2. For high purity iron, the forward rate constant, in mole cm2 s-1 atm-1, is given by the equation ln kf = -11,700/T-0.48. It is concluded that the data are consistent with the chemisorption process as the rate limiting step.
A marked sensitivity of the rate to trace amounts of sulfur has been found and it is shown that this is consistent with ideal
adsorption of sulfur and is in fair accord with the existing measurements of the depression of the surface tension of iron-carbon
alloys by sulfur.
D. R. Sain was formerly a Graduate Student. 相似文献
17.
CO还原烧结矿过程中的析碳行为 总被引:1,自引:0,他引:1
高炉中CO 还原烧结矿过程中会发生析碳反应,对高炉操作产生不利的影响。采用 CS-8800型高频红外碳硫分析仪分析CO 还原烧结矿过程中的析碳行为,并采用 Nova400NanoSEM型场发射扫描电子显微镜分析还原后烧结矿微观结构。研究结果表明:随着温度的升高,析碳反应 CO 的平衡浓度越高,反应越难发生。在低温下析出的碳较多,析出的碳主要分布在烧结矿表面和气孔中,而在温度较高时只有微量碳析出;体系中 CO2对析碳反应有明显的抑制作用;析碳量随着还原时间的增加而增加。 相似文献
18.
镍转化炉是色谱仪利用氢火焰离子化检测器进行微量一氧化碳、二氧化碳分析的重要部件,其转化率直接影响到仪器对微量一氧化碳、二氧化碳分析的灵敏度。通过试验给出了定量测定转化率的可靠方法。 相似文献
19.
20.
介绍了张家堡子地区铅锌矿的成矿地质条件,总结了该区铅锌矿的成矿地质特征。通过对该区硫同位素,碳、氧等同位素数据的分析,认为张家堡子地区铅锌矿成矿物质主要来源于地层,矿床成因类型为层控型矿床。 相似文献