1.
The potential of punched winglet type vortex generator (VG) arrays used to enhance air-side heat-transfer performance of finned tube heat exchanger is numerically investigated. The arrays are composed of two delta-winglet pairs with two layout modes of continuous and discontinuous winglets. The heat transfer performance of two array arrangements are compared to a conventional large winglet configuration for the Reynolds number ranging from 600 to 2600 based on the tube collar diameter, with the corresponding frontal air velocity ranging from 0.54 to 2.3 m/s. The effects of different geometry parameters that include attack angle of delta winglets (β = 10 deg, β = 20 deg, β = 30 deg) and the layout locations are examined. The numerical results show that for the punched VG cases, the effectiveness of the main vortex to the heat transfer enhancement is not fully dominant while the “corner vortex” also shows significant effect on the heat transfer performance. Both heat transfer coefficient and pressure drop increase with the increase of attack angle β for the side arrangements; the arrays with discontinuous winglets show the best heat transfer enhancement, and a significant augmentation of up to 33.8–70.6% in heat transfer coefficient is achieved accompanied by a pressure drop penalty of 43.4–97.2% for the 30 deg case compared to the plain fin. For the front arrangements of VGs higher heat transfer enhancement and pressure drop penalty can be obtained compared to that of the side arrangement cases; the case with front continuous winglet arrays has the maximum value of j/f, a corresponding heat transfer improvement of 36.7–81.2% and a pressure drop penalty of 60.7–135.6%.  相似文献   

2.
《Applied Thermal Engineering》2007,27(11-12):1806-1816
In this study, the heat transfer enhancement and pressure drop values of seven different fin angles with plain fin-tube heat exchangers were investigated. The numerical simulation of the fin-tube heat exchanger was performed by using a three dimensional (3-D) numerical computation technique. Therefore, a CFD computer code, the FLUENT was used to solve the equation for the heat transfer and pressure drop analyses in the fin-tube heat exchanger. The model drawing was created and meshed by using GAMBIT software. The heat transfer and pressure drop values of the vertical fin angle (θ = 0°) were provided to compare with variable inclined fin angles (θ = 5°, 10°, 15°, 20°, 25°, 30°). The heat transfer values were normalized to compare all cases. For inclined fin angle θ = 30°, which is the optimum angle, the maximum heat transfer enhancement per segment was obtained 1.42 W (the normalized value 105.24%), the maximum loss power associated with pressure drop per segment was only 0.54 mW.  相似文献   

3.
The article presents an experimental investigation on thermal performance enhancement in a constant heat-fluxed square duct fitted with combined twisted-tape and winglet vortex generators. The experiments are carried out for the airflow rate through the tested square duct fitted with both the vortex generators for Reynolds number from 4000 to 30,000. The effect of the combined twisted tape and rectangular winglet inserts on heat transfer and pressure drop presented in terms of respective Nusselt number and friction factor is experimentally investigated. The characteristics of the combined twisted-tape and winglet include two twist ratios (Y = 4 and 5), three winglet- to duct-height ratios, (RB = 0.1, 0.15 and 0.2), four winglet-pitch to tape-width ratios, (RP = 2, 2.5, 4 and 5) and a single attack angle of winglet, α = 30°. The experimental results reveal that the Nusselt number and friction factor for the combined twisted-tape and V-winglet increase with increasing RB but decreasing RP. The inserted duct at RB = 0.2, RP = 2 and Y = 4 provides the highest heat transfer rate and friction factor but the one at RB = 0.1, RP = 2 and Y = 4 yields the highest thermal performance. The application of combined vortex-flow devices gives thermal performance around 17% higher than the twisted tape alone.  相似文献   

4.
This paper describes the numerical evaluation of a novel cross flow tube bundle heat exchanger that combines tubes of different diameter in an inline arrangement for the purpose of reducing gas side particulate fouling rates while preserving acceptable levels of heat transfer and pressure drop performance. Three arrangements are compared: a common inline tube bundle heat exchanger with cylinders of equal diameter and two other arrangements that consist of alternately placed cylinders with a diameter ratio of d/D = 0.5, at two different transverse spacings. Numerical calculations are performed in order to study heat transfer, pressure drop and fouling rates from flue gases with suspended ash particles. The alternating tube sizes achieve a suppression of the vortex shedding mechanism that has previously been shown to enhance downstream particle deposition. Results show that, compared to the standard arrangement, the tube bundle with unequal cylinders placed at the largest transverse spacing achieves a significant (~30%) reduction in particle deposition rate without sacrificing acceptable values of heat transfer per unit volume and low pressure drop.  相似文献   

5.
6.
Three-dimensional numerical study was performed for heat transfer characteristics and fluid flow structure of fin-and-oval-tube heat exchangers with longitudinal vortex generators (LVGs). For Re (based on the hydraulic diameter) ranges from 500 to 2500, it was found that the average Nu for the three-row fin-and-oval-tube heat exchanger with longitudinal vortex generators increased by 13.6–32.9% over the baseline case and the corresponding pressure loss increased by 29.2–40.6%. The results were analyzed on the basis of the field synergy principle to provide fundamental understanding of the relation between local flow structure and heat transfer augmentation. It was confirmed that the reduction of the intersection angle θ between the velocity field and the temperature field was one of the essential factors influencing heat transfer enhancement. Three geometrical parameters – placement of LVGs (upstream and downstream), angles of attack (α = 15°, 30°, 45° and 60°) and tube-row number (n = 2, 3, 4 and 5) – were also investigated for parameter optimization. The LVGs with placement of downstream, angles of attack α = 30° and minimum tube-row number provide the best heat transfer performance. The effects of the three geometrical parameters on heat transfer enhancement were also analyzed from the view point of the field synergy principle and it was found that the results can be well explained by the field synergy principle.  相似文献   

7.
This paper presents the influences of main parameters of longitudinal vortex generator (LVG) on the heat transfer enhancement and flow resistance in a rectangular channel. The parameters include the location of LVG in the channel, geometric sizes and shape of LVG. Numerical results show that the overall Nusselt number of channel will decrease with the LVGs’ location away from the inlet of the channel, and decrease too with the space between the LVG pair decreased. The location of LVG has no significant influence on the total pressure drop of channel. With the area of LVG increased, the average Nusselt number and the flow loss penalty of channel, especially when β = 45° will increase. With the area of LVG fixed, increasing the length of rectangular winglet pair vortex generator will bring about more heat transfer enhancement and less flow loss increase than that increasing the height of rectangular winglet pair vortex generator. With the same area of LVG, delta winglet pair is more effective than rectangular winglet pair on heat transfer enhancement of channel, and delta winglet pair-b is more effective than delta winglet pair-a. Delta winglet pair-a results in a higher pressure drop, the next is rectangular winglet pair and the last is delta winglet-b. The increase of heat transfer enhancement is always accompanied with the decrease of field synergy angle between the velocity and temperature gradient when the parameters of LVG are changed. This confirms again that the field synergy is the fundamental mechanism of heat transfer by longitudinal vortex. The laminar heat transfer of the channel with punched delta winglet pair is experimentally and numerically studied in the present paper. The numerical result for the average heat transfer coefficient of the channel agrees well with the experimental result, indicating the reliability of the present numerical predictions.  相似文献   

8.
This study is to experimentally investigate the heat transfer enhancement by delta winglet vortex generators in air cooling of a staggered array of rectangular electronic modules. The winglet vortex generators are placed in front of 3 × 5 modules with 20° attack angle. Each module has dimensions of 1.8 × 5.4 × 0.6 mm and each one generates heat at 2.5 W. The adiabatic heat transfer coefficients, the thermal wake functions including their correlations for the modules with and without the vortex generators are considered at different values of Reynolds number and the module density. It could be seen that the vortex generators could enhance the adiabatic heat transfer coefficients, reduce the thermal wake functions and the module temperatures significantly. The module temperatures predicted by the superposition of the convective effect due to the module heat generations and the module thermal wakes are fitted very well with the measured data.  相似文献   

9.
A three-dimensional study of laminar flow and heat transfer in a channel with built-in oval tube and delta winglets is carried out through the solution of the complete Navier-Stokes and energy equations using a body-fitted grid and a finite-volume method. The geometrical configuration represents an element of a gas-liquid fin-tube cross-flow heat exchanger. The size of such heat exchangers can be reduced through enhancement of transport coefficients on the air (gas) side, which are usually small compared to the liquid side. In a suggested strategy, oval tubes are used in place of circular tubes, and delta-winglet type vortex generators in various configurations are mounted on the fin-surface. An evaluation of the strategy is attempted in this investigation. The investigation is carried out for different angles of attack of the winglets to the incoming flow for the case of two winglet pairs. The variation of axial location of the winglets is also considered for one pair of winglets mounted in common-flow-down configuration. The structures of the velocity field and the heat transfer characteristics have been presented. The results indicate that vortex generators in conjunction with the oval tube show definite promise for the improvement of fin-tube heat exchangers.  相似文献   

10.
The two-phase heat transfer coefficient and pressure drop of pure HFC-134a condensing inside a smooth helically coiled concentric tube-in-tube heat exchanger are experimentally investigated. The test section is a 5.786 m long helically coiled double tube with refrigerant flowing in the inner tube and cooling water flowing in the annulus. The inner tube is made from smooth copper tubing of 9.52 mm outer diameter and 8.3 mm inner diameter. The outer tube is made from smooth copper tubing of 23.2 mm outer diameter and 21.2 mm inner diameter. The heat exchanger is fabricated by bending a straight copper double-concentric tube into a helical coil of six turns. The diameter of coil is 305 mm. The pitch of coil is 35 mm. The test runs are done at average saturation condensing temperatures ranging between 40 and 50 °C. The mass fluxes are between 400 and 800 kg m−2 s−1 and the heat fluxes are between 5 and 10 kW m−2. The pressure drop across the test section is directly measured by a differential pressure transducer. The quality of the refrigerant in the test section is calculated using the temperature and pressure obtained from the experiment. The average heat transfer coefficient of the refrigerant is determined by applying an energy balance based on the energy rejected from the test section. The effects of heat flux, mass flux and, condensation temperature on the heat transfer coefficients and pressure drop are also discussed. It is found that the percentage increase of the average heat transfer coefficient and the pressure drop of the helically coiled concentric tube-in-tube heat exchanger, compared with that of the straight tube-in-tube heat exchanger, are in the range of 33–53% and 29–46%, respectively. New correlations for the condensation heat transfer coefficient and pressure drop are proposed for practical applications.  相似文献   

11.
This study investigated the effect of fin thickness on the air-side performance of wavy fin-and-tube heat exchangers under dehumidifying conditions. A total of 10 samples were tested with associated fin thickness (δf) of 0.115 mm and 0.25 mm, respectively. For a heat exchanger with two rows (N = 2) and fin pitch Fp of 1.41 mm, the effect of fin thickness on the heat transfer coefficient is more pronounced. The heat transfer coefficients for δf = 0.25 mm is about 5–50% higher than those for δf = 0.115 mm whereas the pressure drop for δf = 0.25 mm is about 5–20% higher. The unexpected difference in heat transfer coefficient subject to fin thickness is attributable to better interactions between the directed main flow and the swirled flow caused by the condensate droplet for δf = 0.25 mm. The maximum difference in heat transfer coefficients for N = 2 and Fp = 2.54 mm subject to the influence of fin thickness is reduced to about 20%, and there is no difference in heat transfer coefficient when the frontal velocity is above 3 m/s. For N  4 and Fp = 2.54 mm, the influence of fin thickness on the heat transfer coefficients diminishes considerably. This is because of the presence of tube row, and the unsteady/vortex shedding feature at the down stream of wavy channel. Based on the present test results, a correlation is proposed to describe the air-side performance for wavy fin configurations, the mean deviations of the proposed heat transfer and friction correlations are 7.9% and 7.7%, respectively.  相似文献   

12.
For applications such as cooling of electronic devices, it is a common practice to sandwich the thermoelectric module between an integrated chip and a heat exchanger, with the cold-side of the module attached to the chip. This configuration results thermal contact resistances in series between the chip, module, and heat exchanger. In this paper, an appraisal of thermal augmentation of thermoelectric module using nanofluid-based heat exchanger is presented. The system under consideration uses commercially available thermoelectric module, 27 nm Al2O3–H2O nanofluid, and a heat source to replicate the chip. The volume fraction of nanofluid is varied between 0% and 2%. At optimum input current conditions, experimental simulations were performed to measure the transient and steady-state thermal response of the module to imposed isoflux conditions. Data collected from the nanofluid-based exchanger is compared with that of deionized water.Results show that there exist a lag-time in thermal response between the module and the heat exchanger. This is attributed to thermal contact resistance between the two components. A comparison of nanofluid and deionized water data reveals that the temperature difference between the hot- and cold-side, ΔT = Th ? Tc  0, is almost zero for nanofluid whereas ΔT > 0 for water. When ΔT  0, the contribution of Fourier effect to the overall heating is approximately zero hence enhancing the module cooling capacity. Experimental evidence further shows that temperature gradient across the thermal paste that bonds the chip and heat exchanger is much lower for the nanofluid than for deionized water. Low temperature gradient results in low resistance to the flow of heat across the thermal paste. The average thermal contact resistance, R = ΔT/Q, is 0.18 and 0.12 °C/W, respectively for the deionized water and nanofluid. For the range of optimum current, 1.2 ? current ? 4.1 A, considered in this study, the COP ranges between 1.96 and 0.68.  相似文献   

13.
A systematic numerical investigation of heat transfer in turbulent channel flow over dimpled surface is conducted. Both symmetric (or spherical) and asymmetric dimple with different depth ratios (h/D) and skewness (Dx and Dz) are considered for a series of Reynolds numbers Re2H (based on bulk velocity and full channel height) between 4000 and 6000 while Prandtl number Pr is fixed at 0.7. It is found that the optimum dimple configuration for enhancing heat transfer measured in terms of the volume goodness factor is obtained for the case of asymmetric dimple with a depth ratio of h/D = 15% and stream-wise skewness of Dx = 15%. The heat transfer capacity in terms of Nusselt number is significantly increased, while the associated pressure loss is kept almost to the same level as the symmetric dimple with the same depth ratio. The present study also suggests that the heat transfer enhancement is closely related to ejection with counter-rotating flow, intensified secondary flow and vortex structures at the downstream rim of asymmetric dimple. All these findings suggest that a carefully designed asymmetric dimpled surface presents a viable means of enhancing heat transfer compared to the symmetric dimple.  相似文献   

14.
The two-phase heat transfer coefficient and pressure drop of HFC-134a during evaporation inside a smooth helically coiled concentric tube-in-tube heat exchanger are experimentally investigated. The test section is a 5.786-m long helically coiled tube with refrigerant flowing in the inner tube and heating water flowing in the annulus. The inner tube is made from copper tubing of 9.52 mm outer diameter and 7.2 mm inner diameter. The heat exchanger is fabricated by bending a straight copper tube into a spiral coil. The diameter of coil is 305 mm. The test run are done at average saturated evaporating temperatures ranging between 10 and 20 °C. The mass fluxes are between 400 and 800 kg m−2 s−1 and the heat fluxes are between 5 and 10 kW m−2. The inlet quality of the refrigerant in the test section is calculated using the temperature and pressure obtained from the experiment. The pressure drop across the test section is directly measured by a differential pressure transducer. The effects of heat flux, mass flux and, evaporation temperature on the heat transfer coefficients and pressure drop are also discussed. The results from the present experiment are compared with those obtained from the straight tube reported in the literature. New correlations for the convection heat transfer coefficient and pressure drop are proposed for practical applications.  相似文献   

15.
An experimental investigation of electrohydrodynamic (EHD) augmentation of heat transfer for in-tube condensation of flowing refrigerant HFC-134a has been performed in a horizontal, single-pass, counter-current heat exchanger with a rod electrode placed in the centre of the tube. The effects of varying the mass flux (55 kg/m2 s  G  263 kg/m2 s), inlet quality (0.2  xin  0.83) and the level of applied voltage (0 kV  V  8 kV) are examined. The heat transfer coefficient was enhanced by a factor up to 3.2 times for applied voltage of 8 kV. The pressure drop was increased by a factor 1.5 at the same conditions of the maximum heat transfer enhancement. The improved heat transfer performance and pressure drop penalty are due to flow regime transition from stratified flow to annular flow as has been deduced from the surface temperature profiles along the top and bottom surfaces of the tube.  相似文献   

16.
《Applied Thermal Engineering》2007,27(5-6):877-885
A theoretical model that predicts the thermal and fluidic characteristics of a micro cross-flow heat exchanger is developed in this study. The theoretical model is validated by comparing the theoretical solutions with the experimental data from the relative literature. This model describes the interactive effect between the effectiveness and pressure drop in the micro heat exchanger. The analytical results show that the average temperature of the hot and cold side flow significantly affects the heat transfer rate and the pressure drop at the same effectiveness. Different effectiveness has a great influence upon the heat transfer rate and pressure drop. When the micro heat exchanger material is changed from silicon to copper, the thermal conductivity changes from 148 to 400 W/m K. The heat exchanger efficiency is also similar. Therefore, the (1 1 0) orientation silicon based micro heat exchanger made using the MEMS fabrication process is feasible and efficient. Furthermore, the dimensions effect has a great influence upon the relationship between the heat transfer rate and pressure drop. Therefore, the methodology presented in this paper can be used to design a micro cross-flow heat exchanger.  相似文献   

17.
The turbulent heat transfer and flow resistance in an enhanced heat transfer tube, the DDIR tube, were studied experimentally and numerically. Water was used as the working fluid with Reynolds numbers between 15,000 and 60,000. The numerical simulations solved the three dimensional Reynolds-averaged Navier–Stokes equations with the standard k-ε model in the commercial CFD code, Fluent. The numerical results agree well with the experimental data, with the largest discrepancy of 10% for the Nusselt numbers and 15% for the friction factors. The heat transfer in the DDIR tube is enhanced 100  120% compared with a plain tube and the pressure drop is increased 170  250%. The heat transfer rate for the same pumping power is enhanced 30  50%. Visualization of the flow field shows that in addition to the front and rear vortices around the ribs, main vortices and induced vortices are also generated by the ribs in the DDIR tube. The rear vortex and the main vortex contribute much to the heat transfer enhancement in the DDIR tubes. Optimum DDIR tube parameters are proposed for heat transfer enhancement at the same pumping power.  相似文献   

18.
This study experimentally investigates the local heat transfer characteristics of a microscale confined impinging air jet on a heated plate. The experimental parameters included the Reynolds number (ReD = 1600–5600), the nozzle-to-plate spacing (H/D = 1–10), and the degree of confinement of the nozzle (DC/D = 3, 6, 9, 12, 24, 48). The degree of confinement of the nozzle is a novel parameter. A reduction in the heat transfer rate was found for nozzles whose DC/D values were 6, 9, 12, 24, and 48 as a result of the confinement effect at small nozzle-to-plate spacings. The confinement effect disappeared beyond H/D values of 2, 3, 4, 8, and 17 for DC/D values of 6, 9, 12, 24, and 48, respectively. Flow characteristics were investigated by measuring pressure distributions along the wall. Subatmospheric pressure, which is evidence of the confinement effect, was observed for the confined nozzles. Correlations of the stagnation and average Nusselt numbers are proposed on the basis of the experimental results. Finally, a contour map that depicts the ratio of the Nusselt numbers of the unconfined and confined jets is presented. The contour map confirms that the confined jets have a smaller Nusselt number than the unconfined jets whenever the degree of confinement of the nozzle is large and the nozzle-to-plate spacing is small.  相似文献   

19.
Heat transfer and pressure drop characteristics of an absorbent salt solution in a commercial plate heat exchanger serving as a solution sub-cooler in the high loop of triple-effect absorption refrigeration cycle was investigated. The main objectives of this research were to establish the correlation equations to predict the heat transfer and pressure drop and to analyze and optimize the operating parameters for use in the design of absorption systems.In order to conduct above studies, a single-pass cross-corrugated ALFA-LAVAL plate heat exchanger, Model PO1-VG, with capacity of 14,650 W (50,000 Btu/h) was used. In order to evaluate the performance, hot solution inlet temperatures from 55 °C (130 °F) to 77 °C (170 °F), and inlet temperature differences from 14 °C (25 °F) to 20 °C (35 °F) were used. The cold side of the heat exchanger was operated to match the equal heat capacity rate of hot side.Based on the empirical models proposed in the literature, a program was developed and experimental data were curve fitted. From the best-fitted curves, the power-law equations for heat transfer and pressure losses were established and the performance was evaluated.In the hot salt solution side, the Reynolds number was varied from 250 to 1100 and the resulting Nusselt number varied from 7.4 to 15.8. The measured overall heat transfer coefficient Uoverall varied from 970 W/m2 °C (170 Btu/h ft2 °F) to 2270 W/m2 °C (400 Btu/h ft2 °F) and the Fanning friction factor in the absorbent side of the heat exchanger varied from 5.7 to 7.6. The correlation equations developed to predict the heat transfer and friction factor perfectly agree with the experimental results. Those equations can be used to predict the performance of any solution with Prandtl numbers between 82 and 174, for heat exchangers with similar geometry.  相似文献   

20.
An experimental study of flow characteristics and heat transfer for jet impingement cooling of obstacles in the form of single spherical cavities is reported. The distributions of flow velocities between the nozzle and the obstacle, and also the fields of pressure and heat-transfer coefficients inside the cavity were measured. It is found that, at a value of depth the cavity generates the large-scale toroidal vortex, essentially influencing on the heat transfer. The cavity flow becomes unstable, exhibiting low-frequency pulsations of local heat fluxes. In the examined ranges of Reynolds numbers, Re = (1.2–5.8)104, and cavity depths (equal to or smaller than 0.5Dc) the local heat-transfer intensity in the cavity is lower than that on a flat obstacle; yet, this reduction is almost fully compensated by increased area of the heat-exchanging surface.  相似文献   