首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Classical control has serious limitations when faced with solids separation problems in the activated sludge process. Lack of knowledge about the mechanisms involved in the imbalance within the different microbiological communities implies that a general solution to these undesirable situations has not yet been provided. However, operators have to make decisions based on their experience and intuition to solve the problem (or at least to minimise the effects). The acquisition and registration of the knowledge learnt from each new experience can be decisive when solving similar problems in the future. Case-based reasoning (CBR) is an advanced technique for knowledge management in complex systems that uses past experiences to solve brand new situations. Previous simplified proposals in this field have exposed limitations, but this paper describes a new approach to CBR, considering the dynamics and the complexity of solids separation problems.  相似文献   

2.
The aims of the present work were to improve the biodegradation of the endocrine disrupting micro pollutant, bisphenol A (BPA), used as model compound in an activated sludge system and to underline the importance of modelling the system. Previous results have shown that BPA mainly is degraded under aerobic conditions. Therefore the aerobic phase time in the BioDenitro process of the activated sludge system was increased from 50% to 70%. The hypothesis was that this would improve the biodegradation of BPA. Both the influent and the effluent concentrations of BPA in the experiment dropped significantly after increasing the aerobic time. From simulations with a growth-based biological/physical/chemical process model it was concluded that although the simulated effluent concentration of BPA was independent of the influent concentration at steady-state, the observed drop in effluent concentrations probably was caused by either a larger specific biomass to influent BPA ratio, improved biodegradation related to the increased aerobic phase time, or a combination of the two. Thereby it was not possibly to determine if the increase in aerobic phase time improved the biodegradation of BPA. The work underlines the importance of combining experimental results with modelling when interpreting results from biodegradation experiments with fluctuating influent concentrations of micro pollutants.  相似文献   

3.
The activated sludge process can be modelled by ordinary and partial differential equations for the biological reactors and secondary settlers, respectively. Because of the complexity of such a system, simulation models are most often used to investigate them. However, simulation models cannot give general rules on how to control a complex nonlinear process. For a reduced-order model with only two components, soluble substrate and particulate biomass, general results on steady-state solutions have recently been obtained, such as existence, uniqueness and stability of solutions. The aim of the present paper is to utilize those results to formulate some implications of practical importance. In particular, strategies are described for the manual control of the effluent substrate concentration subject to the constraint that the settler is maintained in normal operation (with a sludge blanket in the thickening zone) in steady state. Such strategies contain how the two control parameters, the recycle and waste volumetric flow ratios, should be chosen for any (steady-state) values of the input variables.  相似文献   

4.
大型城市污水处理厂活性污泥法污泥膨胀防控对策   总被引:4,自引:0,他引:4  
详细解析了倒置A2/O工艺污泥膨胀发生前后的运行状况及活性污泥性状,通过水质数据对比和运行参数比较,探讨在大型城市污水处理厂建立污泥膨胀预警评价体系的可能性。利用工艺参数对典型工艺进行优化调控,提前预防污泥膨胀或在污泥膨胀初期进行防控。  相似文献   

5.
This paper analyses the performance of the anaerobic selector (A/O process) in a full-scale activated sludge process receiving mostly industrial sewage discharge (> 60%) in Singapore. In addition to the sludge settleability, enhanced biological phosphorus removal (EBPR) was studied. The sludge volume index (SVI) reduced from 200 to 80 ml g(-1) and foaming was suppressed significantly, indicating the effectiveness of the anaerobic selector in improving sludge settleability. The phosphorus removal efficiency was 66%, and 7.5 mg HAc-COD was consumed per mg PO4(3-) -P removed. In the anaerobic compartment, 31% of the SCOD and 73% of the acetic acid in the settled sewage were removed with PO4(3-) -P release of 14.1 mg PO4(3-)-P l(-1). The linear correlation between PO4(3-) -P release in the anaerobic compartment and PO4(3-) -P uptake in the aerobic compartment indicates that there is about 0.8 mg PO4(3-) -P release in the anaerobic compartment per mg PO34(3-) -P uptake in the aerobic compartment. The fates of volatile fatty acids (VFAs) and its short chain acids (SCAs) in the process were studied and discussed.  相似文献   

6.
循环式活性污泥法工程设计方法探讨   总被引:1,自引:0,他引:1  
许劲  孙俊贻 《给水排水》2007,33(2):34-38
分析了CASS与CAST工艺的异同点,指出SBR工艺可以模拟多种不同的连续处理工艺,而CAST可以根据连续流A2/O工艺的设计方法进行设计.通过定义(进水 反应)阶段占每个运行周期的比例(§),引入有效污泥龄与有效水力停留时间的概念,分析了CAST同步硝化反硝化功能对主反应区DO的控制要求及对好氧SRT的影响,推荐采用CAST处理城市污水时使用经验值θc厌∶θc缺∶θc好=1∶2∶17;强调系统生物量的衰减由系统总SRT决定,调整(§)即可调整总污泥龄,并影响总产率系数.最后,给出了设计步骤和计算实例.当采用平均日流量设计时,建议采用较长的运行周期(6 h),便于在峰值流量时增加周期数,以保持CAST运行的灵活性.  相似文献   

7.
The objective of this research was to include ozonation prior to an activated sludge treatment and investigate the effect on the nitrogen species, their fate and the consequences of this oxidation upon the biomass. Three parallel treatment systems were used: the base system, where feed went directly to the activated sludge reactor, and two others, where the influent was ozonated at two different dosages, 15 and 25 mg/L of influent, prior to the biological reactors. The results from the ozonation chamber show a high oxidation capacity of the entering ammonia and organic nitrogen, proportional to the ozone dose. The oxidation product was nitrate. No de-nitrification was expected because a high oxygen concentration (4 mg/L) was maintained in the reactors. The reactors receiving ozonated influent showed a lower assimilation of nitrogen by the biomass. The sludge nitrogen content resulted in 11, 9.3 and 7.4% dry-weight corresponding to no-ozone, low ozone and high ozone dosages, respectively. In spite of the lower ammonia available in the ozonated flows, the corresponding reactors showed a higher specific nitrification rate. The ozonated system also performed better in terms of chemical oxygen demand (COD) and biochemical oxygen demand (BOD5) removals, besides showing a higher true biomass yield coefficient.  相似文献   

8.
张辰  陈嫣  邹伟国 《给水排水》2007,33(6):37-40
对活性污泥法脱氮除磷工艺的设计方法进行探讨,提出以泥龄为主进行控制,采用活性污泥数学模型与经验方法相结合,并以COD为计量单位,对不同种类有机物进行分类.简述了不同有机物测定方法和设计过程.  相似文献   

9.
活性污泥数学模型在污水处理中的研究和应用进展   总被引:1,自引:0,他引:1  
阐述了国际水协会(IWA)推出的活性污泥1号(ASMI)、2号(ASM2)、2D号(ASM2D)、3号(ASM3)模型各自的机理和功能,介绍了ASM数学模型的改进及应用,最后分析讨论了模型研究与应用中存在的问题,并针对以上困难指出了模型在我国的发展前景。  相似文献   

10.
The behaviour of As(III), As(V), MMA(v) and DMA(v) in batch activated sludge process were investigated. Experiments were carried out by using aerobic and anoxic reactors with an initial As concentration of 100 microjg I(-1). Under aerobic condition, As(III) was oxidized to As(V) within 9 hours, some part of MMA(v) was methylated to DMA(v) and some other part was demethylated to As(III), which in turn was immediately oxidized to As(V). Under anoxic condition, As(V) was reduced to As(III) within the same time-course. No significant transformation occurred during experiments conducted with DMA(v). It was found that all reactions were biologically mediated. The overall As removal was low (< 20%) during the experiments. Although a relationship seems to exist between the sludge concentration and As removal, it is concluded, under the conditions of our study, that the activated sludge process cannot remove arsenicals efficiently. However, it can control their transformations well. Thus, if associated with an appropriate technology, the activated sludge can be used for As pre-oxidation to treat As contaminated wastewaters. Finally, care must be taken on possible presence of MMA(v) in the influent of any wastewater treatment plant as it can be easily oxidized by the activated sludge.  相似文献   

11.
In the paper three linear aeration controllers that can be easily implemented are presented and evaluated on the activated sludge process pilot plant. Controllers differ according to the information that is used about the process, which can be oxygen in the last aerobic reactor, ammonia in the last aerobic reactor and ammonia in the influent. The aeration controllers that are addressed are: oxygen cascade PI controller, ammonia cascade PI controller and ammonia feedforward-cascade PI controller. Experiments show that, in comparison with the oxygen cascade PI controller, the ammonia cascade PI controller allows better control of effluent ammonia and airflow savings of around 23%, while the ammonia feedforward-cascade PI controller gives the best reduction of ammonia peaks and can save up to 45% of the airflow.  相似文献   

12.
The paper describes and analyses the performance of anoxic selectors in upgrading activated sludge process in a municipal wastewater treatment plant under tropical climate, where poor sludge settleability is a problem due to elevated temperature. Site monitoring and laboratory experiment were conducted to study the denitrification, sludge settleability, kinetics, mass balance, pH and alkalinity variation in the system. The sludge settleability measured in Sludge Volume Index (SVI) was observed to improve with the increasing degree of denitrification in the anoxic selector. Under well-developed stable state, an average SVI value of 136 ml/g was achieved, which was significantly lower than the value of 250 ml/g before the application of anoxic selector. The specific reaction rates for denitrification and nitrification at 30 degrees C were 0.06 mg NO3-N/mg MLSS day and 0.08 mg NH4-N/mg MLSS day, respectively. The overall efficiencies of nitrification and denitrification were 86 percent and 55.4 percent, respectively, with an alkalinity recovery ratio of 15.4 percent. 32 percent of total COD removed was used up as electron donor in the denitrification process. However, due to absence of the internal Mixed Liquor Recirculation (MLR), a higher degree of denitrification occurred in the secondary sedimentation tank than in the anoxic zone. Issues for further studies are also discussed.  相似文献   

13.
The presence of a short circuit flow in a denitrifying activated sludge tank was identified and modelled. Tracer tests with pulse addition of lithium salt were used to investigate the hydraulics of the tank. The lithium concentration in the effluent was detected and residence time distribution (RTD) curves were generated. Hydraulic models based on completely stirred tank reactors (CSTRs) in series were generated from the RTD curves and the models were compared. The short circuit problem was successfully described using the Martin model, where the inflow is divided into two strands. Each strand was modelled as a number of CSTRs in series. At a normal flow the results of the model show that the tank has 12.8% dead volume, 85.8% main volume and 1.3% short circuiting volume. The inflow was divided into 91.9% entering the main volume and 8.1% entering the short circuiting volume. The mean velocity of the short circuiting stream was estimated to 0.4 m/s. At maximum flow the short circuiting stream was even larger and handled 24.3% of the flow. The short circuiting stream was identified in the upper part of the tank due to the position of the inlet and the outlet. The configuration of a tank including the use of baffles, the geometry of the inlet and mixer configuration should be considered carefully if short circuiting is to be avoided.  相似文献   

14.
A full-scale wastewater treatment plant where municipal and winery wastewaters were co-treated was studied for five years. The experimental results showed that suspended solids, COD, nitrogen and phosphorous were effectively removed both during the treatment of municipal wastewater and the cotreatment of municipal and winery wastewater. The sludge production increase from 4 tons to 5.5 tons per day during the harvesting and wine making period. In any case the specific sludge production was 0.2 kgMLVSS per kgCOD(removed) despite the organic loading increasing. About 70% of the COD was removed through respiration. Also the energy demand increased from 6,000 to 7,000 kWh per day. The estimated costs for the treatment of the winery wastewater was 0.2-0.3 Euros per m3 of treated wastewater. With reference to the process efficiency, the nitrogen removal was just 20%. The co-treatment of municipal and winery wastewater in conventional activated sludge processes can be a feasible solution for the treatment of these streams at relatively low costs.  相似文献   

15.
活性污泥工艺模型在计算机模拟中的建立与应用   总被引:3,自引:0,他引:3  
张发根  刘俊新  隋军 《给水排水》2006,32(9):94-100
利用计算机技术模拟活性污泥生化过程是分析研究污水处理工艺的有效手段之一,模拟的有效性取决于采用的动力学模型、工艺模型、沉淀模拟以及模拟计算中的数学分析方法。其中工艺模型反映了工艺特性,是真实工艺在模拟过程中的再现。根据水力学及运行特征,可将现有主要工艺分为单池间歇式、多池间歇式、单向连续式和交替连续式。运用ASM2D动力学模型,对某污水处理厂的UNITANK工艺进行模拟,结果表明,选择的动力学模型和工艺模型是合适的。  相似文献   

16.
Co-conditioning and dewatering of alum sludge and waste activated sludge.   总被引:4,自引:0,他引:4  
Co-conditioning and dewatering behaviors of alum sludge and waste activated sludge were investigated. Two different sludges were mixed at various ratios (2:1; 1:1; 1:2; 1:4) for study. Capillary suction time (CST) and specific resistance to filtration (SRF) were utilized to assess sludge dewaterability. Relatively speaking, waste activated sludge, though of higher solid content, was more difficult to be dewatered than alum sludge. It was found that sludge dewaterability and settlability became better with increasing fraction of alum sludge in the mixed sludge. Dosage required of the cationic polyelectrolyte (KP-201C) for dewatering was reduced as well. It is proposed that alum sludge acts as skeleton builder in the mixed sludge, and renders the mixed sludge more incompressible which is beneficial for sludge dewatering. Implications of the results of the study to the sludge management plan for Taipei City that generates both alum sludge and waste activated sludge at significant amount are also discussed. The current sludge treatment and disposal plan in Metropolitan Taipei could be made more cost-effective.  相似文献   

17.
活性污泥法的工艺参数控制(上)   总被引:1,自引:0,他引:1  
任周鸣 《给水排水》2007,33(11):45-50
活性污泥法的工艺控制是通过各工艺参数的控制来实现的,有些运行参数的控制要求还因污水处理要求和运行模式而异.只有正确理解各运行参数的涵义,了解不同工艺及相同工艺下不同运行模式的控制要求,才能通过科学管理控制好工艺运行状态,使处理系统高效低耗地运行.主要介绍了活性污泥法的工艺运行参数在实际应用中的理解和控制方法,阐述了一些书面定义和观点与实际应用时情况不相符的原因,提出了各控制参数与其他因素的关系及相关方面的一些综合分析思路,以期对运行管理有一定的参考作用.  相似文献   

18.
任周鸣 《给水排水》2007,33(12):44-49
2 污泥沉降比(SV30) 2.1 理论定义及实际应用上的理解 SV30是指曝气池混合液在量筒静止沉降30 min后污泥所占的百分体积.  相似文献   

19.
The paper describes the start up of a process for the production of polyhydroxyalkanoates (PHAs) from activated sludge. The excess sludge from a wastewater treatment plant was inoculated in a lab-scale sequencing batch reactor (SBR) to be enriched under aerobic conditions through intermittent feeding with a mixture of organic acids. Enriching of activated sludge was monitored through the measurement of polymer concentrations either in the mixed liquor or in the microbial biomass. The bacterial population dynamics during the SBR start up was followed through denaturing gradient gel electrophoresis and the main species present at the steady state were identified. All the measured parameters significantly changed in the SBR during first two weeks after the inoculum was seeded into the reactor, they then stabilized. At the steady state, the SBR produced 2.6 gVSSl(-1) d(-1), with a PHA content of 11% (on a COD basis). The enriched microbial biomass was then transferred into a batch reactor where the bacterial polymer content was increased through a new feeding. In the final batch stage, maximum storage rate and maximum polymer content in the biomass were 405 mgCOD gCOD(-1) h(-1) and 44% (on a COD basis), respectively. The PHA storage from the enriched microbial biomass was about 20 times faster and the PHA content was about 4 times higher than that of the inoculated activated sludge. Observations by fluorescence microscopy showed that the majority of microorganisms in the enriched biomass could be stored. Among the numerically most representative genera in the enriched biomass, Thauera, Candidatus Meganema perideroedes, and Flavobacterium were identified.  相似文献   

20.
基于LabVIEW的推流式活性污泥法动态仿真研究   总被引:1,自引:0,他引:1  
方芳  郭劲松  朱建军 《给水排水》2005,31(5):106-109
介绍了利用LabVIEW6.1及其数学子模板中一阶微分方程组的龙格库塔算法函数,根据活性污泥法1号数学模型一阶微分方程组的特征,开发出适用于推流式活性污泥法仿真系统的方法。应用该仿真系统模拟了重庆某污水处理厂的实际运行记录,结果表明仿真效果良好。该方法降低了软件的编程难度。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号