全文获取类型
收费全文 | 47篇 |
免费 | 2篇 |
专业分类
电工技术 | 3篇 |
化学工业 | 15篇 |
金属工艺 | 3篇 |
能源动力 | 1篇 |
轻工业 | 9篇 |
无线电 | 1篇 |
一般工业技术 | 8篇 |
冶金工业 | 6篇 |
自动化技术 | 3篇 |
出版年
2023年 | 2篇 |
2021年 | 3篇 |
2017年 | 1篇 |
2016年 | 1篇 |
2015年 | 1篇 |
2013年 | 2篇 |
2012年 | 1篇 |
2010年 | 3篇 |
2009年 | 2篇 |
2008年 | 3篇 |
2007年 | 4篇 |
2003年 | 1篇 |
2002年 | 4篇 |
1999年 | 1篇 |
1998年 | 3篇 |
1997年 | 2篇 |
1996年 | 3篇 |
1995年 | 2篇 |
1989年 | 1篇 |
1988年 | 1篇 |
1987年 | 1篇 |
1986年 | 1篇 |
1982年 | 1篇 |
1960年 | 4篇 |
1957年 | 1篇 |
排序方式: 共有49条查询结果,搜索用时 15 毫秒
1.
The formation of a crosshatched morphology during crystallization of an isotactic polypropylene with low crystallinity is studied in detail. Here, a lamella seems to grow through another nearly perpendicular lamella that was crystallized before. The crystallization was observed with in situ scanning force microscopy with a temporal resolution of 3 min per image. After crystallization the volume structure was imaged by nanotomography. A detailed scheme for the nucleation of branches is proposed. 相似文献
2.
3.
J. Gauger N. G. Holzknecht C. -A. Lackerbauer H. Sittek K. E. Fiedler R. Petsch M. Reiser 《Magma (New York, N.Y.)》1996,4(2):93-104
Current studies emphasize the use of array coils to decrease noise and increase the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). We applied Tl-weighted and T2-weighted standard nonbreathhold spin echo (SE) sequences and Tl-weighted FLASH, TurboFLASH, T2-weighted spin-echo time (TSE), and heavily T2-weighted half Fourier acquisition single-shot TSE (HASTE) sequences during breathhold for abdominal imaging in 15 normal volunteers. The breathhold scans were performed using both a standard coil and a circular polarized array coil. We analyzed the signal intensity (SI), SNR, and CNR of abdominal organs in all sequences. SNRs increased in all cases by an overall factor of 3 due to an 8% increase in overall Sis and a 50% decrease in noise when applying the array coil. Although the array-coil FLASH sequence performed at least as well as the respective SE sequence, the SNRs of the array-coil TurboFLASH, TSE breathhold, and HASTE sequences were generally lower. We conclude that array-coil imaging significantly improves fast imaging of the abdomen. 相似文献
4.
Phase errors that arise in phase-stepping interferometry are discussed. Investigations were performed by use of a Twyman-Green interferometer equipped with a compensation plate with a variable and servo-controlled tilt angle. With this instrument, phase-stepping errors can be reduced to a negligible level. There are, however, phase errors that are caused by camera nonlinearities. Two methods for minimizing these errors are presented. The first method is based on the simple idea that the interference intensity at the output of a two-beam interferometer has an exact cosine shape. The camera signals were monitored as a function of the tilt angle of the compensation plate, and the deviation from the cosine form was used to produce a correction. The second method is based on the idea that, under specific conditions, errors of an average of two phase measurements may compensate for each other. Numerical calculations were performed and give evidence of this hypothesis. Each method, the signal-correction and the averaging method, drastically reduces errors in evaluation of phases. The combination of both methods is a powerful tool that allows precise phase data to be obtained with an uncertainty, in the range lambda/2000 approximately 0.3 nm, that is caused mainly by signal noise. 相似文献
5.
6.
Tanja Stahl Caroline Rothe Manja U. B?hme Aloisa Kohl Nicolaus Kr?ger Boris Fehse 《International journal of molecular sciences》2016,17(9)
Accurate and sensitive determination of hematopoietic chimerism is a crucial diagnostic measure after allogeneic stem cell transplantation to monitor engraftment and potentially residual disease. Short tandem repeat (STR) amplification, the current “gold standard” for chimerism assessment facilitates reliable accuracy, but is hampered by its limited sensitivity (≥1%). Digital PCR (dPCR) has been shown to combine exact quantification and high reproducibility over a very wide measurement range with excellent sensitivity (routinely ≤0.1%) and thus represents a promising alternative to STR analysis. We here aimed at developing a whole panel of digital-PCR based assays for routine diagnostic. To this end, we tested suitability of 52 deletion/insertion polymorphisms (DIPs) for duplex analysis in combination with either a reference gene or a Y-chromosome specific PCR. Twenty-nine DIPs with high power of discrimination and good performance were identified, optimized and technically validated. We tested the newly established assays on retrospective patient samples that were in parallel also measured by STR amplification and found excellent correlation. Finally, a screening plate for initial genotyping with DIP-specific duplex dPCR assays was designed for convenient assay selection. In conclusion, we have established a comprehensive dPCR system for precise and high-sensitivity measurement of hematopoietic chimerism, which should be highly useful for clinical routine diagnostics. 相似文献
7.
Nicolaus Antonacopoulos 《Zeitschrift für Lebensmitteluntersuchung und -Forschung A》1960,113(2):113-116
Zusammenfassung Es wird eine verbesserte Apparatur zur quantitativen Abtrennung wasserdampfflüchtiger Stoffe beschrieben, bei der im Gegensatz zur bisher üblichen Arbeitsweise das Reaktionsgefäß in den Wasserdampfentwickler eingesetzt wird. Der Wasserdampf läßt sich dabei durch entsprechende Anordnung erst nach beginnendem Sieden in das Untersuchungsmaterial einleiten. Auf diese Weise lassen sich gleichmäßige Reaktionsbedingungen einhalten, die Destillationszeiten wesentlich verkürzen und die Ausbeuten quantitativer gestalten. 相似文献
8.
9.
The incorporation of conductive particles into a polymer matrix modifies fundamentally the electrical conductivity of the composite. The importance of carbon black structure on other mechanical and rheological properties is also well documented. Besides common techniques, like DBP-absorption and CDBP-absorption, void-volume, determined by the measurement of the volume of a given quantity of carbon black under a given pressure, has been considered as a more absolute technique. The present work considers the void-volume technique under a broader angle. The evolution of the volume of a given carbon black weight under increasing pressure as well as the evolution of the electrical resistivity is recorded and analysed. 相似文献
10.