With the forthcoming large-scale scientific experimental systems, we are looking for ways to construct an open, distributed architecture within the new and the existing automatic test systems. The new standard of Automatic Test Markup Language meets our demand for data exchange for this architecture through defining the test routines and resultant data in the XML format. This paper introduces the concept of ATML(Automatic Test Markup Language) and related standards, and the significance of these new standards for a distributed automatic test system. It also describes the implementation of ATML through the integration of this technology among the existing and new test systems. 相似文献
2.
3.
4.
激光聚变物理过程中会产生大量的电磁脉冲辐射,该电磁脉冲频谱宽,强度大,会对各诊断设备的正常运行以及精密测量造成不同程度的影响。为了研究该电磁脉冲的特性,为其产生机制研究和优化防护措施提供依据,对本次实验,在神光Ⅲ主机装置上进行。并在靶室内外搭建天线诊断系统,对电磁脉冲信号进行采集。本文讨论分析了靶室内小盘锥和矩形全向天线所采集的信号,并且两款天线所测时域信号值在特征峰位置吻合得相当好,所测频谱也最大范围的囊括了示波器的频域值,图像清晰的显示了激光与黑腔靶相互作用过程的4个电磁脉冲产生机制。 相似文献
5.
谢兴龙 朱键强 刘凤翘 管富义 黄关龙 戴亚平 杨镜新 李美荣 薛绍林 高奇 薛志玲 庄亦飞 韩爱妹 林尊琪 郑志坚 丁永坤 陈家斌 王世绩 顾援 王伟 王瑞荣 吴江 《中国激光》2003,30(8)
高功率激光物理国家实验室在国家高技术惯性约束聚变主题的支持下 ,经过不懈的努力又成功建成了一台基于钕玻璃放大器的 2 0TW超短脉冲系统 (SPS装置 )。其输出功率水平相当于实验室前年建成、国内规模最大的神光Ⅱ装置输出功率总和的两倍以上。新的SPS装置采用相干公司的Mira90 0作为振荡器 ,用改装在 1 0 5 3μm工作波长的再生放大器作为预放 ,经过 7级钕玻璃放大器对啁啾脉冲放大及扩束后 ,末级输出光束净口径 1 0 0mm ,光斑近场填充因子大于 5 0 %。经过主放大器放大的啁啾脉冲随后进入一对 4 0 0mm× 1 90mm的涂金光栅压缩器 ,经… 相似文献
6.
7.
在内爆物理实验中,多组激光脉冲在不同时刻与靶相互作用,产生若干瞬态物理过程。准确诊断这些激光与靶作用产生的瞬态过程之间的时序关系,对于成功获取实验状态的相关参数非常重要。提出了一种基于电磁辐射的内爆物理实验时序诊断方法,利用激光与金属靶相互作用时会产生强烈的电磁脉冲辐射,可获得不同激光与靶作用过程的时序关系,为判断和控制不同激光与靶作用过程之间的时序提供重要依据。在神光III主机大型激光装置上进行的实验测试表明,基于电磁辐射的内爆物理实验时序诊断方法可以准确确定预脉冲激光、主脉冲激光以及背光激光等与腔靶和平面背光靶之间作用的时序关系。该方法具有操作简单,测量精度高的优点,对于精确把握激光与靶相互作用过程的时间关系,提升实验精度有着重要意义。 相似文献
8.
X-ray Thomson scattering technique for diagnosing dense plasma was demonstrated on Shenguang-Π laser facility.Laser plasma x-ray source of titanium He-α lines (~4.75keV),generated by laser beam (1.5kJ/527nm/2ns) heated titanium thin foil,was used as x-ray probe beam.The x-ray probe was then scattered by cold CH foam column of 1g/cm3 density.The scattered radiation at 90 was diffracted by polyethylene terephthalate (PET) crystal and recorded on x-ray charge-coupled device.Well-defined scattering spectra were obtained with good signal to noise ratio. 相似文献
9.
10.
A streaked optical pyrometer (SOP) is developed and calibrated for the measurement of the temperature of shocked materials. In order to achieve a higher relative sensitivity, a onechannel scheme is adopted for the system. The system is calibrated with a shocked step-shaped aluminum sample in the SG-III prototype laser facility. The relation between the count number in the detection system and the sample temperature is thus obtained, which can be adopted to infer the temperature of any shocked materials in future experiments. 相似文献