In this article we consider the performance of the 3.84 Mcpstime-division duplex (TDD) mode of UTRA (Universal TerrestrialRadio Access) network. We emphasize two of the radio resourcemanagement algorithms, handover and uplink power control, whoserole in the overall system performance is studied extensively.First, a handover algorithm used in WCDMA (Wideband Code DivisionMultiple Access) standard is considered in a TDD-mode operation.This gives rise to a careful setting of different handoverparameters, and the evaluation of the effects to the systemperformance. Secondly, the specified uplink power controlalgorithm is considered. Since it is based on several user-mademeasurements which may involve both random and systematic errors acareful study about the suitability of the power control scheme iscarried out. 相似文献
Hybrid monolithic materials were prepared through polymerisation of 2-hydroxyethyl methacrylate (HEMA) mixed with zirconium alkoxides (Zr(OBun)4, Zr(OPrn)4 and Zr(OEt)4), modified by acetylacetonate groups. The molar ratio HEMA/Zr varied between 1 and 4. Thermo-Gravimetry coupled with Mass Spectroscopy (TG-MS) analyses, 13C MAS NMR and Dynamical Mechanical Thermal Analysys (DMTA) indicated the polymeric chains were interconnected by the inorganic component.The presence of zirconium alkoxides modified substantially the poly-HEMA properties. Glass transition temperature of hybrid materials derived from butoxy and propoxy was found in the range 50-80 °C, depending on the composition. The typical swelling of p-HEMA in the water, was suppressed by the presence of zirconium compounds. After immersion in distilled water, hybrid polymers showed an initial slight weight increase, followed by a small mass loss, which increases proportionally to the length of alkoxyl group (ethoxide(propoxide(butoxide) and reaches a constant value after about 40 days. The hybrids remained always rigid and transparent. Flexural modulus and strength of about 400-900 and 4-8 MPa were measured. 相似文献
SCG10 is a neuron-specific, membrane-associated protein that is highly concentrated in growth cones of developing neurons. Previous studies have suggested that it is a regulator of microtubule dynamics and that it may influence microtubule polymerization in growth cones. Here, we demonstrate that in vivo, SCG10 exists in both phosphorylated and unphosphorylated forms. By two-dimensional gel electrophoresis, two phosphoisoforms were detected in neonatal rat brain. Using in vitro phosphorylated recombinant protein, four phosphorylation sites were identified in the SCG10 sequence. Ser-50 and Ser-97 were the target sites for protein kinase A, Ser-62 and Ser-73 for mitogen-activated protein kinase and Ser-73 for cyclin-dependent kinase. We also show that overexpression of SCG10 induces a disruption of the microtubule network in COS-7 cells. By expressing different phosphorylation site mutants, we have dissected the roles of the individual phosphorylation sites in regulating its microtubule-destabilizing activity. We show that nonphosphorylatable mutants have increased activity, whereas mutants in which phosphorylation is mimicked by serine-to-aspartate substitutions have decreased activity. These data suggest that the microtubule-destabilizing activity of SCG10 is regulated by phosphorylation, and that SCG10 may link signal transduction of growth or guidance cues involving serine/threonine protein kinases to alterations of microtubule dynamics in the growth cone. 相似文献
OBJECTIVE: To evaluate the relationships between patient and physician pretreatment expectations of pain relief and subsequent pain relief reported by chronic pain patients immediately after treatment. DESIGN: Prospective study of consecutive patients undergoing a procedure in a pain clinic for treatment of chronic pain. Patients rated their current pain level and their expectation of pain relief immediately prior to undergoing a procedure (e.g., intravenous drug infusion, nerve block) for the treatment of chronic pain. Simultaneously and independently, the treating physician completed a similar questionnaire. At completion of the procedure, patients rated their current pain level and degree of pain relief. SETTING: University of Washington Multidisciplinary Pain Center procedure suite. PATIENTS: Forty-six consecutive chronic pain patients. INTERVENTION: Intravenous drug infusions and nerve blocks. OUTCOME MEASURES: Current pain and pain relief ratings. RESULTS: Patients' pain relief expectation ratings were not correlated significantly with their postprocedure pain relief ratings or pre-post procedure changes in pain ratings. However, a statistically significant correlation was found between physician expectations of pain relief and patient pain relief ratings and patient pre-post procedure changes in pain. CONCLUSIONS: The results of this study suggest that physicians are better predictors than are patients of patients responses to these procedures and/or that physicians may somehow subtly communicate their expectations to patients during the procedure, and these expectations then influence patient response. Patient pretreatment expectations may not always play a significant role in nonspecific treatment effects. 相似文献
OBJECTIVE: To estimate the frequency of perioperative morbidities in patients who underwent anesthesia and a surgical procedure with no preoperative laboratory testing. MATERIAL AND METHODS: We conducted an electronic database search of medical records of 56,119 patients who underwent surgical or diagnostic procedures and anesthesia at Mayo Clinic Rochester in 1994 and found 5,120 who had no laboratory tests done within 90 days before the procedure. From this group, we randomly selected 1,044 patients (87 from each month) to document the absence of preoperative tests, the presence of preexisting disease (by organ system), the type of anesthetic agent, and the outcomes and tests intraoperatively and postoperatively. RESULTS: The 1,044 patients ranged in age from 0 to 95 years (median age, 21). No deaths or major perioperative morbidities occurred (0.0%; exact 95% confidence interval, 0.00 to 0.35%). Although 10 patients underwent blood typing and screening for antibodies immediately preoperatively, no blood transfusions were necessary. Intraoperatively, 17 laboratory tests and 1 electrocardiogram were obtained, and 3 results were abnormal. Postoperatively, 42 blood tests and 2 electrocardiographic procedures were performed. Five of the 42 blood tests showed abnormal results (hemoglobin levels in 3, serum sodium in 1, and arterial blood gases in 1). One electrocardiogram showed normal findings, and the other revealed normal results except for premature ventricular contractions. No laboratory test done intraoperatively or postoperatively was found to change surgical or medical management substantially. One patient who had unanticipated blood loss during an outpatient procedure was admitted to the hospital for observation. CONCLUSION: All 1,044 patients, 97% of whom were relatively healthy, with no recent laboratory testing safely underwent anesthesia and an operation. We conclude that patients who have been assessed by history and physical examination and determined to have no preoperative indication for laboratory tests can safely undergo anesthesia and operation with tests obtained only as indicated intraoperatively and post-operatively. Current anesthetic and medical practices rapidly identify perioperative indications for laboratory evaluation as they arise. 相似文献
Summary The influence of draw ratio on macroscopic and crystallographic density of polyethylene with different initial morphologies, has been investigated by solid-state extrusion. An initial drop followed by an increase in macroscopic density as a function of draw ratio has been observed. Since precision X-ray measurements of unit cell parameters showed no variation of crystallographic density, it was concluded that plastic deformation of polyethylene upon drawing proceeds with a decrease of the degree of crystallinity. This was confirmed by differential scanning calorimetry. 相似文献
Inorganic–organic hybrid materials are attracting a strong scientific interest mainly for their outstanding inherent mechanical and thermal properties, which can be traced back to the intimate coupling of both inorganic and organic components. By carefully choosing the experimental parameters used for their synthesis, chemically and thermally stable acrylate-based hybrid material embedding the zirconium oxocluster Zr4O4(OMc)12, where OMcCH2C(CH3)C(O)O, can be deposited as UV-cured films on aluminium alloys.
In particular, the molar ratios between the oxocluster and the monomer, the polymerisation time, the amount of photo-initiator and the deposition conditions, by using an home-made spray-coating equipment, were optimised in order to obtain the best performing layers in terms of transparency and hardness to coat aluminium alloy (AA1050, AA6060 and AA2024) sheets. Furthermore, it was also evaluated whether the hybrid coatings behave as barrier to corrosion.
Several coated samples were prepared and characterised. Environmental scanning electronic microscopy (ESEM) and scratch test were used to investigate the morphology of the films and to evaluate their scratch resistance, respectively. Electrochemical impedance spectroscopy (EIS) was performed in order to evaluate if the coatings actually protect the metallic substrate from corrosion.
In order to measure shear storage modulus (G′) and loss modulus (G″) of the materials used for coatings, bulk samples were also obtained by UV-curing of the precursors solution. Dynamical mechanical thermal analysis (DMTA) was performed in shear mode on cured disks of both the hybrid materials and pristine polymer for comparison. The values of Tg were read off as the temperatures of peak of loss modulus. The length and mass of all the samples were measured before and after the DMTA analysis, so that the shrinkage of the materials in that temperature range was exactly evaluated. 相似文献
The present work is aimed to extend the knowledge of mechanical properties of sandwich structures used for marine applications
focusing on the possibility to increase the performances of such structures by adding a bonder at the skin/core interface.
Therefore, three sandwich structures that are utilised in different structural components of a yacht were realised by manual
lay-up. The mechanical characterisation was performed by flatwise compressive, edgewise compressive and three point flexural
tests. The tests execution has allowed both to determine the mechanical performances and to understand the fracture mechanisms
that take place when the bonder is added in the stacking sequence of the samples. 相似文献