首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   34篇
  免费   0篇
电工技术   2篇
化学工业   3篇
无线电   1篇
一般工业技术   14篇
冶金工业   12篇
自动化技术   2篇
  2018年   1篇
  2013年   1篇
  2011年   1篇
  2010年   1篇
  2008年   3篇
  2007年   1篇
  2005年   2篇
  2002年   1篇
  1998年   1篇
  1997年   1篇
  1996年   1篇
  1995年   2篇
  1994年   2篇
  1993年   1篇
  1991年   1篇
  1989年   2篇
  1987年   6篇
  1986年   2篇
  1985年   2篇
  1977年   1篇
  1976年   1篇
排序方式: 共有34条查询结果,搜索用时 0 毫秒
31.
32.
A prototype single-screen workstation with a 2,048 x 2,560-pixel high-brightness monitor, 0.11-second image display time, and simple ergonomic design was compared to a conventional horizontal film alternator in diagnostic interpretation of chest computed tomography (CT) studies. Four radiologists used either the workstation or film alternator in interpretation of studies obtained in 10 patients. A counterbalanced within-subject repeated measures experimental design was used. Response times were analyzed for both methods of interpretation. Grades of excellent, acceptable, and unacceptable were assigned by a blinded "grader" to reports of the radiologists. The average time needed for an interpretation at the workstation was 5.65 minutes. No interpretations were graded unacceptable. Retrospective power analysis showed that 16 observers rather than four would have been required to show that use of the workstation was faster than the alternator. With this 95% confidence interval, the workstation interpretation time is clinically equivalent to that with the alternator. These data show that this type of workstation has practical application in interpretation of CT, magnetic resonance imaging, and ultrasound studies.  相似文献   
33.
During recent assessment of aging in aluminum-to-rubber bonds on stored solid rocket motors, corrosion and minor insulator debonds were observed. A test was conducted to study the progressive effect of exposure to high humidity on the bondline; elevated temperature was used to accelerate the aging. In a parallel test, samples were held at elevated temperature in a dry atmosphere. The test results were compared with the analyses of corroded and noncorroded hardware samples. The predominant corrosion product detected at the bondlines was aluminum oxide/hydroxide. In general, there was a very good correlation between the Cl:Al atomic percent ratio calculated from X-ray photoelectron spectroscopy analysis of the ruptured bondline surfaces and the visual characterization of the extent of corrosion. The Cl:Al ratio, which represented the ratio of primer to corrosion product at the locus of failure, varied from 0.4 to 47. The implications for metal-to-rubber bond fabrication and storage are discussed.  相似文献   
34.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号