We investigate photophysical processes that take place in macromolecules of a fluorescent protein mRFP1 under UV excitation [when the energy transfer in a localized donor-acceptor (LDA) pair, which is presented in the molecules of the protein, becomes apparent]. We used a special approach based on the fluorescence laser spectroscopy technique. The energy transfer rates in LDA pairs and photophysical parameters of fluorophores (chromophores) of three spectral forms, which coexist in the ensemble of the macromolecules of this protein, were determined under pulse UV laser excitation. 相似文献
We present results of static and impact tension tests of as-received reinforcing steel specimens, specimens with weld joints
in their test portion, as well as specimens pretreated by high-density pulse current. As test results demonstrate, an increased
strain rate enhances strength, and the pulse current treatment greatly influences the strength and plasticity of a defect-containing
weld metal under static and impact tension.
Translated from Problemy Prochnosti, No. 3, pp. 89–96, May–June, 2009. 相似文献
Recently, the Russian government has ordered evaluation and reform of the basic research system. As a consequence, the number
of research staff at the Russian Academy of Sciences will be reduced by 20% by 2007. The basis for research evaluation and
institute budgeting will be bibliometric indicators. In view of these changes we look at the Russian publication output and
argue that
(1)
publication output and citedness have to be considered in relation to the level of expenditure on R&D
(2)
bibliometric indicators depend strongly on the database used (ISI’s databases are biased) and their interpretation can be
confusing; better coverage of Russian publications or a Russian Science Citation Index are needed. Also, research results
are communicated in more ways than paper publications.
(3)
policy makers have misused ISI statistics to demonstrate “a low level” of Russian R&D.
Our paper is a part of a project designed to trace R&D development in a transition economy and knowledge transfer from basic
research to innovation. Results of our project shed light on science policy and the social issues due to the indiscriminate
introduction of quantitative indicators. 相似文献
The effect of the modification of the polyvinyl alcohol (PVA) selective layer of thin film composite (TFC) membranes by aluminosilicate (Al2O3·SiO2) nanoparticles on the structure and pervaporation performance was studied. For the first time, PVA-Al2O3·SiO2/polyacrylonitrile (PAN) thin film nanocomposite (TFN) membranes for pervaporation separation of ethanol/water mixture were developed via the formation of the selective layer in dynamic mode. Selective layers of PVA/PAN and PVA-Al2O3·SiO2/PAN membranes were formed via filtration of PVA aqueous solutions or PVA-Al2O3·SiO2 aqueous dispersions through the ultrafiltration PAN membrane for 10 min at 0.3 MPa in dead-end mode. Average particle size and zeta potential of aluminosilicate nanoparticles in PVA aqueous solution were analyzed using the dynamic light scattering technique. Structure and surface properties of membranes were studied using scanning electron microscopy (SEM), atomic force microscopy (AFM) and water contact angle measurements. Membrane performance was investigated in pervaporation dehydration of ethanol/water mixtures in the broad concentration range. It was found that flux of TFN membranes decreased with addition of Al2O3·SiO2 nanoparticles into the selective layer due to the increase in selective layer thickness. However, ethanol/water separation factor of TFN membranes was found to be significantly higher compared to the reference TFC membrane in the whole range of studied ethanol/water feed mixtures with different concentrations, which is attributed to the increase in membrane hydrophilicity. It was found that developed PVA-Al2O3·SiO2/PAN TFN membranes were more stable in the dehydration of ethanol in the whole range of investigated concentrations as well as at different temperatures of the feed mixtures (25 °C, 35 °C, 50 °C) compared to the reference membrane which is due to the additional cross-linking of the selective layer by formation hydrogen and donor-acceptor bonds between aluminosilicate nanoparticles and PVA macromolecules. 相似文献
An ability of poorly differentiated cells of different genesis, including tumor stem-like cells (TSCs), to internalize extracellular double-stranded DNA (dsDNA) fragments was revealed in our studies. Using the models of Krebs-2 murine ascites carcinoma and EBV-induced human B-cell lymphoma culture, we demonstrated that dsDNA internalization into the cell consists of several mechanistically distinct phases. The primary contact with cell membrane factors is determined by electrostatic interactions. Firm contacts with cell envelope proteins are then formed, followed by internalization into the cell of the complex formed between the factor and the dsDNA probe bound to it. The key binding sites were found to be the heparin-binding domains, which are constituents of various cell surface proteins of TSCs—either the C1q domain, the collagen-binding domain, or domains of positively charged amino acids. These results imply that the interaction between extracellular dsDNA fragments and the cell, as well as their internalization, took place with the involvement of glycocalyx components (proteoglycans/glycoproteins (PGs/GPs) and glycosylphosphatidylinositol-anchored proteins (GPI-APs)) and the system of scavenger receptors (SRs), which are characteristic of TSCs and form functional clusters of cell surface proteins in TSCs. The key provisions of the concept characterizing the principle of organization of the “group-specific” cell surface factors of TSCs of various geneses were formulated. These factors belong to three protein clusters: GPs/PGs, GIP-APs, and SRs. For TSCs of different tumors, these clusters were found to be represented by different members with homotypic functions corresponding to the general function of the cluster to which they belong. 相似文献
Today’s multiple degree-of-freedom myoelectric prosthesis relies only on direct control by the processed electromyographic signal. However, it is difficult for the wearer to learn unnatural muscle contractions in order to wield more than three DoFs of the arm. This makes it almost impossible to use more complex prostheses with a larger number of actuators. Methods based on sensor–actuator loop and artificial intelligence may reduce cognitive load of the user by removing low level control, and an intelligent control system would make it needless to micromanage every action. For this purpose, sensor system for body segments motion capture was developed, as well as sensor system for prosthetic limb’s environment motion capture. Neural networks were designed to process data from the sensor systems. For the identification of the knee angle, orientation trackers were used. Neural network predictor of arm positions predicts the shoulder angle using the information about movement of the lower limb. In the case of the periodic/cyclic movements of the legs, such as walking, the control unit uses typical movement patterns of the healthy upper limb. Ultrasonic range sensors are used to create 3D map of objects in the environment around the arm. Neural network predictor of object positions predicts collisions. If the potential collisions are identified, the control unit stops arm movement. The new methods were verified by MATLAB and are designed as a part of assistive technology for disabled people and are to be understood as an original contribution to the investigation of new prosthesis control units and international debate on the design of new myoelectric prostheses.
The paper deals with the geometric and elastostatic calibration of robotic manipulator using partial pose measurements, which do not provide the end-effector orientation. The main attention is paid to the efficiency improvement of identification procedure. In contrast to previous works, the developed calibration technique is based on the direct measurements only. To improve the identification accuracy, it is proposed to use several reference points for each manipulator configuration. This allows avoiding the problem of non-homogeneity of the least-square objective, which arises in the classical identification technique with the full pose information (position and orientation). Its efficiency is confirmed by the comparison analysis, which deals with the accuracy evaluation of different identification strategies. The obtained theoretical results have been successfully applied to the geometric and elastostatic calibration of a serial industrial robot employed in a machining work cell for aerospace industry. 相似文献
A model is presented for deformation of porous materials (PM) which makes it possible to calculate the stressed-strained state (physically substantiated relationship) in structural elements of PM taking account of bulk compression and shear.Translated from Problemy Prochnosti, No. 6, pp. 38–43, June, 1990. 相似文献