An ice slurry generation system was developed using direct contact heat transfer between water and the coolant, Fluroinert FC-84. The location of the coolant nozzle is an important design consideration to avoid clogging due to freezing of water. An ice fraction of up to about 40 percent was obtained with the nozzle located at the bottom of the ice slurry tank and the jet directed upwards into the water. Two simplified model were developed to extract the heat transfer coefficient between the coolant drops and the water. The first model requires as input the average drop diameter and the residence time while the second model uses the measured drop diameter distribution. The estimated heat transfer coefficients are much smaller than those computed using single-sphere correlations. 相似文献
Home storage is the final step of the frozen foods distribution chain, and little is known on how it affects the products quality. The present research describes frozen green beans (Phaseolus vulgaris, L.) quality retention profile during the recommended ‘star marking’ system dates, at the storage temperatures of +5, −6, −12 and −18 °C (along 1, 4, 14 and 60 days, respectively).
The quality profile was assessed by a simulation system. Simulations were set by a response surface methodology to access the effect of different packaging materials (thermal conductivities and thickness), surface heat transfer coefficient, and refrigerator dynamics (effect of refrigeration cycles at the different storage temperatures) on the average retentions of Ascorbic Acid, total vitamin C, colour and flavour.
Green beans quality losses along frozen storage are significantly influenced by temperature, refrigerator dynamics and kinetic properties. Quality is also highly dependent on packaging materials thermal insulation (e.g. at temperatures above the melting point). Temperature cycles inside frozen chambers have a long term effect, and at the higher storage temperatures (e.g. T>−6 °C) are detrimental to frozen green beans quality after shorter periods. 相似文献
Critical heat fluxes (CHFs) were measured for two types of rectangular ducts containing horizontal flat plate heaters. One has the flat plate heater of 6 mm wide and 20 mm long located on the inner lower wall at 50 mm from the inlet. The other duct has two horizontal flat plates of 6 mm wide and 20 mm long on inner upper and lower walls at 50 mm from the inlet. The equation of CHF for the forced convection containing a new nondimensional-parameter m introduced in order to calculate cross-sectionally averaged liquid temperature at the center of the duct was derived based on two fluid model, ordinary convection theorem and experimental results. It was confirmed that this correlation can describe not only the author's data on the duct but also other worker's data for channels with different shapes and sizes. 相似文献
ZnS, ZnSe, and CdTe polycrystals are experimentally investigated. Mechanisms are treated which restrict the thermal conductivity in samples prepared by recrystallization pressing and by deposition from the vapor phase and subjected to additional strain. Anomalies are observed on the temperature dependences of the thermal resistance of investigated samples, which are due to the special features of their phonon spectra and to the variation of the contribution made by longitudinal and transverse phonon branches to the heat transfer in the Debye temperature region and higher. 相似文献
The paper gives the results of experimental investigations of the initial pressure gradient of bituminous oil and the time dependences of variation of the temperature in a formation model and of the well production rate in a microwave-frequency electromagnetic field. The effect of strong decay of the non-Newtonian properties of bituminous oil is revealed. The nonuniformity of temperature distribution over the formation thickness is demonstrated, which depends on the initial production rate of the well and on the duration of stimulation of the bottom-hole zone of formation. 相似文献
Time series solutions for spectral analysis in missing data problems use reconstruction of the missing data, or a maximum likelihood approach that analyzes only the available measured data. Maximum likelihood estimation yields the most accurate spectra. An approximate maximum likelihood algorithm is presented that uses only previous observations falling in a finite interval to compute the likelihood, instead of all previous observations. The resulting nonlinear estimation algorithm requires no user-provided initial solution, is suited for order selection, and can give very accurate spectra even if less than 10% of the data remains. 相似文献
The cost of order selection is defined as the loss in model quality due to selection. It is the difference between the quality of the best of all available candidate models that have been estimated from a finite sample of N observations and the quality of the model that is actually selected. The order selection criterion itself has an influence on the cost because of the penalty factor for each additionally selected parameter. Also, the number of competitive candidate models for the selection is important. The number of candidates is, of itself, small for the nested and hierarchical autoregressive/moving average (ARMA) models. However, intentionally reducing the number of selection candidates can be beneficial in combined ARMA(p,q) models, where two separate model orders are involved: the AR order p and the MA order q. The selection cost can be diminished by creating a nested sequence of ARMA(r,r-1) models. Moreover, not evaluating every combination (p,q) of the orders considerably reduces the required computation time. The disadvantage may be that the true ARMA(p,q) model is no longer among the nested candidate models. However, in finite samples, this disadvantage is largely compensated for by the reduction in the cost of order selection by considering fewer candidates. Thus, the quality of the selected model remains acceptable with only hierarchically nested ARMA(r,r-1) models as candidates. 相似文献
We present here the results of a study of the separation process in the extraction matrix of a novel high-intensity magnetic separator (HIMS). The matrix uses an ordered array of grooved plates (replacing conventional collectors, which are generally made of wires). Only experimental results are available for grooved plates in the literature, but here we propose a new theoretical approach. We report on the particles' behavior, the existence of a percolation phenomenon, and the filtration efficiency, in order to analyze and compare the performance of matrix structures (Lenoir's and Jones'). We discuss the causes of the percolation phenomenon and its effect on filtration efficiency. Correspondence between the theory and the experiments is good. We suggest appropriate uses of each matrix structure according to the property of the processed particles. 相似文献