全文获取类型
收费全文 | 134篇 |
免费 | 6篇 |
专业分类
电工技术 | 1篇 |
化学工业 | 40篇 |
金属工艺 | 5篇 |
机械仪表 | 9篇 |
建筑科学 | 4篇 |
能源动力 | 1篇 |
轻工业 | 8篇 |
石油天然气 | 1篇 |
无线电 | 3篇 |
一般工业技术 | 55篇 |
冶金工业 | 6篇 |
原子能技术 | 1篇 |
自动化技术 | 6篇 |
出版年
2023年 | 1篇 |
2021年 | 5篇 |
2020年 | 4篇 |
2019年 | 2篇 |
2018年 | 4篇 |
2017年 | 4篇 |
2016年 | 1篇 |
2015年 | 5篇 |
2014年 | 4篇 |
2013年 | 8篇 |
2012年 | 1篇 |
2011年 | 10篇 |
2010年 | 7篇 |
2009年 | 4篇 |
2008年 | 4篇 |
2007年 | 15篇 |
2006年 | 9篇 |
2005年 | 6篇 |
2004年 | 6篇 |
2003年 | 5篇 |
2002年 | 7篇 |
2001年 | 1篇 |
2000年 | 1篇 |
1999年 | 2篇 |
1998年 | 4篇 |
1997年 | 3篇 |
1995年 | 1篇 |
1994年 | 3篇 |
1992年 | 2篇 |
1991年 | 2篇 |
1990年 | 2篇 |
1985年 | 1篇 |
1982年 | 1篇 |
1981年 | 1篇 |
1980年 | 2篇 |
1973年 | 1篇 |
1957年 | 1篇 |
排序方式: 共有140条查询结果,搜索用时 15 毫秒
11.
Two criticality dosimetry systems were tested by Czech participants during the intercomparison held in Valduc, France, June 2002. The first consisted of the thermoluminescent detectors (TLDs) (Al-P glasses) and Si-diodes as passive neutron dosemeters. Second, it was studied to what extent the individual dosemeters used in the Czech routine personal dosimetry service can give a reliable estimation of criticality accident exposure. It was found that the first system furnishes quite reliable estimation of accidental doses. For routine individual dosimetry system, no important problems were encountered in the case of photon dosemeters (TLDs, film badge). For etched track detectors in contact with the 232Th or 235U-Al alloy, the track density saturation for the spark counting method limits the upper dose at approximately 1 Gy for neutrons with the energy >1 MeV. 相似文献
12.
We report a new application of affinity capture-elution electrospray mass spectrometry (ACESI-MS) to assay the enzymes phosphomannomutase (PMM) and phosphomannose isomerase (PMI), which when deficient cause congenital disorders of glycosylation CDG-type Ia and type Ib, respectively. The novel feature of this mass-spectrometry-based assay is that it allows one to distinguish and quantify enzymatic products that are isomeric with their substrates that are present simultaneously in complex mixtures, such as cultured human cell homogenates. This is achieved by coupled assays in which the PMM and PMI primary products are in vitro subjected to another enzymatic reaction with yeast transketolase that changes the mass of the products to be detected by mass spectrometry. The affinity purification procedure is fully automated, and the mass spectrometric analysis is multiplexed in a fashion that is suitable for high-throughput applications. 相似文献
13.
Masarik M Kizek R Kramer KJ Billova S Brazdova M Vacek J Bailey M Jelen F Howard JA 《Analytical chemistry》2003,75(11):2663-2669
The proteins streptavidin and avidin were electrochemically detected in solution by adsorptive transfer stripping square wave voltammetry (AdTS SWV) at a carbon paste electrode (CPE). AdTS SWV was used to quantify biotinylated oligonucleotides, DNA hybridizations, and avidin in extracts of transgenic avidin maize. The detection limits of denatured and native streptavidin were 6 pM and 120 nM, respectively. The results demonstrated that streptavidin/avidin AdTS SWV is a sensitive and specific method for quantifying DNA and proteins in biological samples such as foods and tissue extracts, including genetically modified crops (avidin maize) and other plants in neighboring fields. 相似文献
14.
Copolymer monoliths of diethyleneglycol dimethacrylate and 2-hydroxyethyl-acrylate were prepared by using the advantage of radiation initiated polymerization over the thermally initiated polymerization, namely, that it is sufficient to use only a monomer and a porogenic solvent and no initiator is needed. Besides, the reaction can take place at any desired temperature in a mold of suitable size and shape.The results showed that increase of the HEA content in the comonomer mixture (up to 18 vol%) resulted in monoliths with increased pore size and hydrophilic character. The specific surface area of these monoliths was in the order of 1 m2/g. The porous properties could be fine-tuned by changing the solvent.Flow rate measurements for several eluents indicated that these monoliths could be useful as chromatographic columns. This is illustrated by separation of several amino acids. 相似文献
15.
Jiri Pikula Hana Bandouchova Klara Hilscherova Veronika Paskova Jana Sedlackova Ondrej Adamovsky Zora Knotkova Jiri Machat Ladislav Novotny Frantisek Vitula 《The Science of the total environment》2010,408(21):4984-4992
Under environmental conditions, wild birds can be exposed to multiple stressors including natural toxins, anthropogenic pollutants and infectious agents at the same time.This experimental study was successful in testing the hypothesis that adverse effects of cyanotoxins, heavy metals and a non-pathogenic immunological challenge combine to enhance avian toxicity. Mortality occurred in combined exposures to naturally occurring cyanobacterial biomass and lead shots, lead shots and Newcastle vaccination as well as in single lead shot exposure. Mostly acute effects around day 10 were observed. On day 30 of exposure, there were no differences in the liver accumulation of lead in single and combined exposure groups. Interestingly, liver microcystin levels were elevated in birds co-exposed to cyanobacterial biomass together with lead or lead and the Newcastle virus. Significant differences in body weights between all Pb-exposed and Pb-non-exposed birds were found on days 10 and 20. Single exposure to cyanobacterial biomass resulted in hepatic vacuolar dystrophy, whereas co-exposure with lead led to more severe granular dystrophy. Haematological changes were associated with lead exposure, in particular. Biochemical analysis revealed a decrease in glucose and an increase in lactate dehydrogenase in single and combined cyanobacterial and lead exposures, which also showed a decreased antibody response to vaccination.The combined exposure of experimental birds to sub-lethal doses of individual stressors is ecologically realistic. It brings together new pieces of knowledge on avian health. In light of this study, investigators of wild bird die-offs should be circumspect when evaluating findings of low concentrations of contaminants that would not result in mortality on a separate basis. As such it has implications for wildlife biologists, veterinarians and conservationists of avian biodiversity. 相似文献
16.
Frantisek Rybnikar Martina Kaszonyiova Roman Cermak Veronika Habrova Martin Obadal 《应用聚合物科学杂志》2013,128(3):1665-1672
This study focuses on the structure, morphology, and properties of linear polyethylene (PE) profiles manufactured by continuous extrusion. High level of chain orientation was achieved using specific flow and processing conditions. An extrusion die with semihyperbolic convergency was used to generate high percentage of elongational flow and chain extension. Simultaneously, high extrusion pressure and relatively low melt temperature led to flow‐induced crystallization of PE extended chains. The structure of PE tapes consists of crystal aggregates with different level of orientation and crystallinity. © 2012 Wiley Periodicals, Inc. J. Appl. Polym. Sci., 2013 相似文献
17.
A novel approach to monodispersed porous polymer beads allowing accurate control over a broad range of pore size distribution has been developed. It involves the use of monodispersed template particles which are used as polymeric porogens in the suspension polymerization of monomers such as styrene and divinylbenzene. The size uniformity of the template particles is retained by the final porous beads. The porous properties of the final beads are determined in large part by the characteristics of the porogenic mixture such as its composition, the molecular weight of the polymeric porogen, as well as the relative amount of monomers, polymeric and low molecular weight porogens used. 相似文献
18.
19.
Wolfe BJ Blanchard S Sadilek M Scott CR Turecek F Gelb MH 《Analytical chemistry》2011,83(3):1152-1156
We have developed a tandem mass spectrometry based assay of iduronate-2-sulfatase (IdS) activity for the neonatal detection of mucopolysaccharidosis II (MPS-II, Hunter Syndrome). The assay uses a newly designed synthetic substrate (IdS-S) consisting of α-L-iduronate-2-sulfate, which is glycosidically conjugated to a coumarin and a linker containing a tert-butyloxycarbamido group. A short synthesis of the substrate has been developed that has the potential of being scaled to multigram quantities. Sulfate hydrolysis of IdS-S by IdS found within a 3 mm dried blood spot specifically produces a nonsulfated product (IdS-P) which is detected by electrospray tandem mass spectrometry and quantified using a deuterium-labeled internal standard, both carried out in positive ion mode. Analysis of DBS from 75 random human newborns showed IdS activities in the range of 4.8-16.2 (mean 9.1) μmol/(h L of blood), which were clearly distinguished from the activities measured for 14 MPS-II patients at 0.17-0.52 (mean 0.29) μmol/(h L of blood). The assay shows low blank activity, 0.15 ± 0.03 μmol/(h L of blood). The within-assay coefficient of variation (CV) was 3.1% while the interassay CV was 15%. 相似文献
20.
Summary A potentiometric titration method for the estimation of the configuration ( and peptide bonds, I and II) of poly (aspartic acid) prepared by thermal polycondensation is presented. Experimental results of the potentiometric titration of various samples differing in the molar fraction of I and II are confronted with the results of 13C NMR spectroscopy. Both methods lead to comparable results. 相似文献