Improved procedures for the determination of total dissolved phosphorus (TDP), particulate phosphorus (PP) and dissolved inorganic orthophosphate (DP) are described. Organic particulate material is solubilized in 5 n NaOH, and phosphorus compounds are oxidized and mineralized to orthophosphate by persulfate digestion. DP is determined by an improved automated molybdenum blue procedure that does not require sample pH adjustment or a correction for silicate interference in the 0–50 mg Si 1?1 range. The use of 36-position digestion racks allows 32 TDP or PP samples to be digested in ca. 1 and 4 h respectively. Detection limits in μg of phosphorus 1?1 are DP, 2; TDP, 5; and PP. 1. Waste water samples were analyzed for TDP and PP by the nitric acid-sulfuric acid procedure and by the proposed method. There was no significant difference between the two sets of data (P > 0.45). 相似文献
What are the effects of flame behavior of a number of fires burning in close proximity to one another? The results of measurements of burning rates, heat feedback, flame height, and flame trailing are reported for fires involving liquid pools. 相似文献
The purpose of this paper is to present a formulation of a curved thin-walled box beam finite element having a variable cross-section with at least one vertical axis of symmetry.
To allow for the effects of warping and distortion, three degrees of freedom have been included in the formulation. These degrees of freedom have been designated as the rate of change of twisting angle, the distortional angle of the cross-section, and the rate of change of distortional angle. The effect of shear lag has also been included.
The element may be used for the elastic analysis of a variety of thin-walled structures and in particular for the preliminary analysis of box bridge decks where a three-dimensional analysis may be unnecessary. The accuracy of the element has been demonstrated by comparison of the results obtained with known results from other methods for some examples. 相似文献
An improved phenol-hypochlorite method for determining ammonia in water using nitroprusside as catalyst has been investigated. Unlike other recently published methods, the method is simple (and sufficiently sensitive for low-level analyses) and does not require accurate time intervals between reagents, not expensive equipment. The method is well suited for routine use.
Beer's Law was obeyed over the whole ammonia range investigated. Reproducibility was 1·3 per cent with 10 μg N, and 5·7 per cent with 1 μg N. 相似文献
The destruction of the carcinogen benzo[a]pyrene (BaP) by light is well known; laboratory workers are routinely advised to cover fluorescent lamps with yellow filters while treating samples containing BaP. However until recently the mechanism of oxidation by sunlight and ozone had not been studied in detail. Concentrations of benzo[a]pyrene in urban air are in the range of 5–10 μg/1000 m3. Oxidant concentrations (predominantly in the form of ozone) are reported to be in the range of 0.01 ppm (22 μg per m3). Thus a sampling system with a filter paper would filter about 22,000 μg of ozone passing through and collect about 5 μg of BaP for analysis. The effect of interactions of such large ozone concentrations with BaP deposited on the filter paper is reported; data for the oxidation rates for benzo[a]pyrene coated on quartz surface and exposed to ozone or sunlight are presented. The oxidation products were analysed by thin-layer chromatography and highpressure liquid chromatography. From about eight products detected in these experiments, three have been identified as quinones based on UV-absorption spectrometry and mass spectrometry. Oxidation rates as high as 100% per hour of exposure are observed when less than 0.1 μg of BaP is coated inside the quartz tubes and exposed to ozone or sunlight. Oxidation rates for benzo[a]pyrene (using tritiated BaP) were determined for two types of experimental conditions. In the first set, tritiated BaP was spotted onto a glass fibre paper and sampling continued for 24 h; the loss of BaP was found to be 88%. In the second set tritiated BaP was spotted at intervals of one hour, for eight hours, while sampling is being carried out and the loss of BaP during the period was estimated to be 50%. 相似文献
The instrument was a byproduct of an undergraduate final year project on wind power which was carried out by the Department of Mechanical Engineering of the University of Liverpool.The windmill test site was on an exposed, rocky island where there was no history of weather recording but a long tradition of violent winds.Field experience during the winter months suggested that corrosion fatigue arising from wind buffeting and salt spray would rank equally with maximum wind pressure as criteria of failure and if modern materials, so convenient for forming aerodynamic surfaces, were to be used then limited life concepts would need to be considered. This called for more knowledge of wind variations at the test site. A complete wind spectrum taken on chart recording instruments would have been ideal but since such such refined devices were not available the instrument to be described was designed.The only wind measuring instrument which was available was a rotating cup anemometer. This supplied an alternating voltage proportional to its rotational speed. It also operated a gear driven microswitch which could give an integrated “miles of wind” reading on an electromagnetic counter.Briefly the e.m.f. generated by the anemometer (Fig. 1) was matched against a pre-set voltage corresponding to the required gust velocity. When this was exceeded an appropriate counter was operated. Only the rising e.m.f. was significant. The subsequent fall was ignored. Initially three stages were incorporated which reported the gusts rising through forty, fifty and sixty knots, respectively. These recorded on separate counters. All basic settings were based on pitot-static speed determinations in a wind tunnel. 相似文献
Batch biological treatment of log yard run-off reduced biochemical oxygen demand (BOD), chemical oxygen demand (COD) and tannin and lignin (TL) concentration by 99%, 80%, and 90%, respectively. Acute (Microtox) toxicity was decreased over treatment, from an initial EC50 of 1.83% to a value of 50.4% after 48 h of treatment. Kinetics of biodegradation were determined using respirometry and fitted using the Monod and Tessier model. For the Monod model the maximum substrate uptake rate, and Ks values determined were 0.0038 mg BOD/mgVSS min, and 1.4 mg/L, respectively. The efficacy of ozone as a pre- and post- biological treatment stage was also assessed. During ozone pretreatment, TL concentration and acute toxicity were rapidly reduced by 70% and 71%, respectively. Pre-ozonation reduced BOD and COD concentration by < 10%, however a larger fraction of residual COD was non biodegradable after ozonation. Biologically treated effluent was subjected to ozonation to determine whether further improvements in effluent quality could be achieved. A reduction in COD and TL concentration was observed during ozonation, however no further improvement in toxicity was observed. Ozonation increased BOD by 38%, due to conversion of COD to BOD. 相似文献
In this paper, improvement of bond strength for epoxy-coated rebars is studied. Although the epoxy-coated rebar is well accepted as an alternative corrosion prevention method in engineering practice, it still suffers from its poor bond performance, which requires modification of design parameters such as development length and splice length. Following our previous study [Proceedings of the Third Structure Engineering Conference (1996) 651–659], it is proposed to mix the river sand in the epoxy to improve the bond strength of epoxy-coated rebar. Specimens of several sizes of river sand and sand/epoxy weight ratios were studied. The single-rebar pullout test was performed to examine the bond strength. The open circuit potential method and the linear DC polarization method were conducted for corrosion rate measurements to ensure for keeping the merit of epoxy-coated rebar, i.e. the ability of corrosion. Experimental results show that the proposed method is very promising. 相似文献