全文获取类型
收费全文 | 983篇 |
免费 | 0篇 |
专业分类
电工技术 | 1篇 |
化学工业 | 1篇 |
机械仪表 | 1篇 |
轻工业 | 1篇 |
冶金工业 | 979篇 |
出版年
2010年 | 1篇 |
2008年 | 1篇 |
2004年 | 1篇 |
2003年 | 4篇 |
1999年 | 31篇 |
1998年 | 281篇 |
1997年 | 160篇 |
1996年 | 112篇 |
1995年 | 77篇 |
1994年 | 47篇 |
1993年 | 52篇 |
1992年 | 9篇 |
1991年 | 21篇 |
1990年 | 18篇 |
1989年 | 20篇 |
1988年 | 21篇 |
1987年 | 15篇 |
1986年 | 20篇 |
1985年 | 11篇 |
1982年 | 9篇 |
1981年 | 3篇 |
1980年 | 9篇 |
1979年 | 1篇 |
1978年 | 3篇 |
1977年 | 12篇 |
1976年 | 40篇 |
1975年 | 2篇 |
1964年 | 1篇 |
1955年 | 1篇 |
排序方式: 共有983条查询结果,搜索用时 9 毫秒
41.
KW Neff KJ Lehmann G Weisser S Dénk M Georgi 《Canadian Metallurgical Quarterly》1998,38(12):1060-1068
PURPOSE: To evaluate the suitability of ultrafast electron-beam tomography (EBT) for the investigation of abdominal aortic aneurysms using CTA. METHODS: Thirty-one patients with suspected abdominal aortic aneurysm were investigated with EBT using an Evolution XP scanner (Siemens, Erlangen) with the newest software version 12.34 with continuous volume scanning of 140 images in 17 s. Collimation was 3 mm, table increment 4 mm with overlapping image reconstruction every 2 mm, exposure time 200 ms (124 mAs), resulting in a scan-range of 28 cm. A quantity of 80 ml contrast material was administered (flow 4 ml/s). Visualization of the abdominal aorta and its branches was performed with MIPs and shaded surface display. Evaluation of image quality was based on a four-step classification scale (1 = good, 4 = insufficient) for the demonstration of the abdominal aorta and the visceral, renal and iliac arteries. RESULTS: All EBT examinations demonstrated high and homogeneous density values along the whole vessel course with a mean density value of 258.7 +/- 47.3 HU for the abdominal aorta and the iliac arteries. Quality evaluation for the vessel demonstration showed mean values between 1.22 and 1.57 for the abdominal aorta and the visceral, renal and iliac arteries. CONCLUSIONS: EBT with 140 slices and slice reconstruction every 2 mm offers a high z-axis resolution resulting in high-quality CT angiographies of the whole abdominal aorta and its branches. 相似文献
42.
Gerbils learned to approach a spatial-olfactory stimulus that signaled access to their pairmate. Experiments 1 and 3 used a discrimination procedure in which 1 conditioned stimulus (the CS+) was presented immediately before access to the pairmate and another (the CS-) was presented alone. Both male and female gerbils came to approach the CS+ sooner than the CS- and spent more time near the CS+ than the CS-. Discrimination learning was facilitated by making the CS+ and CS- spatially distinct (Experiment 3). Learning also was demonstrated in male gerbils, using a between-subjects design with a single CS. Pairing the CS with the opportunity for social interaction resulted in greater approach to the CS within 10 trials than presenting the CS and social opportunity in an unpaired fashion (Experiment 2). These findings demonstrate social-affiliative learning in the Mongolian gerbil. Similarities and differences between these findings and sexual conditioning effects in other species are discussed. 相似文献
43.
SJ Victor DM Brown EM Horwitz AA Martinez VR Kini JE Pettinga KW Shaheen P Benitez PY Chen FA Vicini 《Canadian Metallurgical Quarterly》1998,82(7):1303-1309
BACKGROUND: Analyses were performed to determine local control and cosmetic outcome of breast carcinoma patients with prosthetically augmented or reconstructed breasts who had received radiation therapy (RT). METHODS: Twenty-one newly diagnosed breast carcinoma patients with prosthetically augmented or reconstructed breasts were treated with external beam RT. All patients received whole breast RT (median dose, 50.4 gray [Gy]) and 19 were boosted to a median dose of 60.4 Gy. A median dose of 50.4 Gy was delivered to the regional lymph nodes in 12 patients. Tissue equivalent bolus material was used in six patients. Seventeen patients received adjuvant systemic therapy. Cosmetic results were evaluated at 3-6-month intervals. RESULTS: With a median follow-up of 32 months, good/excellent cosmetic results were observed in 71% of patients (100% in those with augmented breasts and 54% in those with reconstructed breasts). Four patients (19%) with fair/poor cosmetic outcomes required implant removal and/or revision. Multiple clinical and treatment-related factors were analyzed for their impact on cosmetic outcome. A worsened cosmetic result was observed with increasing stage (P = 0.076), breast reconstruction (vs. augmentation) (P = 0.030), and bolus application (P = 0.016). All patients with fair/poor cosmetic outcomes had time intervals from implant insertion to RT ranging from 53-213 days. Two patients developed an isolated local recurrence within the augmented breast. CONCLUSIONS: Patients with prosthetically augmented breasts can undergo RT and expect good/excellent cosmetic results. Patients with reconstructed breasts are at a significantly greater risk for cosmetic failure. This risk may be related to the higher percentage of patients with advanced disease, those who received bolus application, and those who received earlier delivery of RT (after the cosmetic procedure) in reconstructed breasts. 相似文献
44.
KW Spencer 《Canadian Metallurgical Quarterly》1996,16(3):147-155
The preferred method for breast reconstruction is the simplest type that can meet the patient's needs and expectations (Bostwick, 1989). Several breast reconstruction procedures are presented in this issue. In this article, only breast reconstruction using the latissimus dorsi flap is discussed. 相似文献
45.
46.
47.
G Papanicolaou KW Beach RE Zierler DE Strandness 《Canadian Metallurgical Quarterly》1995,9(6):554-560
The relationship between the measured arm-ankle pressure difference (AAPD), or the ankle/arm index (AAI), and the focal peak systolic velocity (PSV) at stenotic sites of infrainguinal vein grafts has not been determined. We attempted to relate these two parameters. We used Doppler systolic pressures and duplex ultrasonography to study 35 infrainguinal vein bypass grafts followed in a surveillance protocol. The following graft groups were identified: grafts in nondiabetic patients (n = 26), grafts in diabetic patients (n = 9), nonrevised stenotic grafts (n = 14), revised stenotic grafts (n = 14), and normal grafts (n = 7). AAPD and AAI were measured in both lower extremities. Pressure gradients across graft stenoses were indirectly estimated using the modified Bernoulli equation (delta P =4V2). Measured AAPDs and estimated pressure gradients showed moderate correlation in nondiabetic (r = 0.58) and diabetic (r = 0.63) patients. Correlation was fair (r = 0.3) prior to graft revision. There was no correlation (r = 0.1) in the nonrevised stenotic grafts. For individual patients with stenotic grafts who were followed in consecutive visits, the correlation varied from none to good (r range 0.01 to 0.71). We conclude that there is a lack of consistent correlation between the measured AAPD, or AAI, and the estimated stenotic graft pressure gradient. This finding illustrates the limitation of the AAI as a monitoring test to predict failure of stenotic infrainguinal vein grafts. 相似文献
48.
Maternal lymphocyte reactivity to human trophoblast antigens was studied in placentas of gestational ages 8 to 14 weeks and 32 to 34 weeks, respectively. Significant trophoblast lysis became apparent after 24 hours' incubation in the latter case compared with a time lag of 72 hours in the terminated gestations. Maternal cellular immunity, therefore, was not detected during the first 3 1/2 months of pregnancy, but was detectable by the time of parturition. The possible significance is discussed with respect to the antigenic stimulus and survival of the fetal allograft. 相似文献
49.
Saccharomyces cerevisiae telomeres consist of a continuous 325 +/- 75-bp tract of the heterogeneous repeat TG1-3 which contains irregularly spaced, high-affinity sites for the protein Rap1p. Yeast cells monitor or count the number of telomeric Rap1p molecules in a negative feedback mechanism which modulates telomere length. To investigate the mechanism by which Rap1p molecules are counted, the continuous telomeric TG1-3 sequences were divided into internal TG1-3 sequences and a terminal tract separated by nontelomeric spacers of different lengths. While all of the internal sequences were counted as part of the terminal tract across a 38-bp spacer, a 138-bp disruption completely prevented the internal TG1-3 sequences from being considered part of the telomere and defined the terminal tract as a discrete entity separate from the subtelomeric sequences. We also used regularly spaced arrays of six Rap1p sites internal to the terminal TG1-3 repeats to show that each Rap1p molecule was counted as about 19 bp of TG1-3 in vivo and that cells could count Rap1p molecules with different spacings between tandem sites. As previous in vitro experiments had shown that telomeric Rap1p sites occur about once every 18 bp, all Rap1p molecules at the junction of telomeric and nontelomeric chromatin (the telomere-nontelomere junction) must participate in telomere length measurement. The conserved arrangement of these six Rap1p molecules at the telomere-nontelomere junction in independent transformants also caused the elongated TG1-3 tracts to be maintained at nearly identical lengths, showing that sequences at the telomere-nontelomere junction had an effect on length regulation. These results can be explained by a model in which telomeres beyond a threshold length form a folded structure that links the chromosome terminus to the telomere-nontelomere junction and prevents telomere elongation. 相似文献
50.