Musculoskeletal disorders are more common among women than among men. When comparing the difference between men and women in the prevalence of musculoskeletal disorders, methodological problems arise as men and women seldom perform the same type of activities, neither at work nor at home.
The main objective of this cross-sectional case study was to compare work technique and self-reported musculoskeletal symptoms between men and women performing the same type of work tasks within a metal industry. Other factors, such as leisure activities, were also taken into consideration. Three data collection methods were used; questionnaire, interviews and systematic observations. The results from the observations revealed that women worked more frequently and during longer times with their hands above shoulder height than men. Working with hands above shoulder height is considered a risk factor for neck and shoulder disorders according to previous studies. Workplace design factors were probably a reason for differences in working technique between men and women. A higher proportion of women than men reported shoulder symptoms. Women spent more time on household activities than men, which indicates a higher total workload in paid and unpaid work. 相似文献
Simple and comprehensive two-dimensional (2D)-HPLC was studied in a reversed-phase mode using monolithic silica columns for second-dimension (2nd-D) separation. Every fraction from the first column, 15 cm long (4.6-mm i.d.), packed with fluoroalkylsilyl-bonded (FR) silica particles, was subjected to the separation in the 2nd-D using one or two octadecylsilylated (C(18)) monolithic silica columns (4.6-mm i.d., 3 cm). Monolithic silica columns in the 2nd-D were eluted at a flow rate of up to 10 mL/min with separation time of 30 s that meets the fractionation every 15-30 s at the first dimension (1st-D) operated at a flow rate of 0.4-0.8 mL/min. Three cases were studied. (1) In the simplest scheme of 2D-HPLC, effluent of the 1st-D was directly loaded into an injector loop of 2nd-D HPLC for 28 s, and 2 s was allowed for injection. (2) Two six-port valves each having a sample loop were used to hold the effluent of the 1st-D alternately for 30 s for one 2nd-D column to effect comprehensive 2D-HPLC without the loss of 1st-D effluent. (3) Two monolithic silica columns were used for 2nd-D by using a switching valve and two sets of 2nd-D chromatographs separating each fraction of the 1st-D effluent with the two 2nd-D columns alternately. In this case, two columns of the same stationary phase (C(18)) or different phases, C(18) and (pentabromobenzyloxy)propylsilyl-bonded (PBB), could be employed at the 2nd-D, although the latter needed two complementary runs. The systems produced peak capacity of approximately 1000 in approximately 60 min in cases 1 and 2 and in approximately 30 min in case 3. The three stationary phases, FR, C(18), and PBB, showed widely different selectivity from each other, making 2D separations possible. The simple and comprehensive 2D-HPLC utilizes the stability and high efficiency at high linear velocities of monolithic silica columns. 相似文献
The samples are digested in nitric acid and evaporated to near dryness. Hydrogen peroxide is then added for complete oxidation of fat residues. Determination of metals is performed by flameless AAS with graphite furnace and results evaluated by the method of standard addition. The method is suitable for the determination of some non-volatile metals in fish livers in which the amount of available sample is limited; Pb, Cd, Cu and Zn have been determined in such samples. 相似文献
In the course of miniaturization of electronic and microfluidic devices, reliable predictions of the stability of ultrathin films have a strategic role for design purposes. Consequently, efficient computational techniques that allow for a direct comparison with experiment become increasingly important. Here we demonstrate, for the first time, that the full complex spatial and temporal evolution of the rupture of ultrathin films can be modelled in quantitative agreement with experiment. We accomplish this by combining highly controlled experiments on different film-rupture patterns with computer simulations using novel numerical schemes for thin-film equations. For the quantitative comparison of the pattern evolution in both experiment and simulation we introduce a novel pattern analysis method based on Minkowski measures. Our results are fundamental for the development of efficient tools capable of describing essential aspects of thin-film flow in technical systems. 相似文献
There is growing interest in complicated grief reactions as a possible new diagnostic category for inclusion in the Diagnostic and Statistical Manual of Mental Disorders. However, no research has yet shown that complicated grief has incremental validity (i.e., predicts unique variance in functioning). The authors addressed this issue in 2 studies by comparing grief, depression, and posttraumatic stress disorder (PTSD) symptoms with different measures of functioning (interviewer ratings, friend ratings, self-report, and autonomic arousal). The 1st study (N = 73) used longitudinal data collected at 4 and 18 months postloss, and the 2nd study (N = 447) used cross-sectional data collected 2.5-3.5 years postloss. With depression and PTSD controlled, grief emerged as a unique predictor of functioning, both cross-sectionally and prospectively. The findings provide convergent support for the incremental validity of complicated grief as an independent marker of bereavement-related psychopathology. (PsycINFO Database Record (c) 2010 APA, all rights reserved) 相似文献
Videogames are increasingly being used as instructional tools within education, workforce, and military contexts. Yet, additional research is needed to better understand what (and how) videogame-based training design attributes impact trainee performance in this type of training context. Goals/goal-setting and performance feedback represent two such important game design attributes. Goal-setting theory suggests that moderately difficult goals produce modest goal-performance discrepancies, which result in enhanced performance. Yet, goal-performance discrepancies are not universally beneficial. This study investigates the performance consequences of trainees setting an unrealistically difficult goal early in videogame-based training, and the mechanisms underlying this relationship. Data from 387 trainees completing a videogame-based training program demonstrated that an initial unrealistic goal, and subsequently a large goal-performance discrepancy, negatively impacts subsequent training performance. Self-regulation was examined as a mediator of this relationship; yet, was not supported, as goal-performance discrepancy failed to predict self-regulation. However, goal-performance discrepancy and videogame self-efficacy were found to interact in predicting trainees’ self-regulation, suggesting more complex underlying mechanisms. This study also demonstrated that providing trainees with simple goal-setting advisement can facilitate realistic goal-setting. These findings highlight the important role of realistic goal-setting in enhancing videogame-based training effectiveness. 相似文献
A fast and simple analytical procedure, based on capillary zone electrophoresis (CZE), for separation of underivatized low molecular weight lignin-derived sulphonates has been developed. Optimal CZE-operatipn conditions for the separation and detection of several lignin-derived sulphonic acids was found when using a low pH (pH 1.7) phosphate buffer system, an applied voltage of 20 kV and UV-detection at the anode-side. At these conditions the electroosmotic flow is negligible and the analytes are transported through the capillary column by electromigration. The sulphonation and subsequent degradation of the lignin-model compound 1-(4-hydroxy-3-methoxyphenyl)-2-O-(2-methoxyphenyl)-glycerol has been studied by CZE-analysis of aliquots taken from a sulphite reaction mixture No sample pretreatment was needed before analyzing the sulphite reaction mixture with CZE. The method has also been found to be useful for detection of sulphonic acids in samples from sulphite cooking. Crude extracts of a sulphite cooking liquor could be directly analysed by using the technique developed. Based on migration time data and comparison with an authentic sample, 1-(4-hydroxy-3-meth6xyphenyl)-prop-2-ene-1-sulphonate was identified as one of the sulphonic acids present in the sulphite cooking liquor. 相似文献