The authors discuss the testing of periodic materials and structures via noise spectroscopy as an alternative to frequency sweep spectral analyzers, and the presented procedure employs the various advantages offered by a wide spectrum signal a Generally, noise spectroscopy tests are carried out to verify the behaviour of the response of periodic structures, and the related objective consists in recording the properties of microscopic structures in natural and artificial materials. The aim is to propose and verify a high-precision metrological method utilizable for the investigation of structures and materials in the frequency range between 100 MHz and 10 GHz; this paper therefore characterizes the design of a suitable measuring technique based on noise spectroscopy. In this context, the applied equipment is also shown to complement the underlying theoretical analysis. 相似文献
Relatively recently it has become apparent that providing human kind with a better healthcare requires personalized, predictive and integrative medicine, for which the building of virtual physiological human (VPH) framework accessible via virtual patient avatar is necessary. Real‐time modelling and visual exploration of such a complex avatar is a challenging task. In this paper, we propose a real‐time method for automatic modelling of an arbitrarily large number of muscle fibres in the volume of a muscle represented by its surface mesh. The method is based on an iterative morphing of predefined fibres template into the muscle volume exploiting harmonic scalar field computed on the surface of muscle. Experiments with muscles of thighs and pelvis show that the method produces realistic shapes of fibres. Our sequential VTK‐based C++ implementation is capable of producing 64 fine fibres within a muscle of 10K triangles in less than 170 ms on commodity hardware making the method suitable for VPH purposes as well as for interactive educational medical software. 相似文献
We study a first-order phase transition between superfluid and Mott insulator phases in binary Bose mixtures loaded into a hypercubic optical lattice. The system is described by a two-component Bose-Hubbard model. Considering the difference between the two kinds of bosons in the intra-component interaction strength, we discuss the metastability of the system and the hysteresis associated with the first-order superfluid-Mott insulator transition. It is found that the sweeping of hopping amplitude induces a conventional hysteresis-loop behavior. We also find an anomalous hysteresis behavior when the chemical potential is varied. In the anomalous hysteresis, the phase transition occurs in a unidirectional way and a hysteresis loop does not form. 相似文献
This paper presents the adhesive strength of FeCr and FeCoCr coatings produced by electric arc thermal spray process on carbon steel plates. Carbon steels are not resistant to corrosion and several methods are used in surface engineering to protect them from aggressive environments such as the marine one. The main objective of this work is the evaluation of the mechanical and metallurgical properties of coatings produced by thermal spray on carbon steel. Five chemical compositions were tested in order to give a large panel of possibility. Coatings were characterized by several methods to result in a screening of performance. The physical properties of coatings were also evaluated by adhesion quantification, using pull-off test, and microhardness measurement. The assessment of microstructural morphology by X-ray diffraction (XRD) and scanning electron microscopy (SEM) was made. The open circuit potential was monitored to evaluate the corrosion tendency. SEM results showed uniformity in the deposited layer and low amount of oxide and porosity. The adhesive strength of FeCoCr alloy coatings was higher than other coating conditions. In the immersion test, all sealed conditions presented high corrosion potential. Semi-quantitative phase calculation was performed by the Rietveld method using XRD. The presence of FeCr, FeCo, and austenite phases was determined. Based on the performed characterizations, the findings suggested that the FeCrCo deposition, with an epoxy sealing, is suitable to be used as an efficient coating of carbon steel in aggressive corrosive environments. 相似文献
The paper deals with theoretical and experimental aspects of lumped capacitance model (LCM) application for the study of heat transport in different materials. Patented construction of the measuring chamber together with special software the fundamental features of which are presented here allows evaluating thermal conductivity k, specific heat capacity cp and thermal diffusivity α. Obtained results are in relatively very good agreement with those obtained from independent measurement or table values. 相似文献
Polycyclic aromatic hydrocarbons (PAHs) are relatively well-known organic pollutants and due to their carcinogenic and mutagenic properties their presence in the environment still attracts a lot of attention.
According to literature reports and own research, PAHs presence in wastewaters is common. It was confirmed that PAHs are the components of municipal landfill leachate. Membrane techniques are one of the most interesting ways of removing PAHs from leachate.
The purpose of this article is to monitor PAHs concentration changes during the membrane (reverse osmosis - RO) leachate treatment processes. In the first stage of testing leachates were filtrated on the sand bed (pre-filtration). After the pre-filtration they were directed to the membrane module for the main filtration.
Sixteen PAHs listed by EPA were analyzed. The results with information on PAHs concentration in leachate samples were presented using HPLC with fluorescence detection (FLD). The changes in PAHs concentration were determined in leachate samples before and after pre-filtration as well as after RO. The decrease of PAHs concentration in the samples was observed after these processes. The total concentration of 16 PAHs in raw municipal landfill leachates amounted to 23.64–26.95 μg/L. The research confirmed the high efficiency in removal of PAHs while using a reverse osmosis (59–72%). Including the pre-filtration, the overall level of removed PAHs reached 81–86%. The average PAHs concentration after pre-filtration and RO was in the 4.46–4.99 μg/L range. The municipal landfill leachate with a high concentration of PAHs should be cleaned before it is discharged into the environment. 相似文献