A new simple two-axis magnetometer has been developed. based on the superposition of an amorphous ferromagnetic disc over a disc-shaped piezoelectric support. At low frequencies, this device exhibits a sensitivity of ~1.7 μV/μT when the external magnetic field is orthogonal to one of the pick-up coils 相似文献
We studied the development of nutritional iron deficiency 0, 10, 20, 30 and 40 days after the intake of a semisynthetic diet lacking iron (diet 0) and the possible interactions with calcium, phosphorus and magnesium in both control rats and rats after 40 days of iron deficiency. During this period, iron deficiency was found to produce stress in the rats, as evidenced by high levels of cortisol in the serum. High levels of parathyroid hormone (PTH) were also found. There was a considerable increase in the absorption of calcium, phosphorus and magnesium, but the phosphorus and magnesium balance decreased and that of calcium remained practically unchanged, although there was an increase in calcium urinary elimination. Despite the noticeable degree of bone demineralization, which was evident in the femur, serum levels of calcium, phosphorus and magnesium remained constant. The present study shows that severe nutritional ferropenic anaemia provokes significant alterations in the metabolism of calcium, phosphorus and magnesium. We conclude that these alterations should be taken into account in the treatment of this pathology, given its prevalence and the fact that it may exacerbate other pathologies, particularly those related to the metabolism of calcium and phosphorus. 相似文献
Background: Smoking has been causally associated with increased mortality from several diseases, and has increased considerably in many developing countries in the past few decades. Mortality attributable to smoking in the year 2000 was estimated for adult males and females, including estimates by age and for specific diseases in 14 epidemiological subregions of the world.
Methods: Lung cancer mortality was used as an indirect marker of the accumulated hazard of smoking. Never-smoker lung cancer mortality was estimated based on the household use of coal with poor ventilation. Estimates of mortality caused by smoking were made for lung cancer, upper aerodigestive cancer, all other cancers, chronic obstructive pulmonary disease (COPD), other respiratory diseases, cardiovascular diseases, and selected other medical causes. Estimates were limited to ages 30 years and above.
Results: In 2000, an estimated 4.83 million premature deaths in the world were attributable to smoking, 2.41 million in developing countries and 2.43 million in industrialised countries. There were 3.84 million male deaths and 1.00 million female deaths attributable to smoking. 2.69 million smoking attributable deaths were between the ages of 30–69 years, and 2.14 million were 70 years of age and above. The leading causes of death from smoking in industrialised regions were cardiovascular diseases (1.02 million deaths), lung cancer (0.52 million deaths), and COPD (0.31 million deaths), and in the developing world cardiovascular diseases (0.67 million deaths), COPD (0.65 million deaths), and lung cancer (0.33 million deaths). The share of male and female deaths and younger and older adult deaths, and of various diseases in total smoking attributable deaths exhibited large inter-regional heterogeneity, especially in the developing world.
Conclusions: Smoking was an important cause of global mortality in 2000, affecting a large number of diseases. Age, sex, and disease patterns of smoking-caused mortality varied greatly across regions, due to both historical and current smoking patterns, and the presence of other risk factors that affect background mortality from specific diseases.
The European Radiation Dosimetry Group, EURADOS, established a working group consisting of experts whose aim is to assist in the process of harmonisation of individual monitoring as part of the protection of occupationally exposed workers. A catalogue of facilities and internal dosimetric techniques related to individual monitoring in Europe has been completed as a result of this EURADOS study. A questionnaire was sent in 2002 to services requesting information on various topics including type of exposures, techniques used for direct and indirect measurements including calibration and sensitivity data and the methods employed for the assessment of internal doses. Information relating to Quality Control procedures for direct and indirect measurements, Quality Assurance Programmes in the facilities and legal requirements for "approved dosimetric services" were also considered. A total of 71 completed questionnaires were returned by internal dosimetry facilities in 26 countries. This results in an overview of the actual status of the processes used in internal exposure estimation in Europe. In many ways harmonisation is a reality in internal dose assessments, especially when taking into account the measurements of the activity retained or excreted from the body. However, a future study detailing the estimation of minimum detectable activity in the laboratories is highly recommended. Points to focus on in future harmonisation activities are as follows: the process of calculation of doses from measured activity, establishment of guidelines, similar dosimetric tools and application of the same ICRP recommendations. This would lead to a better and more harmonised approach to the estimation of internal exposures in all European facilities. 相似文献
The paper reports the results of an investigation aimed to evaluate the performances of an innovative process for treating tannery wastewater. In such a process biological degradation, carried out in a sequencing batch biofilm reactor (SBBR), is combined with chemical oxidation by ozone. The treatment was carried out at laboratory scale on a real primary effluent coming from a centralized plant treating the wastewater of a large tannery district in Northern Italy. SBBR performances without and with ozonation were compared with very satisfactory results particularly in the latter instance when the recorded COD, TKN, and TSS average removals, (96%), (92%), and (98%), respectively, permitted to achieve the fixed limits enforced by Italian regulation without needing any additional polishing step. With or without ozonation, the process that resulted was characterized by a specific sludge production (0.1 kgVSS/kg CODremoved) significantly lower than the values featuring conventional biological systems (i.e., 0.3-0.5 VSS/kg CODremoved). Moreover, as in the reactor the biomass density results were very high, i.e., 98 gVSS/Lsludge, it was possible to achieve and maintain biomass concentration as high as 20 gVSS/L. 相似文献
The radioisotope techniques used in molecular and cellular biology involve external and internal irradiation risk. The personal dosemeter may be a reasonable indicator for external irradiation. However, it is necessary to control the possible internal contamination associated with the development of these techniques. The aim of this project is to analyse the most usual techniques and to establish programmes of internal monitoring for specific radionuclides (32P, 35S, 14C, 3H, 125I and 131I). To elaborate these programmes it was necessary to analyse the radioisotope techniques. Two models have been applied (NRPB and IAEA) to the more significant techniques, according to the physical and chemical nature of the radionuclides, their potential importance in occupational exposure and the possible injury to the genetic material of the cell. The results allowed the identification of the techniques with possible risk of internal contamination. It was necessary to identify groups of workers that require individual monitoring. The risk groups have been established among the professionals exposed, according to different parameters: the general characteristics of receptor, the radionuclides used (the same user can work with one, two or three radionuclides at the same time) and the results of the models applied. Also a control group was established. The study of possible intakes in these groups has been made by urinalysis and whole-body counter. The theoretical results are coherent with the experimental results. They have allowed guidance to individual monitoring to be proposed. Basically, the document shows: (1) the analysis of the radiosotopic techniques, taking into account the special containment equipment; (2) the establishment of the need of individual monitoring; and (3) the required frequency of measurements in a routine programme. 相似文献
Simultaneous observation of the same solar sources with different instruments is one way to test prelaunch radiometric calibrations and to detect changes in responsivity with time of extreme-ultraviolet instruments in space. Here we present the results of intercalibration of the SUMER (Solar Ultraviolet Measurements of Emitted Radiation) spectrometer (detectors A and B) and the GIS (Grazing Incidence Spectrometer), one of two spectrometers that compose the CDS (Coronal Diagnostic Spectrometer) on the Solar and Heliospheric Observatory (SOHO). The two instruments observed simultaneously radiances of emission lines at or near the center of the solar disk. The emission line chosen for intercomparison was Ne VIII at 770 A. However, such an intercomparison of the SUMER and CDS-GIS measurements means comparing two data sets with large differences in resolution and field of view. The latter difference, especially, introduces differences in the measured intensities caused by the solar variability that is relatively strong in the 770-A line. Using a statistical approach to overcome this problem, we found that the ratio of the GIS to the SUMER average radiances amounted to 2.6 +/- 0.9 before the SOHO's loss of attitude and to 2.1 +/- 0.7 afterward. These findings confirm earlier estimates of the GIS's responsivity being too low, and an update of the GIS calibration is recommended. Despite the large differences in resolution and field of view of the two instruments, the shapes of their normalized and rescaled histograms of the radiances agree well and therefore represent characteristic features of the Ne VIII line. 相似文献