排序方式: 共有30条查询结果,搜索用时 15 毫秒
21.
Cheng B. Chua C. L. Yang Z. Teepe M. Knollenberg C. Strittmatter A. Johnson N. 《Photonics Technology Letters, IEEE》2010,22(5):329-331
22.
Umbach A. Engel T. Bach H.-G. van Waasen S. Droge E. Strittmatter A. Ebert W. Passenberg W. Steingruber R. Schlaak W. Mekonnen G.G. Unterborsch G. Bimberg D. 《Quantum Electronics, IEEE Journal of》1999,35(7):1024-1031
For future long-haul communication systems operating at bitrates of 40 Gbit/s and for broad-band mobile access systems using 38- or 60-GHz carrier frequencies, ultrafast photoreceivers have to be provided. Therefore, an integration concept for InP-based optoelectronic microwave monolithic integrated circuits for the 1.55-μm wavelength regime is demonstrated, which allows independent optimization of the constituting devices. Two different types of photodetectors (PDs), a waveguide-integrated PIN photodiode (PD) and a top-illuminated metal-semiconductor-metal PD, both having bandwidths of up to 70 GHz, have been developed. These are fabricated together with different amplifier designs employing high electron mobility transistors which exhibit transit frequencies of up to 90 GHz. The application to a 40-Gbit/s broadband photoreceiver for high-bit-rate time-division multiplexing systems is reported, as well as the application to 38- and 60-GHz narrow-band photoreceivers for use as optic/millimeterwave converters in mobile communication systems 相似文献
23.
M Eisenhut WD Lehmann W Becker T Behr H Elser W Strittmatter A Steinstr?sser RP Baum T Valerius R Repp Y Deo 《Canadian Metallurgical Quarterly》1996,37(2):362-370
Conjugation chemistry and kit formulated binding of the NHS ester of 6-(4'-(4"-carboxyphenoxy)butyl)-2, 10-dimercapto-2,10-dimethyl-4,8-diazaundecane (NHS-BAT ester) to monoclonal antibodies (MAbs) was investigated. The functionalities of the resulting BAT conjugated and 99mTc-labeled MAbs BW 431/26, MAb 425 and bispecific MDX210 (fragment construct) were tested by immunoreactivity and immunoscintigraphy. METHODS: The kinetics and chemistry of the conjugation reaction were monitored by high-performance liquid chromatography, size-exclusion chromatography and positive fast-atom-bombardment mass spectra (FAB-MS). The 99mTc BAT-MAbs were tested with various immunoreactivity assays. The biodistribution of 99mTc-BAT-BW 431/26 in rats was compared with directly labeled BW 431/26. RESULTS: At pH 8.5 and 25 degrees C, the reactivity of the NHS-BAT ester was high with 90% completion after 30 min. The conjugation yield of 19 microM MAb and 228 microM NHS-BAT ester amounted to 30%. Higher NHS-BAT ester concentrations afforded higher BAT-to-MAb ratios. According to FAB-MS, the conjugation competing hydrolysis surprisingly occurred at the NHS ring. Almost quantitative 99mTc labeling was achieved after 5 min at 25 degrees C. Immunoreactivity of the 99mTc-BAT antibodies showed > 90% recovery and proved to be insensitive to BAT-to-MAb ratios of up to 10. The 99mTc-BAT-BW 431/26 showed similar organ distribution but revealed less urinary excretion compared with the directly labeled BW 431/26. Immunoscintigraphy with 99mTc-labeled and BAT-BW 431/26 and BAT-MAb 425 showed the respective biological function in vivo. CONCLUSION: According to straightforward conjugation chemistry, the ease of 99mTc labeling and the application of a simple ultrafiltration technique, the NHS-BAT ester represents a nondestructive, universally applicable biofunctional ligand to introduce stable 99mTc protein binding sites. Kit formulated conjugation/labeling can be performed with little time requirements and laboratory experience. 相似文献
24.
Joachim Strittmatter Victor Clipa Viorel Gheorghita Paul Gümpel 《Journal of Materials Engineering and Performance》2014,23(7):2696-2703
Actuator elements made of NiTi shape memory material are more and more known in industry because of their unique properties. Due to the martensitic phase change, they can revert to their original shape by heating when subjected to an appropriate treatment. This thermal shape memory effect (SME) can show a significant shape change combined with a considerable force. Therefore such elements can be used to solve many technical tasks in the field of actuating elements and mechatronics and will play an increasing role in the next years, especially within the automotive technology, energy management, power, and mechanical engineering as well as medical technology. Beside this thermal SME, these materials also show a mechanical SME, characterized by a superelastic plateau with reversible elongations in the range of 8%. This behavior is based on the building of stress-induced martensite of loaded austenite material at constant temperature and facilitates a lot of applications especially in the medical field. Both SMEs are attended by energy dissipation during the martensitic phase change. This paper describes the first results obtained on different actuator and superelastic NiTi wires concerning their use as damping elements in automotive safety systems. In a first step, the damping behavior of small NiTi wires up to 0.5 mm diameter was examined at testing speeds varying between 0.1 and 50 mm/s upon an adapted tensile testing machine. In order to realize higher testing speeds, a drop impact testing machine was designed, which allows testing speeds up to 4000 mm/s. After introducing this new type of testing machine, the first results of vertical-shock tests of superelastic and electrically activated actuator wires are presented. The characterization of these high dynamic phase change parameters represents the basis for new applications for shape memory damping elements, especially in automotive safety systems. 相似文献
25.
Strittmatter A. Germann T.D. Pohl J. Pohl U.W. Bimberg D. Rautiainen J. Guina M. Okhotnikov O.G. 《Electronics letters》2008,44(4):290-291
Quantum dots grown by metal organic vapour phase epitaxy in the Stranski-Krastanow regime are succesfully implemented for the first time as active media in optically pumped vertical external cavity surface emitting lasers. To optimise the gain the quantum dots are engineered to match the excited state luminescence to the cavity resonance. Room temperature continuous-wave operation at 1040 nm wavelength is demonstrated. An output power of 280 mW is achieved, limited only by the onset of thermal rollover. The differential conversion efficiency is 6.7%. 相似文献
26.
Ion mobility spectrometry (IMS) has been explored for decades, and its versatility in separation and identification of gas-phase ions is well established. Recently, field asymmetric waveform IMS (FAIMS) has been gaining acceptance in similar applications. Coupled to mass spectrometry (MS), both IMS and FAIMS have shown the potential for broad utility in proteomics and other biological analyses. A major attraction of these separations is extremely high speed, exceeding that of condensed-phase alternatives by orders of magnitude. However, modest separation peak capacities have limited the utility of FAIMS and IMS for analyses of complex mixtures. We report 2-D gas-phase separations that join FAIMS to IMS, in conjunction with high-resolution and accuracy time-of-flight (TOF) MS. Implementation of FAIMS/IMS and IMS/MS interfaces using electrodynamic ion funnels greatly improves sensitivity. Evaluation of FAIMS/IMS/TOF performance for a protein mixture tryptic digest reveals high orthogonality between FAIMS and IMS dimensions and, hence, the benefit of FAIMS filtering prior to IMS/MS. The effective peak capacities in analyses of tryptic peptides are approximately 500 for FAIMS/IMS separations and approximately 10(6) for 3-D FAIMS/IMS/MS, providing a potential platform for ultrahigh-throughput analyses of complex mixtures. 相似文献
27.
Important factors that limit the mass measurement accuracy from a mass spectrometer are related to (1) the type of mass analyzer used and (2) the data processing/calibration methods used to obtain mass values from the raw data. Here, two data processing methods are presented that correct for systematic deviations when the mass of ions is measured using a time-of-flight (TOF) mass spectrometer. The first fitting method is one where m/z values are obtained from fitting peak distributions using double Gaussian functions. A second calibration method takes into account the slight nonlinear response of the TOF analyzer in addition to the drift in the calibration over time. Using multivariate regression, both of these two effects can be corrected for using a single calibration formula. Achievable performance was evaluated with a trypsin digestion of serum albumin and proteins from the organism D. radiodurans that was analyzed using gradient reversed-phase liquid chromatography combined with an electrospray ionization orthogonal TOF mass spectrometer. The root-mean-square deviation between the theoretical and experimental m/z values for serum albumin tryptic peptides was found to be 8 ppm using the double Gaussian-multivariate method compared to 29 ppm determined using linear calibration and normal peak centroiding. An advantage of the methods presented here is that no calibrant compounds need to be added to the mobile phase, thereby avoiding interference effects and signal suppression of analytes. 相似文献
28.
We have used cultures of purified embryonic rat spinal cord motor neurons to study the neurotoxic effects of prolonged ionotropic glutamate receptor activation. NMDA and non-NMDA glutamate receptor agonists kill a maximum of 40% of the motor neurons in a concentration- and time-dependent manner, which can be blocked by receptor subtype-specific antagonists. Subunit-specific antibodies stain all of the motor neurons with approximately the same intensity and for the same repertoire of subunits, suggesting that the survival of the nonvulnerable population is unlikely to be due to the lack of glutamate receptor expression. Extracellular Ca2+ is required for excitotoxicity, and the route of entry initiated by activation of non-NMDA, but not NMDA, receptors is L-type Ca2+ channels. Ca2+ imaging of motor neurons after application of specific glutamate receptor agonists reveals a sustained rise in intracellular Ca2+ that is present to a similar degree in most motor neurons, and can be blocked by appropriate receptor/channel antagonists. Although the lethal effects of glutamate receptor agonists are seen in only a subset of cultured motor neurons, the basis of this selectivity is unlikely to be simply the glutamate receptor phenotype or the level/pattern of rise in agonist-evoked intracellular Ca2+. 相似文献
29.
Shen Y Strittmatter EF Zhang R Metz TO Moore RJ Li F Udseth HR Smith RD Unger KK Kumar D Lubda D 《Analytical chemistry》2005,77(23):7763-7773
The throughput of proteomics measurements that provide broad protein coverage is limited by the quality and speed of both the separations as well as the subsequent mass spectrometric analysis; at present, analysis times can range anywhere from hours (high throughput) to days or longer (low throughput). We have explored the basis for proteomics analyses conducted on the order of minutes using high-speed capillary RPLC combined through on-line electrospray ionization interface with high-accuracy mass spectrometry (MS) measurements. Short 0.8-microm porous C18 particle-packed 50-microm-i.d. capillaries were used to speed the RPLC separations while still providing high-quality separations. Both time-of-flight (TOF) and Fourier transform ion cyclotron resonance (FTICR) MS were applied for identifying peptides using the accurate mass and time (AMT) tag approach. Peptide RPLC relative retention (elution) times that were generated by solvent gradients that differed by at least 25-fold were found to provide relative elution times that agreed to within 5%, which provides the basis for using peptide AMT tags for higher throughput proteomics measurements. For fast MS acquisition speeds (e.g., 0.2 s for TOF and either approximately 0.3 or approximately 0.6 s for FTICR), peptide mass measurement accuracies of better than +/-15 ppm were obtained with the high-speed RPLC separations. The ability to identify peptides and the overall proteome coverage was determined by factors that include the separation peak capacity, the sensitivity of the MS (with fast scanning), and the accuracy of both the mass measurements and the relative RPLC peptide elution times. The experimental RPLC relative elution time accuracies of 5% (using high-speed capillary RPLC) and mass measurement accuracies of better than +/-15 ppm allowed for the confident identification of >2800 peptides and >760 proteins from >13,000 different putative peptides detected from a Shewanellaoneidensis tryptic digest. Initial results for both RPLC-ESI-TOF and RPLC-ESI-FTICR MS were similar, with approximately 2000 different peptides from approximately 600 different proteins identified within 2-3 min. For <120-s proteomic analysis, TOF MS analyses were more effective, while FTICR MS was more effective for the >150-s analysis due to the improved mass accuracies attained using longer spectrum acquisition times. 相似文献
30.
Use of artificial neural networks for the accurate prediction of peptide liquid chromatography elution times in proteome analyses 总被引:3,自引:0,他引:3
Petritis K Kangas LJ Ferguson PL Anderson GA Pasa-Tolić L Lipton MS Auberry KJ Strittmatter EF Shen Y Zhao R Smith RD 《Analytical chemistry》2003,75(5):1039-1048
The use of artificial neural networks (ANNs) is described for predicting the reversed-phase liquid chromatography retention times of peptides enzymatically digested from proteome-wide proteins. To enable the accurate comparison of the numerous LC/MS data sets, a genetic algorithm was developed to normalize the peptide retention data into a range (from 0 to 1), improving the peptide elution time reproducibility to approximately 1%. The network developed in this study was based on amino acid residue composition and consists of 20 input nodes, 2 hidden nodes, and 1 output node. A data set of approximately 7000 confidently identified peptides from the microorganism Deinococcus radiodurans was used for the training of the ANN. The ANN was then used to predict the elution times for another set of 5200 peptides tentatively identified by MS/MS from a different microorganism (Shewanella oneidensis). The model was found to predict the elution times of peptides with up to 54 amino acid residues (the longest peptide identified after tryptic digestion of S. oneidensis) with an average accuracy of approximately 3%. This predictive capability was then used to distinguish with high confidence isobar peptides otherwise indistinguishable by accurate mass measurements as well as to uncover peptide misidentifications. Thus, integration of ANN peptide elution time prediction in the proteomic research will increase both the number of protein identifications and their confidence. 相似文献