排序方式: 共有24条查询结果,搜索用时 15 毫秒
21.
Two sets of super-synchronization speed control assemblies for two 80 MVA motor-generator units have been developed successfully in order to satisfy the demand of the toroidal field system in the HL-2A tokamak. Based on the three-phase logical no-circumfluence a.c./a.c. cycloconverter, the speeds of two 2500 kW double fed drive motors have been regulated by means of the vector control technology. The maximum operating speed of each motor- generator unit has been raised from 1488 rpm (revolutions per minute) to 1650 rpm and the released energy of each unit during a pulsed discharge can reach 500 MJ. As a result, the toroidal field system has the capacity to provide 2.8 tesla (T) in HL-2A experiments. 相似文献
22.
介绍了中国环流器2号A(HL-2A)装置中环向磁场线圈脉冲供电系统,基于MATLAB/Simulink和一些等效方法建立起包括80MVA六相交流飞轮发电机及其励磁系统与其它部件的环向磁场线圈脉冲供电系统仿真模型,仿真结果与实验结果基本相互吻合. 相似文献
23.
介绍了300 MVA脉冲发电机组的滑差装置。对机组采取滑差方式的起动过程进行了分析和等效建模。根据机组实际起动过程电气波形,利用非线性规划模型,建立了滑差装置液体电阻等效仿真模型,并代入机组参数对起动过程进行仿真,仿真结果和实际波形吻合,验证了模型的正确性。在此基础上,为了使机组的转速达到额定转速,提出在滑差装置液体电阻低位时并入两级固体金属电阻后短接的方案,给出了两级固体金属电阻的阻值等理论参数,并通过仿真验证了方案的可行性。建立的仿真模型可以作为研究不同参数、不同控制策略下的机组起动过程动态特性的重要工具。 相似文献
24.