全文获取类型
收费全文 | 214篇 |
免费 | 18篇 |
国内免费 | 5篇 |
专业分类
综合类 | 2篇 |
化学工业 | 70篇 |
金属工艺 | 7篇 |
机械仪表 | 3篇 |
建筑科学 | 4篇 |
矿业工程 | 1篇 |
能源动力 | 9篇 |
轻工业 | 29篇 |
水利工程 | 3篇 |
石油天然气 | 2篇 |
无线电 | 25篇 |
一般工业技术 | 41篇 |
冶金工业 | 5篇 |
自动化技术 | 36篇 |
出版年
2024年 | 1篇 |
2023年 | 8篇 |
2022年 | 11篇 |
2021年 | 18篇 |
2020年 | 25篇 |
2019年 | 26篇 |
2018年 | 25篇 |
2017年 | 16篇 |
2016年 | 17篇 |
2015年 | 9篇 |
2014年 | 15篇 |
2013年 | 24篇 |
2012年 | 10篇 |
2011年 | 13篇 |
2010年 | 7篇 |
2009年 | 5篇 |
2008年 | 4篇 |
2006年 | 2篇 |
2004年 | 1篇 |
排序方式: 共有237条查询结果,搜索用时 93 毫秒
11.
Polyvinylpolypyrrolidone-supported chlorosulfonic acid has been successfully applied to perform one-pot reaction of arylaldehydes, urea, ethylacetoacetate, or cyclic 1,3-diketo compounds under solvent-free condition at 70°C to provide a series of dihydropyrimidinones and octahydroquinazolin-2,5-diones in good to excellent yields. The method offers several advantages such as high yield, short reaction time, simple workup, easy preparation, and reusability of the catalyst. The [PVPP-SO3H]+Cl? catalyst was characterized via Fourier transform infrared spectroscopy (FT-IR) and thermal gravimetric analysis (TGA). Moreover, the catalyst could be recycled several times without significant loss of its catalytic activity. Clean methodologies, easy work-up procedure, high yield, and simple preparation of the catalyst are some advantages of this article. 相似文献
12.
Majid Azarang Mehran Sookhakian Mousa Aliahmad Masoumeh Dorraj Wan Jeffrey Basirun Boon Tong Goh Yatimah Alias 《International Journal of Hydrogen Energy》2018,43(32):14905-14914
Nitrogen-doped graphene-ZnS composite (NG-ZnS) was synthesized by thermal treatment of graphene-ZnS composite (G-ZnS) in NH3 medium. In the second step, the as-synthesized samples were deposited on indium tin oxide glass (ITO) by electrophoretic deposition for photocatalytic hydrogen evolution reaction. The as-prepared NG-ZnS-modified ITO electrode displayed excellent photocatalytic activity, rapid transient photocurrent response, superior stability and high recyclability compared to the pure ZnS and G-ZnS-modified ITO electrode due to the synergy between the photocatalytic activity of ZnS nanorods and the large surface area and high conductivity of N-graphene. 相似文献
13.
14.
Mahdieh Namvar-Mahboub Ahsani Fatemeh Ansari Soudabeh 《Theoretical Foundations of Chemical Engineering》2020,54(5):940-948
Theoretical Foundations of Chemical Engineering - Effect of activating procedure on the physic-chemical properties and adsorption performance of activated carbon was investigated. For this,... 相似文献
15.
Experimental Study and Mathematical Modeling of NO Removal Using the UV/H2O2 Advanced Oxidation Process
下载免费PDF全文
![点击此处可从《化学工程与技术》网站下载免费的PDF全文](/ch/ext_images/free.gif)
An experimental study on NO removal via UV/H2O2 process was conducted in a semi‐continuous bubble‐column reactor and the effect of some operation parameters including NO initial concentration and gas flow rates on removal efficiency was investigated. Applying UV light increased the efficiency significantly. The steady‐state removal efficiency was found to be higher at the lower gas flow rates. The bubble size as an important factor in mass transfer calculations and modeling procedure was determined at different gas flow rates using bubble photographs and image processing technique. In the ranges of flow rates studied here, the gas flow rate had no significant effect on the bubble diameter. A mathematical model was developed to describe the NO removal process. The model predictions were compared with existing experimental data, confirming a good agreement of the data. 相似文献
16.
A novel modified glassy carbon electrode with a film of nanodiamond-graphite/chitosan is constructed and used for the sensitive voltammetric determination of azathioprine (Aza). The surface morphology and thickness of the film modifier are characterized using atomic force microscopy. The electrochemical response characteristics of the electrode toward Aza are investigated by means of cyclic voltammetry. The modified electrode showed an efficient catalytic role for the electrochemical reduction of Aza, leading to a remarkable decrease in reduction overpotential and enhancement of the kinetics of the electrode reaction with a significant increase of peak current. The effects of experimental variables, such as the deposited amount of modifier suspension, the pH of the supporting electrolyte, the accumulation potential and time were investigated. Under optimal conditions, the modified electrode showed a wide linear response to the concentration of Aza in the range of 0.2-100 μM with a detection limit of 65 nM. The prepared modified electrode showed several advantages: simple preparation method, high stability and uniformity in the composite film, high sensitivity, excellent catalytic activity in physiological conditions and good reproducibility. The modified electrode can be successfully applied to the accurate determination of trace amounts of Aza in pharmaceutical and clinical preparations. 相似文献
17.
The oxidation of alcohols with tert-butylhydroperoxide (TBHP), in the presence of Mn2+ complexes immobilized in the pore channels of mesoporous hexagonal molecular sieves (HMS), were investigated. It was found that immobilized [Mn(bpy)2]2+/HMS is an efficient catalyst for the oxidation of alcohols such as benzyl alcohol, n-hexanol and cyclohexanol. The effects of reaction time, amount of Mn2+ in the catalyst, type of substrates and oxidants in this catalysis system were investigated. At optimum conditions, TBHP is more efficient oxidant with respect to H2O2. Following order has been observed for the percentage of conversions of alcohols: benzylic >1° >2°. 相似文献
18.
The electrospinning of the biopolymer chitosan (CS) and poly(vinyl alcohol) (PVA) was investigated with 90% acetic acid as the solvent and with different CS/PVA ratios. The long chains of high‐molecular‐weight CS prevented it from forming nanofibers in a high‐voltage field. The treatment of CS under high‐temperature alkali conditions reduced its molecular weight exponentially with the treatment time and caused a reduction of the viscosity consequently. PVA, acting as a plasticizer and accompanied by the alkali‐treated CS of lower viscosity, made the electrospinning of CS/PVA blends possible. The effects of the duration of the alkali treatment on the molecular weight of CS and its viscosity were investigated and optimized. The diameter of the bicomponent nanofiber decreased proportionally with the increase in the CS portion, whereas the surface porosity increased inversely. Fourier transform infrared studies illustrated that the alkali treatment or blending of CS with PVA had no effect on its chemical nature. © 2009 Wiley Periodicals, Inc. J Appl Polym Sci, 2009 相似文献
19.
Mahdieh Jahangiri Farhad Razaghian 《Analog Integrated Circuits and Signal Processing》2014,80(3):551-556
With the development of analog integrated circuits technology and due to the complexity, and various types of faults that occur in analog integrated circuits, fault detection is a new idea, has been studied in recent decades. In this paper a three amplifier state variable filter is used as circuit under test (CUT) and, a hybrid neural network is proposed for soft fault diagnosis of the CUT. Genetic algorithm (GA) has the powerful ability of searching the global optimal solution, and back propagation (BP) algorithm has the feature of rapid convergence on the local optima. The hybrid of two algorithm will improve the evolving speed of neural network. GA-BP scheme adopts GA to search the optimal combination of weights in the solution space, and then uses BP algorithm to obtain the accurate optimal solution quickly. Experiment results show that the proposed GA-BP scheme is more efficient and effective than BP algorithm. 相似文献
20.
Measurements were made according to IEEE standard 644-1994 at a height of 1 m above floor level. It is concluded that none of the measurements exceeded the ACGIH threshold limit value. Among all control rooms the highest measured density amount is 0.69 μT in the control room of Ozgol substation and the lowest is 0.2 μT in the post of Shahid Firouzi. The control room of Ozgol substation is located in the second floor and bus-bars are located at a short distance from the window on the east, and so the highest recorded magnetic field is measured in this control room. Among all switchgear parts the highest amount 9.15 μT is measured in Kan substation. None of the measurements exceeded the ACGIH threshold limit value. 相似文献