首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   70篇
  免费   6篇
化学工业   23篇
建筑科学   4篇
能源动力   2篇
轻工业   21篇
水利工程   2篇
无线电   2篇
一般工业技术   14篇
自动化技术   8篇
  2024年   1篇
  2023年   3篇
  2022年   3篇
  2021年   4篇
  2020年   7篇
  2019年   3篇
  2018年   10篇
  2017年   2篇
  2016年   3篇
  2015年   2篇
  2014年   1篇
  2013年   4篇
  2012年   3篇
  2011年   4篇
  2010年   1篇
  2009年   6篇
  2008年   7篇
  2007年   6篇
  2006年   1篇
  2005年   1篇
  2004年   3篇
  2002年   1篇
排序方式: 共有76条查询结果,搜索用时 0 毫秒
31.
Novel fumed silica filled thermoplastic poly(dimethylsiloxane-urea) (TPSU) segmented copolymers were synthesized and characterized. TPSU copolymers were prepared from a cycloaliphatic diisocyanate, aminopropyl terminated PDMS oligomers with number average molecular weights of 3,200, 10,800 and 31,500 g/mol and 2-methyl-1,5-diaminopentane chain extender. Two different types of fumed silica HDK H2000 (hydrophobic) and HDK N20 (hydrophilic) were utilized and incorporated into silicone-urea copolymers in amounts of 1-60% by weight. Influence of the silica type (hydrophilic versus hydrophobic), amount of silica loading and the PDMS soft segment molecular weight on the morphology, tensile properties and modulus-temperature behavior of the nanocomposites were determined. Major observations of this study were: (i) under the blending conditions used, incorporation of silica does not seem to interfere significantly with the hydrogen bonding between urea groups, (ii) incorporation of silica does not affect the glass transition temperature of PDMS, (iii) incorporation of silica influences the tensile and thermomechanical properties of silicone-urea segmented copolymers significantly, (iv) average molecular weight of the PDMS soft segment in the silicone-urea copolymer plays a critical role on the improvement of the tensile properties of the fumed silica/TPSU composites.  相似文献   
32.
Journal of Applied Electrochemistry - Apart from the generally dominant trivalent oxidation state, several lanthanides can occur in divalent or tetravalent states as well. Changing the valence...  相似文献   
33.
34.
In this study production of fine particle Fe2O3 via microwave processing of Fe(NO3)3.nH2O followed by low temperature annealing was reported. XRD was used to characterize the structural properties of nanoparticles. Approximate particle sizes were between 3-13 nm according to Scherrer's equation. Single point BET measurement results also show that samples have large surface area and they are nanometer sized particles. TEM study was conducted to examine the structure of the nanoparticles. TEM figure is in good agreement with the results obtained from Scherrer's equation using XRD spectra. In order to characterize the magnetic properties of the nanoparticles VSM (Vibrating Sample Magnetometer) was used. From these results it can be concluded that the sample containing only maghemite phase exhibits superparamagnetic behaviour, on the other hand sample containing both hematite and maghemite phases shows paramagnetic behaviour above 300 K, superparamagnetic behavior at lower temperatures.  相似文献   
35.
Clinoptilolite, a natural zeolite, was investigated as an inexpensive and effective adsorbent for the adsorption of Toluidine Blue O (TBO) from its aqueous solution. The effect of parameters such as the initial concentration of TBO, the solution of pH, contact time, temperature and particle size on the TBO adsorption was examined. The adsorption rate data were analysed according to the first and second-order kinetic models. Kinetic studies show that adsorption of TBO on clinoptilolite was fitted to the second-order adsorption model with two-step diffusion process. The activation energies for TBO adsorption on clinoptilolite for the first and second diffusion processes were 8.72 kJ mol(-1) and 19.02 kJ mol(-1), respectively. The adsorption isotherm was well fitted to both the Langmuir and Freundlich models. The maximum adsorption capacity of clinoptilolite for TBO was 2.1x10(-4) mol g(-1) at solution pH of 11.0.  相似文献   
36.
Undoped ZnO and Al-doped zinc oxide (ZnO:Al) thin films with different Al concentrations were prepared onto Si (100) substrate by pulsed filtered cathodic vacuum arc deposition system at room temperature. The influence of doping on the structural and optical properties of thin films was investigated. The preferential (002) orientation was weakened by high aluminum doping in films. Raman measurement was performed for the doping effects in the ZnO. Atomic force microscopy images revealed that the surface of undoped ZnO film grown at RT was smoother than that of the Al-doped ZnO (ZnO:Al) films. The reflectance of all films was studied as a function of wavelength using UV–Vis–NIR spectrophotometer. Average total reflectance values of about 35 % in the wavelength range of 400–800 nm were obtained. Optical band gap of the films was determined using the reflectance spectra by means of Kubelka–Munk formula. From optical properties, the band gap energy was estimated for all films.  相似文献   
37.

Purpose

To compare the 24 month visual, refractive, topographic and aberrometric results of the accelerated and standard corneal collagen cross-linking (CXL) in pediatric keratoconus patients.

Methods

87 eyes of 64 consecutive keratoconus patients under 18 years old with 24 month follow-up period following standard or accelerated CXL were included. 38 eyes received standard CXL (3 Mw/cm2, 30?min), while 49 eyes had accelerated CXL (9?mW/cm2, 10?min). Changes in the uncorrected (UCVA) and best corrected visual acuity (BCVA), spherical equivalent (SE), manifest astigmatism (MA), corneal topographic parameters, and corneal aberrations such as spherical aberration (SA), high order aberrations (HOAs), horizontal and vertical coma were evaluated. Corneal haze was graded and progression rate was assessed.

Results

The difference between baseline and 24 months postoperative UCVA, BCVA, SimK (keratometry)-1, SimK-2, Kmax, and the corneal aberrations were not significantly different between the two groups (p?>?0.05 for all). The mean reduction in thinnest corneal pachymetry from baseline to 24 months after CXL was higher in accelerated CXL group (p?=?0.007). The progression rate was 13.1% in standard and 16.3% in accelerated group (p?=?0.754). There were no differences in the grade of corneal haze between the two groups (p?=?0.249). No complications were observed in the both groups.

Conclusion

The 24 month results of accelerated and standard CXL revealed that, the efficacy and safety of accelerated CXL were the same with standard CXL in pediatric keratoconus patients. As being a rapid procedure, accelerated CXL appears to be more benefical for pediatric patients.  相似文献   
38.
ABSTRACT:  Dielectric properties can be used to understand the behavior of food materials during microwave processing. Dielectric properties influence the level of interaction between food and high frequency electromagnetic energy. Dielectric properties are, therefore, important in the design of foods intended for microwave preparation. In this study, it was aimed to determine the variation of dielectric properties of different cake formulations during baking in microwave and infrared–microwave combination oven. In addition, the effects of formulation and temperature on dielectric properties of cake batter were examined. Dielectric constant and loss factor of cake samples were shown to be dependent on formulation, baking time, and temperature. The increase in baking time and temperature decreased dielectric constant and loss factor of all formulations. Fat content was shown to increase dielectric constant and loss factor of cakes.  相似文献   
39.
The objective of this study was to determine the possibility of using Mixolab® to predict the cake baking quality of different wheat flours. Mixolab® data were also compared with various flour quality characteristics. The correlations between Alveoconsistograph data and the cake quality characteristics were not significant. Therefore, Alveoconsistograph test does not seem to be useful to predict the cake quality of the flour samples. Mixolab® characteristics C2, C3, C4 and C5 were found to be significantly correlated with volume index while C5 was correlated with hardness of cakes. The parameters C2 to C5 represent the end point of the corresponding mixing stages. The flour samples which gave higher cake hardness values had higher C5 values and the samples with lower cake volumes had higher C2, C3, C4 and C5 values. It seems to be possible to estimate the texture and volume of cakes by these values. Therefore, Mixolab® seems to be a useful tool to predict the cake making quality of flour samples.  相似文献   
40.
Precise timing and dosing of potent small‐molecule drugs carries significant potential for effective pharmaceutical management of disorders that exhibit time‐varying therapeutic windows such as epilepsy. This study demonstrates the use of alumina‐coated nanoporous gold (np‐Au) thin film electrodes for iontophoretic release of fluorescein as a small‐molecule drug surrogate with picogram dosing and a few seconds temporal resolution. A custom microfluidic platform is engineered to trigger molecular release from an integrated np‐Au chip and monitor the resulting time‐varying fluorescein concentration. Following a systematic study of the influence of applied voltage on loading capacity and release kinetics, a LabVIEW‐based closed‐loop control interface is employed to demonstrate voltage‐gated fluorescein release with preprogrammed arbitrary concentrations waveforms.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号