全文获取类型
收费全文 | 137篇 |
免费 | 8篇 |
国内免费 | 1篇 |
专业分类
电工技术 | 3篇 |
化学工业 | 54篇 |
金属工艺 | 3篇 |
机械仪表 | 4篇 |
建筑科学 | 3篇 |
能源动力 | 5篇 |
轻工业 | 15篇 |
无线电 | 6篇 |
一般工业技术 | 31篇 |
冶金工业 | 2篇 |
自动化技术 | 20篇 |
出版年
2023年 | 1篇 |
2022年 | 4篇 |
2021年 | 3篇 |
2020年 | 9篇 |
2019年 | 7篇 |
2018年 | 9篇 |
2017年 | 6篇 |
2016年 | 4篇 |
2015年 | 5篇 |
2014年 | 7篇 |
2013年 | 20篇 |
2012年 | 12篇 |
2011年 | 12篇 |
2010年 | 11篇 |
2009年 | 6篇 |
2007年 | 5篇 |
2006年 | 7篇 |
2005年 | 4篇 |
2004年 | 1篇 |
2003年 | 1篇 |
2002年 | 2篇 |
2000年 | 2篇 |
1999年 | 1篇 |
1998年 | 2篇 |
1997年 | 1篇 |
1996年 | 3篇 |
1989年 | 1篇 |
排序方式: 共有146条查询结果,搜索用时 15 毫秒
11.
Non‐intrusive characterization of particle size changes in fluidized beds using recurrence plots
下载免费PDF全文
![点击此处可从《American Institute of Chemical Engineers》网站下载免费的PDF全文](/ch/ext_images/free.gif)
Chiya Savari Rahmat Sotudeh‐Gharebagh Reza Zarghami Navid Mostoufi 《American Institute of Chemical Engineers》2016,62(10):3547-3561
An on‐line method is developed for monitoring of mean particle size in fluidized beds using pressure fluctuations (PFs) and acoustic emissions (AE) signal by recurrence plot (RP) and recurrence quantification analysis (RQA). PFs and AE signals of a lab‐scale fluidized bed were measured simultaneously at various superficial gas velocities and mean particle sizes. Although the AE signals are often very complicated due to many different acoustic sources in the bed, applying RP analyses showed that small changes in mean particle size can be detected by visual comparison of AE‐RP structures, while this cannot be distinguished by graphical RP analysis of PFs. Moreover, the hydrodynamics of the bed was inspected through RQA analysis of both signals. For this purpose, recurrence rate, determinism, laminarity, average length of diagonal and vertical lines were extracted from RPs showing the effect of an increase in the mean particle size. © 2016 American Institute of Chemical Engineers AIChE J, 62: 3547–3561, 2016 相似文献
12.
The application of hollow and filament-filled single asymmetric membrane fibers, consisting of a thin silicone layer on a tubular microporous support, for removing CO(2) in suppressed ion chromatography effluents is described. With appropriate choice of the removal device and operating conditions, the CO(2) can be essentially quantitatively (99+%) removed. For carbonate-based eluents, the use of such devices greatly reduces or eliminates the water dip, permitting better quantitation of poorly retained anions that elute close to the dip, allows practical gradient chromatography, and improves noise levels and attainable detection limits. In hydroxide eluent chromatography, the device largely removes the response from CO(2) present in the samples; this greatly aids atmospheric trace gas analysis by IC. Device dimensions are such that the dispersion introduced by the device is small. 相似文献
13.
Shafaat Ahmed Salahudeen Othman AlOthman Rabeh H. Elleithy S. M. Al‐Zahrani Abdul Razak Bin Rahmat 《应用聚合物科学杂志》2013,127(4):2739-2748
Optimization of rotor speed based on stretching, efficiency, and viscous heating in nonintermeshing internal batch mixer has been investigated using polymer melt. A practical optimization technique was followed for optimization. Four different rotor speeds were used and characterized numerically with viscous dissipation and stretching. The heat distribution between rotor edge and mixer wall was calculated. Stretching experienced by the fluid was analyzed and the result was verified experimentally using particle tracking method. Exponential increase of energy dissipation between the rotor edge and the barrel at higher speed highlighted the importance of choosing the thermal properties of the polymer to avoid thermal degradation. © 2012 Wiley Periodicals, Inc. J. Appl. Polym. Sci., 2013 相似文献
14.
M.S. Liza R. Abdul Rahman B. Mandana S. Jinap A. Rahmat I.S.M. Zaidul A. Hamid 《Food and Bioproducts Processing》2010,88(2-3):319-326
The bioactive flavonoid compounds of Strobilanthes crispus (Pecah Kaca) leaves obtained by using supercritical carbon dioxide (SC-CO2) extraction were investigated and the obtained crude extract yields were compared in order to select the best operation parameters. Since carbon dioxide is a non-polar solvent, ethanol was used as co-solvent to increase the polarity of the fluid. The studied parameters were pressure (100, 150 and 200 bar), temperature (40, 50 and 60 °C) and dynamic extraction time (40, 60 and 80 min). The optimum extraction condition occurred at 200 bar, 50 °C and 60 min. Based on the mean value, pressure had dominant effect on the extraction yield. Apart from the optimum SFE conditions two other conditions namely at minimum (100 bar, 40 °C, 40 min) and maximum (200 bar, 60 °C, 80 min) levels of each studied parameters as control runs were analyzed by HPLC to determine the major bioactive flavonoid compounds from S. crispus. Under the optimum conditions eight flavonoid compounds were identified; they were (+)-catechin, (?)-epicatechin, rutin, myricetin, luteolin, apigenin, naringenin and kaempferol. 相似文献
15.
Shabnam Sanaei Navid Mostoufi Ramin Radmanesh Rahmat Sotudeh‐Gharebagh Christophe Guy Jamal Chaouki 《加拿大化工杂志》2010,88(1):1-11
Effect of temperature on the hydrodynamics of bubbling gas–solid fluidized beds was investigated in this work. Experiments were carried out at different temperatures ranged of 25–600°C and different superficial gas velocities in the range of 0.17–0.78 m/s with sand particles. The time‐position trajectory of particles was obtained by the radioactive particle tracking technique at elevated temperature. These data were used for determination of some hydrodynamic parameters (mean velocity of upward and downward‐moving particles, jump frequency, cycle frequency, and axial/radial diffusivities) which are representative to solids mixing through the bed. It was shown that solids mixing and diffusivity of particles increases by increasing temperature up to around 300°C. However, these parameters decrease by further increasing the temperature to higher than 300°C. This could be attributed to the properties of bubble and emulsion phases. Results of this study indicated that the bubbles grow up to a maximum diameter by increasing the temperature up to 300°C, after which the bubbles become smaller. The results showed that due to the wall effect, there is no significant change in the mean velocity of downward‐moving clusters. In order to explain these trends, surface tension of emulsion between the rising bubble and the emulsion phase was introduced and evaluated in the bubbling fluidized bed. The results showed that surface tension between bubble and emulsion is increased by increasing temperature up to 300°C, however, after that it acts in oppositely. 相似文献
16.
17.
This paper investigates possible improvements in grid voltage stability and transient stability with wind energy converter units using modified P/Q control. The voltage source converter (VSC) in modern variable speed wind turbines is utilized to achieve this enhancement. The findings show that using only available hardware for variable-speed turbines improvements could be obtained in all cases. Moreover, it was found that power system stability improvement is often larger when the control is modified for a given variable speed wind turbine rather than when standard variable speed turbines are used instead of fixed speed turbines. To demonstrate that the suggested modifications can be incorporated in real installations, a real situation is presented where short-term voltage stability is improved as an additional feature of an existing VSC high voltage direct current (HVDC) installation 相似文献
18.
Rahmat Budiarto Masashi Yamada Hidenori Itoh Hirohisa Seki 《Computers & Industrial Engineering》1996,31(3-4):939-943
In many method of the cat's cradle string diagram processing in use today, there is no a strong emphasis on user interaction. This paper discusses a method for constructing cat's cradle string diagram in 2-D. The method uses a string representation and processing in 2-D which preserves the topology characteristics of the string diagram and also uses a small data volume. The inputted string diagram is transformed onto its cat's cradle string diagram by geometric transformation and GA. The method allows the user to interactively construct a cat's cradle string diagram. Three operations are used for constructing cat's cradle diagram, they are pull (over and under), release and exchange. An implemented program executed some shapes of cat's cradle for verifying the method. 相似文献
19.
Rahmat Sadeghi 《Chemical engineering science》2006,61(23):7786-7794
A new model for representation of the excess Gibbs energy of polymer-electrolyte solutions is proposed. The excess Gibbs energy of a polymer-electrolyte solution is expressed as a sum of contributions of a combinatorial, a long-range and a short-range excess Gibbs energy term. The Flory-Huggins expression and the Pitzer's extension of Debye-Hückel function are used, respectively, as a combinatorial and a long-range contribution to the excess Gibbs energy. A new expression based on the local composition concept, which is the modified nonrandom two-liquid (NRTL) model, is developed to account for the short-range contribution to the excess Gibbs energy. The model provides a versatile and flexible thermodynamic framework for both correlating and predicting the phase equilibrium of electrolyte solutions, polymer solutions and complex systems containing both electrolytes and polymers. The utility of the model is demonstrated with successful representation of vapor-liquid equilibrium of several PEG or PPG-salt-H2O systems at different polymer molar masses. Results are compared with those obtained from the NRTL model. 相似文献
20.
Approximately one-third of the area (14-mm diameter of a 25-mm diameter) of a 5-microm uniform pore size polycarbonate filter is continuously wetted by a 0.25 mL/min water mist. The water forms a continuous thin film on the filter and percolates through it. The flowing water substantially reduces the effective pore size of the filter. At the operational air sampling flow rate of 1.5 standard liters per minute, such a particle collector (PC) efficiently captures particles down to very small size. As determined by fluorescein-tagged NaCl aerosol generated by a vibrating orifice aerosol generator, the capture efficiency was 97.7+% for particle aerodynamic diameters ranging from 0.28 to 3.88 microm. Further, 55.3 and 80.3% of 25- and 100-nm (NH4)2SO4 particles generated by size classification with a differential mobility analyzer were respectively collected by the device. The PC is integrally coupled with a liquid collection reservoir. The liquid effluent from the wetted filter collector, bearing the soluble components of the aerosol, can be continuously collected or periodically withdrawn. The latter strategy permits the use of a robust syringe pump for the purpose. Coupled with a PM2.5 cyclone inlet and a membrane-based parallel plate denuder at the front end and an ion chromatograph at the back end, the PC readily operated for at least 4-week periods without filter replacement or any other maintenance. 相似文献